{"id":6289,"date":"2026-09-21T09:54:31","date_gmt":"2026-09-21T09:54:31","guid":{"rendered":"https:\/\/europascal.de\/?post_type=product&#038;p=6289"},"modified":"2026-09-21T10:45:22","modified_gmt":"2026-09-21T10:45:22","slug":"additel-adt-878-reference-dry-well-calibrator","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-adt-878-reference-dry-well-calibrator\/","title":{"rendered":"Additel ADT 878 Precision Reference Dry-Block Calibrator"},"content":{"rendered":"<p class=\"isSelectedEnd\">The <strong>Additel ADT 878 Reference Dry Well Calibrator<\/strong> is a high precision temperature calibration solution designed for demanding applications in calibration laboratories, quality assurance, research and industrial metrology. The series combines excellent temperature stability and uniformity with automated calibration functions, a large color touchscreen and optional integrated process measurement capabilities. The product family includes the <strong>ADT 878-160, ADT 878-425, ADT 878-700 and ADT 878-1210<\/strong>, covering an overall temperature range from <strong>\u221240 \u00b0C to 1,210 \u00b0C<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">Unlike the standard ADT 875 series, the <strong>Additel ADT 878<\/strong> is designed as a reference dry well calibrator. Additel places particular emphasis on accuracy, stability and both axial and radial temperature uniformity. This makes the ADT 878 series particularly suitable for applications where the requirements for the temperature reference go beyond a basic functional test of temperature sensors.<\/p>\n<p class=\"isSelectedEnd\">The <strong>ADT 878-160<\/strong> covers temperatures from <strong>\u221240 \u00b0C to 160 \u00b0C<\/strong> and achieves a display accuracy of <strong>\u00b10.1 \u00b0C<\/strong> over the entire range. Its 30 minute stability is only <strong>\u00b10.005 \u00b0C<\/strong>. This makes it an excellent choice for precise calibration of Pt100 probes, resistance thermometers, digital thermometers and temperature transmitters.<\/p>\n<p class=\"isSelectedEnd\">The <strong>ADT 878-425<\/strong> extends the temperature range from <strong>33 \u00b0C to 425 \u00b0C<\/strong>. Additel specifies a display accuracy of <strong>\u00b10.2 \u00b0C across the entire range<\/strong>. Stability is \u00b10.010 \u00b0C at 100 \u00b0C, \u00b10.015 \u00b0C at 225 \u00b0C and \u00b10.020 \u00b0C at 425 \u00b0C.<\/p>\n<p class=\"isSelectedEnd\">For higher temperatures, the <strong>ADT 878-700<\/strong> provides a range from <strong>33 \u00b0C to 700 \u00b0C<\/strong>. Its display accuracy is \u00b10.20 \u00b0C at 33 \u00b0C and 425 \u00b0C and \u00b10.25 \u00b0C at 660 \u00b0C. Stability ranges from \u00b10.010 \u00b0C at 100 \u00b0C to \u00b10.030 \u00b0C at 700 \u00b0C. A special feature of this model is its integrated automatic function for <strong>annealing PRTs<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The <strong>ADT 878-1210<\/strong> extends the series into the high temperature range. This thermocouple calibration furnace operates from <strong>100 \u00b0C to 1,210 \u00b0C<\/strong> and achieves a display accuracy of <strong>\u00b11.5 \u00b0C across the entire range<\/strong>. Its multi zone temperature control is designed to provide a highly stable and uniform heat source for thermocouple calibration.<\/p>\n<p class=\"isSelectedEnd\">A key feature of the ADT 878 series is the optional <strong>Process Calibrator Option, PC<\/strong>. It adds an input for an external reference PRT and two measurement channels for devices under test. These channels support resistance thermometers, thermocouples, current, voltage and switches. Documentation functions and a full HART communicator are also available.<\/p>\n<p class=\"isSelectedEnd\">This transforms the temperature source into a comprehensive temperature calibration workstation. Setpoint, reference probe and devices under test can be handled within a single system. Calibration tasks can be documented and results stored as As Found and As Left data.<\/p>\n<p class=\"isSelectedEnd\">Another important feature is the <strong>Self Calibration function<\/strong>. An external reference probe can be used to automatically check and readjust the internal control sensor. This can reduce the influence of long term drift of the internal sensor.<\/p>\n<p class=\"isSelectedEnd\"><strong>europascal<\/strong> supports you in selecting the appropriate ADT 878 model, suitable inserts and reference thermometers. For the regular metrological traceability of your temperature calibrators and temperature probes, you can also use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul data-spread=\"false\">\n<li>Reference dry well calibrator for demanding temperature calibrations<\/li>\n<li>Overall series temperature range from <strong>\u221240 \u00b0C to 1,210 \u00b0C<\/strong><\/li>\n<li>Four temperature variants<\/li>\n<li>ADT 878-160 from \u221240 \u00b0C to 160 \u00b0C<\/li>\n<li>ADT 878-425 from 33 \u00b0C to 425 \u00b0C<\/li>\n<li>ADT 878-700 from 33 \u00b0C to 700 \u00b0C<\/li>\n<li>ADT 878-1210 from 100 \u00b0C to 1,210 \u00b0C<\/li>\n<li>Display accuracy down to \u00b10.1 \u00b0C<\/li>\n<li>Stability down to \u00b10.005 \u00b0C<\/li>\n<li>Excellent axial and radial temperature uniformity<\/li>\n<li>Interchangeable inserts<\/li>\n<li>Large color touchscreen<\/li>\n<li>Control using an internal or external reference probe<\/li>\n<li>Automatic self calibration<\/li>\n<li>Optional process calibrator functions<\/li>\n<li>RTD and thermocouple measurement<\/li>\n<li>Current and voltage measurement with PC option<\/li>\n<li>HART communication with PC option<\/li>\n<li>Calibration task documentation<\/li>\n<li>WiFi and Bluetooth capability<\/li>\n<li>ISO\/IEC 17025 accredited calibration with measurement data included<\/li>\n<li>Automatic water triple point function with the ADT 878-160<\/li>\n<li>Automatic PRT annealing function with the ADT 878-700<\/li>\n<\/ul>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878 Reference Dry Well Calibrator<\/strong> is particularly suitable for applications requiring not only a stable heat source but also low measurement uncertainty and excellent temperature uniformity.<\/p>\n<p class=\"isSelectedEnd\">During comparison calibration, the reference thermometer and device under test are inserted into the dry well insert. Once the required setpoint has been reached and sufficient stabilization time has elapsed, the readings of the reference and device under test can be compared.<\/p>\n<p class=\"isSelectedEnd\">With the optional process calibrator configuration, these tasks can be performed directly with the ADT 878. The external reference probe can be measured while two device under test channels are processed simultaneously.<\/p>\n<p class=\"isSelectedEnd\">This makes the series suitable for resistance thermometers, Pt100 and Pt1000 probes, thermocouples, temperature transmitters, temperature switches and digital thermometers.<\/p>\n<h2>Flexible Expansion<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878<\/strong> can be adapted to different calibration requirements using various inserts, reference probes and the optional process calibrator configuration.<\/p>\n<p class=\"isSelectedEnd\">With the PC option, two additional device under test channels are available in addition to the reference input. Supported measurements include RTDs, thermocouples, mA and voltage. Switch testing is also possible.<\/p>\n<p class=\"isSelectedEnd\">The platform additionally supports data logging, automated test procedures and HART communication. This enables the dry well to be integrated into automated and documenting calibration processes.<\/p>\n<h2>Additel ADT 878 Series Models<\/h2>\n<h3>Additel ADT 878-160<\/h3>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878-160<\/strong> operates from <strong>\u221240 \u00b0C to 160 \u00b0C<\/strong>. Its display accuracy is \u00b10.1 \u00b0C over the entire range, with a 30 minute stability of \u00b10.005 \u00b0C.<\/p>\n<p class=\"isSelectedEnd\">A special feature is the optional automatic realization of a <strong>water triple point<\/strong>. Together with the ADT878-TPW-KIT, the calibrator can automatically realize a water triple point cell and subsequently maintain its temperature. This can be used, for example, to check the drift of a PRT.<\/p>\n<h3>Additel ADT 878-425<\/h3>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878-425<\/strong> offers a temperature range from <strong>33 \u00b0C to 425 \u00b0C<\/strong> and a display accuracy of \u00b10.2 \u00b0C across the entire range.<\/p>\n<p class=\"isSelectedEnd\">Its stability is \u00b10.010 \u00b0C at 100 \u00b0C, \u00b10.015 \u00b0C at 225 \u00b0C and \u00b10.020 \u00b0C at 425 \u00b0C.<\/p>\n<p class=\"isSelectedEnd\">This makes the model particularly suitable for high quality comparison calibrations of industrial resistance thermometers, reference probes and temperature transmitters.<\/p>\n<h3>Additel ADT 878-700<\/h3>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878-700<\/strong> extends the operating range from <strong>33 \u00b0C to 700 \u00b0C<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">Display accuracy is \u00b10.20 \u00b0C at 33 \u00b0C and 425 \u00b0C and \u00b10.25 \u00b0C at 660 \u00b0C. Stability is \u00b10.010 \u00b0C at 100 \u00b0C, \u00b10.020 \u00b0C at 425 \u00b0C and \u00b10.030 \u00b0C at 700 \u00b0C.<\/p>\n<p class=\"isSelectedEnd\">A special feature is the integrated <strong>automatic PRT annealing function<\/strong>. Preconfigured procedures define temperature, annealing time and cooling rate. Custom procedures can also be created.<\/p>\n<h3>Additel ADT 878-1210<\/h3>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878-1210<\/strong> is the high temperature version for <strong>100 \u00b0C to 1,210 \u00b0C<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The unit is specifically designed as a thermocouple calibration furnace. Display accuracy is <strong>\u00b11.5 \u00b0C across the entire range<\/strong>. Multi zone temperature control combines three zone control with Additel&#8217;s Advanced Adaptive Control to improve stability and temperature uniformity within the working area.<\/p>\n<p class=\"isSelectedEnd\">Interchangeable metal inserts allow adaptation to different thermocouples and device diameters.<\/p>\n<h2>Technical Highlights<\/h2>\n<p class=\"isSelectedEnd\"><strong>Overall temperature range:<\/strong> \u221240 \u00b0C to 1,210 \u00b0C<\/p>\n<p class=\"isSelectedEnd\"><strong>ADT 878-160:<\/strong> \u221240 \u00b0C to 160 \u00b0C<\/p>\n<p class=\"isSelectedEnd\"><strong>ADT 878-425:<\/strong> 33 \u00b0C to 425 \u00b0C<\/p>\n<p class=\"isSelectedEnd\"><strong>ADT 878-700:<\/strong> 33 \u00b0C to 700 \u00b0C<\/p>\n<p class=\"isSelectedEnd\"><strong>ADT 878-1210:<\/strong> 100 \u00b0C to 1,210 \u00b0C<\/p>\n<p class=\"isSelectedEnd\"><strong>Best display accuracy:<\/strong> \u00b10.1 \u00b0C<\/p>\n<p class=\"isSelectedEnd\"><strong>Best stability:<\/strong> \u00b10.005 \u00b0C<\/p>\n<p class=\"isSelectedEnd\"><strong>Reference probe:<\/strong> Connectable<\/p>\n<p class=\"isSelectedEnd\"><strong>External reference control:<\/strong> Available<\/p>\n<p class=\"isSelectedEnd\"><strong>Self Calibration:<\/strong> Available<\/p>\n<p class=\"isSelectedEnd\"><strong>Process Calibrator:<\/strong> Optional<\/p>\n<p class=\"isSelectedEnd\"><strong>HART:<\/strong> With PC option<\/p>\n<p class=\"isSelectedEnd\"><strong>Documentation:<\/strong> With PC option<\/p>\n<p class=\"isSelectedEnd\"><strong>Display:<\/strong> Color touchscreen<\/p>\n<p class=\"isSelectedEnd\"><strong>Communication:<\/strong> WiFi and Bluetooth capable<\/p>\n<p class=\"isSelectedEnd\"><strong>Calibration:<\/strong> ISO\/IEC 17025 accredited calibration with measurement data included<\/p>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>ADT 878-160<\/th>\n<th>ADT 878-425<\/th>\n<th>ADT 878-700<\/th>\n<th>ADT 878-1210<\/th>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u221240 to 160 \u00b0C<\/td>\n<td>33 to 425 \u00b0C<\/td>\n<td>33 to 700 \u00b0C<\/td>\n<td>100 to 1,210 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Reference dry well<\/td>\n<td>Reference dry well<\/td>\n<td>Reference dry well<\/td>\n<td>Reference calibration furnace<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<td>\u00b10.2 \u00b0C<\/td>\n<td>Up to \u00b10.25 \u00b0C<\/td>\n<td>\u00b11.5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability<\/td>\n<td>\u00b10.005 \u00b0C<\/td>\n<td>Up to \u00b10.020 \u00b0C<\/td>\n<td>Up to \u00b10.030 \u00b0C<\/td>\n<td>High temperature specification<\/td>\n<\/tr>\n<tr>\n<td>Interchangeable inserts<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>External reference<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>With PC option<\/td>\n<\/tr>\n<tr>\n<td>Process Calibrator Option<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>HART option<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Special feature<\/td>\n<td>Water triple point<\/td>\n<td>Wide operating range<\/td>\n<td>PRT annealing<\/td>\n<td>Multi zone control<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>High Precision Reference Temperature Calibration<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878<\/strong> is designed for applications where the performance of a conventional dry well calibrator is not sufficient.<\/p>\n<p class=\"isSelectedEnd\">The ADT 878-160&#8217;s stability of <strong>\u00b10.005 \u00b0C<\/strong> demonstrates the reference level performance of the series. Additel also specifies both axial and radial temperature uniformity.<\/p>\n<p class=\"isSelectedEnd\">For demanding comparison calibrations, an external reference probe can be positioned directly next to the device under test. This allows the actual temperature at the measurement location to be determined.<\/p>\n<h2>Automatic Self Calibration<\/h2>\n<p class=\"isSelectedEnd\">An important function of the <strong>Additel ADT 878<\/strong> is automatic self calibration.<\/p>\n<p class=\"isSelectedEnd\">An external reference probe is used to check the internal control sensor. The calibrator can perform the procedure largely automatically.<\/p>\n<p class=\"isSelectedEnd\">This can reduce the influence of long term drift of the internal sensor and improve confidence in measurements using the internal reference.<\/p>\n<h2>Process Calibrator and HART<\/h2>\n<p class=\"isSelectedEnd\">With the optional <strong>PC configuration<\/strong>, the ADT 878 becomes a comprehensive temperature calibration workstation.<\/p>\n<p class=\"isSelectedEnd\">One reference PRT and two devices under test can be connected. The device channels support RTDs, thermocouples, mA, voltage and switches.<\/p>\n<p class=\"isSelectedEnd\">A full HART communicator, task management, As Found and As Left documentation and data logging are also available.<\/p>\n<p class=\"isSelectedEnd\">This is particularly useful for temperature transmitters because the heat source, reference measurement and electrical signal evaluation can be combined within one system.<\/p>\n<h2>Automatic Water Triple Point Realization<\/h2>\n<p class=\"isSelectedEnd\">A special feature of the <strong>ADT 878-160<\/strong> is its support for the optional <strong>ADT878-TPW-KIT<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The system can automatically realize a water triple point cell and subsequently maintain it in the reference dry well. This function can be used for regular drift checks of high quality PRT reference thermometers.<\/p>\n<h2>Automatic PRT Annealing<\/h2>\n<p class=\"isSelectedEnd\">The <strong>ADT 878-700<\/strong> provides an automatic annealing function.<\/p>\n<p class=\"isSelectedEnd\">Annealing can be used with high quality platinum resistance thermometers to reduce mechanical and thermal stresses and improve sensor stability.<\/p>\n<p class=\"isSelectedEnd\">The ADT 878-700 includes preconfigured programs for this purpose. Users can also define custom temperature, time and cooling profiles.<\/p>\n<h2>europascal Calibration Service<\/h2>\n<p class=\"isSelectedEnd\">Reliable and traceable temperature measurements require both reference probes and temperature calibrators to be calibrated regularly.<\/p>\n<p class=\"isSelectedEnd\">Through the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>, temperature calibrators, resistance thermometers, thermocouples, temperature transmitters and other temperature measuring instruments can be metrologically calibrated.<\/p>\n<p class=\"isSelectedEnd\">europascal can also assist you in selecting the appropriate <strong>Additel ADT 878<\/strong>, suitable inserts and reference probes and in configuring a complete temperature calibration workstation.<\/p>\n<h2>Why Choose the Additel ADT 878?<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878 Reference Dry Well Calibrator<\/strong> combines the convenient operation of a dry well calibrator with performance designed for demanding reference calibrations.<\/p>\n<p class=\"isSelectedEnd\">Together, the four models cover a temperature range from <strong>\u221240 \u00b0C to 1,210 \u00b0C<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">For particularly precise applications, the ADT 878-160 provides stability down to \u00b10.005 \u00b0C. The ADT 878-425 extends the range to 425 \u00b0C. The ADT 878-700 reaches 700 \u00b0C and additionally offers automatic PRT annealing. For high temperature thermocouples, the ADT 878-1210 extends the series to 1,210 \u00b0C.<\/p>\n<p class=\"isSelectedEnd\">The optional process calibrator configuration with reference input, two device under test channels, HART, data logging and documentation considerably expands the available applications.<\/p>\n<p class=\"isSelectedEnd\">This makes the <strong>Additel ADT 878 series<\/strong> particularly suitable for calibration laboratories with demanding requirements for stability, temperature uniformity, automation and documentation.<\/p>\n<h2>Typical Calibration Applications with the Additel ADT 878<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878<\/strong> is particularly suitable for calibration and testing of:<\/p>\n<ul data-spread=\"false\">\n<li>Reference PRTs<\/li>\n<li>Pt100 temperature probes<\/li>\n<li>Pt1000 temperature probes<\/li>\n<li>Resistance thermometers<\/li>\n<li>Thermocouples<\/li>\n<li>Digital reference thermometers<\/li>\n<li>Temperature transmitters<\/li>\n<li>Temperature switches<\/li>\n<li>Industrial temperature probes<\/li>\n<li>High quality reference sensors<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The ADT 878-160 is particularly suitable for high accuracy applications at low and ambient temperatures. The ADT 878-425 covers a broad range of industrial applications. The ADT 878-700 is suitable for high temperature PRTs and thermocouples, while the ADT 878-1210 extends the series to thermocouple calibrations up to 1,210 \u00b0C.<\/p>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 878 series<\/strong> therefore provides a powerful platform for professional reference temperature calibration.<\/p>\n<p class=\"isSelectedEnd\"><strong>Discover more Additel products on the <\/strong><a href=\"https:\/\/europascal.de\/en\/brand\/additel\/\"><strong>europascal Additel product page<\/strong><\/a><strong>.<\/strong><\/p>\n<p class=\"isSelectedEnd\">Manufacturer information about the <strong>Additel ADT 878<\/strong> is available on the <a href=\"https:\/\/additel.com\/product-detail.html\/878-dry-well-temperature-calibrator\/\" target=\"_blank\" rel=\"noopener\">official Additel website<\/a>.<\/p>\n<p>Manufacturer information about the high temperature <strong>Additel ADT 878-1210<\/strong> is available on the <a href=\"https:\/\/additel.com\/product-detail.html\/875-dry-well-ultra-high-temperature-calibrator\/\" target=\"_blank\" rel=\"noopener\">official Additel 87X-1210 product page<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Additel-ADT-878-Reference-Dry-Well-Calibrators-20260112.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Downlaod Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Additel ADT 878 Reference Dry Well Calibrator<\/strong> is designed for high precision temperature calibration from <strong>\u221240 \u00b0C to 1,210 \u00b0C<\/strong>. Four models combine excellent stability and temperature uniformity with automatic self calibration, interchangeable inserts and a large color touchscreen. The optional Process Calibrator configuration adds an external reference input, two DUT channels, HART communication, data logging and calibration documentation.<\/p>\n","protected":false},"featured_media":3407,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[90],"product_cat":[1206,53],"product_tag":[3984,3985,3986,3987,3988,3989,3990,3991,3992,3922,3993,3994,3995,3996,3997,3998,3999,4000,4001,4002,4003,4004,4005,4006,4007],"class_list":["post-6289","product","type-product","status-publish","has-post-thumbnail","product_brand-additel","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-additel","product_tag-additel-adt-878","product_tag-additel-adt-878-1210","product_tag-additel-adt-878-160","product_tag-additel-adt-878-425","product_tag-additel-adt-878-700","product_tag-adt-878","product_tag-dry-well-kalibrator","product_tag-hart-temperaturkalibrator","product_tag-kalibrierlabor","product_tag-prt-annealing","product_tag-prt-kalibrieren","product_tag-pt100-kalibrieren","product_tag-referenz-temperaturkalibrator","product_tag-referenz-trockenblockkalibrator","product_tag-temperaturfuehler-kalibrieren","product_tag-temperaturkalibrator","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-temperaturtransmitter-kalibrieren","product_tag-thermoelement-kalibrieren","product_tag-thermoelement-kalibrierofen","product_tag-trockenblockkalibrator","product_tag-wasser-tripelpunkt","product_tag-widerstandsthermometer-kalibrieren","pa_bauart-tisch","pa_funktion-nur-heizen","pa_genauigkeit-15c","pa_hart-kommunikation-ja","pa_kanaele-strom-spannung","pa_messbereich-1120c","pa_pc-version-ja","pa_schnittstelle-usb-a-usb-b-rj45-wifi-bluetooth","pa_stabilitaet-01c","pa_strom-versorgung-230v","pa_temperaturbereich-100c-bis-1210c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3407"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6289"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6289"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6289"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}