{"id":6529,"date":"2026-09-10T12:09:27","date_gmt":"2026-09-10T12:09:27","guid":{"rendered":"https:\/\/europascal.de\/product\/transmille-3050a\/"},"modified":"2026-09-29T08:15:16","modified_gmt":"2026-09-29T08:15:16","slug":"transmille-3050a","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/transmille-3050a\/","title":{"rendered":"Transmille 3050A Versatile Multiproduct Calibrator"},"content":{"rendered":"<p><strong>Transmille 3050A<\/strong> is a versatile multiproduct calibrator designed for professional electrical calibration laboratories requiring broad workload coverage at an attractive price-performance ratio. With DC and AC voltage up to 1000 V, DC and AC current up to 22 A, resistance up to 100 M\u03a9, capacitance, frequency and thermocouple simulation, the 3050A combines numerous electrical calibration functions in one expandable laboratory platform.<\/p>\n<p>With best one-year DC voltage accuracy of <strong>\u00b150 ppm<\/strong>, the Transmille 3050A provides the performance required for calibration of a broad range of modern digital multimeters while retaining sufficient output capability for many older analog instruments.<\/p>\n<p>The 3050A is part of Transmille&#8217;s 3000A Series of precision multiproduct calibrators. Within the series, it provides a cost-effective alternative to the higher-accuracy 3041A and 3010A while maintaining the modular architecture and broad workload coverage of the platform.<\/p>\n<p>Depending on configuration and accessories, the <strong>Transmille 3050A<\/strong> can form the core of a comprehensive electrical calibration workstation. Transmille states that the 3000A Series can cover up to <strong>18 different instrument types<\/strong>, allowing laboratories to consolidate multiple calibration applications into one system.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional solutions for electrical calibration, precision measurement and automated calibration laboratories. The Transmille 3050A can be configured with suitable options and accessories according to your individual calibration workload.<\/p>\n<p>For professional calibration and metrological traceability of electrical calibrators and measuring equipment, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> combines broad electrical calibration capability with an attractive price-performance ratio.<\/p>\n<p>Key benefits include:<\/p>\n<ul>\n<li>Precision multiproduct calibrator<\/li>\n<li>Best DC voltage accuracy of \u00b150 ppm<\/li>\n<li>DC voltage up to \u00b11000 V<\/li>\n<li>DC current up to \u00b122 A<\/li>\n<li>Best DC current accuracy of \u00b1100 ppm<\/li>\n<li>AC voltage from 20 mV to 1000 V<\/li>\n<li>Broad AC voltage frequency capability<\/li>\n<li>AC current from 20 \u00b5A to 22 A<\/li>\n<li>AC current frequency from 10 Hz to 10 kHz<\/li>\n<li>Best AC current accuracy of 0.07 %<\/li>\n<li>Passive resistance up to 100 M\u03a9<\/li>\n<li>Best resistance accuracy down to 60 ppm<\/li>\n<li>Passive capacitance from 10 nF to 1 \u00b5F<\/li>\n<li>Best capacitance accuracy of 0.25 %<\/li>\n<li>Frequency generation from 1 Hz to 10 MHz<\/li>\n<li>Frequency accuracy of 20 ppm<\/li>\n<li>Thermocouple simulation<\/li>\n<li>Best thermocouple performance down to \u00b10.09 \u00b0C<\/li>\n<li>Expandable calibration platform<\/li>\n<li>Optional oscilloscope calibration<\/li>\n<li>Optional power calibration functions<\/li>\n<li>Extensive external accessories<\/li>\n<li>Automated calibration with Transmille ProCal<\/li>\n<li>Suitable for digital and analog instruments<\/li>\n<\/ul>\n<h2>Wide Workload Coverage<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> has been designed to reduce the number of individual standards required in an electrical calibration laboratory.<\/p>\n<p>A modern digital multimeter can combine numerous measurement functions, including:<\/p>\n<ul>\n<li>DC voltage<\/li>\n<li>AC voltage<\/li>\n<li>DC current<\/li>\n<li>AC current<\/li>\n<li>Resistance<\/li>\n<li>Capacitance<\/li>\n<li>Frequency<\/li>\n<li>Temperature<\/li>\n<\/ul>\n<p>The 3050A provides the reference quantities required for these functions from one calibration platform.<\/p>\n<p>According to Transmille, the 3000A Series can be configured to calibrate up to <strong>18 different types of instrument<\/strong>.<\/p>\n<p>This makes the system particularly attractive for laboratories with diverse electrical calibration workloads.<\/p>\n<h2>DC Voltage up to 1000 V<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> provides DC voltage from low-level signals up to:<\/p>\n<p><strong>\u00b11000 V<\/strong><\/p>\n<p>with best one-year total accuracy of:<\/p>\n<p><strong>\u00b150 ppm<\/strong><\/p>\n<p>The detailed specification includes a highest DC voltage range extending to approximately 1025 V.<\/p>\n<p>This provides broad coverage for calibration of:<\/p>\n<ul>\n<li>Handheld digital multimeters<\/li>\n<li>Bench multimeters<\/li>\n<li>Digital voltmeters<\/li>\n<li>Analog voltmeters<\/li>\n<li>Panel meters<\/li>\n<li>Process instrumentation<\/li>\n<li>Data acquisition systems<\/li>\n<li>Electrical test equipment<\/li>\n<\/ul>\n<p>The combination of accuracy and high-voltage capability allows numerous voltage ranges to be calibrated from one source.<\/p>\n<h2>DC Current up to 22 A<\/h2>\n<p>The Transmille 3050A provides direct DC current generation up to:<\/p>\n<p><strong>\u00b122 A<\/strong><\/p>\n<p>with best one-year total accuracy of:<\/p>\n<p><strong>\u00b1100 ppm<\/strong><\/p>\n<p>This direct high-current capability reduces the need for an external current amplifier for many common multimeter calibration applications.<\/p>\n<p>It also provides useful capability for calibration of current meters and suitable current shunts.<\/p>\n<h2>AC Voltage Calibration<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> provides AC voltage from approximately:<\/p>\n<p><strong>20 mV to 1000 V<\/strong><\/p>\n<p>with broad frequency coverage.<\/p>\n<p>This allows AC voltage ranges on digital and analog multimeters to be calibrated using the same system as their DC functions.<\/p>\n<p>The available voltage and frequency combinations depend on the selected range and operating conditions.<\/p>\n<p>This broad AC capability is particularly useful for general electrical calibration laboratories handling many different types of multimeter.<\/p>\n<h2>AC Current up to 22 A<\/h2>\n<p>The Transmille 3050A provides AC current from approximately:<\/p>\n<p><strong>20 \u00b5A to 22 A<\/strong><\/p>\n<p>over a frequency range of:<\/p>\n<p><strong>10 Hz to 10 kHz<\/strong><\/p>\n<p>with best one-year total accuracy of approximately:<\/p>\n<p><strong>0.07 %<\/strong><\/p>\n<p>depending on range and frequency.<\/p>\n<p>The broad current range enables calibration of both low-current and high-current functions on suitable electrical measuring instruments.<\/p>\n<h2>Resistance up to 100 M\u03a9<\/h2>\n<p>Resistance calibration is integrated directly into the <strong>Transmille 3050A<\/strong>.<\/p>\n<p>Passive resistance extends to:<\/p>\n<p><strong>100 M\u03a9<\/strong><\/p>\n<p>with best one-year total accuracy down to:<\/p>\n<p><strong>60 ppm<\/strong><\/p>\n<p>for applicable resistance values.<\/p>\n<p>Transmille uses passive standard resistors in the 3000 Series, with the calibrated value displayed when the resistance is selected.<\/p>\n<p>This provides resistance calibration capability for:<\/p>\n<ul>\n<li>Digital multimeters<\/li>\n<li>Bench multimeters<\/li>\n<li>Resistance meters<\/li>\n<li>Process instruments<\/li>\n<li>Electrical test equipment<\/li>\n<\/ul>\n<p>The detailed Transmille specification provides individual accuracy values for each resistance standard.<\/p>\n<h2>Capacitance Calibration<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> provides passive capacitance values covering:<\/p>\n<p><strong>10 nF to 1 \u00b5F<\/strong><\/p>\n<p>with best one-year total accuracy of:<\/p>\n<p><strong>0.25 %<\/strong><\/p>\n<p>This enables capacitance measurement functions on suitable digital multimeters and other electrical measuring instruments to be included in the calibration workload.<\/p>\n<p>Optional functionality can further expand resistance and capacitance capabilities where required.<\/p>\n<h2>Frequency from 1 Hz to 10 MHz<\/h2>\n<p>Frequency generation is available from:<\/p>\n<p><strong>1 Hz to 10 MHz<\/strong><\/p>\n<p>with best one-year total accuracy of:<\/p>\n<p><strong>20 ppm<\/strong><\/p>\n<p>This provides a useful reference signal for calibration of frequency functions on:<\/p>\n<ul>\n<li>Digital multimeters<\/li>\n<li>Frequency measuring instruments<\/li>\n<li>Process instrumentation<\/li>\n<li>Electrical and electronic test equipment<\/li>\n<\/ul>\n<p>The integrated frequency function further reduces the requirement for separate laboratory signal sources.<\/p>\n<h2>Thermocouple Simulation<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> supports numerous thermocouple characteristics.<\/p>\n<p>The manufacturer lists thermocouple types including:<\/p>\n<p><strong>J, K, T, R, S, B, N, E, L and C<\/strong><\/p>\n<p>together with additional supported characteristics.<\/p>\n<p>Best one-year total thermocouple performance is specified down to approximately:<\/p>\n<p><strong>\u00b10.09 \u00b0C<\/strong><\/p>\n<p>depending on thermocouple type and operating conditions.<\/p>\n<p>This enables temperature indicators and thermocouple measuring instruments to be incorporated into the electrical calibration workload.<\/p>\n<h2>Calibration of Digital Multimeters<\/h2>\n<p>Digital multimeter calibration is one of the primary applications for the <strong>Transmille 3050A<\/strong>.<\/p>\n<p>Modern multimeters combine numerous electrical measurement functions in one instrument.<\/p>\n<p>Using separate standards for every function can increase calibration time and require substantial bench space.<\/p>\n<p>The 3050A combines the main electrical reference quantities into one coordinated platform.<\/p>\n<p>This makes it possible to calibrate a large proportion of a typical multimeter&#8217;s functions without repeatedly changing calibration standards.<\/p>\n<h2>Calibration of Analog Instruments<\/h2>\n<p>The Transmille 3000A Series has also been designed with older analog instrumentation in mind.<\/p>\n<p>Analog meters can place greater electrical loads on a calibration source than modern high-input-impedance digital instruments.<\/p>\n<p>The <strong>Transmille 3050A<\/strong> provides the output capability required to drive many of these older instruments while maintaining sufficient accuracy for modern digital equipment.<\/p>\n<p>This makes it useful for laboratories with mixed instrument inventories.<\/p>\n<h2>Clamp Meter Calibration<\/h2>\n<p>The current output of the 3050A can be combined with a multi-turn current coil for calibration of clamp meters.<\/p>\n<p>Transmille offers the <strong>EA002 2\/10\/50 Turn Coil Adapter<\/strong>.<\/p>\n<p>By passing the calibrator current through multiple turns, the effective ampere-turn value seen by the clamp meter is increased.<\/p>\n<p>This provides an efficient method for calibrating higher-current clamp ranges without generating the full equivalent current through a single conductor.<\/p>\n<h2>Optional Oscilloscope Calibration<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> can be expanded for oscilloscope calibration.<\/p>\n<p>Transmille lists the <strong>SCP250 option<\/strong> specifically for the 3050A.<\/p>\n<p>This option provides oscilloscope calibration capability up to:<\/p>\n<p><strong>250 MHz bandwidth<\/strong><\/p>\n<p>The oscilloscope option significantly expands the potential workload of the multiproduct calibrator beyond conventional multimeters.<\/p>\n<h2>Optional Power Calibration<\/h2>\n<p>Power calibration functionality can also be added to the 3000A platform.<\/p>\n<p>The <strong>PWRSINE option<\/strong> enables calibration of suitable power meters and wattmeters by providing a dynamically controlled phase relationship between voltage and current outputs.<\/p>\n<p>For more advanced power-quality applications, Transmille offers the <strong>PWRDDS option<\/strong>.<\/p>\n<p>PWRDDS can expand functionality to simulate:<\/p>\n<ul>\n<li>Harmonics<\/li>\n<li>Distortion<\/li>\n<li>Dropouts<\/li>\n<li>Flicker<\/li>\n<\/ul>\n<p>This provides additional capability for calibration of power meters with power-quality measurement functions.<\/p>\n<h2>Optional Variable Resistance and Capacitance<\/h2>\n<p>The <strong>SIMRC option<\/strong> expands the standard passive resistance and capacitance capability.<\/p>\n<p>SIMRC adds:<\/p>\n<ul>\n<li>Variable resistance<\/li>\n<li>Simulated capacitance<\/li>\n<\/ul>\n<p>outputs to the 3000A platform.<\/p>\n<p>This can be useful when calibration procedures require specific values that are not available from the standard passive resistance or capacitance points.<\/p>\n<h2>Optional Inductance<\/h2>\n<p>The Transmille 3000A platform can also be expanded with the <strong>IND option<\/strong>.<\/p>\n<p>This adds fixed inductance values for more comprehensive calibration of:<\/p>\n<ul>\n<li>LCR meters<\/li>\n<li>RLC meters<\/li>\n<li>Component measuring instruments<\/li>\n<\/ul>\n<p>Combining resistance, capacitance and inductance functions allows the 3050A platform to address a broader passive-component measurement workload.<\/p>\n<h2>Optional PRT Output<\/h2>\n<p>A precision four-wire PRT output is available as an option for the 3000A platform.<\/p>\n<p>The option is designed for compatibility with both:<\/p>\n<ul>\n<li>DC temperature measuring instruments<\/li>\n<li>AC resistance bridges<\/li>\n<\/ul>\n<p>This expands the multiproduct calibration platform into additional temperature-related electrical calibration applications.<\/p>\n<h2>External Accessories<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> can be combined with a broad range of external accessories.<\/p>\n<p>Depending on the required workload, accessories can extend the calibration system for applications including:<\/p>\n<ul>\n<li>Clamp meters<\/li>\n<li>Thermocouple instruments<\/li>\n<li>Optical tachometers<\/li>\n<li>Picoampere instruments<\/li>\n<li>Process instrumentation<\/li>\n<li>Pressure measurement with compatible modules<\/li>\n<li>Specialist electrical test equipment<\/li>\n<\/ul>\n<p>The modular concept allows laboratories to purchase only the capabilities they require and expand the system later when the workload changes.<\/p>\n<h2>Automated Calibration with ProCal<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> is supported by Transmille ProCal Version 6.<\/p>\n<p>Transmille also lists support for automatic uncertainties for the 3050A within ProCal 6.<\/p>\n<p>Automated calibration can help laboratories:<\/p>\n<ul>\n<li>Increase calibration throughput<\/li>\n<li>Reduce repetitive manual operations<\/li>\n<li>Reduce transcription errors<\/li>\n<li>Standardize calibration procedures<\/li>\n<li>Improve repeatability<\/li>\n<li>Simplify result recording<\/li>\n<\/ul>\n<p>This makes the 3050A suitable for both manual laboratory operation and automated calibration systems.<\/p>\n<h2>Expandable for Future Requirements<\/h2>\n<p>One of the core concepts of the Transmille 3000A Series is expandability.<\/p>\n<p>A laboratory can initially purchase the functions required for its existing workload and add additional capabilities later.<\/p>\n<p>This can provide a more economical route to broad electrical calibration capability than purchasing numerous independent calibration systems.<\/p>\n<p>The <strong>Transmille 3050A<\/strong> is particularly attractive where cost-effective entry into the 3000A platform is a priority.<\/p>\n<h2>3050A Compared with 3041A and 3010A<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> is the cost-effective model within the 3000A Series.<\/p>\n<p>For DC voltage, the models provide best one-year total accuracy of:<\/p>\n<p><strong>3050A: \u00b150 ppm<\/strong><\/p>\n<p><strong>3041A: \u00b125 ppm<\/strong><\/p>\n<p><strong>3010A: \u00b18 ppm<\/strong><\/p>\n<p>For DC current, the 3050A provides:<\/p>\n<p><strong>\u00b122 A with \u00b1100 ppm best accuracy<\/strong><\/p>\n<p>while the 3041A and 3010A provide:<\/p>\n<p><strong>\u00b130 A with \u00b150 ppm best accuracy<\/strong><\/p>\n<p>Resistance capability is:<\/p>\n<p><strong>3050A: 100 M\u03a9 with best accuracy down to 60 ppm<\/strong><\/p>\n<p><strong>3041A: 1 G\u03a9 with best accuracy down to 40 ppm<\/strong><\/p>\n<p><strong>3010A: 1 G\u03a9 with best accuracy down to 18 ppm<\/strong><\/p>\n<p>Passive capacitance is specified as:<\/p>\n<p><strong>3050A: 10 nF to 1 \u00b5F<\/strong><\/p>\n<p><strong>3041A and 3010A: 1 nF to 10 \u00b5F<\/strong><\/p>\n<p>The 3050A therefore provides a particularly attractive solution when broad multiproduct functionality is required but the higher precision and extended ranges of the 3041A or 3010A are not necessary.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Transmille 3050A<\/th>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Precision Multiproduct Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Best DC voltage accuracy<\/td>\n<td>\u00b150 ppm<\/td>\n<\/tr>\n<tr>\n<td>DC voltage<\/td>\n<td>Up to \u00b11000 V<\/td>\n<\/tr>\n<tr>\n<td>Best DC current accuracy<\/td>\n<td>\u00b1100 ppm<\/td>\n<\/tr>\n<tr>\n<td>DC current<\/td>\n<td>Up to \u00b122 A<\/td>\n<\/tr>\n<tr>\n<td>AC voltage<\/td>\n<td>20 mV to 1000 V<\/td>\n<\/tr>\n<tr>\n<td>AC current<\/td>\n<td>20 \u00b5A to 22 A<\/td>\n<\/tr>\n<tr>\n<td>AC current frequency<\/td>\n<td>10 Hz to 10 kHz<\/td>\n<\/tr>\n<tr>\n<td>Best AC current accuracy<\/td>\n<td>0.07 %<\/td>\n<\/tr>\n<tr>\n<td>Passive resistance<\/td>\n<td>Up to 100 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Best resistance accuracy<\/td>\n<td>60 ppm<\/td>\n<\/tr>\n<tr>\n<td>Passive capacitance<\/td>\n<td>10 nF to 1 \u00b5F<\/td>\n<\/tr>\n<tr>\n<td>Best capacitance accuracy<\/td>\n<td>0.25 %<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>1 Hz to 10 MHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency accuracy<\/td>\n<td>20 ppm<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple simulation<\/td>\n<td>Multiple industrial types<\/td>\n<\/tr>\n<tr>\n<td>Best thermocouple performance<\/td>\n<td>\u00b10.09 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Oscilloscope option<\/td>\n<td>Up to 250 MHz<\/td>\n<\/tr>\n<tr>\n<td>Automation<\/td>\n<td>Transmille ProCal<\/td>\n<\/tr>\n<tr>\n<td>Automatic uncertainties<\/td>\n<td>Supported in ProCal 6<\/td>\n<\/tr>\n<tr>\n<td>Expansion<\/td>\n<td>Internal and external options<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why Choose the Transmille 3050A?<\/h2>\n<p>The <strong>Transmille 3050A<\/strong> provides an attractive combination of precision, workload coverage and expandability for professional electrical calibration laboratories.<\/p>\n<p>Best DC voltage accuracy of <strong>\u00b150 ppm<\/strong> provides suitable performance for calibration of a broad range of digital multimeters, while voltage output up to <strong>1000 V<\/strong> and direct current output up to <strong>22 A<\/strong> cover many common electrical calibration requirements.<\/p>\n<p>Resistance up to <strong>100 M\u03a9<\/strong>, capacitance from <strong>10 nF to 1 \u00b5F<\/strong>, frequency generation from <strong>1 Hz to 10 MHz<\/strong> and thermocouple simulation further expand the standard workload.<\/p>\n<p>Optional functions can add power, power quality, oscilloscope, inductance, PRT and variable resistance or capacitance calibration.<\/p>\n<p>External accessories provide additional possibilities for clamp meters, tachometers and other specialist measurement equipment.<\/p>\n<p>The modular architecture allows the system to grow as the laboratory&#8217;s workload changes.<\/p>\n<p>Compared with the higher-performance 3041A and 3010A, the 3050A provides a cost-effective entry into the Transmille 3000A platform without sacrificing its fundamental multiproduct concept.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional solutions for electrical calibration and automated calibration laboratories. We can assist with selecting the appropriate Transmille 3050A options and accessories for your individual calibration workload.<\/p>\n<p>For professional calibration and metrological traceability of the Transmille 3050A and other electrical calibration equipment, use the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/en\/\">Discover more calibration equipment from europascal here.<\/a><\/p>\n<p>Manufacturer information about the <strong>Transmille 3050A<\/strong> is available on the <a href=\"https:\/\/www.transmille.com\/product\/3050a\/\" target=\"_blank\" rel=\"noopener\">official Transmille 3050A product page<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Transmille 3050A<\/strong> is a versatile multiproduct calibrator for professional electrical calibration laboratories. It provides <strong>\u00b150 ppm DC voltage accuracy, voltage up to 1000 V, current up to 22 A, resistance up to 100 M\u03a9<\/strong>, capacitance, frequency up to <strong>10 MHz<\/strong> and thermocouple simulation. Extensive options expand the 3050A for power, oscilloscope, inductance and other specialist calibration applications.<\/p>\n","protected":false},"featured_media":6530,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[77],"product_cat":[62,63],"product_tag":[3912,3913,3914,3915,3917,4918,4906,3918,3919,3920,3921,3922,4735,3925,4919,3926,4737,3928,3929,4920,4910,4880,3930,4742],"class_list":["post-6529","product","type-product","status-publish","has-post-thumbnail","product_brand-transmille","product_cat-electrical","product_cat-precision-calibrators-electrical-measuring-devices","product_tag-10-mhz-kalibrator","product_tag-100-mohm-kalibrator","product_tag-1000-v-kalibrator","product_tag-22-a-kalibrator","product_tag-50-ppm-kalibrator","product_tag-analogmultimeter-kalibrieren","product_tag-digitalmultimeter-kalibrieren","product_tag-elektrische-kalibrierung","product_tag-elektrischer-kalibrator","product_tag-europascal","product_tag-frequenzkalibrator","product_tag-kalibrierlabor","product_tag-kapazitaetskalibrator","product_tag-multifunktionskalibrator","product_tag-multimeter-kalibrator","product_tag-multiproduktkalibrator","product_tag-praezisionskalibrator","product_tag-procal","product_tag-thermoelement-kalibrator","product_tag-transmille-3000a-series","product_tag-transmille-3010a","product_tag-transmille-3041a","product_tag-transmille-3050a","product_tag-widerstandskalibrator","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6529","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6530"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6529"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6529"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6529"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6529"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}