{"id":6515,"date":"2026-09-10T12:03:34","date_gmt":"2026-09-10T12:03:34","guid":{"rendered":"https:\/\/europascal.de\/product\/transmille-3041a\/"},"modified":"2026-09-29T07:59:17","modified_gmt":"2026-09-29T07:59:17","slug":"transmille-3041a","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/transmille-3041a\/","title":{"rendered":"Transmille 3041A Precise Multiproduct Calibrator"},"content":{"rendered":"<p><strong>Transmille 3041A<\/strong> is a precise multiproduct calibrator designed for professional electrical calibration laboratories requiring a broad workload from a single calibration platform. With DC and AC voltage up to 1000 V, DC and AC current up to 30 A, resistance up to 1 G\u03a9, capacitance, frequency and thermocouple simulation, the 3041A combines multiple electrical calibration functions in one versatile instrument.<\/p>\n<p>With best one-year DC voltage accuracy down to <strong>\u00b125 ppm<\/strong>, the Transmille 3041A provides the performance required for calibration of modern digital multimeters while also delivering sufficient output capability for older analog instruments.<\/p>\n<p>The 3041A is part of Transmille&#8217;s 3000A Series of precision multiproduct calibrators. The series has been designed to provide broad workload coverage and can be expanded through a comprehensive selection of internal options and external adapters.<\/p>\n<p>Depending on configuration, the <strong>Transmille 3041A<\/strong> can be used to calibrate multimeters, clamp meters, resistance meters, capacitance meters, frequency counters, thermocouple indicators, power meters, oscilloscopes and other electrical test equipment.<\/p>\n<p>For automated calibration, the 3041A is supported by Transmille ProCal Version 6, including automatic uncertainty support.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional solutions for electrical calibration, automated calibration and precision measurement. The Transmille 3041A can be configured with suitable options, adapters and software according to your individual calibration workload.<\/p>\n<p>For professional calibration and metrological traceability of electrical calibrators and measuring equipment, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> combines precision, broad workload coverage and expandability in one professional electrical calibration platform.<\/p>\n<p>Key benefits include:<\/p>\n<ul>\n<li>Precision multiproduct calibrator<\/li>\n<li>Best DC voltage accuracy of \u00b125 ppm<\/li>\n<li>DC voltage up to \u00b11000 V<\/li>\n<li>DC current up to \u00b130 A<\/li>\n<li>Best DC current accuracy of \u00b150 ppm<\/li>\n<li>AC voltage up to 1000 V<\/li>\n<li>AC voltage frequency up to 500 kHz<\/li>\n<li>AC current up to 30 A<\/li>\n<li>AC current frequency up to 10 kHz<\/li>\n<li>Passive resistance up to 1 G\u03a9<\/li>\n<li>Best resistance accuracy down to 40 ppm<\/li>\n<li>Passive capacitance from 1 nF to 10 \u00b5F<\/li>\n<li>Frequency generation from 1 Hz to 10 MHz<\/li>\n<li>Optional 1 ppm high-stability frequency output<\/li>\n<li>Thermocouple simulation<\/li>\n<li>Expandable with internal and external options<\/li>\n<li>Optional oscilloscope calibration<\/li>\n<li>Optional power calibration<\/li>\n<li>Optional inductance outputs<\/li>\n<li>Optional precision PRT output<\/li>\n<li>Optional variable resistance and capacitance<\/li>\n<li>External picoamp and high-resistance accessories<\/li>\n<li>Automated calibration with ProCal 6<\/li>\n<li>Automatic uncertainty support with ProCal 6<\/li>\n<li>Suitable for modern digital and older analog instruments<\/li>\n<\/ul>\n<h2>Wide Workload Coverage<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> has been developed to reduce the number of individual standards required in an electrical calibration laboratory.<\/p>\n<p>Transmille states that the 3000A Series can provide calibration capability for up to <strong>18 different instrument types<\/strong>, depending on configuration.<\/p>\n<p>The standard electrical functions already cover a broad range of calibration requirements.<\/p>\n<p>Additional internal options and external adapters allow the system to be tailored to the specific workload of the laboratory.<\/p>\n<p>This modular concept means that a laboratory can start with the required core functions and expand the system when additional calibration capabilities are needed.<\/p>\n<h2>Precision DC Voltage Calibration<\/h2>\n<p>DC voltage is one of the core functions of the <strong>Transmille 3041A<\/strong>.<\/p>\n<p>The calibrator generates DC voltage from low-level signals up to:<\/p>\n<p><strong>\u00b11000 V<\/strong><\/p>\n<p>with best one-year total accuracy of:<\/p>\n<p><strong>\u00b125 ppm<\/strong><\/p>\n<p>This performance makes the 3041A suitable for calibration of high-quality digital multimeters as well as a wide variety of general electrical measuring instruments.<\/p>\n<p>Typical applications include calibration of:<\/p>\n<ul>\n<li>Handheld multimeters<\/li>\n<li>Bench multimeters<\/li>\n<li>Digital voltmeters<\/li>\n<li>Analog voltmeters<\/li>\n<li>Panel meters<\/li>\n<li>Data acquisition systems<\/li>\n<li>Process measurement equipment<\/li>\n<\/ul>\n<p>The broad output range allows low and high voltage ranges of suitable instruments to be calibrated using one source.<\/p>\n<h2>DC Current up to 30 A<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> provides direct DC current generation up to:<\/p>\n<p><strong>\u00b130 A<\/strong><\/p>\n<p>with best one-year total accuracy of:<\/p>\n<p><strong>\u00b150 ppm<\/strong><\/p>\n<p>Direct 30 A capability is particularly useful for multimeter calibration because high-current ranges can be tested without an additional current amplifier for many common workloads.<\/p>\n<p>This reduces setup complexity and the number of external devices required on the calibration bench.<\/p>\n<h2>AC Voltage up to 500 kHz<\/h2>\n<p>The Transmille 3041A provides broad AC voltage capability.<\/p>\n<p>AC voltage extends from approximately:<\/p>\n<p><strong>20 mV to 1000 V<\/strong><\/p>\n<p>with frequencies from:<\/p>\n<p><strong>10 Hz to 500 kHz<\/strong><\/p>\n<p>on applicable ranges.<\/p>\n<p>Best one-year total AC voltage accuracy is specified down to approximately:<\/p>\n<p><strong>0.04 %<\/strong><\/p>\n<p>depending on voltage and frequency.<\/p>\n<p>The combination of wide voltage and frequency coverage enables calibration of AC functions on a broad range of digital and analog multimeters.<\/p>\n<h2>AC Current up to 30 A<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> also generates AC current from approximately:<\/p>\n<p><strong>20 \u00b5A to 30 A<\/strong><\/p>\n<p>over frequencies from:<\/p>\n<p><strong>10 Hz to 10 kHz<\/strong><\/p>\n<p>with best one-year total accuracy down to approximately:<\/p>\n<p><strong>0.06 %<\/strong><\/p>\n<p>depending on range and frequency.<\/p>\n<p>The broad current range enables both low-current and high-current ranges of suitable electrical instruments to be calibrated directly.<\/p>\n<h2>Resistance up to 1 G\u03a9<\/h2>\n<p>Resistance calibration is integrated into the Transmille 3041A.<\/p>\n<p>The passive resistance capability extends to:<\/p>\n<p><strong>1 G\u03a9<\/strong><\/p>\n<p>with best one-year total accuracy down to:<\/p>\n<p><strong>40 ppm<\/strong><\/p>\n<p>for applicable ranges.<\/p>\n<p>This broad resistance capability enables calibration of resistance functions on:<\/p>\n<ul>\n<li>Digital multimeters<\/li>\n<li>Bench multimeters<\/li>\n<li>Resistance meters<\/li>\n<li>Process instrumentation<\/li>\n<li>Electrical test equipment<\/li>\n<\/ul>\n<p>The 1 G\u03a9 upper range provides significantly broader resistance coverage than many general-purpose multifunction calibrators.<\/p>\n<h2>Capacitance Calibration<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> provides passive capacitance values from:<\/p>\n<p><strong>1 nF to 10 \u00b5F<\/strong><\/p>\n<p>with best one-year total accuracy of approximately:<\/p>\n<p><strong>0.25 %<\/strong><\/p>\n<p>for applicable values.<\/p>\n<p>Capacitance capability allows suitable multimeters and capacitance measuring instruments to be calibrated without requiring a completely separate capacitance standard for the standard workload.<\/p>\n<p>Optional functions can further extend the capacitance capabilities of the platform.<\/p>\n<h2>Frequency Generation up to 10 MHz<\/h2>\n<p>Frequency generation is available from:<\/p>\n<p><strong>1 Hz to 10 MHz<\/strong><\/p>\n<p>with standard best one-year total accuracy of:<\/p>\n<p><strong>20 ppm<\/strong><\/p>\n<p>For laboratories requiring improved frequency performance, Transmille offers an optional high-stability frequency output with accuracy down to:<\/p>\n<p><strong>1 ppm<\/strong><\/p>\n<p>This makes the 3041A suitable for calibration of frequency functions on multimeters, process instruments and suitable frequency measuring equipment.<\/p>\n<h2>Thermocouple Calibration<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> supports a broad range of thermocouple characteristics.<\/p>\n<p>Supported thermocouple types include common industrial types such as:<\/p>\n<p><strong>J, K, T, R, S, B, N and E<\/strong><\/p>\n<p>as well as additional supported characteristics.<\/p>\n<p>Best one-year total performance is specified down to approximately:<\/p>\n<p><strong>\u00b10.09 \u00b0C<\/strong><\/p>\n<p>for applicable thermocouple types and conditions.<\/p>\n<p>The optional external thermocouple adapter provides an effective method for thermocouple simulation and measurement while placing the cold junction close to the device under test.<\/p>\n<h2>Calibration of Digital Multimeters<\/h2>\n<p>One of the primary applications for the <strong>Transmille 3041A<\/strong> is digital multimeter calibration.<\/p>\n<p>A modern digital multimeter can include:<\/p>\n<ul>\n<li>DC voltage<\/li>\n<li>AC voltage<\/li>\n<li>DC current<\/li>\n<li>AC current<\/li>\n<li>Resistance<\/li>\n<li>Capacitance<\/li>\n<li>Frequency<\/li>\n<li>Temperature<\/li>\n<\/ul>\n<p>The 3041A covers these core quantities from one calibration platform.<\/p>\n<p>This can significantly simplify calibration procedures compared with using separate standards for every measurement function.<\/p>\n<h2>Calibration of Analog Instruments<\/h2>\n<p>The Transmille 3000A Series is not limited to modern digital instruments.<\/p>\n<p>The platform has sufficient output capability to drive many older analog instruments.<\/p>\n<p>This is important for calibration laboratories that maintain a mixed workload containing both modern digital measurement equipment and legacy analog devices.<\/p>\n<p>The <strong>Transmille 3041A<\/strong> therefore provides a practical solution for laboratories with a diverse electrical calibration workload.<\/p>\n<h2>Optional Power Calibration<\/h2>\n<p>The workload of the Transmille 3041A can be expanded with the <strong>PWRSINE<\/strong> option.<\/p>\n<p>This option enables calibration of power and wattmeters by dynamically controlling the phase relationship between voltage and current outputs.<\/p>\n<p>For more advanced power quality applications, the <strong>PWRDDS<\/strong> option expands this functionality with the ability to simulate:<\/p>\n<ul>\n<li>Harmonics<\/li>\n<li>Distortion<\/li>\n<li>Dropouts<\/li>\n<li>Flicker<\/li>\n<li>Custom waveforms<\/li>\n<\/ul>\n<p>This allows the 3041A platform to be configured for considerably more advanced power measurement calibration.<\/p>\n<h2>Optional Oscilloscope Calibration<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> can also be expanded for oscilloscope calibration.<\/p>\n<p>Transmille offers internal oscilloscope options for the 3000A platform.<\/p>\n<p>For the 3041A, options are available to extend the workload into oscilloscope calibration, including bandwidth-related applications.<\/p>\n<p>This allows a laboratory to combine conventional multimeter calibration and oscilloscope calibration within the same multiproduct platform.<\/p>\n<h2>Optional Inductance<\/h2>\n<p>For laboratories calibrating LCR and RLC meters, Transmille offers an internal inductance option.<\/p>\n<p>The option provides eight precision inductance values covering:<\/p>\n<p><strong>1 mH to 10 H<\/strong><\/p>\n<p>Intermediate values include 19 mH and 29 mH, which can be useful for linearity checks.<\/p>\n<p>Adding inductance capability further expands the range of instrument types that can be calibrated with the 3041A.<\/p>\n<h2>Optional Precision PRT Output<\/h2>\n<p>A precision four-wire PRT output is also available for the 3000A platform.<\/p>\n<p>This option is designed for compatibility with both DC temperature measuring instruments and AC bridges.<\/p>\n<p>It provides another route for expanding the Transmille 3041A beyond conventional electrical calibration.<\/p>\n<h2>Variable Resistance and Capacitance<\/h2>\n<p>The optional <strong>SIMRC<\/strong> function adds variable resistance and simulated capacitance outputs.<\/p>\n<p>This provides greater flexibility than the passive standard values included with the base instrument.<\/p>\n<p>Variable outputs are particularly useful when a calibration procedure requires specific test points rather than only fixed passive standard values.<\/p>\n<h2>Picoampere Calibration<\/h2>\n<p>Modern high-performance multimeters increasingly include very low current ranges.<\/p>\n<p>Transmille offers an external picoamp source adapter for the 3000A Series.<\/p>\n<p>The adapter provides accurate current generation at picoampere levels and is designed for calibration of sensitive low-current measuring instruments.<\/p>\n<p>It can be controlled from the calibrator or used as part of an automated ProCal procedure.<\/p>\n<h2>High-Resistance Measurement<\/h2>\n<p>External accessories can also expand the system into very high resistance and low-current applications.<\/p>\n<p>Transmille offers accessories capable of measuring high resistance values up to:<\/p>\n<p><strong>1 T\u03a9<\/strong><\/p>\n<p>and very low currents with picoampere-level resolution.<\/p>\n<p>This modular approach allows the 3041A platform to cover specialist calibration applications without permanently integrating every function into the main calibrator.<\/p>\n<h2>Environmental Measurement<\/h2>\n<p>The optional Transmille environmental measurement adapter can measure laboratory conditions such as:<\/p>\n<p><strong>10 % to 90 % relative humidity<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>0 \u00b0C to 50 \u00b0C temperature<\/strong><\/p>\n<p>Environmental data can be useful in calibration laboratories where temperature and humidity need to be recorded as part of the calibration process.<\/p>\n<h2>Automated Calibration with ProCal<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> is supported directly by <strong>ProCal Version 6<\/strong>.<\/p>\n<p>Transmille also lists automatic uncertainty support for this model.<\/p>\n<p>This allows calibration procedures to control the calibrator automatically and use its specification data as part of uncertainty-related functions within the software.<\/p>\n<p>Automated calibration can help:<\/p>\n<ul>\n<li>Increase calibration throughput<\/li>\n<li>Reduce repetitive manual operations<\/li>\n<li>Reduce transcription errors<\/li>\n<li>Standardize calibration procedures<\/li>\n<li>Improve consistency<\/li>\n<li>Simplify measurement data collection<\/li>\n<\/ul>\n<p>This is particularly valuable for laboratories processing large numbers of similar instruments.<\/p>\n<h2>Flexible Laboratory Integration<\/h2>\n<p>The Transmille 3041A can be used as a standalone laboratory calibrator or integrated into an automated calibration system.<\/p>\n<p>USB connectivity supports modern computer-controlled calibration systems.<\/p>\n<p>GPIB and RS232 options are also available for laboratories that need compatibility with existing automation infrastructure.<\/p>\n<p>Rack mounting solutions are available for integration into fixed calibration systems.<\/p>\n<h2>I-Guard Output Protection<\/h2>\n<p>The current Transmille 3000A platform includes the manufacturer&#8217;s <strong>I-Guard<\/strong> output protection system.<\/p>\n<p>This provides protection for the calibrator outputs and is particularly useful in busy calibration environments where instruments are connected and disconnected frequently.<\/p>\n<p>Output protection helps reduce the risk of damage caused by incorrect connections during routine calibration work.<\/p>\n<h2>3041A Compared with the 3010A and 3050A<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> occupies the middle position within the 3000A Series.<\/p>\n<p>The 3050A provides best DC voltage accuracy of approximately:<\/p>\n<p><strong>50 ppm<\/strong><\/p>\n<p>while the 3041A improves this to:<\/p>\n<p><strong>25 ppm<\/strong><\/p>\n<p>and the 3010A provides approximately:<\/p>\n<p><strong>8 ppm<\/strong>.<\/p>\n<p>The 3041A also provides direct current output up to:<\/p>\n<p><strong>30 A<\/strong><\/p>\n<p>compared with 22 A for the 3050A.<\/p>\n<p>Resistance extends to:<\/p>\n<p><strong>1 G\u03a9<\/strong><\/p>\n<p>compared with 100 M\u03a9 on the 3050A.<\/p>\n<p>The 3010A also provides 30 A and 1 G\u03a9 capability but offers higher accuracy for demanding laboratory applications.<\/p>\n<p>The 3041A therefore provides a strong balance between precision, workload coverage and system capability within the 3000A Series.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Transmille 3041A<\/th>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Precision Multiproduct Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Best DC voltage accuracy<\/td>\n<td>\u00b125 ppm<\/td>\n<\/tr>\n<tr>\n<td>DC voltage<\/td>\n<td>Up to \u00b11000 V<\/td>\n<\/tr>\n<tr>\n<td>Best DC current accuracy<\/td>\n<td>\u00b150 ppm<\/td>\n<\/tr>\n<tr>\n<td>DC current<\/td>\n<td>Up to \u00b130 A<\/td>\n<\/tr>\n<tr>\n<td>AC voltage<\/td>\n<td>20 mV to 1000 V<\/td>\n<\/tr>\n<tr>\n<td>AC voltage frequency<\/td>\n<td>10 Hz to 500 kHz<\/td>\n<\/tr>\n<tr>\n<td>Best AC voltage accuracy<\/td>\n<td>Approx. 0.04 %<\/td>\n<\/tr>\n<tr>\n<td>AC current<\/td>\n<td>20 \u00b5A to 30 A<\/td>\n<\/tr>\n<tr>\n<td>AC current frequency<\/td>\n<td>10 Hz to 10 kHz<\/td>\n<\/tr>\n<tr>\n<td>Best AC current accuracy<\/td>\n<td>Approx. 0.06 %<\/td>\n<\/tr>\n<tr>\n<td>Resistance<\/td>\n<td>Up to 1 G\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Best resistance accuracy<\/td>\n<td>40 ppm<\/td>\n<\/tr>\n<tr>\n<td>Passive capacitance<\/td>\n<td>1 nF to 10 \u00b5F<\/td>\n<\/tr>\n<tr>\n<td>Best capacitance accuracy<\/td>\n<td>Approx. 0.25 %<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>1 Hz to 10 MHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency accuracy<\/td>\n<td>20 ppm, optional 1 ppm<\/td>\n<\/tr>\n<tr>\n<td>Thermocouples<\/td>\n<td>Multiple industrial types<\/td>\n<\/tr>\n<tr>\n<td>Best thermocouple performance<\/td>\n<td>Approx. \u00b10.09 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Automation<\/td>\n<td>ProCal 6<\/td>\n<\/tr>\n<tr>\n<td>Automatic uncertainties<\/td>\n<td>Supported in ProCal 6<\/td>\n<\/tr>\n<tr>\n<td>Expansion<\/td>\n<td>Internal and external options<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why Choose the Transmille 3041A?<\/h2>\n<p>The <strong>Transmille 3041A<\/strong> combines precision electrical generation with exceptionally broad workload coverage.<\/p>\n<p>DC voltage accuracy down to <strong>\u00b125 ppm<\/strong> provides the performance required for professional electrical calibration, while voltage output up to <strong>1000 V<\/strong> and direct current output up to <strong>30 A<\/strong> cover a large proportion of common multimeter calibration requirements.<\/p>\n<p>AC voltage capability up to <strong>500 kHz<\/strong>, AC current up to <strong>30 A<\/strong>, resistance up to <strong>1 G\u03a9<\/strong>, capacitance and frequency generation up to <strong>10 MHz<\/strong> further expand the standard workload.<\/p>\n<p>Thermocouple capability allows temperature-related electrical instruments to be included in the calibration process.<\/p>\n<p>A comprehensive selection of options can add power, power quality, oscilloscope, inductance, PRT, variable resistance and specialist low-current capabilities.<\/p>\n<p>This modular architecture means the 3041A can grow with the requirements of the calibration laboratory.<\/p>\n<p>Compatibility with Transmille ProCal 6 provides a route to automated calibration and automatic uncertainty support, helping laboratories improve consistency and throughput.<\/p>\n<p>For professional calibration laboratories requiring a balance between accuracy, broad workload coverage and expandability, the Transmille 3041A provides a comprehensive multiproduct calibration platform.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional solutions for electrical calibration and automated calibration laboratories. We can assist with selecting the appropriate Transmille 3041A options and accessories for your individual calibration workload.<\/p>\n<p>For professional calibration and metrological traceability of the Transmille 3041A and other electrical calibration equipment, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/en\/\">Discover more calibration equipment from europascal here.<\/a><\/p>\n<p>Manufacturer information about the <strong>Transmille 3041A<\/strong> is available on the <a href=\"https:\/\/www.transmille.com\/product\/3041a\/\" target=\"_blank\" rel=\"noopener\">official Transmille 3041A product page<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Transmille 3041A<\/strong> is a precise multiproduct calibrator for professional electrical calibration laboratories. It provides <strong>\u00b125 ppm DC voltage accuracy, voltage up to 1000 V, current up to 30 A, resistance up to 1 G\u03a9<\/strong>, capacitance, frequency up to <strong>10 MHz<\/strong> and thermocouple simulation. Extensive internal and external options expand the 3041A for power, oscilloscope, inductance and other specialist calibration applications.<\/p>\n","protected":false},"featured_media":6514,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[77],"product_cat":[62,1242],"product_tag":[4870,3912,3914,4872,4873,4915,4916,4917,4918,4906,3918,3919,3920,3921,3922,4735,3925,4919,3926,4737,3928,3929,4920,4880,4742],"class_list":["post-6515","product","type-product","status-publish","has-post-thumbnail","product_brand-transmille","product_cat-electrical","product_cat-digital-multimeter","product_tag-1-gohm-kalibrator","product_tag-10-mhz-kalibrator","product_tag-1000-v-kalibrator","product_tag-25-ppm-kalibrator","product_tag-30-a-kalibrator","product_tag-3010a","product_tag-3050a","product_tag-9041a","product_tag-analogmultimeter-kalibrieren","product_tag-digitalmultimeter-kalibrieren","product_tag-elektrische-kalibrierung","product_tag-elektrischer-kalibrator","product_tag-europascal","product_tag-frequenzkalibrator","product_tag-kalibrierlabor","product_tag-kapazitaetskalibrator","product_tag-multifunktionskalibrator","product_tag-multimeter-kalibrator","product_tag-multiproduktkalibrator","product_tag-praezisionskalibrator","product_tag-procal","product_tag-thermoelement-kalibrator","product_tag-transmille-3000a-series","product_tag-transmille-3041a","product_tag-widerstandskalibrator","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6515","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6514"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6515"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6515"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6515"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6515"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}