{"id":6477,"date":"2026-07-17T16:22:56","date_gmt":"2026-07-17T16:22:56","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-8808a\/"},"modified":"2026-09-28T11:31:41","modified_gmt":"2026-09-28T11:31:41","slug":"fluke-calibration-8808a","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-8808a\/","title":{"rendered":"Fluke 8808A Precise Digital Multimeter"},"content":{"rendered":"<p data-pm-slice=\"1 1 []\"><strong>Fluke 8808A<\/strong> is a precise 5.5-digit bench digital multimeter designed for professional calibration laboratories, manufacturing, research and development, service departments and automated test systems. It combines high measurement accuracy with straightforward operation, a dual display, dedicated leakage current measurement and the innovative 2\u00d74-wire resistance measurement technique.<\/p>\n<p>With a basic DC voltage accuracy of <strong>0.015 %<\/strong>, DC voltage measurement up to <strong>1000 V<\/strong>, AC voltage up to <strong>750 V<\/strong>, current measurement up to <strong>10 A<\/strong>, resistance measurement up to <strong>100 M\u03a9<\/strong> and frequency measurement up to <strong>1 MHz<\/strong>, the Fluke 8808A covers the essential electrical quantities required for a broad range of laboratory and production applications.<\/p>\n<p>The 5.5-digit resolution provides detailed measurement results while maintaining fast and intuitive operation. Six dedicated setup keys allow frequently used instrument configurations to be stored and recalled at the touch of a button. This is particularly useful for repetitive calibration, inspection and production testing.<\/p>\n<p>A dedicated <strong>DC leakage current measurement function<\/strong> provides improved performance for sensitive low-current measurements. For resistance measurements, Fluke&#8217;s 2\u00d74-wire technique allows precision four-wire measurements using only two specially designed test leads.<\/p>\n<p>The integrated <strong>Hi\/Lo Limit Compare<\/strong> function provides clear Pass\/Fail indication, making the 8808A particularly suitable for repetitive production testing and incoming inspection.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional electrical calibration solutions ranging from precision digital multimeters and reference instruments to multiproduct calibrators and complete automated calibration systems.<\/p>\n<p>For professional calibration and metrological traceability of digital multimeters and other electrical measuring equipment, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul data-spread=\"false\">\n<li>Professional 5.5-digit bench digital multimeter<\/li>\n<li>Basic DC voltage accuracy of 0.015 %<\/li>\n<li>DC voltage measurement up to 1000 V<\/li>\n<li>AC voltage measurement up to 750 V<\/li>\n<li>DC current measurement up to 10 A<\/li>\n<li>AC current measurement up to 10 A<\/li>\n<li>Resistance measurement up to 100 M\u03a9<\/li>\n<li>Frequency measurement up to 1 MHz<\/li>\n<li>Maximum DC voltage resolution of 1 \u00b5V<\/li>\n<li>Maximum DC current resolution of 1 nA<\/li>\n<li>Maximum resistance resolution of 1 m\u03a9<\/li>\n<li>Dual measurement display<\/li>\n<li>Dedicated DC leakage current measurement<\/li>\n<li>2\u00d74-wire resistance measurement<\/li>\n<li>Four-wire resistance measurement<\/li>\n<li>Six programmable setup buttons<\/li>\n<li>Hi\/Lo Limit Compare function<\/li>\n<li>Clear Pass\/Fail indication<\/li>\n<li>dB and dBm mathematical functions<\/li>\n<li>Min\/Max functions<\/li>\n<li>Continuity measurement<\/li>\n<li>Diode test<\/li>\n<li>RS-232 interface<\/li>\n<li>USB connectivity using an adapter<\/li>\n<li>Fluke 45 remote command emulation<\/li>\n<li>Suitable for automated test systems<\/li>\n<li>Compact benchtop design<\/li>\n<\/ul>\n<h2>5.5-Digit Resolution<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> provides:<\/p>\n<p><strong>5.5-digit resolution<\/strong><\/p>\n<p>for precision bench measurements.<\/p>\n<p>This resolution makes the instrument suitable for applications where a conventional handheld multimeter does not provide sufficient resolution or measurement performance.<\/p>\n<p>Typical applications include:<\/p>\n<ul data-spread=\"false\">\n<li>Calibration laboratories<\/li>\n<li>Electrical laboratories<\/li>\n<li>Manufacturing<\/li>\n<li>Production testing<\/li>\n<li>Research and development<\/li>\n<li>Quality assurance<\/li>\n<li>Incoming inspection<\/li>\n<li>Service departments<\/li>\n<li>Automated test systems<\/li>\n<\/ul>\n<p>The 8808A combines this resolution with an easy-to-use front-panel interface.<\/p>\n<h2>DC Voltage Measurement up to 1000 V<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> provides DC voltage measurement ranges from:<\/p>\n<p><strong>200 mV to 1000 V<\/strong><\/p>\n<p>Maximum resolution is:<\/p>\n<p><strong>1 \u00b5V<\/strong><\/p>\n<p>Fluke specifies a basic DC voltage accuracy of:<\/p>\n<p><strong>\u00b1(0.015 % of reading + 0.003 % of range)<\/strong><\/p>\n<p>for the applicable specification.<\/p>\n<p>This makes DC voltage measurement one of the core strengths of the 8808A.<\/p>\n<p>The wide range allows the instrument to measure signals ranging from low-level electronic circuits to high-voltage electrical equipment.<\/p>\n<h2>AC Voltage Measurement up to 750 V<\/h2>\n<p>AC voltage measurement ranges extend from:<\/p>\n<p><strong>200 mV to 750 V<\/strong><\/p>\n<p>with maximum resolution down to:<\/p>\n<p><strong>1 \u00b5V<\/strong><\/p>\n<p>The AC voltage frequency range extends up to:<\/p>\n<p><strong>100 kHz<\/strong><\/p>\n<p>depending on the selected range and signal level.<\/p>\n<p>Fluke specifies basic AC voltage accuracy of:<\/p>\n<p><strong>\u00b1(0.2 % of reading + 0.05 % of range)<\/strong><\/p>\n<p>for the applicable specification.<\/p>\n<p>This provides useful AC measurement performance for laboratory, service and production applications.<\/p>\n<h2>DC Current Measurement up to 10 A<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> measures DC current over ranges extending from:<\/p>\n<p><strong>200 \u00b5A to 10 A<\/strong><\/p>\n<p>Maximum resolution reaches:<\/p>\n<p><strong>1 nA<\/strong><\/p>\n<p>Fluke specifies basic DC current accuracy of:<\/p>\n<p><strong>\u00b1(0.02 % of reading + 0.005 % of range)<\/strong><\/p>\n<p>for the applicable range and conditions.<\/p>\n<p>This broad current capability allows both low-current electronic circuits and higher-current loads to be measured using one benchtop instrument.<\/p>\n<h2>Dedicated Leakage Current Measurement<\/h2>\n<p>An important feature of the <strong>Fluke 8808A<\/strong> is its dedicated DC leakage current measurement capability.<\/p>\n<p>The instrument includes low-impedance, low-current ranges specifically intended for sensitive leakage current measurements.<\/p>\n<p>This helps reduce the burden voltage effects that can influence conventional current measurements in sensitive electronic circuits.<\/p>\n<p>The function is particularly useful for applications such as:<\/p>\n<ul data-spread=\"false\">\n<li>Battery-powered devices<\/li>\n<li>Standby circuits<\/li>\n<li>Electronic assemblies<\/li>\n<li>Power supplies<\/li>\n<li>Low-current circuitry<\/li>\n<li>Production testing<\/li>\n<\/ul>\n<h2>AC Current up to 10 A<\/h2>\n<p>The 8808A also measures AC current up to:<\/p>\n<p><strong>10 A<\/strong><\/p>\n<p>The specified AC current measurement frequency extends up to:<\/p>\n<p><strong>2 kHz<\/strong><\/p>\n<p>depending on the selected range.<\/p>\n<p>This enables the instrument to cover many common AC current measurements in laboratory and industrial applications.<\/p>\n<h2>Resistance Measurement up to 100 M\u03a9<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> provides resistance measurement ranges from:<\/p>\n<p><strong>200 \u03a9 to 100 M\u03a9<\/strong><\/p>\n<p>Maximum resolution reaches:<\/p>\n<p><strong>1 m\u03a9<\/strong><\/p>\n<p>Fluke specifies basic resistance accuracy of:<\/p>\n<p><strong>\u00b1(0.02 % of reading + 0.003 % of range)<\/strong><\/p>\n<p>for the applicable conditions.<\/p>\n<p>The broad resistance range enables measurement of low-value resistors as well as high-resistance components.<\/p>\n<h2>2\u00d74-Wire Resistance Measurement<\/h2>\n<p>One of the most distinctive features of the <strong>Fluke 8808A<\/strong> is its patented 2\u00d74-wire resistance measurement technique.<\/p>\n<p>Conventional four-wire resistance measurements normally require four individual test leads.<\/p>\n<p>The 8808A can perform a precision four-wire resistance measurement using only two specially designed 2\u00d74-wire test leads.<\/p>\n<p>Each test lead provides both source and sense connections.<\/p>\n<p>This simplifies four-wire resistance measurements while retaining the main advantage of the Kelvin measurement principle.<\/p>\n<p>Fluke also supports conventional four-lead resistance measurements.<\/p>\n<h2>Why Use Four-Wire Resistance Measurement?<\/h2>\n<p>When measuring low resistance values, the resistance of the test leads and contacts can become significant compared with the device under test.<\/p>\n<p>A conventional two-wire measurement includes these additional resistances in the measured value.<\/p>\n<p>Four-wire measurement separates the current-carrying leads from the voltage-sensing leads.<\/p>\n<p>This significantly reduces the influence of:<\/p>\n<ul data-spread=\"false\">\n<li>Test lead resistance<\/li>\n<li>Contact resistance<\/li>\n<li>Connection resistance<\/li>\n<\/ul>\n<p>The method is therefore particularly valuable for precise low-resistance measurements.<\/p>\n<h2>Frequency Measurement up to 1 MHz<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> provides frequency measurement from:<\/p>\n<p><strong>20 Hz to 1 MHz<\/strong><\/p>\n<p>Maximum frequency resolution is:<\/p>\n<p><strong>0.1 mHz<\/strong><\/p>\n<p>Fluke specifies frequency accuracy of:<\/p>\n<p><strong>0.01 %<\/strong><\/p>\n<p>for the applicable operating conditions.<\/p>\n<p>This integrated frequency function eliminates the need for a separate frequency counter in many routine applications.<\/p>\n<h2>Dual Display<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> features a multi-segment VFD with:<\/p>\n<p><strong>dual readings<\/strong><\/p>\n<p>Two measurement parameters can therefore be displayed simultaneously where supported.<\/p>\n<p>This improves efficiency when evaluating related measurement information.<\/p>\n<p>The bright vacuum fluorescent display provides clear readability in laboratory and production environments.<\/p>\n<h2>Six Setup Keys<\/h2>\n<p>Six dedicated front-panel setup keys are provided:<\/p>\n<p><strong>S1 to S6<\/strong><\/p>\n<p>Frequently used measurement configurations can be stored in these locations.<\/p>\n<p>A stored setup can include parameters such as:<\/p>\n<ul data-spread=\"false\">\n<li>Measurement function<\/li>\n<li>Measurement range<\/li>\n<li>Test limits<\/li>\n<li>Other relevant instrument settings<\/li>\n<\/ul>\n<p>The operator can then recall the complete configuration with a single setup key.<\/p>\n<p>This is particularly valuable for repetitive production or calibration procedures.<\/p>\n<h2>Reduce Operator Errors<\/h2>\n<p>The setup memory helps reduce the number of manual steps required for routine measurements.<\/p>\n<p>Instead of following a long work instruction and manually configuring each parameter, the required measurement configuration can be stored beforehand.<\/p>\n<p>Operators can then select the appropriate setup directly.<\/p>\n<p>This improves:<\/p>\n<ul data-spread=\"false\">\n<li>Repeatability<\/li>\n<li>Efficiency<\/li>\n<li>Ease of operation<\/li>\n<li>Process consistency<\/li>\n<\/ul>\n<p>and reduces the risk of incorrect instrument configuration.<\/p>\n<h2>Hi\/Lo Limit Compare<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> includes a Limit Compare function.<\/p>\n<p>Upper and lower limits can be defined for the measurement.<\/p>\n<p>The instrument then evaluates whether the measured value is inside or outside the specified limits.<\/p>\n<p>Clear:<\/p>\n<p><strong>Pass \/ Fail<\/strong><\/p>\n<p>indicators provide immediate feedback to the operator.<\/p>\n<p>This is especially useful for:<\/p>\n<ul data-spread=\"false\">\n<li>Production testing<\/li>\n<li>Incoming inspection<\/li>\n<li>Quality assurance<\/li>\n<li>Repetitive component testing<\/li>\n<li>Functional testing<\/li>\n<\/ul>\n<h2>Mathematical Functions<\/h2>\n<p>The 8808A includes useful mathematical functions such as:<\/p>\n<ul data-spread=\"false\">\n<li>dB<\/li>\n<li>dBm<\/li>\n<li>Minimum<\/li>\n<li>Maximum<\/li>\n<li>Null<\/li>\n<\/ul>\n<p>These functions provide additional analysis capability directly within the multimeter.<\/p>\n<p>For many routine applications, calculations can therefore be performed without transferring the measured value to separate software.<\/p>\n<h2>Continuity and Diode Testing<\/h2>\n<p>In addition to its precision measurement functions, the <strong>Fluke 8808A<\/strong> includes:<\/p>\n<p><strong>Continuity testing<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>Diode testing<\/strong><\/p>\n<p>These functions make the instrument suitable for general electronics troubleshooting and service applications as well as precision laboratory measurements.<\/p>\n<h2>Automated Measurement Systems<\/h2>\n<p>The 8808A is suitable for integration into automated test and measurement systems.<\/p>\n<p>A standard:<\/p>\n<p><strong>RS-232<\/strong><\/p>\n<p>interface provides remote control capability.<\/p>\n<p>USB connectivity is available using a suitable USB-to-RS-232 adapter.<\/p>\n<p>The instrument supports:<\/p>\n<p><strong>Simplified ASCII<\/strong><\/p>\n<p>commands as well as:<\/p>\n<p><strong>Fluke 45 remote command emulation<\/strong><\/p>\n<p>This helps integrate the 8808A into existing automated systems.<\/p>\n<h2>Fluke 45 Command Emulation<\/h2>\n<p>Fluke 45 remote command emulation can be particularly useful when replacing an older Fluke 45 multimeter in an automated test system.<\/p>\n<p>Existing software may require fewer changes because the 8808A can emulate the remote command structure of the earlier instrument.<\/p>\n<p>This can simplify modernization of existing test stations.<\/p>\n<h2>Calibration Laboratory Applications<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> is well suited for electrical calibration laboratories.<\/p>\n<p>Typical applications include:<\/p>\n<ul data-spread=\"false\">\n<li>Measurement during calibration procedures<\/li>\n<li>Verification of electrical calibrators<\/li>\n<li>Measurement of voltage sources<\/li>\n<li>Resistance measurements<\/li>\n<li>Current measurements<\/li>\n<li>Frequency measurements<\/li>\n<li>Device-under-test monitoring<\/li>\n<li>Automated calibration procedures<\/li>\n<\/ul>\n<p>Its 5.5-digit resolution provides a useful balance between measurement performance, speed and cost.<\/p>\n<h2>Production Testing<\/h2>\n<p>Fluke specifically designed the 8808A for applications including manufacturing and production testing.<\/p>\n<p>Six setup memories and Limit Compare functionality simplify repetitive tests.<\/p>\n<p>An operator can select a stored test configuration, connect the device under test and immediately receive a Pass\/Fail result.<\/p>\n<p>This helps standardize test procedures across multiple operators.<\/p>\n<h2>Research and Development<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> is also suitable for research and development laboratories.<\/p>\n<p>Its broad electrical measurement capability allows engineers and technicians to measure:<\/p>\n<ul data-spread=\"false\">\n<li>DC voltage<\/li>\n<li>AC voltage<\/li>\n<li>DC current<\/li>\n<li>AC current<\/li>\n<li>Resistance<\/li>\n<li>Frequency<\/li>\n<li>Diodes<\/li>\n<li>Continuity<\/li>\n<\/ul>\n<p>The dual display and high resolution are particularly useful during circuit development and troubleshooting.<\/p>\n<h2>Service Applications<\/h2>\n<p>For service departments, the 8808A provides the familiar functions of a digital multimeter with the additional advantages of a precision benchtop instrument.<\/p>\n<p>Its stable bench configuration, clear display and dedicated function keys make it suitable for repeated diagnostic and verification measurements.<\/p>\n<h2>Calibration with Fluke Multiproduct Calibrators<\/h2>\n<p>The 8808A can be calibrated using a suitable high-performance electrical multiproduct calibrator.<\/p>\n<p>Fluke specifically lists the <strong>8808A as an example of a 5.5-digit multimeter workload<\/strong> for its current 5560A and 5550A multiproduct calibrators, with a stated 4:1 TUR for the defined target workload.<\/p>\n<p>This makes the combination suitable for automated electrical calibration laboratories.<\/p>\n<h2>Compact Benchtop Design<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> combines its measurement functions in a compact enclosure.<\/p>\n<p>Dimensions are approximately:<\/p>\n<p><strong>88 \u00d7 217 \u00d7 297 mm<\/strong><\/p>\n<p>and weight is approximately:<\/p>\n<p><strong>2.1 kg<\/strong><\/p>\n<p>The compact format makes it easy to integrate the instrument into:<\/p>\n<ul data-spread=\"false\">\n<li>Laboratory benches<\/li>\n<li>Test racks<\/li>\n<li>Service workstations<\/li>\n<li>Automated systems<\/li>\n<li>Production test stations<\/li>\n<\/ul>\n<h2>Safety Ratings<\/h2>\n<p>The 8808A is designed for:<\/p>\n<p><strong>CAT I 1000 V<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>CAT II 600 V<\/strong><\/p>\n<p>applications according to the specified safety standards.<\/p>\n<p>The appropriate measurement category and maximum input limits must always be observed when connecting the instrument.<\/p>\n<h2>Technical Highlights<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> combines high-resolution electrical measurement with efficient operation:<\/p>\n<ul data-spread=\"false\">\n<li>5.5-digit Digital Multimeter<\/li>\n<li>Dual display<\/li>\n<li>DC voltage to 1000 V<\/li>\n<li>AC voltage to 750 V<\/li>\n<li>DC current to 10 A<\/li>\n<li>AC current to 10 A<\/li>\n<li>Resistance to 100 M\u03a9<\/li>\n<li>Frequency to 1 MHz<\/li>\n<li>1 \u00b5V maximum voltage resolution<\/li>\n<li>1 nA maximum DC current resolution<\/li>\n<li>1 m\u03a9 maximum resistance resolution<\/li>\n<li>0.1 mHz maximum frequency resolution<\/li>\n<li>Basic DC voltage accuracy 0.015 %<\/li>\n<li>Dedicated DC leakage current measurement<\/li>\n<li>2\u00d74-wire resistance measurement<\/li>\n<li>Conventional four-wire resistance measurement<\/li>\n<li>Six setup memories<\/li>\n<li>Hi\/Lo Limit Compare<\/li>\n<li>Pass\/Fail indication<\/li>\n<li>dB and dBm<\/li>\n<li>Min\/Max<\/li>\n<li>Continuity<\/li>\n<li>Diode test<\/li>\n<li>RS-232<\/li>\n<li>USB via adapter<\/li>\n<li>Fluke 45 remote command emulation<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Fluke 8808A<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>8808A<\/td>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Bench Digital Multimeter<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>5.5 digits<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>Dual-reading VFD<\/td>\n<\/tr>\n<tr>\n<td>DC voltage<\/td>\n<td>200 mV to 1000 V<\/td>\n<\/tr>\n<tr>\n<td>DC voltage resolution<\/td>\n<td>Down to 1 \u00b5V<\/td>\n<\/tr>\n<tr>\n<td>Basic DC voltage accuracy<\/td>\n<td>\u00b1(0.015 % reading + 0.003 % range)<\/td>\n<\/tr>\n<tr>\n<td>AC voltage<\/td>\n<td>200 mV to 750 V<\/td>\n<\/tr>\n<tr>\n<td>AC voltage resolution<\/td>\n<td>Down to 1 \u00b5V<\/td>\n<\/tr>\n<tr>\n<td>AC voltage frequency<\/td>\n<td>Up to 100 kHz<\/td>\n<\/tr>\n<tr>\n<td>Resistance<\/td>\n<td>200 \u03a9 to 100 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resistance resolution<\/td>\n<td>Down to 1 m\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resistance technique<\/td>\n<td>2-wire, 4-wire and 2\u00d74-wire<\/td>\n<\/tr>\n<tr>\n<td>DC current<\/td>\n<td>200 \u00b5A to 10 A<\/td>\n<\/tr>\n<tr>\n<td>DC current resolution<\/td>\n<td>Down to 1 nA<\/td>\n<\/tr>\n<tr>\n<td>AC current<\/td>\n<td>20 mA to 10 A<\/td>\n<\/tr>\n<tr>\n<td>AC current frequency<\/td>\n<td>Up to 2 kHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>20 Hz to 1 MHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency resolution<\/td>\n<td>Down to 0.1 mHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency accuracy<\/td>\n<td>0.01 %<\/td>\n<\/tr>\n<tr>\n<td>Leakage current<\/td>\n<td>Dedicated DC leakage measurement<\/td>\n<\/tr>\n<tr>\n<td>Limit testing<\/td>\n<td>Hi\/Lo with Pass\/Fail<\/td>\n<\/tr>\n<tr>\n<td>Setup memories<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>Mathematical functions<\/td>\n<td>dB, dBm, Min, Max, Null<\/td>\n<\/tr>\n<tr>\n<td>Interfaces<\/td>\n<td>RS-232, USB via adapter<\/td>\n<\/tr>\n<tr>\n<td>Remote compatibility<\/td>\n<td>Simplified ASCII, Fluke 45 emulation<\/td>\n<\/tr>\n<tr>\n<td>Safety<\/td>\n<td>CAT I 1000 V, CAT II 600 V<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>88 \u00d7 217 \u00d7 297 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 2.1 kg<\/td>\n<\/tr>\n<tr>\n<td>Warranty<\/td>\n<td>3 years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why Choose the Fluke 8808A?<\/h2>\n<p>The <strong>Fluke 8808A<\/strong> combines 5.5-digit resolution with a broad range of electrical measurement functions and straightforward operation.<\/p>\n<p>Its basic DC voltage accuracy of <strong>0.015 %<\/strong> and measurement capability up to <strong>1000 V DC<\/strong>, <strong>750 V AC<\/strong>, <strong>10 A<\/strong>, <strong>100 M\u03a9<\/strong> and <strong>1 MHz<\/strong> make it suitable for many laboratory, production and service applications.<\/p>\n<p>The dedicated DC leakage current function extends its capability for sensitive low-current measurements.<\/p>\n<p>For resistance measurements, the innovative <strong>2\u00d74-wire technique<\/strong> simplifies precision four-wire measurements by allowing specially designed two-lead connections while retaining the benefits of Kelvin measurement.<\/p>\n<p>Six setup memories make repetitive measurements fast and consistent, while the Hi\/Lo Limit Compare function provides clear Pass\/Fail results for production testing and quality assurance.<\/p>\n<p>The dual display provides clear measurement information, and mathematical functions such as dB, dBm, Min and Max extend the instrument&#8217;s analytical capability.<\/p>\n<p>RS-232 communication, USB connectivity via an adapter and Fluke 45 command emulation simplify integration into automated test and calibration systems.<\/p>\n<p>For calibration laboratories, manufacturing, research and development or professional service applications requiring more performance than a conventional handheld multimeter, the Fluke 8808A provides a practical and proven benchtop measurement solution.<\/p>\n<p>At <strong>europascal<\/strong>, we can support the Fluke 8808A with professional calibration services and help integrate the instrument into your electrical calibration and measurement environment.<\/p>\n<p>For professional calibration and metrological traceability of digital multimeters and other electrical measuring equipment, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Discover more Fluke Calibration products here.<\/a><\/p>\n<p>Manufacturer information about the <strong>Fluke 8808A<\/strong> is available on the <a href=\"https:\/\/www.fluke.com\/en-us\/product\/precision-measurement\/bench-instruments\/fluke-8808a\" target=\"_blank\" rel=\"noopener\">official Fluke 8808A product page<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-8808A-Digital-Multimeter_EN.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Donwload Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p data-pm-slice=\"1 1 []\">The <strong>Fluke 8808A<\/strong> is a precise <strong>5.5-digit bench digital multimeter<\/strong> for calibration laboratories, manufacturing, R&amp;D and service applications. It measures up to <strong>1000 V DC, 750 V AC, 10 A, 100 M\u03a9 and 1 MHz<\/strong> with a basic DC voltage accuracy of <strong>0.015 %<\/strong>. Dual display, dedicated leakage current measurement, 2\u00d74-wire resistance, six setup memories and Pass\/Fail limit testing make the 8808A ideal for both manual and automated measurements.<\/p>\n","protected":false},"featured_media":6480,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[1242,62],"product_tag":[4762,4763,4764,4765,4766,3918,4733,4767,4768,4769,4770,4771,3922,4772,4773,4774,4775,4776,4777,4778,4779],"class_list":["post-6477","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-digital-multimeter","product_cat-electrical","product_tag-100-m-widerstand","product_tag-2-x-4-wire","product_tag-4764","product_tag-5-stelliges-multimeter","product_tag-digitalmultimeter","product_tag-elektrische-kalibrierung","product_tag-elektrische-messtechnik","product_tag-fluke-8808a","product_tag-fluke-calibration-8808a","product_tag-frequenzmessung","product_tag-gleichspannung-messen","product_tag-gleichstrom-messen","product_tag-kalibrierlabor","product_tag-labormultimeter","product_tag-praezisionsmultimeter","product_tag-produktionspruefung","product_tag-rs232-multimeter","product_tag-systemmultimeter","product_tag-tischmultimeter","product_tag-vierleitermessung","product_tag-widerstand-messen","pa_bauart-tischgeraet","pa_hart-kommunikation-nein","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6477","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6480"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6477"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6477"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6477"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6477"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}