{"id":6425,"date":"2026-07-17T14:34:30","date_gmt":"2026-07-17T14:34:30","guid":{"rendered":"https:\/\/europascal.de\/product\/europascal-bh2-1200b-dp\/"},"modified":"2026-09-24T11:52:39","modified_gmt":"2026-09-24T11:52:39","slug":"europascal-bh2-1200b-dp","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/europascal-bh2-1200b-dp\/","title":{"rendered":"europascal BH2-1200B Precise Dual-Piston Deadweight Tester"},"content":{"rendered":"<p data-pm-slice=\"1 1 []\"><strong>europascal BH2-1200B<\/strong> is a precise dual-piston deadweight tester designed for high-accuracy hydraulic pressure calibration over a wide pressure range from <strong>1 to 1,200 bar<\/strong>. The dual-piston design combines two piston-cylinder systems in one pressure balance, providing excellent flexibility for calibrating pressure gauges, digital pressure gauges, transmitters, transducers, sensors and pressure switches.<\/p>\n<p>The <strong>europascal BH2-1200B Dual-Piston<\/strong> version is particularly suitable for calibration laboratories that require both a low starting pressure and a maximum pressure of up to 1,200 bar within one mechanical pressure reference system.<\/p>\n<p>Its measurement principle is based on the fundamental relationship:<\/p>\n<p><strong>p = F \/ A<\/strong><\/p>\n<p>Calibrated masses generate a precisely defined force on the effective area of the piston-cylinder system. When the piston is in equilibrium, the resulting hydraulic pressure provides a highly stable reference value for comparison with the device under test.<\/p>\n<p>The use of <strong>two piston-cylinder systems<\/strong> allows the BH2-1200B to optimize the effective piston area for different portions of the pressure range. This provides a wider useful measurement range than the single-piston version while maintaining the advantages of a traditional deadweight tester.<\/p>\n<p>At <strong>europascal<\/strong>, we provide complete solutions for professional pressure calibration. In addition to pressure balances and pressure calibration equipment, we can assist you with suitable mass sets, adapters, pressure connections and accessories.<\/p>\n<p>For regular calibration and metrological traceability of pressure balances, pressure gauges, transmitters and pressure sensors, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul data-spread=\"false\">\n<li>Hydraulic dual-piston deadweight tester<\/li>\n<li>Two precision piston-cylinder systems<\/li>\n<li>Wide pressure range from 1 to 1,200 bar<\/li>\n<li>High-accuracy mechanical pressure reference<\/li>\n<li>Accuracy of 0.01 % of reading<\/li>\n<li>Enhanced accuracy up to 0.006 % available on request<\/li>\n<li>Lower starting pressure than the single-piston BH2-1200B<\/li>\n<li>Tungsten carbide pistons<\/li>\n<li>Precision piston-cylinder assemblies<\/li>\n<li>Hydraulic pressure generation<\/li>\n<li>H40 mineral oil as pressure medium<\/li>\n<li>Integrated pressure generator<\/li>\n<li>High repeatability<\/li>\n<li>Excellent long-term stability<\/li>\n<li>Suitable for pressure gauges<\/li>\n<li>Suitable for digital pressure gauges<\/li>\n<li>Suitable for pressure transmitters<\/li>\n<li>Suitable for pressure transducers<\/li>\n<li>Suitable for pressure sensors<\/li>\n<li>Suitable for pressure switches<\/li>\n<li>Different pressure units available<\/li>\n<li>Standard or local gravity configuration<\/li>\n<li>Optional motorization<\/li>\n<li>Optional piston-position visualization<\/li>\n<li>Optional calculator module<\/li>\n<li>Suitable for professional calibration laboratories<\/li>\n<li>Designed for industrial pressure metrology<\/li>\n<\/ul>\n<h2>Dual-Piston Pressure Calibration from 1 to 1,200 bar<\/h2>\n<p>The <strong>europascal BH2-1200B<\/strong> Dual-Piston version provides a wide hydraulic pressure range from:<\/p>\n<p><strong>1 to 1,200 bar<\/strong><\/p>\n<p>This broad range is one of the key advantages of the dual-piston configuration.<\/p>\n<p>A single piston-cylinder assembly optimized for high pressures cannot always provide the required performance at very low pressures. The dual-piston concept solves this problem by using two different effective piston areas.<\/p>\n<p>The larger-area piston is used for the lower pressure range, while the smaller-area piston provides the required capability for higher pressures.<\/p>\n<p>This enables the BH2-1200B to combine low-pressure capability with hydraulic pressure calibration up to 1,200 bar.<\/p>\n<h2>Two Piston-Cylinder Systems<\/h2>\n<p>The defining feature of the <strong>europascal BH2-1200B Dual-Piston Deadweight Tester<\/strong> is its use of two piston-cylinder assemblies.<\/p>\n<p>Each piston-cylinder system is optimized for a particular part of the overall pressure range.<\/p>\n<p>This provides several practical advantages:<\/p>\n<ul data-spread=\"false\">\n<li>Wider overall pressure range<\/li>\n<li>Lower minimum pressure<\/li>\n<li>Optimized mass loading<\/li>\n<li>Improved usability across the measurement range<\/li>\n<li>One pressure balance for low and high hydraulic pressures<\/li>\n<\/ul>\n<p>For calibration laboratories covering a wide range of pressure instruments, this can reduce the need for separate pressure balances.<\/p>\n<h2>How Does a Deadweight Tester Work?<\/h2>\n<p>The operating principle of the <strong>europascal BH2-1200B<\/strong> is based on:<\/p>\n<p><strong>p = F \/ A<\/strong><\/p>\n<p>where:<\/p>\n<p><strong>p<\/strong> = generated pressure<br \/>\n<strong>F<\/strong> = force acting on the piston<br \/>\n<strong>A<\/strong> = effective piston area<\/p>\n<p>Calibrated masses are placed on the selected piston system.<\/p>\n<p>The gravitational force generated by the masses acts on the effective area of the piston-cylinder assembly.<\/p>\n<p>Hydraulic pressure is then increased until the piston reaches its defined equilibrium or floating position.<\/p>\n<p>Under these conditions, the generated pressure can be determined from the applied force and the effective piston area, taking the relevant correction quantities into account.<\/p>\n<p>The generated reference pressure can then be compared directly with the indication of the device under test.<\/p>\n<h2>Advantages of the Dual-Piston Design<\/h2>\n<p>A pressure balance needs an appropriate relationship between piston area and applied masses.<\/p>\n<p>For lower pressures, a larger effective piston area is advantageous because sufficient force can be generated with practical mass values.<\/p>\n<p>At higher pressures, a smaller piston area allows very high pressures to be generated without requiring impractically large masses.<\/p>\n<p>The <strong>europascal BH2-1200B<\/strong> combines these two requirements using two piston-cylinder systems.<\/p>\n<p>The result is a highly flexible mechanical pressure reference covering an exceptionally broad hydraulic pressure range.<\/p>\n<h2>Accuracy of 0.01 % of Reading<\/h2>\n<p>The standard accuracy of the <strong>europascal BH2-1200B<\/strong> is:<\/p>\n<p><strong>0.01 % of reading<\/strong><\/p>\n<p>For particularly demanding pressure calibration applications, an enhanced accuracy of up to:<\/p>\n<p><strong>0.006 % of reading<\/strong><\/p>\n<p>is available on request.<\/p>\n<p>A percentage-of-reading specification is especially beneficial for a pressure balance covering a wide pressure range because the accuracy specification follows the generated pressure.<\/p>\n<p>This makes the dual-piston configuration particularly useful when pressure instruments with different measurement ranges need to be calibrated using the same reference system.<\/p>\n<h2>Hydraulic Pressure Generation<\/h2>\n<p>The <strong>europascal BH2-1200B<\/strong> uses hydraulic pressure generation.<\/p>\n<p>A manually operated pressure generator is used to pressurize the hydraulic system and bring the selected piston into its correct operating position.<\/p>\n<p>Fine pressure adjustment enables the operator to establish equilibrium between the applied masses and the hydraulic pressure.<\/p>\n<p>The device under test is connected to the same hydraulic pressure circuit and therefore experiences the reference pressure generated by the pressure balance.<\/p>\n<h2>H40 Oil as Pressure Medium<\/h2>\n<p>The standard pressure medium for the <strong>europascal BH2-1200B<\/strong> is:<\/p>\n<p><strong>H40 mineral oil<\/strong><\/p>\n<p>A suitable hydraulic fluid is essential for reliable operation of a high-pressure deadweight tester.<\/p>\n<p>The pressure medium transfers pressure between the pressure generator, piston-cylinder system and device under test.<\/p>\n<p>For accurate measurements, the hydraulic system should be correctly filled and free from excessive trapped air.<\/p>\n<p>Contamination of the fluid should also be avoided because particles can affect sensitive piston-cylinder assemblies and other components.<\/p>\n<h2>Calibration of Pressure Gauges<\/h2>\n<p>Pressure gauges are among the most common devices calibrated with a deadweight tester.<\/p>\n<p>The <strong>europascal BH2-1200B<\/strong> can generate a sequence of accurately defined hydraulic pressures across the measurement range of the device under test.<\/p>\n<p>Typical calibration sequences include several increasing pressure points followed by decreasing pressure points.<\/p>\n<p>The difference between the generated reference pressure and the indication of the pressure gauge can then be evaluated.<\/p>\n<p>Depending on the calibration procedure, this allows characteristics such as indication deviation, repeatability and hysteresis to be determined.<\/p>\n<h2>Calibration of Digital Pressure Gauges<\/h2>\n<p>High-accuracy digital pressure gauges can also be calibrated using the <strong>europascal BH2-1200B<\/strong>.<\/p>\n<p>The broad <strong>1 to 1,200 bar<\/strong> pressure range is particularly useful for laboratories calibrating digital gauges with different full-scale ranges.<\/p>\n<p>The appropriate piston-cylinder system and mass combination can be selected according to the required calibration pressure.<\/p>\n<p>This enables one pressure balance to cover numerous pressure gauge ranges.<\/p>\n<h2>Calibration of Pressure Transmitters<\/h2>\n<p>The BH2-1200B can also be used as a hydraulic reference for pressure transmitter calibration.<\/p>\n<p>The pressure balance generates the reference pressure while an appropriate electrical measuring instrument measures the transmitter output.<\/p>\n<p>For a conventional <strong>4\u201320 mA transmitter<\/strong>, for example, several pressure values can be generated and the corresponding current output recorded.<\/p>\n<p>The pressure and electrical measurements can then be evaluated together to determine transmitter performance.<\/p>\n<h2>Pressure Sensor and Transducer Calibration<\/h2>\n<p>Pressure sensors and transducers are used throughout industrial measurement systems.<\/p>\n<p>The <strong>europascal BH2-1200B<\/strong> provides a high-quality reference pressure for evaluating these devices.<\/p>\n<p>Depending on the sensor design, an external readout, multimeter, calibrator or data acquisition system can be used to measure the sensor output.<\/p>\n<p>The dual-piston pressure balance provides the mechanical pressure reference throughout the calibration.<\/p>\n<h2>Pressure Switch Testing<\/h2>\n<p>Pressure switches can also be tested using the BH2-1200B.<\/p>\n<p>Pressure is gradually increased until the switch changes state.<\/p>\n<p>The generated reference pressure at this point can be determined using the pressure balance.<\/p>\n<p>Pressure can then be reduced to determine the reset point.<\/p>\n<p>The difference between the two switching points provides information about the switching hysteresis.<\/p>\n<h2>Gravity Correction<\/h2>\n<p>The pressure generated by a deadweight tester depends on the gravitational force acting on its calibrated masses.<\/p>\n<p>For this reason, gravitational acceleration is an important quantity in high-accuracy pressure calibration.<\/p>\n<p>A system can be configured using standard gravitational acceleration:<\/p>\n<p><strong>9.80665 m\/s\u00b2<\/strong><\/p>\n<p>or according to the local gravity at the installation site.<\/p>\n<p>Using the appropriate gravity value ensures that the relationship between calibrated mass, force and generated pressure is correctly represented.<\/p>\n<h2>Environmental Influences<\/h2>\n<p>High-accuracy deadweight tester measurements can be influenced by environmental conditions.<\/p>\n<p>Important quantities include:<\/p>\n<ul data-spread=\"false\">\n<li>Ambient temperature<\/li>\n<li>Atmospheric pressure<\/li>\n<li>Local gravity<\/li>\n<li>Air density<\/li>\n<li>Pressure medium density<\/li>\n<li>Piston-cylinder temperature<\/li>\n<\/ul>\n<p>For demanding metrological applications, these quantities may need to be considered when calculating the generated reference pressure.<\/p>\n<p>This is particularly important when the pressure balance is used as a reference standard in an accredited calibration laboratory.<\/p>\n<h2>Optional Motorization<\/h2>\n<p>The <strong>europascal BH2-1200B<\/strong> can be equipped with optional motorization.<\/p>\n<p>Rotating the piston helps support proper operation of the piston-cylinder assembly by minimizing friction effects.<\/p>\n<p>Motorized operation can improve convenience, particularly when the pressure balance is used frequently.<\/p>\n<p>Optional piston-position visualization can additionally assist the operator in establishing and maintaining the correct floating position.<\/p>\n<h2>Optional Calculator Module<\/h2>\n<p>An optional calculator module can be used to support pressure determination and laboratory workflows.<\/p>\n<p>Depending on the selected system configuration, relevant environmental quantities can be incorporated into the pressure calculation.<\/p>\n<p>This can simplify corrections and reduce manual calculations during pressure calibration.<\/p>\n<p>Digital data transfer can also support calibration documentation and integration into laboratory processes.<\/p>\n<h2>Technical Highlights<\/h2>\n<p>The <strong>europascal BH2-1200B<\/strong> Dual-Piston version combines two piston-cylinder assemblies with a robust hydraulic pressure generation system:<\/p>\n<ul data-spread=\"false\">\n<li>Pressure range: 1 to 1,200 bar<\/li>\n<li>Dual-piston design<\/li>\n<li>Two piston-cylinder systems<\/li>\n<li>Standard accuracy: 0.01 % of reading<\/li>\n<li>Enhanced accuracy: up to 0.006 % on request<\/li>\n<li>Hydraulic pressure generation<\/li>\n<li>H40 oil pressure medium<\/li>\n<li>High long-term stability<\/li>\n<li>High repeatability<\/li>\n<li>Tungsten carbide piston technology<\/li>\n<li>Standard or local gravity configuration<\/li>\n<li>Different pressure units available<\/li>\n<li>Optional motorization<\/li>\n<li>Optional piston-position visualization<\/li>\n<li>Optional calculator module<\/li>\n<li>Suitable for professional pressure laboratories<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>europascal BH2-1200B Dual-Piston<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>europascal Aremeca<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>BH2-1200B DP<\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td>Hydraulic Dual-Piston Deadweight Tester<\/td>\n<\/tr>\n<tr>\n<td>Pressure range<\/td>\n<td>1 to 1,200 bar<\/td>\n<\/tr>\n<tr>\n<td>Number of piston systems<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Standard accuracy<\/td>\n<td>0.01 % of reading<\/td>\n<\/tr>\n<tr>\n<td>Enhanced accuracy<\/td>\n<td>Up to 0.006 % on request<\/td>\n<\/tr>\n<tr>\n<td>Piston material<\/td>\n<td>Tungsten carbide<\/td>\n<\/tr>\n<tr>\n<td>Pressure medium<\/td>\n<td>H40 oil<\/td>\n<\/tr>\n<tr>\n<td>Pressure generation<\/td>\n<td>Hydraulic<\/td>\n<\/tr>\n<tr>\n<td>Standard gravity<\/td>\n<td>9.80665 m\/s\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Local gravity configuration<\/td>\n<td>Available<\/td>\n<\/tr>\n<tr>\n<td>Motorization<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Calculator module<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Application<\/td>\n<td>Precision hydraulic pressure calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Single-Piston or Dual-Piston BH2-1200B?<\/h2>\n<p>The <strong>europascal BH2-1200B<\/strong> is available in different configurations depending on the required pressure range.<\/p>\n<p>The <strong>Single-Piston version<\/strong> covers approximately:<\/p>\n<p><strong>2 to 1,200 bar<\/strong><\/p>\n<p>The <strong>Dual-Piston version<\/strong> extends the lower end of the range to:<\/p>\n<p><strong>1 to 1,200 bar<\/strong><\/p>\n<p>The key advantage of the dual-piston system is therefore its wider measurement range.<\/p>\n<p>Two different piston-cylinder assemblies optimize operation in the lower and higher pressure ranges.<\/p>\n<p>For laboratories that frequently calibrate pressure instruments with significantly different measurement ranges, the dual-piston configuration provides additional flexibility.<\/p>\n<p>The single-piston version can be an appropriate choice when the lower pressure extension is not required.<\/p>\n<h2>Typical Applications<\/h2>\n<p>The <strong>europascal BH2-1200B<\/strong> Dual-Piston Deadweight Tester is suitable for:<\/p>\n<ul data-spread=\"false\">\n<li>Accredited calibration laboratories<\/li>\n<li>DAkkS calibration laboratories<\/li>\n<li>Factory calibration laboratories<\/li>\n<li>Quality assurance<\/li>\n<li>Pressure instrument manufacturing<\/li>\n<li>Mechanical engineering<\/li>\n<li>Process industries<\/li>\n<li>Energy industry<\/li>\n<li>Chemical industry<\/li>\n<li>Pharmaceutical industry<\/li>\n<li>Research and development<\/li>\n<li>Maintenance and service<\/li>\n<\/ul>\n<p>Typical devices under test include pressure gauges, digital pressure gauges, transmitters, transducers, sensors and pressure switches.<\/p>\n<h2>Why Choose the europascal BH2-1200B?<\/h2>\n<p>The <strong>europascal BH2-1200B<\/strong> Dual-Piston Deadweight Tester provides an exceptionally wide hydraulic pressure range from <strong>1 to 1,200 bar<\/strong>.<\/p>\n<p>Its two piston-cylinder systems enable the pressure balance to cover both relatively low hydraulic pressures and high-pressure applications within one reference system.<\/p>\n<p>The standard accuracy of <strong>0.01 % of reading<\/strong> makes the system suitable for demanding professional pressure calibration. An enhanced accuracy of up to <strong>0.006 % of reading<\/strong> is available for applications with even higher metrological requirements.<\/p>\n<p>Combined with robust hydraulic pressure generation, high-quality piston-cylinder assemblies and optional laboratory automation features, the BH2-1200B provides a durable pressure reference for professional metrology.<\/p>\n<p>At <strong>europascal<\/strong>, we can assist you in selecting the appropriate piston-cylinder configuration, mass sets, pressure units, adapters and accessories for your individual pressure calibration application.<\/p>\n<p>For professional calibration and metrological traceability of pressure balances, pressure gauges, transmitters and pressure sensors, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p>Additional pressure measurement and calibration solutions are available through the <a href=\"https:\/\/europascal.de\/en\/\">europascal English homepage<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/aremeca-europascal\/\">Discover more europascal Aremeca products here.<\/a><\/p>\n<p>Manufacturer information about the <strong>europascal BH2-1200B Dual-Piston Deadweight Tester<\/strong> is available on the <a href=\"https:\/\/en.aremeca-instrumentation.com\/produit\/bh2-1200b-dp\" target=\"_blank\" rel=\"noopener\">official Aremeca Instrumentation BH2-1200B DP product page<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/europascal-bh2-1200b-dp-deadweight-tester-hydraulic-2.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p data-pm-slice=\"1 1 []\">The <strong>europascal BH2-1200B<\/strong> is a precise hydraulic dual-piston deadweight tester for pressure calibration from <strong>1 to 1,200 bar<\/strong>. Two piston-cylinder systems provide excellent flexibility across the wide pressure range, while an accuracy of <strong>0.01 % of reading<\/strong>, optionally up to <strong>0.006 %<\/strong>, makes it ideal for professional pressure calibration laboratories.<\/p>\n","protected":false},"featured_media":3095,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[94],"product_cat":[667,45],"product_tag":[4524,4525,4526,4527,4528,4508,4529,4510,4530,4225,4202,4203,4511,4531,4514,4313,4532,4314,4517,3922,4519,4533,4534,4535,4536,4537],"class_list":["post-6425","product","type-product","status-publish","has-post-thumbnail","product_brand-aremeca-europascal","product_cat-deadweight-tester","product_cat-pressure","product_tag-006-prozent-genauigkeit","product_tag-01-prozent-genauigkeit","product_tag-aremeca-bh2-1200b-dp","product_tag-aremeca-instrumentation","product_tag-automatische-druckberechnung","product_tag-bh2-1200b-dp","product_tag-bh2-1200b-einzelkolben","product_tag-doppelkolben-druckwaage","product_tag-doppelkolben-hochdruckwaage","product_tag-druckkalibrierung","product_tag-drucksensor-kalibrieren","product_tag-drucktransmitter-kalibrieren","product_tag-druckwaage-1200-bar","product_tag-empfohlener-permalink-europascal-bh2-1200b-dp-produkt-schlagwoerter-europascal-bh2-1200b-dp","product_tag-europascal-aremeca","product_tag-hochdruckkalibrierung","product_tag-hochdruckkolben","product_tag-hochdruckmanometer-kalibrieren","product_tag-hydraulische-druckwaage","product_tag-kalibrierlabor","product_tag-kolbenmanometer","product_tag-kolbenpositionsanzeige","product_tag-niederdruckkolben","product_tag-referenznormal-druck","product_tag-zwei-kolben","product_tag-zwei-kolben-zylinder-systeme","pa_druckbereich-1-bis-60-bar-and-20-bis-1200-bar","pa_genauigkeit-0-01-vom-messwert-bis-0-008-auf-anfrage","pa_koben-zylindereinheit-doppelkolben","pa_medium-oel","pa_motorisierung-manuelle-drehung-der-gewichte","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3095"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6425"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6425"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6425"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}