{"id":6523,"date":"2026-09-10T11:19:26","date_gmt":"2026-09-10T11:19:26","guid":{"rendered":"https:\/\/europascal.de\/product\/transmille-1000b\/"},"modified":"2026-09-29T08:08:04","modified_gmt":"2026-09-29T08:08:04","slug":"transmille-1000b","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/transmille-1000b\/","title":{"rendered":"Transmille 1000B Compact Multiproduct Calibrator"},"content":{"rendered":"<p><strong>Transmille 1000B<\/strong> is a compact multiproduct calibrator designed for professional electrical calibration laboratories requiring broad functionality in a space-saving benchtop format. Combining AC and DC voltage, AC and DC current, resistance, capacitance, frequency and thermocouple simulation, the 1000B provides the essential functions required for calibration of a wide variety of electrical measuring instruments.<\/p>\n<p>With best one-year DC voltage accuracy of <strong>\u00b180 ppm<\/strong>, voltage output up to <strong>1000 V<\/strong>, current output up to <strong>10 A<\/strong>, resistance up to <strong>100 M\u03a9<\/strong> and frequency generation up to <strong>100 MHz<\/strong>, the Transmille 1000B provides extensive electrical calibration capability from one compact platform.<\/p>\n<p>The 1000B is the benchtop version of Transmille&#8217;s 1000 Series. While the 1000A is designed specifically for portable and on-site applications, the <strong>Transmille 1000B<\/strong> provides the same basic multiproduct calibration concept in a conventional laboratory housing.<\/p>\n<p>Its compact dimensions and weight of approximately <strong>9.5 kg<\/strong> make the instrument particularly attractive for calibration laboratories where bench space is limited.<\/p>\n<p>The 1000B can also be expanded with Transmille accessories and options for clamp meters, thermocouple instruments, process instruments, insulation testers, continuity testers, tachometers and other specialist calibration applications.<\/p>\n<p>Full compatibility with Transmille ProCal software provides a route to automated calibration and increased laboratory throughput.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional solutions for electrical calibration, precision measurement and automated calibration laboratories. The Transmille 1000B offers an efficient entry into multiproduct calibration for laboratories requiring broad workload coverage without the size and complexity of a larger calibration system.<\/p>\n<p>For professional calibration and metrological traceability of electrical calibrators and measuring equipment, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> combines broad electrical calibration capability with a compact benchtop design.<\/p>\n<p>Key benefits include:<\/p>\n<ul>\n<li>Compact benchtop multiproduct calibrator<\/li>\n<li>Best DC voltage accuracy of \u00b180 ppm<\/li>\n<li>DC voltage up to \u00b11000 V<\/li>\n<li>DC current up to \u00b110 A<\/li>\n<li>AC voltage up to 1000 V<\/li>\n<li>AC current up to 10 A<\/li>\n<li>Passive resistance up to 100 M\u03a9<\/li>\n<li>Passive capacitance from 10 nF to 1 \u00b5F<\/li>\n<li>Frequency generation from 1 Hz to 100 MHz<\/li>\n<li>Thermocouple simulation<\/li>\n<li>Optional clamp meter calibration<\/li>\n<li>Optional insulation tester calibration<\/li>\n<li>Optional continuity tester calibration<\/li>\n<li>Optional process control calibration<\/li>\n<li>Optional tachometer calibration<\/li>\n<li>USB interface<\/li>\n<li>Full compatibility with Transmille ProCal<\/li>\n<li>Suitable for automated calibration<\/li>\n<li>Compact dimensions<\/li>\n<li>Weight of approximately 9.5 kg<\/li>\n<li>Ideal for fixed laboratory applications<\/li>\n<\/ul>\n<h2>Compact Multiproduct Calibration<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> is designed to provide the core functionality of a multiproduct electrical calibrator in a compact benchtop instrument.<\/p>\n<p>Electrical calibration laboratories often need to generate several different quantities when calibrating a modern digital multimeter.<\/p>\n<p>These can include:<\/p>\n<ul>\n<li>DC voltage<\/li>\n<li>AC voltage<\/li>\n<li>DC current<\/li>\n<li>AC current<\/li>\n<li>Resistance<\/li>\n<li>Capacitance<\/li>\n<li>Frequency<\/li>\n<li>Temperature<\/li>\n<\/ul>\n<p>Instead of using separate standards for each measurement quantity, the 1000B combines these functions in one calibration platform.<\/p>\n<p>This can simplify the laboratory setup, reduce the number of individual standards and improve calibration efficiency.<\/p>\n<h2>DC Voltage up to 1000 V<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> provides DC voltage output from low levels up to:<\/p>\n<p><strong>\u00b11000 V<\/strong><\/p>\n<p>with best one-year total accuracy of:<\/p>\n<p><strong>\u00b180 ppm<\/strong><\/p>\n<p>This performance provides useful coverage for calibration of many handheld and bench digital multimeters.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Digital multimeters<\/li>\n<li>Analog multimeters<\/li>\n<li>Digital voltmeters<\/li>\n<li>Panel meters<\/li>\n<li>Process instrumentation<\/li>\n<li>Data acquisition equipment<\/li>\n<li>Electrical test equipment<\/li>\n<\/ul>\n<p>The 1000 V output capability allows high-voltage multimeter ranges to be calibrated directly.<\/p>\n<h2>DC Current up to 10 A<\/h2>\n<p>The Transmille 1000B generates DC current up to:<\/p>\n<p><strong>\u00b110 A<\/strong><\/p>\n<p>with best one-year total accuracy of approximately:<\/p>\n<p><strong>\u00b10.05 %<\/strong><\/p>\n<p>This provides direct calibration capability for the standard current ranges found on many handheld and bench multimeters.<\/p>\n<p>The ability to generate 10 A directly reduces the need for additional external current sources for routine multimeter calibration.<\/p>\n<p>For higher-current clamp meter applications, an optional multi-turn current coil can significantly increase the effective current.<\/p>\n<h2>AC Voltage up to 1000 V<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> also provides AC voltage output up to:<\/p>\n<p><strong>1000 V<\/strong><\/p>\n<p>with best one-year total accuracy of approximately:<\/p>\n<p><strong>\u00b10.08 %<\/strong><\/p>\n<p>The AC voltage capability allows suitable multimeters and other electrical instruments to be calibrated over their AC measurement ranges.<\/p>\n<p>Combining AC and DC voltage generation within one compact instrument helps reduce the complexity of the calibration bench.<\/p>\n<h2>AC Current up to 10 A<\/h2>\n<p>AC current generation extends to:<\/p>\n<p><strong>10 A<\/strong><\/p>\n<p>with best one-year total accuracy of approximately:<\/p>\n<p><strong>\u00b10.1 %<\/strong><\/p>\n<p>This enables calibration of common AC current ranges on digital and analog measuring instruments.<\/p>\n<p>Together with the DC current function, the 1000B provides comprehensive current calibration capability for general-purpose electrical instruments.<\/p>\n<h2>Resistance up to 100 M\u03a9<\/h2>\n<p>Resistance generation is integrated into the <strong>Transmille 1000B<\/strong>.<\/p>\n<p>Passive resistance extends up to:<\/p>\n<p><strong>100 M\u03a9<\/strong><\/p>\n<p>with best one-year total accuracy down to approximately:<\/p>\n<p><strong>\u00b10.02 %<\/strong><\/p>\n<p>This broad resistance capability makes the 1000B suitable for calibration of resistance functions on:<\/p>\n<ul>\n<li>Digital multimeters<\/li>\n<li>Bench multimeters<\/li>\n<li>Resistance meters<\/li>\n<li>Process instrumentation<\/li>\n<li>Electrical test equipment<\/li>\n<\/ul>\n<p>The integrated resistance capability eliminates the need for a large set of individual resistance standards for many routine calibration applications.<\/p>\n<h2>Capacitance Calibration<\/h2>\n<p>The Transmille 1000B provides passive capacitance values from:<\/p>\n<p><strong>10 nF to 1 \u00b5F<\/strong><\/p>\n<p>with best one-year total accuracy of approximately:<\/p>\n<p><strong>0.8 %<\/strong><\/p>\n<p>This allows capacitance measurement functions on suitable digital multimeters and other electrical instruments to be included in the calibration workload.<\/p>\n<h2>Frequency up to 100 MHz<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> provides an exceptionally broad frequency range for a compact multiproduct calibrator.<\/p>\n<p>Frequency generation extends from:<\/p>\n<p><strong>1 Hz to 100 MHz<\/strong><\/p>\n<p>with best one-year total accuracy of approximately:<\/p>\n<p><strong>20 ppm<\/strong><\/p>\n<p>This capability enables calibration of frequency functions on suitable:<\/p>\n<ul>\n<li>Digital multimeters<\/li>\n<li>Frequency meters<\/li>\n<li>Process instruments<\/li>\n<li>Electronic test equipment<\/li>\n<\/ul>\n<p>The 100 MHz upper frequency capability significantly expands the potential workload beyond basic low-frequency electrical calibration.<\/p>\n<h2>Thermocouple Simulation<\/h2>\n<p>Temperature-related electrical measurement can also be incorporated into the calibration workload.<\/p>\n<p>The Transmille 1000B supports multiple thermocouple characteristics including common industrial types such as:<\/p>\n<p><strong>J, K, T, R, S, B, N and E<\/strong><\/p>\n<p>as well as additional characteristics supported by Transmille.<\/p>\n<p>Best one-year total thermocouple performance is specified down to approximately:<\/p>\n<p><strong>\u00b10.22 \u00b0C<\/strong><\/p>\n<p>depending on thermocouple type and operating conditions.<\/p>\n<h2>External Thermocouple Adapter<\/h2>\n<p>For thermocouple calibration, Transmille offers the <strong>EA001A Thermocouple Simulation &amp; Measurement Adapter<\/strong>.<\/p>\n<p>The external adapter is designed to minimize errors associated with low-level thermocouple signals.<\/p>\n<p>By keeping these signals away from heat-generating components within the main calibrator, localized thermal EMF effects can be reduced.<\/p>\n<p>The adapter also measures the cold-junction temperature close to the connection of the device under test.<\/p>\n<p>Using a dedicated thermocouple plug eliminates the requirement for separate compensation cables for every thermocouple type.<\/p>\n<h2>Clamp Meter Calibration<\/h2>\n<p>The standard current output of the <strong>Transmille 1000B<\/strong> extends to 10 A.<\/p>\n<p>For higher-current clamp meter calibration, the system can be combined with the optional <strong>EA002 2\/10\/50 Turn Coil Adapter<\/strong>.<\/p>\n<p>The multi-turn coil multiplies the effective ampere-turn value seen by the clamp meter.<\/p>\n<p>The EA002 can be used with both AC and DC current and provides:<\/p>\n<ul>\n<li>2-turn coil<\/li>\n<li>10-turn coil<\/li>\n<li>50-turn coil<\/li>\n<\/ul>\n<p>The adapter supports calibration of clamp meters at effective currents up to <strong>1500 A<\/strong> when driven by a compatible 30 A Transmille calibrator. With the 10 A output of the 1000B, the available effective current depends on the selected number of turns.<\/p>\n<p>This provides a convenient method for expanding the clamp meter calibration workload without requiring a dedicated high-current source.<\/p>\n<h2>Optional Insulation Tester Calibration<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> can be equipped with the optional <strong>INS insulation test function<\/strong>.<\/p>\n<p>This expands the calibrator for calibration of insulation and installation testers.<\/p>\n<p>The option provides:<\/p>\n<ul>\n<li>Simulated insulation resistance<\/li>\n<li>Simulated continuity resistance<\/li>\n<li>Test voltage measurement<\/li>\n<li>Test current measurement<\/li>\n<\/ul>\n<p>Transmille specifies support for insulation testers up to:<\/p>\n<p><strong>1000 V \/ 1 G\u03a9<\/strong><\/p>\n<p>with the appropriate 1000 Series option.<\/p>\n<p>This considerably expands the workload beyond conventional multimeter calibration.<\/p>\n<h2>Continuity Tester Calibration<\/h2>\n<p>The optional insulation and installation tester functionality also provides continuity calibration capability.<\/p>\n<p>The 1000 Series can generate variable continuity resistance and measure continuity test current.<\/p>\n<p>Transmille specifies continuity test current measurement up to:<\/p>\n<p><strong>320 mA<\/strong><\/p>\n<p>This allows suitable continuity testers and multifunction installation testers to be calibrated using the same platform.<\/p>\n<h2>Process Control Calibration<\/h2>\n<p>The workload of the <strong>Transmille 1000B<\/strong> can also be expanded with the <strong>EA022 Process Control Calibration Adapter<\/strong>.<\/p>\n<p>This external adapter is designed to measure source functions from process control instruments.<\/p>\n<p>Its capabilities include:<\/p>\n<ul>\n<li>Voltage measurement up to 30 V<\/li>\n<li>Current measurement up to 30 A<\/li>\n<li>2-wire resistance measurement<\/li>\n<li>4-wire resistance measurement<\/li>\n<li>Resistance up to 10 k\u03a9<\/li>\n<li>24 V loop supply<\/li>\n<\/ul>\n<p>This allows the 1000B platform to address additional process calibration applications.<\/p>\n<h2>Tachometer Calibration<\/h2>\n<p>The optional <strong>EA003 Optical Tachometer Calibration Adapter<\/strong> extends the 1000 Series into optical tachometer calibration.<\/p>\n<p>The adapter provides an optical LED output covering:<\/p>\n<p><strong>60 to 60,000 RPM<\/strong><\/p>\n<p>Values can be entered directly and the adapter can also be controlled through Transmille ProCal for automated calibration.<\/p>\n<p>This demonstrates the modular approach used by Transmille to expand the workload of the 1000 Series.<\/p>\n<h2>Wide Workload Coverage<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> is suitable for calibration of a broad variety of electrical instruments.<\/p>\n<p>Depending on configuration and accessories, applications can include:<\/p>\n<ul>\n<li>Digital multimeters<\/li>\n<li>Analog multimeters<\/li>\n<li>Clamp meters<\/li>\n<li>Voltage meters<\/li>\n<li>Current meters<\/li>\n<li>Resistance meters<\/li>\n<li>Capacitance meters<\/li>\n<li>Frequency meters<\/li>\n<li>Thermocouple indicators<\/li>\n<li>Insulation testers<\/li>\n<li>Continuity testers<\/li>\n<li>Installation testers<\/li>\n<li>Process control instruments<\/li>\n<li>Optical tachometers<\/li>\n<\/ul>\n<p>This broad workload makes the 1000B an attractive solution for general electrical calibration laboratories.<\/p>\n<h2>Suitable for Digital and Analog Instruments<\/h2>\n<p>The Transmille 1000 Series has been designed to provide sufficient output power for older analog instruments while maintaining the accuracy required for modern digital instruments.<\/p>\n<p>This is particularly valuable for calibration laboratories with mixed workloads.<\/p>\n<p>Older analog meters can place greater electrical loads on a calibration source than modern digital instruments with high input impedance.<\/p>\n<p>The <strong>Transmille 1000B<\/strong> provides a practical platform for supporting both instrument generations.<\/p>\n<h2>Automated Calibration<\/h2>\n<p>The 1000 Series is designed for automated calibration.<\/p>\n<p>The <strong>Transmille 1000B<\/strong> includes a USB interface for connection to a computer.<\/p>\n<p>This allows calibration procedures to control the calibrator automatically.<\/p>\n<p>Automation can help:<\/p>\n<ul>\n<li>Reduce repetitive manual operations<\/li>\n<li>Reduce setting errors<\/li>\n<li>Reduce transcription errors<\/li>\n<li>Standardize calibration procedures<\/li>\n<li>Increase calibration throughput<\/li>\n<li>Improve repeatability<\/li>\n<\/ul>\n<p>This is particularly useful for laboratories that regularly calibrate large numbers of similar instruments.<\/p>\n<h2>Transmille ProCal Software<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> is fully compatible with Transmille ProCal calibration software.<\/p>\n<p>ProCal provides a software environment for automated calibration and calibration management.<\/p>\n<p>Combining the 1000B with ProCal allows the calibrator to become part of a more comprehensive automated laboratory solution.<\/p>\n<p>This can help laboratories improve throughput while maintaining standardized calibration procedures.<\/p>\n<h2>Compact Benchtop Design<\/h2>\n<p>Unlike the portable 1000A, the <strong>Transmille 1000B<\/strong> is designed specifically for benchtop installation.<\/p>\n<p>Its dimensions are approximately:<\/p>\n<p><strong>180 mm high \u00d7 447 mm wide \u00d7 297 mm deep<\/strong><\/p>\n<p>and its weight is approximately:<\/p>\n<p><strong>9.5 kg<\/strong><\/p>\n<p>This provides a compact footprint for a multiproduct calibrator with voltage capability up to 1000 V.<\/p>\n<p>The benchtop configuration is particularly suitable for fixed electrical calibration laboratories where the calibrator does not need to be transported regularly.<\/p>\n<h2>1000B Compared with the 1000A<\/h2>\n<p>The Transmille 1000 Series is available in portable and benchtop configurations.<\/p>\n<p>The <strong>Transmille 1000B<\/strong> is the:<\/p>\n<p><strong>benchtop version<\/strong><\/p>\n<p>while the <strong>Transmille 1000A<\/strong> is the:<\/p>\n<p><strong>portable version<\/strong>.<\/p>\n<p>The 1000A is integrated into a rugged IP67 transport case and weighs approximately 9.2 kg.<\/p>\n<p>The 1000B uses a conventional benchtop housing and weighs approximately 9.5 kg.<\/p>\n<p>The core electrical performance is very similar.<\/p>\n<p>Both provide:<\/p>\n<ul>\n<li>\u00b180 ppm DC voltage accuracy<\/li>\n<li>Voltage up to 1000 V<\/li>\n<li>Current up to 10 A<\/li>\n<li>Resistance up to 100 M\u03a9<\/li>\n<li>Frequency up to 100 MHz<\/li>\n<li>Thermocouple simulation<\/li>\n<\/ul>\n<p>One difference in the currently published specifications concerns passive capacitance. Transmille specifies <strong>10 nF to 1 \u00b5F<\/strong> for the 1000B, while the 1000A is listed with a wider <strong>1 nF to 10 \u00b5F<\/strong> range.<\/p>\n<p>The main purchasing decision between the two models is therefore based on the intended application.<\/p>\n<p>The 1000A is optimized for transportation and on-site calibration, while the <strong>1000B is optimized for fixed benchtop laboratory use<\/strong>.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Transmille 1000B<\/th>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Benchtop Multiproduct Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Best DC voltage accuracy<\/td>\n<td>\u00b180 ppm<\/td>\n<\/tr>\n<tr>\n<td>DC voltage<\/td>\n<td>Up to \u00b11000 V<\/td>\n<\/tr>\n<tr>\n<td>Best DC current accuracy<\/td>\n<td>\u00b10.05 %<\/td>\n<\/tr>\n<tr>\n<td>DC current<\/td>\n<td>Up to \u00b110 A<\/td>\n<\/tr>\n<tr>\n<td>Best AC voltage accuracy<\/td>\n<td>\u00b10.08 %<\/td>\n<\/tr>\n<tr>\n<td>AC voltage<\/td>\n<td>Up to 1000 V<\/td>\n<\/tr>\n<tr>\n<td>Best AC current accuracy<\/td>\n<td>\u00b10.1 %<\/td>\n<\/tr>\n<tr>\n<td>AC current<\/td>\n<td>Up to 10 A<\/td>\n<\/tr>\n<tr>\n<td>Passive resistance<\/td>\n<td>Up to 100 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Best resistance accuracy<\/td>\n<td>\u00b10.02 %<\/td>\n<\/tr>\n<tr>\n<td>Passive capacitance<\/td>\n<td>10 nF to 1 \u00b5F<\/td>\n<\/tr>\n<tr>\n<td>Best capacitance accuracy<\/td>\n<td>0.8 %<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>1 Hz to 100 MHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency accuracy<\/td>\n<td>20 ppm<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple simulation<\/td>\n<td>Multiple industrial types<\/td>\n<\/tr>\n<tr>\n<td>Best thermocouple performance<\/td>\n<td>\u00b10.22 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Interface<\/td>\n<td>USB<\/td>\n<\/tr>\n<tr>\n<td>Software<\/td>\n<td>Transmille ProCal<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 9.5 kg<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Approx. 180 \u00d7 447 \u00d7 297 mm<\/td>\n<\/tr>\n<tr>\n<td>Design<\/td>\n<td>Benchtop<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why Choose the Transmille 1000B?<\/h2>\n<p>The <strong>Transmille 1000B<\/strong> combines the functionality of a multiproduct electrical calibrator with a compact benchtop design.<\/p>\n<p>Best DC voltage accuracy of <strong>\u00b180 ppm<\/strong>, voltage output up to <strong>1000 V<\/strong> and current output up to <strong>10 A<\/strong> provide the core capabilities required for calibration of a broad range of electrical measuring instruments.<\/p>\n<p>Passive resistance up to <strong>100 M\u03a9<\/strong>, capacitance, frequency generation from <strong>1 Hz to 100 MHz<\/strong> and thermocouple simulation further expand the standard workload.<\/p>\n<p>Optional accessories and functions can add clamp meter, insulation tester, continuity tester, process control and tachometer calibration.<\/p>\n<p>The compact dimensions of approximately <strong>180 \u00d7 447 \u00d7 297 mm<\/strong> allow the 1000B to provide substantial functionality without occupying excessive calibration bench space.<\/p>\n<p>Full compatibility with Transmille ProCal and the integrated USB interface also provide a straightforward route to automated calibration.<\/p>\n<p>Compared with the portable 1000A, the <strong>Transmille 1000B<\/strong> is particularly suitable when the calibrator will remain permanently installed in the laboratory.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional solutions for electrical calibration and automated calibration laboratories. We can assist with selecting the appropriate Transmille 1000B options and accessories for your individual calibration workload.<\/p>\n<p>For professional calibration and metrological traceability of the Transmille 1000B and other electrical calibration equipment, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/en\/\">Discover more calibration equipment from europascal here.<\/a><\/p>\n<p>Manufacturer information about the <strong>Transmille 1000B<\/strong> is available on the <a href=\"https:\/\/www.transmille.com\/product\/1000b\/\" target=\"_blank\" rel=\"noopener\">official Transmille 1000B product page<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/09\/1000-Series-Ultra-portable-Calibrator-Transmille-europascal.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Transmille 1000B<\/strong> is a compact benchtop multiproduct calibrator for professional electrical calibration laboratories. It provides <strong>\u00b180 ppm DC voltage accuracy, AC\/DC voltage up to 1000 V, AC\/DC current up to 10 A, resistance up to 100 M\u03a9<\/strong>, capacitance, frequency up to <strong>100 MHz<\/strong> and thermocouple simulation. Optional accessories expand the 1000B for clamp meters, insulation testers, continuity testers and process calibration.<\/p>\n","protected":false},"featured_media":6524,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[77],"product_cat":[62,64],"product_tag":[4924,4871,3913,3914,4918,4930,4906,3918,3919,3920,3921,3922,4735,3925,4919,4737,3928,3929,4927,4931,4932,4742],"class_list":["post-6523","product","type-product","status-publish","has-post-thumbnail","product_brand-transmille","product_cat-electrical","product_cat-process-multifunction-calibrators","product_tag-10-a-kalibrator","product_tag-100-mhz-kalibrator","product_tag-100-mohm-kalibrator","product_tag-1000-v-kalibrator","product_tag-analogmultimeter-kalibrieren","product_tag-benchtop-kalibrator","product_tag-digitalmultimeter-kalibrieren","product_tag-elektrische-kalibrierung","product_tag-elektrischer-kalibrator","product_tag-europascal","product_tag-frequenzkalibrator","product_tag-kalibrierlabor","product_tag-kapazitaetskalibrator","product_tag-multifunktionskalibrator","product_tag-multimeter-kalibrator","product_tag-praezisionskalibrator","product_tag-procal","product_tag-thermoelement-kalibrator","product_tag-transmille-1000-series","product_tag-transmille-1000b","product_tag-usb-kalibrator","product_tag-widerstandskalibrator","pa_bauart-tischgeraet","pa_hart-kommunikation-nein","pa_schnittstelle-usb-und-gpib-interfaces","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6524"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6523"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6523"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6523"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}