{"id":6490,"date":"2026-07-17T16:23:30","date_gmt":"2026-07-17T16:23:30","guid":{"rendered":"https:\/\/europascal.de\/product\/additel-adt-226\/"},"modified":"2026-09-28T12:10:49","modified_gmt":"2026-09-28T12:10:49","slug":"additel-adt-226","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-adt-226\/","title":{"rendered":"Additel ADT 226 Versatile Process Calibrator"},"content":{"rendered":"<p><strong>Additel ADT 226<\/strong> is a versatile multifunction process calibrator designed for professional calibration, maintenance and troubleshooting of process instrumentation. The handheld calibrator combines high-accuracy electrical measurement and sourcing with temperature measurement, loop calibration and pressure measurement using external Additel pressure modules.<\/p>\n<p>With its rugged field-ready design, intuitive color touchscreen and comprehensive measurement functions, the ADT 226 provides technicians and calibration laboratories with a powerful solution for testing transmitters, sensors, switches, indicators and other process instrumentation.<\/p>\n<p>The <strong>Additel ADT 226<\/strong> measures and sources a broad range of electrical signals including voltage, current, resistance, frequency and pulse signals. It also supports thermocouples and RTDs, allowing the instrument to simulate and measure common industrial temperature sensors.<\/p>\n<p>For pressure calibration, compatible Additel external pressure modules can be connected to the calibrator. This allows the ADT 226 to become a complete portable pressure calibration solution when combined with a suitable hand pump or pressure source.<\/p>\n<p>An integrated <strong>24 V loop power supply<\/strong> simplifies the calibration of 4\u201320 mA transmitters. HART communication capability further extends the ADT 226 for modern process instrumentation.<\/p>\n<p>The calibrator is designed for demanding field conditions. A rugged enclosure, large touchscreen and rechargeable battery make it suitable for daily use in industrial plants, maintenance workshops and calibration laboratories.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional calibration equipment for pressure, temperature and electrical measurement applications. The Additel ADT 226 can be combined with suitable pressure modules, calibration pumps and accessories to create a complete portable calibration solution.<\/p>\n<p>For professional calibration and metrological traceability of process calibrators, pressure modules, temperature measuring equipment and electrical measuring instruments, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Multifunction process calibrator<\/li>\n<li>High-accuracy electrical measurement and sourcing<\/li>\n<li>DC voltage measurement and source<\/li>\n<li>DC current measurement and source<\/li>\n<li>Resistance measurement and simulation<\/li>\n<li>Frequency measurement and source<\/li>\n<li>Pulse measurement and source<\/li>\n<li>Thermocouple measurement and simulation<\/li>\n<li>RTD measurement and simulation<\/li>\n<li>24 V loop power supply<\/li>\n<li>4\u201320 mA transmitter calibration<\/li>\n<li>HART communication capability<\/li>\n<li>Pressure measurement with external Additel pressure modules<\/li>\n<li>Pressure switch testing<\/li>\n<li>Temperature transmitter calibration<\/li>\n<li>Large color touchscreen<\/li>\n<li>Intuitive graphical user interface<\/li>\n<li>Rechargeable battery<\/li>\n<li>Data logging capability<\/li>\n<li>Rugged portable design<\/li>\n<li>Suitable for laboratory and field calibration<\/li>\n<li>Ideal for process instrumentation maintenance<\/li>\n<\/ul>\n<h2>Multifunction Process Calibration<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> combines multiple calibration functions within one portable instrument.<\/p>\n<p>Instead of carrying separate devices for current, voltage, resistance, temperature and pressure measurement, technicians can perform many common process calibration tasks using a single platform.<\/p>\n<p>Typical devices under test include:<\/p>\n<ul>\n<li>Pressure transmitters<\/li>\n<li>Temperature transmitters<\/li>\n<li>Pressure gauges<\/li>\n<li>Pressure switches<\/li>\n<li>RTD indicators<\/li>\n<li>Thermocouple indicators<\/li>\n<li>Process controllers<\/li>\n<li>Recorders<\/li>\n<li>Data loggers<\/li>\n<li>Current loops<\/li>\n<li>Electrical indicators<\/li>\n<\/ul>\n<p>This broad functionality makes the ADT 226 suitable for both field service and calibration laboratory applications.<\/p>\n<h2>Electrical Measurement<\/h2>\n<p>The Additel ADT 226 provides precision electrical measurement for common process signals.<\/p>\n<p>Depending on the selected function, the calibrator can measure:<\/p>\n<ul>\n<li>DC voltage<\/li>\n<li>DC current<\/li>\n<li>Resistance<\/li>\n<li>Frequency<\/li>\n<li>Pulse signals<\/li>\n<li>Thermocouples<\/li>\n<li>RTDs<\/li>\n<\/ul>\n<p>This allows technicians to troubleshoot and calibrate a wide variety of industrial process instruments.<\/p>\n<h2>Electrical Signal Generation<\/h2>\n<p>In addition to measurement, the <strong>Additel ADT 226<\/strong> can generate electrical signals.<\/p>\n<p>Source functions include:<\/p>\n<ul>\n<li>DC voltage<\/li>\n<li>DC current<\/li>\n<li>Resistance<\/li>\n<li>Frequency<\/li>\n<li>Pulse<\/li>\n<li>Thermocouple simulation<\/li>\n<li>RTD simulation<\/li>\n<\/ul>\n<p>Signal generation is particularly important when calibrating indicators, transmitters, controllers and data acquisition systems.<\/p>\n<p>A defined reference signal is generated by the ADT 226 and compared with the indication or output of the device under test.<\/p>\n<h2>4\u201320 mA Process Calibration<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> is particularly useful for calibration of industrial:<\/p>\n<p><strong>4\u201320 mA current loops<\/strong><\/p>\n<p>These current loops are widely used for transmitting measurement values in industrial process systems.<\/p>\n<p>The calibrator can measure and source current signals, allowing both transmitters and receiving instruments to be tested.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Pressure transmitters<\/li>\n<li>Temperature transmitters<\/li>\n<li>Flow transmitters<\/li>\n<li>Level transmitters<\/li>\n<li>Process indicators<\/li>\n<li>PLC input modules<\/li>\n<li>Control systems<\/li>\n<\/ul>\n<h2>24 V Loop Power<\/h2>\n<p>The integrated loop power supply can provide the power required by a two-wire process transmitter.<\/p>\n<p>This eliminates the need for a separate external power supply in many calibration setups.<\/p>\n<p>The technician can power the transmitter and measure its output using the same handheld calibrator.<\/p>\n<p>This significantly simplifies field calibration.<\/p>\n<h2>HART Communication<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> provides HART communication capability for compatible process transmitters.<\/p>\n<p>HART is widely used in modern industrial instrumentation because it combines conventional 4\u201320 mA analog signals with digital communication.<\/p>\n<p>HART functionality allows technicians to work with transmitter information and parameters while performing calibration and maintenance tasks.<\/p>\n<p>This makes the ADT 226 suitable for modern smart transmitter applications.<\/p>\n<h2>Temperature Calibration<\/h2>\n<p>Temperature calibration is another important application of the <strong>Additel ADT 226<\/strong>.<\/p>\n<p>The calibrator supports both:<\/p>\n<p><strong>RTDs<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>thermocouples<\/strong><\/p>\n<p>These sensor types cover a large proportion of industrial temperature measurement applications.<\/p>\n<p>The ADT 226 can measure physical temperature sensors and simulate sensor signals for testing temperature indicators and transmitters.<\/p>\n<h2>RTD Measurement<\/h2>\n<p>Resistance temperature detectors can be connected directly to the ADT 226.<\/p>\n<p>The calibrator measures the resistance of the sensor and converts it into the corresponding temperature according to the selected RTD characteristic.<\/p>\n<p>This allows direct measurement of common industrial RTDs.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Pt100 sensors<\/li>\n<li>Temperature probes<\/li>\n<li>Temperature transmitters<\/li>\n<li>Process temperature measurement systems<\/li>\n<\/ul>\n<h2>RTD Simulation<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> can also simulate RTDs.<\/p>\n<p>Instead of using an actual temperature source, the calibrator generates the resistance corresponding to a selected temperature.<\/p>\n<p>An RTD transmitter or temperature indicator interprets this resistance as if a real RTD sensor were connected.<\/p>\n<p>This provides a fast method for checking the electronic portion of a temperature measurement chain.<\/p>\n<h2>Thermocouple Measurement<\/h2>\n<p>Thermocouples generate a small voltage depending on the temperature difference between the measuring and reference junctions.<\/p>\n<p>The ADT 226 can measure thermocouple signals and convert the voltage into the corresponding temperature.<\/p>\n<p>Support for common industrial thermocouple characteristics allows the calibrator to cover a wide range of temperature applications.<\/p>\n<h2>Thermocouple Simulation<\/h2>\n<p>For transmitter and indicator calibration, the <strong>Additel ADT 226<\/strong> can simulate thermocouple signals.<\/p>\n<p>The required temperature is entered directly into the calibrator.<\/p>\n<p>The ADT 226 then generates the corresponding thermoelectric voltage.<\/p>\n<p>This allows devices such as:<\/p>\n<ul>\n<li>Temperature transmitters<\/li>\n<li>Temperature indicators<\/li>\n<li>Process controllers<\/li>\n<li>Data loggers<\/li>\n<li>Recorders<\/li>\n<\/ul>\n<p>to be calibrated without requiring a physical thermocouple and temperature source.<\/p>\n<h2>Pressure Measurement<\/h2>\n<p>Pressure measurement can be added to the <strong>Additel ADT 226<\/strong> using compatible external Additel pressure modules.<\/p>\n<p>The modular approach allows the user to select pressure ranges according to the individual calibration workload.<\/p>\n<p>This makes it possible to use one ADT 226 with different pressure modules rather than requiring a separate pressure calibrator for every range.<\/p>\n<h2>Pressure Calibration System<\/h2>\n<p>When the ADT 226 is combined with an external pressure module and a suitable Additel pressure pump, it becomes a complete portable pressure calibration system.<\/p>\n<p>The pump generates the test pressure.<\/p>\n<p>The external pressure module provides the reference pressure measurement.<\/p>\n<p>The ADT 226 measures the electrical output of the device under test.<\/p>\n<p>This configuration is particularly useful for calibration of pressure transmitters.<\/p>\n<h2>Pressure Transmitter Calibration<\/h2>\n<p>A typical pressure transmitter converts an applied pressure into a:<\/p>\n<p><strong>4\u201320 mA<\/strong><\/p>\n<p>electrical output signal.<\/p>\n<p>During calibration, a suitable pressure pump generates the test pressure.<\/p>\n<p>The Additel pressure module connected to the ADT 226 measures the applied reference pressure.<\/p>\n<p>At the same time, the ADT 226 measures the transmitter&#8217;s current output.<\/p>\n<p>This allows the pressure input and electrical output to be evaluated using one portable calibration system.<\/p>\n<h2>Pressure Switch Testing<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> can also be used for pressure switch testing.<\/p>\n<p>During the test, pressure is gradually increased or decreased while the calibrator monitors the switch status.<\/p>\n<p>This allows important switch characteristics to be determined, including:<\/p>\n<ul>\n<li>Switching point<\/li>\n<li>Reset point<\/li>\n<li>Deadband<\/li>\n<\/ul>\n<p>Pressure switch testing is commonly required during maintenance and calibration of industrial safety and control systems.<\/p>\n<h2>Frequency and Pulse Functions<\/h2>\n<p>The ADT 226 supports frequency and pulse signals in addition to conventional voltage and current functions.<\/p>\n<p>These functions expand the calibrator&#8217;s application range to instruments that use frequency-based process signals.<\/p>\n<p>Typical applications can include:<\/p>\n<ul>\n<li>Frequency indicators<\/li>\n<li>Pulse counters<\/li>\n<li>Flow instrumentation<\/li>\n<li>Speed measurement systems<\/li>\n<li>Process controllers<\/li>\n<\/ul>\n<h2>Data Logging<\/h2>\n<p>The <strong>Additel ADT226<\/strong> provides data logging functionality for recording measurement values over time.<\/p>\n<p>Data logging is useful when measurements need to be monitored over a longer period or when a complete measurement sequence must be documented.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Stability testing<\/li>\n<li>Process monitoring<\/li>\n<li>Troubleshooting<\/li>\n<li>Calibration documentation<\/li>\n<li>Long-term measurements<\/li>\n<\/ul>\n<p>Recorded data can subsequently be evaluated and documented.<\/p>\n<h2>Large Color Touchscreen<\/h2>\n<p>A modern graphical user interface is one of the major advantages of the ADT 226.<\/p>\n<p>The large color touchscreen provides clear access to measurement and source functions.<\/p>\n<p>Operators can configure calibration tasks directly on the instrument without navigating through complex combinations of physical keys.<\/p>\n<p>The graphical interface also makes simultaneous measurement information easier to interpret.<\/p>\n<h2>Portable Field Calibration<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> is designed for portable operation.<\/p>\n<p>Its rechargeable battery allows the instrument to be used independently of an external power supply.<\/p>\n<p>This is particularly useful in:<\/p>\n<ul>\n<li>Production plants<\/li>\n<li>Process facilities<\/li>\n<li>Maintenance departments<\/li>\n<li>Field service<\/li>\n<li>Remote measurement locations<\/li>\n<\/ul>\n<p>The rugged enclosure is designed to withstand the conditions typically encountered during industrial field calibration.<\/p>\n<h2>Laboratory Applications<\/h2>\n<p>Although optimized for portable use, the ADT 226 is equally suitable for calibration laboratories.<\/p>\n<p>Its broad range of electrical, temperature and pressure functions makes it useful as a flexible working standard for many routine calibration tasks.<\/p>\n<p>A laboratory can configure the ADT 226 with different external pressure modules according to its pressure calibration range.<\/p>\n<h2>Process Industry Applications<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> is particularly suited to industries with large quantities of process instrumentation.<\/p>\n<p>Typical industries include:<\/p>\n<ul>\n<li>Chemical industry<\/li>\n<li>Pharmaceutical industry<\/li>\n<li>Oil and gas<\/li>\n<li>Energy generation<\/li>\n<li>Water and wastewater<\/li>\n<li>Food and beverage<\/li>\n<li>Manufacturing<\/li>\n<li>Automotive<\/li>\n<li>Aerospace<\/li>\n<li>Process engineering<\/li>\n<\/ul>\n<p>Technicians can use the same instrument for electrical, temperature and pressure-related calibration tasks.<\/p>\n<h2>Technical Highlights<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> combines multiple process calibration functions in one portable platform:<\/p>\n<ul>\n<li>Multifunction Process Calibrator<\/li>\n<li>DC voltage measurement and source<\/li>\n<li>DC current measurement and source<\/li>\n<li>Resistance measurement and simulation<\/li>\n<li>Frequency measurement and source<\/li>\n<li>Pulse measurement and source<\/li>\n<li>Thermocouple measurement<\/li>\n<li>Thermocouple simulation<\/li>\n<li>RTD measurement<\/li>\n<li>RTD simulation<\/li>\n<li>24 V loop power<\/li>\n<li>4\u201320 mA calibration<\/li>\n<li>HART communication<\/li>\n<li>External pressure module support<\/li>\n<li>Pressure transmitter calibration<\/li>\n<li>Pressure switch testing<\/li>\n<li>Data logging<\/li>\n<li>Color touchscreen<\/li>\n<li>Rechargeable battery<\/li>\n<li>Portable design<\/li>\n<li>Laboratory and field use<\/li>\n<\/ul>\n<h2>Typical Applications<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> can be used for a wide range of professional calibration and maintenance tasks:<\/p>\n<p><strong>Pressure transmitter calibration<\/strong><\/p>\n<p>Measure reference pressure using an external Additel pressure module while simultaneously measuring the transmitter&#8217;s electrical output.<\/p>\n<p><strong>Temperature transmitter calibration<\/strong><\/p>\n<p>Simulate an RTD or thermocouple signal and measure the resulting 4\u201320 mA transmitter output.<\/p>\n<p><strong>RTD indicator calibration<\/strong><\/p>\n<p>Generate a defined resistance corresponding to a specified RTD temperature.<\/p>\n<p><strong>Thermocouple indicator calibration<\/strong><\/p>\n<p>Generate the thermoelectric voltage corresponding to the selected thermocouple type and temperature.<\/p>\n<p><strong>Current loop calibration<\/strong><\/p>\n<p>Source or measure standard 4\u201320 mA process signals.<\/p>\n<p><strong>Pressure switch testing<\/strong><\/p>\n<p>Determine switching point, reset point and deadband.<\/p>\n<p><strong>Process troubleshooting<\/strong><\/p>\n<p>Measure voltage, current, resistance, frequency and temperature signals directly in industrial systems.<\/p>\n<h2>Why Choose the Additel ADT 226?<\/h2>\n<p>The <strong>Additel ADT 226<\/strong> combines the functions required for many everyday process calibration tasks within one compact portable instrument.<\/p>\n<p>Electrical measurement and sourcing capabilities allow voltage, current, resistance, frequency and pulse signals to be tested.<\/p>\n<p>RTD and thermocouple measurement and simulation extend the instrument into professional temperature calibration.<\/p>\n<p>An integrated 24 V loop power supply simplifies calibration of two-wire transmitters, while HART communication provides additional support for modern smart process instrumentation.<\/p>\n<p>External Additel pressure modules extend the system into pressure calibration applications.<\/p>\n<p>Combined with a suitable pressure pump, the ADT 226 can simultaneously measure the reference pressure and electrical output of a pressure transmitter.<\/p>\n<p>This multifunction approach reduces the number of individual instruments technicians need to carry into the field.<\/p>\n<p>The color touchscreen provides intuitive operation, while rechargeable battery power enables independent field use.<\/p>\n<p>For calibration laboratories, maintenance departments and process industry technicians requiring a single instrument for electrical, temperature and pressure calibration tasks, the Additel ADT 226 provides a flexible and efficient solution.<\/p>\n<p>At <strong>europascal<\/strong>, we can assist with configuring the ADT 226 with suitable Additel pressure modules, pressure pumps and accessories for your individual calibration requirements.<\/p>\n<p>For professional calibration and metrological traceability of process calibrators, pressure modules, electrical measuring equipment and temperature measuring instruments, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p>Manufacturer information is available from <a href=\"https:\/\/www.additel.com\/\" target=\"_blank\" rel=\"noopener\">Additel<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Additel-ADT-226-226Ex-Multifunction-Process-Calibrators-20260130.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p data-pm-slice=\"1 1 []\">The <strong>Additel ADT 226<\/strong> is a versatile multifunction process calibrator for professional field and laboratory applications. It measures and sources <strong>voltage, current, resistance, frequency, pulses, RTDs and thermocouples<\/strong> and provides integrated <strong>24 V loop power<\/strong> and HART communication. Compatible external Additel pressure modules extend the ADT 226 into pressure transmitter and pressure switch calibration.<\/p>\n","protected":false},"featured_media":6491,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[90],"product_cat":[64,62],"product_tag":[4744,4801,4802,4803,4804,4805,4806,4201,4807,4203,3919,3920,4808,4809,3922,4810,4811,4812,4593,4752,3999,4002,3929,4813,4814],"class_list":["post-6490","product","type-product","status-publish","has-post-thumbnail","product_brand-additel","product_cat-process-multifunction-calibrators","product_cat-electrical","product_tag-4-bis-20-ma-kalibrator","product_tag-additel-226","product_tag-additel-adt-226","product_tag-adt-226","product_tag-adt-226ex","product_tag-adt-227","product_tag-adt-227ex","product_tag-druckkalibrator","product_tag-druckmodul","product_tag-drucktransmitter-kalibrieren","product_tag-elektrischer-kalibrator","product_tag-europascal","product_tag-instandhaltung","product_tag-ip67","product_tag-kalibrierlabor","product_tag-loop-kalibrator","product_tag-multifunktions-prozesskalibrator","product_tag-prozess-kalibrator","product_tag-prozesskalibrator","product_tag-rtd-kalibrator","product_tag-temperaturkalibrator","product_tag-temperaturtransmitter-kalibrieren","product_tag-thermoelement-kalibrator","product_tag-true-rms","product_tag-wartung","pa_bauart-handgeraet","pa_hart-kommunikation-nein","pa_kanal-2-kanal","pa_schnittstelle-usb-typ-c-wlan-und-bluetooth","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6490","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6491"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6490"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6490"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6490"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6490"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}