{"id":6309,"date":"2026-09-08T08:48:56","date_gmt":"2026-09-08T08:48:56","guid":{"rendered":"https:\/\/europascal.de\/product\/additel-adt-875\/"},"modified":"2026-09-22T07:07:51","modified_gmt":"2026-09-22T07:07:51","slug":"additel-adt-875","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-adt-875\/","title":{"rendered":"Additel ADT 875 Versatile Dry Well Calibrator"},"content":{"rendered":"<p>The <strong>Additel ADT 875 Dry Well Calibrator<\/strong> is a powerful and versatile temperature calibrator designed for precise and efficient calibration of temperature probes, thermometers, temperature transmitters and other temperature measuring instruments. With the <strong>ADT 875-155, ADT 875-350, ADT 875-660 and ADT 875-1210<\/strong> models, the product family covers an exceptionally wide overall temperature range from <strong>\u221240 \u00b0C to 1,210 \u00b0C<\/strong>. This makes the Additel ADT 875 series a flexible platform for numerous applications in calibration laboratories, quality assurance, production, maintenance, research and development.<\/p>\n<p>The <strong>Additel ADT 875<\/strong> combines high temperature stability and excellent temperature uniformity with a robust and portable design. Unlike a liquid calibration bath, a dry well calibrator does not require calibration oil. Devices under test are inserted into an interchangeable metal insert, which is controlled by the calibrator to the required temperature. This allows temperature probes to be calibrated or tested cleanly, quickly and with minimal preparation.<\/p>\n<p>Four versions are available for different temperature ranges. The <strong>ADT 875-155<\/strong> operates from <strong>\u221240 \u00b0C to 155 \u00b0C<\/strong>, the <strong>ADT 875-350<\/strong> from <strong>33 \u00b0C to 350 \u00b0C<\/strong> and the <strong>ADT 875-660<\/strong> from <strong>33 \u00b0C to 660 \u00b0C<\/strong>. For particularly high temperatures, the <strong>ADT 875-1210<\/strong> extends the product family as a thermocouple calibration furnace with a range from <strong>100 \u00b0C to 1,210 \u00b0C<\/strong>.<\/p>\n<p>The combination of several models allows calibration laboratories to cover a very wide temperature range using a consistent product family. The ADT 875-155 can be used for low temperature and ambient temperature applications, the ADT 875-350 for industrial temperature probes, the ADT 875-660 for higher process temperatures and the ADT 875-1210 for high temperature thermocouples.<\/p>\n<p>The three traditional dry well models provide excellent metrological performance. The <strong>ADT 875-155<\/strong> achieves a display accuracy of <strong>\u00b10.18 \u00b0C across its entire range<\/strong>, while the ADT 875-350 provides <strong>\u00b10.2 \u00b0C across its entire range<\/strong>. For the ADT 875-660, the specified display accuracy includes \u00b10.3 \u00b0C at 33 \u00b0C and 420 \u00b0C and \u00b10.5 \u00b0C at 660 \u00b0C.<\/p>\n<p>Temperature source stability is also crucial for professional calibration. Additel specifies a 30 minute stability of <strong>\u00b10.01 \u00b0C<\/strong> for the ADT 875-155. The ADT 875-350 provides <strong>\u00b10.02 \u00b0C<\/strong>, while the ADT 875-660 achieves values between <strong>\u00b10.02 \u00b0C and \u00b10.04 \u00b0C<\/strong>, depending on the operating temperature.<\/p>\n<p>The calibrators use interchangeable inserts. This allows different probe diameters to be accommodated and the dry well to be adapted to the devices under test. Additel offers various preconfigured inserts as well as customized solutions. This is particularly useful for laboratories calibrating different resistance thermometers, thermocouples and temperature transmitters.<\/p>\n<p>The <strong>ADT 875-1210<\/strong> uses a specialized concept for high temperature applications. Additel uses multi zone temperature control to reduce temperature gradients within the working area of the calibration furnace. Interchangeable metal inserts provide flexibility for different devices under test, even at high temperatures.<\/p>\n<p>For applications involving particularly short temperature probes, Additel also offers a dedicated <strong>Short Probe Calibration Kit<\/strong> for the ADT 875-155. It is designed to improve the calibration of temperature probes and transmitters with limited immersion depth.<\/p>\n<p>According to the manufacturer documentation, every ADT 875 is supplied with an <strong>ISO\/IEC 17025 accredited calibration with measurement data<\/strong>. For regular metrological traceability of your temperature calibrators and temperature probes, you can also use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>. europascal can assist you in selecting the appropriate temperature range, suitable inserts and reference probes.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul data-spread=\"false\">\n<li>Dry well calibrator for professional temperature calibration<\/li>\n<li>Product family covering <strong>\u221240 \u00b0C to 1,210 \u00b0C<\/strong><\/li>\n<li>Four temperature variants available<\/li>\n<li>ADT 875-155 from \u221240 \u00b0C to 155 \u00b0C<\/li>\n<li>ADT 875-350 from 33 \u00b0C to 350 \u00b0C<\/li>\n<li>ADT 875-660 from 33 \u00b0C to 660 \u00b0C<\/li>\n<li>ADT 875-1210 from 100 \u00b0C to 1,210 \u00b0C<\/li>\n<li>High temperature stability<\/li>\n<li>Excellent axial and radial temperature uniformity<\/li>\n<li>Interchangeable metal inserts<\/li>\n<li>Different bore configurations for various probe diameters<\/li>\n<li>Robust and portable design<\/li>\n<li>Color touchscreen<\/li>\n<li>Optional Short Probe Calibration Kit for the ADT 875-155<\/li>\n<li>Custom temperature ranges available for the 155, 350 and 660 models<\/li>\n<li>ISO\/IEC 17025 accredited calibration with measurement data included<\/li>\n<li>Suitable for laboratory and mobile applications<\/li>\n<\/ul>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p>The <strong>Additel ADT 875 Dry Well Calibrator<\/strong> is ideal for users who need to calibrate temperature probes quickly, cleanly and reproducibly.<\/p>\n<p>Unlike liquid baths, no liquid calibration medium is required. This eliminates filling, draining and cleaning a calibration bath as well as selecting suitable calibration fluids for different temperature ranges.<\/p>\n<p>The device under test is inserted into the appropriate bore of the metal insert. The required temperature setpoint is then selected. Once the heat source has stabilized, the device under test can be compared with an external reference thermometer where required.<\/p>\n<p>Typical devices under test include resistance thermometers, Pt100 and Pt1000 probes, thermocouples, digital thermometers, temperature transmitters and temperature switches.<\/p>\n<h2>Flexible Expansion<\/h2>\n<p>An important advantage of the <strong>Additel ADT 875<\/strong> is the use of interchangeable inserts. This allows the same dry well calibrator to be used with temperature probes of different diameters.<\/p>\n<p>Additel offers several standard inserts as well as customized bore configurations. Inserts are selected according to the respective temperature model and application.<\/p>\n<p>Suitable PRT reference probes and adapters are also available for reference measurements. Available accessories include Additel reference PRTs and Smart Connector solutions such as the 9070, 9071 and 9072.<\/p>\n<h2>Additel ADT 875 Series Models<\/h2>\n<h3>Additel ADT 875-155<\/h3>\n<p>The <strong>Additel ADT 875-155<\/strong> is the low temperature version of the series. Its temperature range extends from <strong>\u221240 \u00b0C to 155 \u00b0C<\/strong>. Display accuracy is <strong>\u00b10.18 \u00b0C across the entire range<\/strong>, while 30 minute stability is <strong>\u00b10.01 \u00b0C<\/strong>.<\/p>\n<p>This makes the ADT 875-155 particularly suitable for Pt100 probes, temperature transmitters, digital thermometers and sensors that require calibration at negative temperatures as well as around ambient temperature.<\/p>\n<p>A dedicated Short Probe Calibration Kit is available for short sensors.<\/p>\n<h3>Additel ADT 875-350<\/h3>\n<p>The <strong>Additel ADT 875-350<\/strong> operates from <strong>33 \u00b0C to 350 \u00b0C<\/strong>. Its display accuracy is <strong>\u00b10.2 \u00b0C across the entire temperature range<\/strong>, while 30 minute stability is <strong>\u00b10.02 \u00b0C<\/strong>.<\/p>\n<p>This model is an excellent solution for typical industrial temperature calibration applications involving resistance thermometers, temperature transmitters and process probes.<\/p>\n<h3>Additel ADT 875-660<\/h3>\n<p>The <strong>Additel ADT 875-660<\/strong> extends the temperature range from <strong>33 \u00b0C to 660 \u00b0C<\/strong>. Display accuracy is \u00b10.3 \u00b0C at 33 \u00b0C and 420 \u00b0C and \u00b10.5 \u00b0C at 660 \u00b0C. Depending on the operating point, specified stability ranges between <strong>\u00b10.02 \u00b0C and \u00b10.04 \u00b0C<\/strong>.<\/p>\n<p>This model is particularly suitable for industrial high temperature sensors and thermocouples.<\/p>\n<h3>Additel ADT 875-1210<\/h3>\n<p>The <strong>Additel ADT 875-1210<\/strong> is the high temperature model in the product family and operates from <strong>100 \u00b0C to 1,210 \u00b0C<\/strong>. Additel classifies this version as a thermocouple calibration furnace. The instrument features multi zone temperature control and interchangeable metal inserts.<\/p>\n<p>The ADT 875-1210 is particularly suitable for calibrating and testing thermocouples at high temperatures.<\/p>\n<h2>Technical Highlights<\/h2>\n<p>Depending on the selected model, the <strong>Additel ADT 875<\/strong> provides:<\/p>\n<p><strong>Overall temperature range:<\/strong> \u221240 \u00b0C to 1,210 \u00b0C<\/p>\n<p><strong>ADT 875-155:<\/strong> \u221240 \u00b0C to 155 \u00b0C<\/p>\n<p><strong>ADT 875-350:<\/strong> 33 \u00b0C to 350 \u00b0C<\/p>\n<p><strong>ADT 875-660:<\/strong> 33 \u00b0C to 660 \u00b0C<\/p>\n<p><strong>ADT 875-1210:<\/strong> 100 \u00b0C to 1,210 \u00b0C<\/p>\n<p><strong>ADT 875-155 stability:<\/strong> \u00b10.01 \u00b0C<\/p>\n<p><strong>ADT 875-350 stability:<\/strong> \u00b10.02 \u00b0C<\/p>\n<p><strong>ADT 875-660 stability:<\/strong> up to \u00b10.04 \u00b0C depending on temperature<\/p>\n<p><strong>Immersion depth for ADT 875-155, 350 and 660:<\/strong> 150 mm<\/p>\n<p><strong>Inserts:<\/strong> Interchangeable<\/p>\n<p><strong>Operation:<\/strong> Color touchscreen<\/p>\n<p><strong>Calibration:<\/strong> ISO\/IEC 17025 accredited calibration with measurement data included<\/p>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>ADT 875-155<\/th>\n<th>ADT 875-350<\/th>\n<th>ADT 875-660<\/th>\n<th>ADT 875-1210<\/th>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u221240 to 155 \u00b0C<\/td>\n<td>33 to 350 \u00b0C<\/td>\n<td>33 to 660 \u00b0C<\/td>\n<td>100 to 1,210 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Device principle<\/td>\n<td>Dry well<\/td>\n<td>Dry well<\/td>\n<td>Dry well<\/td>\n<td>Calibration furnace<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy<\/td>\n<td>\u00b10.18 \u00b0C<\/td>\n<td>\u00b10.2 \u00b0C<\/td>\n<td>Up to \u00b10.5 \u00b0C<\/td>\n<td>Model specific specification<\/td>\n<\/tr>\n<tr>\n<td>Stability<\/td>\n<td>\u00b10.01 \u00b0C<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<td>\u00b10.02 to \u00b10.04 \u00b0C<\/td>\n<td>High stability multi zone control<\/td>\n<\/tr>\n<tr>\n<td>Immersion depth<\/td>\n<td>150 mm<\/td>\n<td>150 mm<\/td>\n<td>150 mm<\/td>\n<td>Separate furnace geometry<\/td>\n<\/tr>\n<tr>\n<td>Interchangeable inserts<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>ISO\/IEC 17025 calibration<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The specifications for the 155, 350 and 660 models are based on the current ADT 875 manufacturer documentation. The ADT 875-1210 is listed by Additel on a separate product platform together with the ADT 878-1210.<\/p>\n<h2>Precise Temperature Calibration Without a Liquid Bath<\/h2>\n<p>The <strong>Additel ADT 875 Dry Well Calibrator<\/strong> provides clean and straightforward temperature calibration. The device under test is inserted directly into a suitable metal insert.<\/p>\n<p>No oils or other calibration fluids are required. This can significantly reduce preparation and cleaning requirements, particularly for mobile applications and environments where devices under test change frequently.<\/p>\n<p>For applications requiring lower measurement uncertainty, an external reference probe can additionally be used. Instead of relying exclusively on the internal display of the dry well, the actual temperature can therefore be measured close to the device under test.<\/p>\n<h2>europascal Calibration Service<\/h2>\n<p>Even high quality temperature calibrators require regular metrological traceability. europascal provides comprehensive calibration capabilities for temperature measuring equipment.<\/p>\n<p>Through the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>, temperature calibrators, resistance thermometers, thermocouples and other temperature measuring instruments can be calibrated.<\/p>\n<p>europascal can also assist you in selecting the appropriate <strong>Additel ADT 875<\/strong>, suitable inserts and a suitable reference thermometer for your application.<\/p>\n<h2>Why Choose the Additel ADT 875?<\/h2>\n<p>The <strong>Additel ADT 875<\/strong> provides an exceptionally wide selection of temperature ranges within one product family.<\/p>\n<p>The ADT 875-155 covers applications down to \u221240 \u00b0C. The ADT 875-350 is suitable for typical industrial temperature calibrations up to 350 \u00b0C. The ADT 875-660 extends the operating range up to 660 \u00b0C.<\/p>\n<p>For particularly high temperatures, the ADT 875-1210 provides a maximum temperature of <strong>1,210 \u00b0C<\/strong>.<\/p>\n<p>Interchangeable inserts provide flexible adaptation to different probe diameters. At the same time, high temperature stability and temperature uniformity support reproducible calibration results.<\/p>\n<p>The ADT 875 family therefore provides a versatile solution for organizations that need to calibrate temperature sensors across different temperature ranges while using a consistent instrument platform.<\/p>\n<h2>Typical Calibration Applications with the Additel ADT 875<\/h2>\n<p>The <strong>Additel ADT 875 Dry Well Calibrator<\/strong> is particularly suitable for calibration and testing of:<\/p>\n<ul data-spread=\"false\">\n<li>Pt100 temperature probes<\/li>\n<li>Pt1000 temperature probes<\/li>\n<li>Resistance thermometers<\/li>\n<li>Thermocouples<\/li>\n<li>Digital thermometers<\/li>\n<li>Temperature transmitters<\/li>\n<li>Temperature switches<\/li>\n<li>Industrial temperature probes<\/li>\n<li>Reference thermometers<\/li>\n<li>Process sensors<\/li>\n<\/ul>\n<p>The 155, 350 and 660 models allow users to select the most appropriate instrument for typical industrial temperature ranges. For thermocouples and other high temperature applications, the ADT 875-1210 extends the operating range up to 1,210 \u00b0C.<\/p>\n<p>This makes the <strong>Additel ADT 875 series<\/strong> suitable for calibration laboratories, quality assurance, production, maintenance, pharmaceutical applications, food processing, energy, mechanical engineering as well as research and development.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/additel\/\">Discover more Additel products here.<\/a><\/p>\n<p>Manufacturer information about the <strong>Additel ADT 875<\/strong> is available on the <a href=\"https:\/\/additel.com\/product-detail.html\/875-dry-well-temperature-calibrator\/\" target=\"_blank\" rel=\"noopener\">official Additel website<\/a>.<\/p>\n<p>Manufacturer information about the high temperature <strong>ADT 875-1210<\/strong> is available on the <a href=\"https:\/\/additel.com\/product-detail.html\/875-dry-well-ultra-high-temperature-calibrator\/\" target=\"_blank\" rel=\"noopener\">official Additel product page for the 87X-1210 series<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Additel-ADT-875-Dry-Well-Calibrators-20260112.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Additel ADT 875 Dry Well Calibrator<\/strong> provides precise and efficient temperature calibration from <strong>\u221240 \u00b0C to 1,210 \u00b0C<\/strong>. Four models combine high temperature stability, excellent temperature uniformity, interchangeable inserts and convenient touchscreen operation. The versatile series is ideal for calibrating Pt100 probes, resistance thermometers, thermocouples, temperature transmitters and other industrial temperature sensors.<\/p>\n","protected":false},"featured_media":3409,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[90],"product_cat":[1206,53],"product_tag":[3984,4035,4036,4037,4038,4039,4040,3991,3922,4041,3995,3998,3999,4000,4001,4002,3929,4003,4005,4007],"class_list":["post-6309","product","type-product","status-publish","has-post-thumbnail","product_brand-additel","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-additel","product_tag-additel-adt-875","product_tag-additel-adt-875-1210","product_tag-additel-adt-875-155","product_tag-additel-adt-875-350","product_tag-additel-adt-875-660","product_tag-adt-875","product_tag-dry-well-kalibrator","product_tag-kalibrierlabor","product_tag-kalibrierofen","product_tag-pt100-kalibrieren","product_tag-temperaturfuehler-kalibrieren","product_tag-temperaturkalibrator","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-temperaturtransmitter-kalibrieren","product_tag-thermoelement-kalibrator","product_tag-thermoelement-kalibrieren","product_tag-trockenblockkalibrator","product_tag-widerstandsthermometer-kalibrieren","pa_bauart-tisch","pa_funktion-heizen-kuehlen","pa_genauigkeit-02c","pa_hart-kommunikation-ja","pa_kanaele-strom-spannung-schaltertest","pa_messbereich-minus-bis--200c","pa_pc-version-ja","pa_schnittstelle-usb-b-rj45-wifi-bluetooth","pa_stabilitaet-005c","pa_strom-versorgung-230v","pa_temperaturbereich-40c-bis-155c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6309","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3409"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6309"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6309"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6309"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6309"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}