{"id":6417,"date":"2026-07-17T16:39:15","date_gmt":"2026-07-17T16:39:15","guid":{"rendered":"https:\/\/europascal.de\/product\/geo-calibration-modell4000-exp\/"},"modified":"2026-09-24T11:17:59","modified_gmt":"2026-09-24T11:17:59","slug":"geo-calibration-modell4000-exp","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/geo-calibration-modell4000-exp\/","title":{"rendered":"GEO Calibration Model 4000 EXP Versatile Humidity Calibrator"},"content":{"rendered":"<p data-pm-slice=\"1 1 []\"><strong>GEO Calibration Model 4000 EXP<\/strong> is a versatile humidity calibrator and temperature generator designed for professional calibration of larger humidity measuring instruments, data loggers, chart recorders and probes. Its vertical design, large <strong>30-liter square calibration chamber<\/strong> and temperature-controlled door make the system particularly suitable for demanding laboratory applications and calibration equipment that cannot easily be accommodated in conventional compact humidity generators.<\/p>\n<p>The Model 4000 EXP generates controlled relative humidity and temperature conditions for professional comparison calibration. At <strong>23 \u00b0C<\/strong>, the system provides a controlled relative humidity range from <strong>10 % RH to 90 % RH<\/strong>. The temperature can be controlled within approximately <strong>\u00b15 \u00b0C of ambient temperature<\/strong>.<\/p>\n<p>The specified calibration system accuracy is <strong>\u00b13.0 % RH or better<\/strong> for relative humidity and <strong>\u00b10.3 \u00b0C or better<\/strong> for temperature.<\/p>\n<p>A key feature of the <strong>GEO Calibration Model 4000 EXP<\/strong> is its temperature-controlled door. It is designed to reduce the influence of changes in external ambient temperature on the conditions inside the calibration chamber.<\/p>\n<p>Combined with automatic Ramp\/Soak functionality and a typical response time of approximately <strong>3 to 5 minutes<\/strong>, the Model 4000 EXP provides a practical solution for repeatable multipoint humidity calibration.<\/p>\n<p>At <strong>europascal<\/strong>, you receive professional solutions for humidity and temperature calibration. We can assist you in selecting the appropriate humidity generator, reference sensor and accessories for your calibration application.<\/p>\n<p>For regular calibration and metrological traceability of humidity and temperature measuring instruments, europascal also provides a professional <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul data-spread=\"false\">\n<li>Versatile humidity and temperature calibrator<\/li>\n<li>Vertical calibration chamber<\/li>\n<li>Large 30-liter square chamber<\/li>\n<li>Relative humidity range from 10 % RH to 90 % RH at 23 \u00b0C<\/li>\n<li>Temperature range approximately \u00b15 \u00b0C from ambient<\/li>\n<li>Relative humidity accuracy \u00b13.0 % RH or better<\/li>\n<li>Temperature accuracy \u00b10.3 \u00b0C or better<\/li>\n<li>PID-controlled humidity and temperature generation<\/li>\n<li>Temperature-controlled chamber door<\/li>\n<li>Temperature uniformity 0.3 \u00b0C at 23 \u00b0C<\/li>\n<li>Humidity uniformity 3.0 % RH at 23 \u00b0C<\/li>\n<li>Temperature stability 0.2 \u00b0C<\/li>\n<li>Humidity stability 1 % RH at 23 \u00b0C<\/li>\n<li>Temperature resolution 0.1 \u00b0C<\/li>\n<li>Humidity resolution 0.1 % RH<\/li>\n<li>Automatic Ramp\/Soak functionality<\/li>\n<li>Typical response time approximately 3 to 5 minutes<\/li>\n<li>Suitable for data logger calibration<\/li>\n<li>Suitable for chart recorder calibration<\/li>\n<li>Suitable for humidity probe calibration<\/li>\n<li>Designed to accommodate legacy hair hygrometers<\/li>\n<li>Particularly suitable for vertical calibration systems<\/li>\n<li>Designed for demanding environments<\/li>\n<li>Professional solution for calibration laboratories<\/li>\n<\/ul>\n<h2>GEO Calibration Model 4000 EXP for Professional Humidity Calibration<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> was developed for applications where conventional compact humidity calibrators do not provide sufficient chamber volume or the appropriate physical configuration.<\/p>\n<p>Its vertical design and large calibration chamber enable users to accommodate a variety of devices under test.<\/p>\n<p>Typical applications include:<\/p>\n<ul data-spread=\"false\">\n<li>Calibration laboratories<\/li>\n<li>In-house calibration laboratories<\/li>\n<li>Quality assurance<\/li>\n<li>Measuring equipment monitoring<\/li>\n<li>Environmental monitoring<\/li>\n<li>Pharmaceutical applications<\/li>\n<li>Food production and storage<\/li>\n<li>HVAC measurement<\/li>\n<li>Building automation<\/li>\n<li>Research and development<\/li>\n<li>Industrial process measurement<\/li>\n<li>Production monitoring<\/li>\n<li>Data logger calibration<\/li>\n<li>Chart recorder calibration<\/li>\n<li>Humidity probe calibration<\/li>\n<\/ul>\n<p>The Model 4000 EXP is particularly useful for devices that require a larger chamber or need to be positioned vertically during calibration.<\/p>\n<h2>Large 30-Liter Calibration Chamber<\/h2>\n<p>One of the main advantages of the <strong>GEO Calibration Model 4000 EXP<\/strong> is its large calibration chamber.<\/p>\n<p>The square chamber provides a volume of approximately:<\/p>\n<p><strong>30 liters<\/strong><\/p>\n<p>This provides considerably more space than compact portable humidity generators.<\/p>\n<p>The additional chamber volume is particularly useful when calibrating larger devices or several suitable measuring instruments.<\/p>\n<p>Typical devices under test include:<\/p>\n<ul data-spread=\"false\">\n<li>Data loggers<\/li>\n<li>Chart recorders<\/li>\n<li>Humidity probes<\/li>\n<li>Temperature and humidity sensors<\/li>\n<li>Hygrometers<\/li>\n<li>Environmental monitoring instruments<\/li>\n<li>Legacy hair hygrometers<\/li>\n<\/ul>\n<p>The square geometry also simplifies positioning of instruments that do not fit conveniently into smaller cylindrical calibration chambers.<\/p>\n<h2>Relative Humidity from 10 % to 90 % RH<\/h2>\n<p>At an operating temperature of <strong>23 \u00b0C<\/strong>, the <strong>GEO Calibration Model 4000 EXP<\/strong> provides a controlled humidity range from:<\/p>\n<p><strong>10 % RH to 90 % RH<\/strong><\/p>\n<p>This covers a large proportion of typical humidity calibration requirements.<\/p>\n<p>The available humidity range changes with temperature.<\/p>\n<p>Typical specified ranges include:<\/p>\n<p><strong>At 18 \u00b0C: 10 % to 70 % RH<\/strong><\/p>\n<p><strong>At 23 \u00b0C: 10 % to 90 % RH<\/strong><\/p>\n<p><strong>At 28 \u00b0C: 10 % to 70 % RH<\/strong><\/p>\n<p>This relationship is important when planning calibration points because the achievable relative humidity depends on the selected chamber temperature.<\/p>\n<h2>Temperature Control Around Ambient Conditions<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> also provides active temperature control.<\/p>\n<p>Its controlled temperature range is approximately:<\/p>\n<p><strong>Ambient temperature \u00b15 \u00b0C<\/strong><\/p>\n<p>This makes the Model 4000 EXP particularly suitable for humidity calibrations performed around typical laboratory or operating temperatures.<\/p>\n<p>Temperature control is especially important in relative humidity calibration because relative humidity is highly dependent on temperature.<\/p>\n<p>Even relatively small temperature differences between the reference sensor and device under test can influence the measurement result.<\/p>\n<p>The controlled chamber therefore provides a more suitable environment for professional comparison calibration than uncontrolled ambient conditions.<\/p>\n<h2>Humidity Accuracy of \u00b13.0 % RH<\/h2>\n<p>The specified relative humidity calibration system accuracy is:<\/p>\n<p><strong>\u00b13.0 % RH or better<\/strong><\/p>\n<p>This makes the <strong>GEO Calibration Model 4000 EXP<\/strong> suitable for numerous industrial humidity calibration and verification applications.<\/p>\n<p>When determining the measurement uncertainty of an actual calibration, however, the generator specification is only one contribution.<\/p>\n<p>The complete uncertainty evaluation may also include:<\/p>\n<ul data-spread=\"false\">\n<li>Reference sensor calibration uncertainty<\/li>\n<li>Humidity stability<\/li>\n<li>Spatial humidity uniformity<\/li>\n<li>Temperature stability<\/li>\n<li>Temperature gradients<\/li>\n<li>Resolution<\/li>\n<li>Repeatability<\/li>\n<li>Device under test characteristics<\/li>\n<li>Sensor positioning<\/li>\n<li>Stabilization effects<\/li>\n<\/ul>\n<p>These contributions should be evaluated according to the laboratory&#8217;s calibration procedure and required measurement uncertainty.<\/p>\n<h2>Temperature Accuracy of \u00b10.3 \u00b0C<\/h2>\n<p>The specified temperature calibration system accuracy is:<\/p>\n<p><strong>\u00b10.3 \u00b0C or better<\/strong><\/p>\n<p>Temperature and humidity are controlled simultaneously by the system.<\/p>\n<p>This is particularly useful when calibrating combined temperature and humidity instruments such as environmental data loggers.<\/p>\n<p>Instead of evaluating humidity under uncontrolled temperature conditions, the Model 4000 EXP provides a defined calibration environment for both quantities.<\/p>\n<h2>Temperature-Controlled Door<\/h2>\n<p>A distinctive feature of the <strong>GEO Calibration Model 4000 EXP<\/strong> is its temperature-controlled door.<\/p>\n<p>Large calibration chambers can be sensitive to external environmental influences, particularly around access points and chamber doors.<\/p>\n<p>The temperature-controlled door is designed to help maintain the internal temperature and reduce the influence of changes in ambient conditions.<\/p>\n<p>This feature is particularly useful when large devices under test are positioned inside the chamber and stable conditions need to be maintained throughout the calibration process.<\/p>\n<h2>PID-Controlled Calibration Environment<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> uses PID control for humidity and temperature generation.<\/p>\n<p>The controller continuously evaluates the actual chamber conditions and adjusts the system to maintain the selected setpoints.<\/p>\n<p>The specified temperature uniformity is:<\/p>\n<p><strong>0.3 \u00b0C at 23 \u00b0C<\/strong><\/p>\n<p>The specified relative humidity uniformity is:<\/p>\n<p><strong>3.0 % RH at 23 \u00b0C<\/strong><\/p>\n<p>Temperature stability is specified as:<\/p>\n<p><strong>0.2 \u00b0C<\/strong><\/p>\n<p>Relative humidity stability is specified as:<\/p>\n<p><strong>1 % RH at 23 \u00b0C<\/strong><\/p>\n<p>These characteristics are important when reference sensors and devices under test are compared within the calibration chamber.<\/p>\n<h2>Automatic Ramp\/Soak Function<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> supports automatic <strong>Ramp\/Soak<\/strong> operation.<\/p>\n<p>Ramp\/Soak functionality enables controlled transitions between different temperature and humidity setpoints and allows defined conditions to be maintained for a specified period.<\/p>\n<p>This can be particularly useful for multipoint calibration.<\/p>\n<p>Instead of manually changing each calibration condition, a sequence can be created to move through several measurement points.<\/p>\n<p>This supports more efficient and reproducible calibration workflows.<\/p>\n<h2>Typical Ramp Rates<\/h2>\n<p>The Model 4000 EXP is designed for controlled transitions between calibration conditions.<\/p>\n<p>Typical rates are approximately:<\/p>\n<p><strong>Temperature, low to high: 1 \u00b0C\/min<\/strong><\/p>\n<p><strong>Humidity, low to high: 1 % RH\/min<\/strong><\/p>\n<p><strong>Humidity, high to low: approximately 1 % RH\/min<\/strong><\/p>\n<p>The actual time required to reach a stable calibration condition depends on the selected setpoints, ambient conditions, chamber loading and response characteristics of the devices under test.<\/p>\n<h2>Fast Response<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> is specified with typical response times of approximately:<\/p>\n<p><strong>3 to 5 minutes<\/strong><\/p>\n<p>Fast system response can reduce waiting periods when several calibration points need to be processed.<\/p>\n<p>However, the response time of the generator should not be confused with the stabilization time required for the complete calibration.<\/p>\n<p>A large data logger, chart recorder or humidity probe may require additional time to reach thermal and humidity equilibrium with the chamber.<\/p>\n<p>Measurement values should therefore only be recorded after both the reference and device under test have sufficiently stabilized.<\/p>\n<h2>Data Logger Calibration<\/h2>\n<p>The large chamber makes the <strong>GEO Calibration Model 4000 EXP<\/strong> particularly suitable for calibration of environmental data loggers.<\/p>\n<p>Data loggers are frequently used to monitor temperature and humidity in:<\/p>\n<ul data-spread=\"false\">\n<li>Warehouses<\/li>\n<li>Pharmaceutical storage<\/li>\n<li>Laboratories<\/li>\n<li>Production areas<\/li>\n<li>Cleanrooms<\/li>\n<li>Transport systems<\/li>\n<li>Museums<\/li>\n<li>Archives<\/li>\n<li>Food storage facilities<\/li>\n<\/ul>\n<p>Several suitable data loggers can be exposed to the same controlled environment.<\/p>\n<p>This makes the Model 4000 EXP particularly useful for organizations that need to regularly verify environmental monitoring equipment.<\/p>\n<h2>Chart Recorder Calibration<\/h2>\n<p>The <strong>30-liter chamber<\/strong> also provides sufficient space for many chart recorders.<\/p>\n<p>Chart recorders continue to be used in applications where a direct graphical record of environmental conditions is required.<\/p>\n<p>The Model 4000 EXP allows suitable chart recorders to be exposed to defined humidity and temperature conditions.<\/p>\n<p>Their indications can then be compared with a calibrated reference system.<\/p>\n<h2>Support for Legacy Hair Hygrometers<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> was also engineered to support legacy hair hygrometers.<\/p>\n<p>These instruments use the dimensional change of hygroscopic material as the sensing principle for relative humidity.<\/p>\n<p>Their mechanical construction can make calibration in compact chambers difficult.<\/p>\n<p>The larger vertical chamber of the Model 4000 EXP provides a more suitable environment for these types of instruments.<\/p>\n<p>This makes the calibrator useful for laboratories that need to maintain and calibrate both modern electronic humidity sensors and older mechanical hygrometers.<\/p>\n<h2>Ideal for Vertical Calibration Systems<\/h2>\n<p>The vertical construction of the <strong>GEO Calibration Model 4000 EXP<\/strong> distinguishes it from many conventional benchtop humidity generators.<\/p>\n<p>Some instruments and sensors need to remain in a particular orientation during measurement or calibration.<\/p>\n<p>The vertical chamber configuration provides additional flexibility for these applications.<\/p>\n<p>GEO Calibration specifically identifies calibration of vertical systems as one of the intended applications for the Model 4000 EXP.<\/p>\n<h2>Comparison Calibration<\/h2>\n<p>A typical calibration with the <strong>GEO Calibration Model 4000 EXP<\/strong> is performed using the comparison method.<\/p>\n<p>A calibrated reference humidity sensor and the device under test are placed inside the controlled chamber.<\/p>\n<p>A defined relative humidity and temperature setpoint is selected.<\/p>\n<p>After sufficient stabilization, the reference value and indication of the device under test are recorded.<\/p>\n<p>The deviation can then be calculated.<\/p>\n<p>This procedure can be repeated at several humidity points, for example:<\/p>\n<ul data-spread=\"false\">\n<li>Low relative humidity<\/li>\n<li>Medium relative humidity<\/li>\n<li>High relative humidity<\/li>\n<\/ul>\n<p>The exact calibration points should be selected according to the measurement range, application and required calibration procedure.<\/p>\n<h2>Technical Highlights<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> combines a large calibration volume with controlled humidity and temperature generation:<\/p>\n<ul data-spread=\"false\">\n<li>30-liter square calibration chamber<\/li>\n<li>Vertical chamber design<\/li>\n<li>Relative humidity range 10 % to 90 % RH at 23 \u00b0C<\/li>\n<li>Temperature range ambient \u00b15 \u00b0C<\/li>\n<li>Humidity accuracy \u00b13.0 % RH or better<\/li>\n<li>Temperature accuracy \u00b10.3 \u00b0C or better<\/li>\n<li>PID controller<\/li>\n<li>Temperature uniformity 0.3 \u00b0C at 23 \u00b0C<\/li>\n<li>Humidity uniformity 3.0 % RH at 23 \u00b0C<\/li>\n<li>Temperature stability 0.2 \u00b0C<\/li>\n<li>Humidity stability 1 % RH at 23 \u00b0C<\/li>\n<li>Temperature resolution 0.1 \u00b0C<\/li>\n<li>Humidity resolution 0.1 % RH<\/li>\n<li>Automatic Ramp\/Soak<\/li>\n<li>Typical response time 3 to 5 minutes<\/li>\n<li>Temperature-controlled door<\/li>\n<li>Suitable for large calibration equipment<\/li>\n<li>Data logger calibration<\/li>\n<li>Chart recorder calibration<\/li>\n<li>Probe calibration<\/li>\n<li>Legacy hair hygrometer support<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>GEO Calibration Model 4000 EXP<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>GEO Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>4000 EXP<\/td>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Humidity and Temperature Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Chamber volume<\/td>\n<td>30 liters<\/td>\n<\/tr>\n<tr>\n<td>Chamber design<\/td>\n<td>Square, vertical<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>Ambient \u00b15 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidity range at 18 \u00b0C<\/td>\n<td>10 % to 70 % RH<\/td>\n<\/tr>\n<tr>\n<td>Humidity range at 23 \u00b0C<\/td>\n<td>10 % to 90 % RH<\/td>\n<\/tr>\n<tr>\n<td>Humidity range at 28 \u00b0C<\/td>\n<td>10 % to 70 % RH<\/td>\n<\/tr>\n<tr>\n<td>Humidity accuracy<\/td>\n<td>\u00b13.0 % RH or better<\/td>\n<\/tr>\n<tr>\n<td>Temperature accuracy<\/td>\n<td>\u00b10.3 \u00b0C or better<\/td>\n<\/tr>\n<tr>\n<td>Controller<\/td>\n<td>PID<\/td>\n<\/tr>\n<tr>\n<td>Temperature uniformity<\/td>\n<td>0.3 \u00b0C at 23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidity uniformity<\/td>\n<td>3.0 % RH at 23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>0.2 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidity stability<\/td>\n<td>1 % RH at 23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature resolution<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidity resolution<\/td>\n<td>0.1 % RH<\/td>\n<\/tr>\n<tr>\n<td>Automatic Ramp\/Soak<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Typical response time<\/td>\n<td>3\u20135 minutes<\/td>\n<\/tr>\n<tr>\n<td>Door<\/td>\n<td>Temperature controlled<\/td>\n<\/tr>\n<tr>\n<td>Typical applications<\/td>\n<td>Data loggers, chart recorders, probes, hair hygrometers<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>GEO Calibration Model 4000 EXP for Demanding Environments<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> is designed not only for conventional laboratory environments but also for demanding applications.<\/p>\n<p>Its temperature-controlled door helps reduce the influence of changes in external ambient temperature on the chamber conditions.<\/p>\n<p>This is particularly useful where environmental conditions are less stable than in a dedicated high-quality calibration laboratory.<\/p>\n<p>For reliable measurements, the installation environment should nevertheless always comply with the manufacturer&#8217;s operating requirements.<\/p>\n<h2>Why Choose the GEO Calibration Model 4000 EXP?<\/h2>\n<p>The <strong>GEO Calibration Model 4000 EXP<\/strong> provides a combination of large calibration volume, vertical construction and controlled temperature and humidity generation.<\/p>\n<p>Its <strong>30-liter square chamber<\/strong> accommodates larger devices that cannot easily be calibrated in compact humidity generators.<\/p>\n<p>A relative humidity range from <strong>10 % RH to 90 % RH at 23 \u00b0C<\/strong> covers a broad spectrum of typical industrial humidity calibration applications.<\/p>\n<p>The temperature-controlled door helps maintain consistent chamber conditions, while automatic Ramp\/Soak functionality supports repeatable multipoint calibration sequences.<\/p>\n<p>The Model 4000 EXP is particularly suitable for calibration of <strong>data loggers, chart recorders, humidity probes and legacy hair hygrometers<\/strong>.<\/p>\n<p>For calibration laboratories, quality assurance departments and organizations with larger environmental monitoring instruments, the system therefore provides a versatile solution for professional humidity calibration.<\/p>\n<p>At <strong>europascal<\/strong>, we can assist you in selecting the appropriate GEO Calibration humidity generator, reference sensor and accessories for your individual application.<\/p>\n<p>For regular calibration and metrological traceability of humidity sensors, data loggers, hygrometers and other measuring instruments, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p>Additional measurement and calibration solutions are available through the <a href=\"https:\/\/europascal.de\/en\/\">europascal English homepage<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/en\/\">Discover more GEO Calibration products and calibration solutions from europascal.<\/a><\/p>\n<p>Manufacturer information about the <strong>GEO Calibration Model 4000 EXP<\/strong> is available from the <a href=\"https:\/\/www.geocalibration.com\/\" target=\"_blank\" rel=\"noopener\">official GEO Calibration website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Geo-Calibration-Modell-4000EXP-Humidity-Generator-3.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p data-pm-slice=\"1 1 []\">The <strong>GEO Calibration Model 4000 EXP<\/strong> is a versatile humidity and temperature calibrator with a large <strong>30-liter vertical chamber<\/strong>. It provides a controlled range of <strong>10 % to 90 % RH at 23 \u00b0C<\/strong>, temperature control of <strong>ambient \u00b15 \u00b0C<\/strong>, automatic Ramp\/Soak functionality and a temperature-controlled door. Ideal for calibrating data loggers, chart recorders, humidity probes and larger measuring instruments.<\/p>\n","protected":false},"featured_media":6418,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4444],"product_cat":[69,68],"product_tag":[4497,4447,3920,4448,4385,4386,4387,4388,4451,4498,4499,4394,4395,4410,4500,4455,4456,4398,3999,4000],"class_list":["post-6417","product","type-product","status-publish","has-post-thumbnail","product_brand-geo-calibration","product_cat-humidity-calibrators","product_cat-humidity","product_tag-30-liter-kalibrierkammer","product_tag-datenlogger-kalibrieren","product_tag-europascal","product_tag-feuchte-und-temperaturkalibrator","product_tag-feuchtefuehler","product_tag-feuchtegenerator","product_tag-feuchtekalibrator","product_tag-feuchtekalibrierung","product_tag-geo-calibration","product_tag-geo-calibration-4000-exp","product_tag-geo-calibration-model-4000-exp","product_tag-hygrometer-kalibrieren","product_tag-kalibriertechnik","product_tag-klimakammer","product_tag-model-4000-exp","product_tag-pid-regelung","product_tag-ramp-soak","product_tag-relative-feuchte","product_tag-temperaturkalibrator","product_tag-temperaturkalibrierung","pa_data-logger-n","pa_design-tisch","pa_generator-ja","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6417","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6418"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6417"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6417"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6417"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6417"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}