{"id":6326,"date":"2026-07-17T16:55:13","date_gmt":"2026-07-17T16:55:13","guid":{"rendered":"https:\/\/europascal.de\/product\/additel-adt-282\/"},"modified":"2026-09-22T09:59:29","modified_gmt":"2026-09-22T09:59:29","slug":"additel-adt-282","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-adt-282\/","title":{"rendered":"Additel ADT 282 Dual-Channel Reference Thermometer Readout"},"content":{"rendered":"<p class=\"isSelectedEnd\">The <strong>Additel ADT 282 Dual Channel Reference Thermometer<\/strong> is a high precision reference thermometer designed for professional temperature measurement and calibration applications. This compact handheld instrument combines excellent metrological performance with a modern user interface and enables simultaneous measurement of two temperature probes.<\/p>\n<p class=\"isSelectedEnd\">Thanks to its two independent analog input channels, the ADT 282 is ideal for direct comparison measurements. Both channels can be displayed simultaneously, while the temperature difference between the two channels can also be calculated and displayed directly. This makes the instrument particularly suitable for temperature sensor calibration as well as stability and uniformity measurements of temperature baths, furnaces and dry well calibrators.<\/p>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> supports both resistance thermometers and thermocouples. Its integrated sensor library includes numerous industrial and metrological sensor types, including Pt100, Pt25, Pt10, various industrial RTD characteristics and a wide range of thermocouple types.<\/p>\n<p class=\"isSelectedEnd\">At <strong>europascal<\/strong>, you can find professional solutions for temperature measurement and temperature calibration. Additional instruments and accessories are available in the <a href=\"https:\/\/europascal.de\/en\/product-category\/temperature\/\">Temperature Measurement<\/a> section. For regular calibration of your reference thermometers and temperature probes, you can also use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul data-spread=\"false\">\n<li>Two independent temperature measurement channels<\/li>\n<li>Supports RTDs and thermocouples<\/li>\n<li>Temperature resolution down to 0.001 \u00b0C<\/li>\n<li>Resistance resolution down to 0.1 m\u03a9<\/li>\n<li>Voltage resolution down to 0.1 \u00b5V<\/li>\n<li>RTD temperature measurement range from \u2212200 \u00b0C to 850 \u00b0C<\/li>\n<li>Thermocouple measurement range up to approximately 1,800 \u00b0C depending on sensor type<\/li>\n<li>ITS-90 support<\/li>\n<li>Callendar Van Dusen support<\/li>\n<li>Numerous industrial RTD characteristics<\/li>\n<li>15 thermocouple types<\/li>\n<li>User defined sensor characteristics<\/li>\n<li>Direct T1 minus T2 differential measurement<\/li>\n<li>Simultaneous display of both measurement channels<\/li>\n<li>Integrated statistics with minimum, maximum and average<\/li>\n<li>Extensive data logging functions<\/li>\n<li>Trend display directly on the instrument<\/li>\n<li>5 inch color touchscreen<\/li>\n<li>Bluetooth communication<\/li>\n<li>USB Type C interface<\/li>\n<li>Smart Probe connections<\/li>\n<li>Internal and external cold junction compensation<\/li>\n<li>Rugged IP67 enclosure<\/li>\n<li>Tested for drops from a height of one meter<\/li>\n<li>Rechargeable lithium battery<\/li>\n<li>ISO\/IEC 17025 accredited calibration with calibration data included according to the manufacturer<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The combination of high resolution, two measurement channels and extensive sensor support makes the <strong>Additel ADT 282 Dual Channel Reference Thermometer<\/strong> particularly attractive for calibration laboratories and demanding industrial temperature measurements.<\/p>\n<h2>Additel ADT 282 for Demanding Calibration Applications<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> was specifically developed for applications requiring high accuracy and reliable comparison measurements. A typical application is the calibration of temperature probes in liquid baths or dry well calibrators.<\/p>\n<p class=\"isSelectedEnd\">A reference probe can be connected to Channel 1 and the device under test to Channel 2. Both temperatures are displayed simultaneously. In addition, the temperature difference can be displayed directly as <strong>T1 minus T2<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">This function is particularly useful for:<\/p>\n<ul data-spread=\"false\">\n<li>Comparison calibrations<\/li>\n<li>Stability testing of temperature baths<\/li>\n<li>Temperature uniformity testing<\/li>\n<li>RTD sensor calibration<\/li>\n<li>Thermocouple calibration<\/li>\n<li>Dry well calibrator testing<\/li>\n<li>Temperature furnace testing<\/li>\n<li>Long term temperature recording<\/li>\n<li>Comparison of two reference probes<\/li>\n<li>Field calibration<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Additional temperature calibration solutions are available from <a href=\"https:\/\/europascal.de\/en\/\">europascal<\/a>.<\/p>\n<h2>Two Measurement Channels for Direct Comparison Measurements<\/h2>\n<p class=\"isSelectedEnd\">One of the most important features of the <strong>Additel ADT 282 Dual Channel Reference Thermometer<\/strong> is its two independent measurement channels.<\/p>\n<p class=\"isSelectedEnd\">Both channels support resistance thermometers and thermocouples. Two sensors can therefore be measured and compared simultaneously.<\/p>\n<p class=\"isSelectedEnd\">Users can select between several display modes:<\/p>\n<p class=\"isSelectedEnd\"><strong>Single Channel<\/strong><\/p>\n<p class=\"isSelectedEnd\"><strong>Dual Channel<\/strong><\/p>\n<p class=\"isSelectedEnd\"><strong>Differential Measurement T1 minus T2<\/strong><\/p>\n<p class=\"isSelectedEnd\">This flexibility is particularly useful for calibration applications. The difference between the reference probe and device under test can be displayed directly on the screen.<\/p>\n<p class=\"isSelectedEnd\">This eliminates the need for a separate calculation and allows the user to immediately see the temperature deviation between the two sensors.<\/p>\n<h2>Precise RTD Measurement<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> supports a wide range of resistance thermometers.<\/p>\n<p class=\"isSelectedEnd\">The RTD sensor measurement range extends approximately from:<\/p>\n<p class=\"isSelectedEnd\"><strong>\u2212200 \u00b0C to 850 \u00b0C<\/strong><\/p>\n<p class=\"isSelectedEnd\">Supported sensor types and characteristics include:<\/p>\n<ul data-spread=\"false\">\n<li>ITS-90<\/li>\n<li>Callendar Van Dusen<\/li>\n<li>Pt100 with \u03b1 = 0.00385<\/li>\n<li>Pt10<\/li>\n<li>Pt25<\/li>\n<li>Pt50<\/li>\n<li>Pt100 with different characteristics<\/li>\n<li>Cu100<\/li>\n<li>Cu50<\/li>\n<li>Cu10<\/li>\n<li>Ni100<\/li>\n<li>Ni120<\/li>\n<li>User defined RTD characteristics<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Resistance measurement covers a range from <strong>0 to 400 \u03a9<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">Resolution is as high as:<\/p>\n<p class=\"isSelectedEnd\"><strong>0.1 m\u03a9<\/strong><\/p>\n<p class=\"isSelectedEnd\">or:<\/p>\n<p class=\"isSelectedEnd\"><strong>0.001 \u00b0C<\/strong><\/p>\n<p class=\"isSelectedEnd\">RTD sensors are measured using a <strong>4 wire connection<\/strong>, which largely compensates for the influence of lead resistance.<\/p>\n<p class=\"isSelectedEnd\">According to the manufacturer, the measurement current is <strong>1 mA with current reversal<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">This current reversal technique helps reduce the influence of thermoelectric EMFs and improves measurement stability.<\/p>\n<h2>Thermocouple Measurement<\/h2>\n<p class=\"isSelectedEnd\">In addition to resistance thermometers, the <strong>Additel ADT 282<\/strong> supports a wide range of thermocouple types.<\/p>\n<p class=\"isSelectedEnd\">These include:<\/p>\n<ul data-spread=\"false\">\n<li>S<\/li>\n<li>R<\/li>\n<li>B<\/li>\n<li>K<\/li>\n<li>N<\/li>\n<li>E<\/li>\n<li>J<\/li>\n<li>T<\/li>\n<li>C<\/li>\n<li>D<\/li>\n<li>G<\/li>\n<li>L<\/li>\n<li>U<\/li>\n<li>LR<\/li>\n<li>A<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Standard thermocouples and user defined characteristics can also be used.<\/p>\n<p class=\"isSelectedEnd\">The electrical thermocouple measurement range is approximately:<\/p>\n<p class=\"isSelectedEnd\"><strong>\u221210 mV to 75 mV<\/strong><\/p>\n<p class=\"isSelectedEnd\">Resolution is as high as:<\/p>\n<p class=\"isSelectedEnd\"><strong>0.1 \u00b5V<\/strong><\/p>\n<p class=\"isSelectedEnd\">or:<\/p>\n<p class=\"isSelectedEnd\"><strong>0.001 \u00b0C<\/strong><\/p>\n<p class=\"isSelectedEnd\">Depending on the thermocouple type, measurements are possible over a temperature range of approximately <strong>\u2212270 \u00b0C to 1,800 \u00b0C<\/strong>.<\/p>\n<h2>Cold Junction Compensation<\/h2>\n<p class=\"isSelectedEnd\">Reliable cold junction compensation is essential when measuring thermocouples.<\/p>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> supports several methods:<\/p>\n<ul data-spread=\"false\">\n<li>Internal cold junction compensation<\/li>\n<li>External cold junction compensation<\/li>\n<li>Manual input<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">According to the manufacturer, the internal cold junction has a specification of approximately <strong>\u00b10.15 \u00b0C<\/strong> over the temperature range from \u221210 \u00b0C to 50 \u00b0C.<\/p>\n<p class=\"isSelectedEnd\">Depending on the required measurement uncertainty, users can therefore decide whether to use the internal compensation or an external reference.<\/p>\n<h2>Smart Probe Connections<\/h2>\n<p class=\"isSelectedEnd\">For resistance thermometers, the <strong>Additel ADT 282<\/strong> features intelligent <strong>6 pin LEMO connections<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">This Smart Probe technology enables sensor information and calibration coefficients to be managed together with the corresponding probe.<\/p>\n<p class=\"isSelectedEnd\">Important information such as ITS-90 coefficients or Callendar Van Dusen parameters can therefore be directly assigned to the sensor being used.<\/p>\n<p class=\"isSelectedEnd\">A Probe Lock function can also be used. This allows a specific probe to be associated with the measurement channel with which it was calibrated as a system.<\/p>\n<p class=\"isSelectedEnd\">This reduces the risk of incorrect sensor configuration and supports traceable measurements.<\/p>\n<h2>Reference Measurement Technology<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> uses high precision ratio measurement technology to improve stability and long term performance.<\/p>\n<p class=\"isSelectedEnd\">Current reversal techniques are used for resistance measurements, helping to reduce unwanted thermoelectric voltages.<\/p>\n<p class=\"isSelectedEnd\">Ratio measurement technology also compensates for offset influences of the analog to digital converter.<\/p>\n<p class=\"isSelectedEnd\">This technology provides high measurement stability even in a portable handheld instrument and supports the use of the ADT 282 as a professional reference thermometer.<\/p>\n<h2>Data Logging and Trend Display<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> provides extensive data logging functionality.<\/p>\n<p class=\"isSelectedEnd\">Measurement values can be automatically stored over extended periods. At the same time, trend curves can be displayed directly on the instrument.<\/p>\n<p class=\"isSelectedEnd\">This makes the ADT 282 particularly suitable for:<\/p>\n<ul data-spread=\"false\">\n<li>Stability measurements<\/li>\n<li>Long term monitoring<\/li>\n<li>Temperature profiles<\/li>\n<li>Comparison of two sensors<\/li>\n<li>Uniformity investigations<\/li>\n<li>Monitoring calibration baths<\/li>\n<li>Monitoring dry well calibrators<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">Statistical values including:<\/p>\n<p class=\"isSelectedEnd\"><strong>Minimum \/ Maximum \/ Average<\/strong><\/p>\n<p class=\"isSelectedEnd\">can also be calculated and displayed directly on the instrument.<\/p>\n<p class=\"isSelectedEnd\">According to Additel, internal storage capacity is up to <strong>8 GB<\/strong>.<\/p>\n<h2>Technical Highlights<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> features a <strong>5 inch TFT color touchscreen<\/strong> with a resolution of 480 \u00d7 800 pixels.<\/p>\n<p class=\"isSelectedEnd\">Operation is similar to a modern smartphone using a capacitive touchscreen interface.<\/p>\n<p class=\"isSelectedEnd\">The instrument provides Bluetooth BLE and an isolated USB Type C interface.<\/p>\n<p class=\"isSelectedEnd\">Bluetooth allows the ADT 282 to be monitored using the Additel Mobile Link app from a distance of up to approximately 20 meters.<\/p>\n<p class=\"isSelectedEnd\">The rugged enclosure is rated <strong>IP67<\/strong> and, according to the manufacturer, has been tested for drops from a height of one meter.<\/p>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Specification<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Additel<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>ADT 282<\/td>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Dual Channel Reference Thermometer<\/td>\n<\/tr>\n<tr>\n<td>Measurement channels<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Sensors<\/td>\n<td>RTD and thermocouple<\/td>\n<\/tr>\n<tr>\n<td>RTD temperature range<\/td>\n<td>\u2212200 \u00b0C to 850 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple range<\/td>\n<td>Approx. \u2212270 \u00b0C to 1,800 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Resistance range<\/td>\n<td>0 to 400 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resistance resolution<\/td>\n<td>Down to 0.1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Temperature resolution<\/td>\n<td>Down to 0.001 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple resolution<\/td>\n<td>Down to 0.1 \u00b5V<\/td>\n<\/tr>\n<tr>\n<td>RTD connection<\/td>\n<td>4 wire<\/td>\n<\/tr>\n<tr>\n<td>RTD measurement current<\/td>\n<td>1 mA with current reversal<\/td>\n<\/tr>\n<tr>\n<td>Temperature units<\/td>\n<td>\u00b0C, \u00b0F and K<\/td>\n<\/tr>\n<tr>\n<td>Statistics<\/td>\n<td>Minimum, maximum and average<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>5 inch TFT color touchscreen<\/td>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>480 \u00d7 800 pixels<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td>Bluetooth BLE and USB Type C<\/td>\n<\/tr>\n<tr>\n<td>Protection rating<\/td>\n<td>IP67<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>\u221210 \u00b0C to 50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Specified temperature range<\/td>\n<td>10 \u00b0C to 30 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>\u221220 \u00b0C to 70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td>0 to 95 % RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td>Warm-up time<\/td>\n<td>10 minutes<\/td>\n<\/tr>\n<tr>\n<td>Battery<\/td>\n<td>Rechargeable lithium, 6,600 mAh<\/td>\n<\/tr>\n<tr>\n<td>Battery life<\/td>\n<td>Typically approx. 16 hours<\/td>\n<\/tr>\n<tr>\n<td>Charging time<\/td>\n<td>Approx. 4 to 6 hours<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 0.65 kg<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>ISO\/IEC 17025 accredited according to manufacturer<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"isSelectedEnd\">Complete technical specifications are available in the <a href=\"https:\/\/additel.com\/download\/datasheet\/282\/282_Dual_Channel_Reference_Thermometer_Readouts.pdf\" target=\"_blank\" rel=\"noopener\">official Additel ADT 282 data sheet<\/a>.<\/p>\n<h2>Ideal for Stability and Uniformity Measurements<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> is particularly well suited for testing temperature sources.<\/p>\n<p class=\"isSelectedEnd\">For example, when testing a calibration bath, a reference thermometer can be measured using Channel 1 while Channel 2 measures a second sensor.<\/p>\n<p class=\"isSelectedEnd\">The data logging function allows both temperatures to be recorded over an extended period.<\/p>\n<p class=\"isSelectedEnd\">This provides valuable information about:<\/p>\n<ul data-spread=\"false\">\n<li>Stability<\/li>\n<li>Temperature drift over time<\/li>\n<li>Temperature difference<\/li>\n<li>Repeatability<\/li>\n<li>Uniformity<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">of a temperature source.<\/p>\n<p class=\"isSelectedEnd\">The same functionality can also be used for comparison measurements with dry well calibrators or thermocouple calibration furnaces.<\/p>\n<h2>Why Choose the Additel ADT 282?<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282 Dual Channel Reference Thermometer<\/strong> combines the accuracy of a high quality laboratory reference thermometer with the flexibility of a portable handheld instrument.<\/p>\n<p class=\"isSelectedEnd\">The two independent measurement channels are particularly useful because the reference probe and device under test can be measured simultaneously.<\/p>\n<p class=\"isSelectedEnd\">The direct <strong>T1 minus T2 differential display<\/strong> significantly simplifies comparison calibrations.<\/p>\n<p class=\"isSelectedEnd\">With support for ITS-90, Callendar Van Dusen, numerous industrial RTD characteristics and a wide range of thermocouple types, the instrument covers a broad spectrum of temperature measurement applications.<\/p>\n<p class=\"isSelectedEnd\">Data logging, trend display and statistical functions reduce the need for additional instruments or software.<\/p>\n<p class=\"isSelectedEnd\">The rugged IP67 enclosure and rechargeable lithium battery also enable mobile use outside the calibration laboratory.<\/p>\n<p class=\"isSelectedEnd\">According to the manufacturer, Additel supplies the ADT 282 with an <strong>ISO\/IEC 17025 accredited calibration including calibration data<\/strong>.<\/p>\n<h2>Typical Calibration Applications with the Additel ADT 282<\/h2>\n<p class=\"isSelectedEnd\">The <strong>Additel ADT 282<\/strong> is suitable for numerous professional temperature measurement and calibration applications.<\/p>\n<p class=\"isSelectedEnd\">Typical devices under test and applications include:<\/p>\n<ul data-spread=\"false\">\n<li>Pt100 resistance thermometers<\/li>\n<li>Pt25 reference thermometers<\/li>\n<li>Pt10 sensors<\/li>\n<li>Thermocouples<\/li>\n<li>Temperature transmitters in combination with suitable sensors<\/li>\n<li>Reference probes<\/li>\n<li>Calibration baths<\/li>\n<li>Liquid baths<\/li>\n<li>Dry well calibrators<\/li>\n<li>Temperature furnaces<\/li>\n<li>Thermocouple calibration furnaces<\/li>\n<li>Stability measurements<\/li>\n<li>Uniformity measurements<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">The two measurement channels make the instrument particularly suitable for conventional comparison calibrations.<\/p>\n<p class=\"isSelectedEnd\">The reference probe is connected to one channel and the device under test to the second channel. Both measurement values and their difference can be viewed simultaneously.<\/p>\n<p class=\"isSelectedEnd\">At <strong>europascal<\/strong>, you can obtain the Additel ADT 282 together with suitable temperature probes and additional measurement equipment for professional calibration applications. Additional solutions are available in the <a href=\"https:\/\/europascal.de\/en\/product-category\/temperature\/\">Temperature Measurement<\/a> section or through the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p class=\"isSelectedEnd\"><a href=\"https:\/\/europascal.de\/en\/brand\/additel\/\">Discover more Additel products here.<\/a><\/p>\n<p><a href=\"https:\/\/www.additel.com\/product-detail.html\/282-dual-channel-reference-thermometer-readout\/\" target=\"_blank\" rel=\"noopener\">Manufacturer information about the Additel ADT 282 is available on the official Additel website.<\/a><\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Additel-ADT-282-Dual-Channel-Reference-Thermometer-Readouts-20260130.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Additel ADT 282 Dual Channel Reference Thermometer<\/strong> is a high precision handheld instrument for professional temperature measurement and comparison calibration. Two independent channels support RTDs and thermocouples and enable simultaneous measurement as well as direct <strong>T1 minus T2 differential measurement<\/strong>. With resolution down to 0.001 \u00b0C, ITS-90 and Callendar Van Dusen support, data logging, Smart Probe technology, Bluetooth and an IP67 enclosure, the ADT 282 is ideal for demanding laboratory and field calibration applications.<\/p>\n","protected":false},"featured_media":6327,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[90],"product_cat":[57,53],"product_tag":[4100,4101,4102,4103,4104,3920,4095,4105,3922,4106,4107,4108,4109,4110,4111,4112,3998,4000,4113,4114,4005,4115],"class_list":["post-6326","product","type-product","status-publish","has-post-thumbnail","product_brand-additel","product_cat-temperature-indicators","product_cat-temperature","product_tag-additel-282","product_tag-additel-adt-282","product_tag-adt-282","product_tag-callendar-van-dusen","product_tag-datenlogger-temperatur","product_tag-europascal","product_tag-its-90","product_tag-kalibrierbad","product_tag-kalibrierlabor","product_tag-praezisionsthermometer","product_tag-pt100-messgeraet","product_tag-pt25-messgeraet","product_tag-referenz-temperaturmessgeraet","product_tag-referenzthermometer","product_tag-rtd-messgeraet","product_tag-temperatur-referenz","product_tag-temperaturfuehler-kalibrieren","product_tag-temperaturkalibrierung","product_tag-temperaturmessung","product_tag-thermoelement-messgeraet","product_tag-trockenblockkalibrator","product_tag-zweikanal-thermometer","pa_bauart-hand","pa_genauigkeit-0006-c","pa_kanaele-zweikanal-referenz-thermometer-anzeige","pa_schnittstelle-bluetooth-usb","pa_strom-versorgung-akku","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6326","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6327"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6326"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6326"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6326"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6326"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}