{"id":6550,"date":"2026-07-17T16:23:17","date_gmt":"2026-07-17T16:23:17","guid":{"rendered":"https:\/\/europascal.de\/product\/additel-adt-221a\/"},"modified":"2026-09-29T09:09:44","modified_gmt":"2026-09-29T09:09:44","slug":"additel-adt-221a","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-adt-221a\/","title":{"rendered":"Additel ADT221A Versatile Temperature Calibrator"},"content":{"rendered":"<p><strong>Additel ADT221A<\/strong> is a versatile multifunction temperature calibrator designed for sourcing, simulating and measuring temperature and electrical signals. Combining RTD and thermocouple calibration with mV, V, mA, resistance, frequency and pulse functions, the ADT221A provides a comprehensive portable solution for calibration laboratories, service technicians and industrial maintenance applications.<\/p>\n<p>A major advantage of the Additel ADT221A is its ability to measure and simulate a wide variety of temperature sensors. The calibrator supports <strong>13 thermocouple types and 11 RTD types<\/strong>, allowing users to calibrate temperature transmitters, indicators, recorders, controllers and other temperature measurement equipment with one compact handheld instrument.<\/p>\n<p>The ADT221A also incorporates full documenting capabilities. Calibration tasks can be created directly on the instrument, automated tests can be performed and results can be stored internally. As-found and as-left data can be documented, making the calibrator particularly useful for quality-controlled calibration processes.<\/p>\n<p>Additel equips the ADT221A with a special internal cold junction compensation system. A calibrated PRT element is installed in the cold junction equalizing block and can be removed for recalibration and correction at the ice point. This design provides an important advantage for users who require reliable and traceable thermocouple calibration.<\/p>\n<p>Despite its extensive functionality, the ADT221A remains compact. Its dimensions are approximately <strong>100 \u00d7 192 \u00d7 52 mm<\/strong>, and the instrument weighs only about <strong>0.7 kg<\/strong>.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional solutions for temperature measurement and calibration technology. The Additel ADT221A is particularly suitable when electrical temperature simulation and measurement need to be combined with documentation and automated calibration procedures in one portable instrument.<\/p>\n<p>For professional calibration and metrological traceability of temperature and electrical measuring instruments, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> combines comprehensive temperature calibration functions with electrical measurement, signal generation and documentation capabilities.<\/p>\n<p>Key benefits include:<\/p>\n<ul>\n<li>Multifunction temperature calibrator<\/li>\n<li>Measurement and simulation of RTDs<\/li>\n<li>Measurement and simulation of thermocouples<\/li>\n<li>Supports 13 thermocouple types<\/li>\n<li>Supports 11 RTD types<\/li>\n<li>mV measurement and source<\/li>\n<li>Voltage measurement and source<\/li>\n<li>Current measurement and source<\/li>\n<li>Resistance measurement and source<\/li>\n<li>Frequency measurement and source<\/li>\n<li>Pulse measurement and source<\/li>\n<li>24 V loop power supply<\/li>\n<li>Simultaneous dual reading capability<\/li>\n<li>Automatic switch test<\/li>\n<li>Square root transmitter support<\/li>\n<li>Pulse frequency output for flow totalizer calibration<\/li>\n<li>Documenting calibration capability<\/li>\n<li>Automated calibration procedures<\/li>\n<li>As-found and as-left documentation<\/li>\n<li>Internal data storage<\/li>\n<li>Calibrated cold junction compensation<\/li>\n<li>Removable PRT cold junction sensor<\/li>\n<li>Smartphone-like menu structure<\/li>\n<li>Compact handheld design<\/li>\n<li>One-handed operation<\/li>\n<li>Rechargeable Li-ion battery<\/li>\n<li>ISO\/IEC 17025 accredited calibration certificate included<\/li>\n<\/ul>\n<h2>Professional Temperature Calibration<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> is designed primarily as a multifunction temperature calibrator.<\/p>\n<p>Instead of requiring separate instruments for thermocouple simulation, RTD simulation and electrical signal calibration, the ADT221A combines these functions in one portable device.<\/p>\n<p>This makes it suitable for calibrating and testing:<\/p>\n<ul>\n<li>Temperature transmitters<\/li>\n<li>Temperature indicators<\/li>\n<li>Process controllers<\/li>\n<li>Data acquisition systems<\/li>\n<li>Temperature recorders<\/li>\n<li>PLC temperature inputs<\/li>\n<li>RTD measuring instruments<\/li>\n<li>Thermocouple measuring instruments<\/li>\n<\/ul>\n<p>Both sensor simulation and measurement are available, providing flexibility for a wide range of temperature calibration procedures.<\/p>\n<h2>RTD Measurement and Simulation<\/h2>\n<p>Resistance temperature detectors are widely used for accurate industrial temperature measurement.<\/p>\n<p>The <strong>Additel ADT221A<\/strong> supports 11 RTD types.<\/p>\n<p>Supported characteristics include commonly used sensors such as:<\/p>\n<p><strong>Pt100 (385)<\/strong><\/p>\n<p><strong>Pt100 (3916)<\/strong><\/p>\n<p><strong>Pt100 (3926)<\/strong><\/p>\n<p><strong>Pt500 (385)<\/strong><\/p>\n<p><strong>Pt1000 (385)<\/strong><\/p>\n<p>as well as additional platinum, copper and nickel resistance thermometer characteristics.<\/p>\n<p>For the widely used <strong>Pt100 (385)<\/strong> according to IEC 751, the ADT221A covers temperatures from:<\/p>\n<p><strong>-200 \u00b0C to 850 \u00b0C<\/strong><\/p>\n<p>depending on the measurement or simulation function.<\/p>\n<p>This allows the instrument to simulate an RTD electrically and test how a connected transmitter, indicator or controller interprets the corresponding resistance value.<\/p>\n<p>The ADT221A can also measure RTD sensors and resistance signals.<\/p>\n<h2>Pt100 Calibration<\/h2>\n<p>The Pt100 is one of the most important resistance thermometers used in industrial temperature measurement.<\/p>\n<p>For a Pt100 (385), Additel specifies different accuracies depending on temperature and connection method.<\/p>\n<p>For example, within the range from <strong>-200 \u00b0C to 200 \u00b0C<\/strong>, the specified accuracy for Pt100 (385) measurement is as low as:<\/p>\n<p><strong>0.10 \u00b0C in 4-wire measurement<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>0.15 \u00b0C in 2-wire or 3-wire measurement<\/strong>.<\/p>\n<p>The source or simulation specification in this range is:<\/p>\n<p><strong>0.15 \u00b0C<\/strong>.<\/p>\n<p>This makes the ADT221A suitable for precise electrical testing of Pt100-based temperature measurement systems.<\/p>\n<h2>Thermocouple Measurement and Simulation<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> supports measurement and simulation of <strong>13 thermocouple types<\/strong>.<\/p>\n<p>This enables the calibrator to reproduce the millivolt signal corresponding to a defined thermocouple temperature.<\/p>\n<p>The function is particularly useful when calibrating:<\/p>\n<ul>\n<li>Thermocouple transmitters<\/li>\n<li>Digital temperature indicators<\/li>\n<li>Temperature controllers<\/li>\n<li>PLC thermocouple inputs<\/li>\n<li>Data acquisition systems<\/li>\n<li>Temperature recorders<\/li>\n<\/ul>\n<p>Instead of heating a physical thermocouple to a defined temperature, the ADT221A can simulate its electrical output.<\/p>\n<p>This significantly simplifies many electrical temperature calibration procedures.<\/p>\n<h2>Calibrated Cold Junction Compensation<\/h2>\n<p>Cold junction compensation is a critical part of thermocouple measurement.<\/p>\n<p>The <strong>Additel ADT221A<\/strong> incorporates a specially designed cold junction equalizing block with a calibrated PRT element.<\/p>\n<p>The PRT element is installed directly in the cold junction compensation system and can be removed from the calibrator.<\/p>\n<p>This allows the cold junction compensation sensor to be:<\/p>\n<ul>\n<li>Recalibrated<\/li>\n<li>Checked at the ice point<\/li>\n<li>Corrected when required<\/li>\n<\/ul>\n<p>This patented concept provides an important metrological advantage because the cold junction compensation itself can be verified rather than being treated as an inaccessible internal component.<\/p>\n<p>For users performing demanding thermocouple calibration, this provides greater control over an important contribution to measurement uncertainty.<\/p>\n<h2>Electrical Signal Measurement and Source<\/h2>\n<p>The Additel ADT221A is not limited to temperature functions.<\/p>\n<p>It can also measure and source several electrical signals commonly encountered in process instrumentation.<\/p>\n<p>These include:<\/p>\n<ul>\n<li>Millivolt<\/li>\n<li>Voltage<\/li>\n<li>Current<\/li>\n<li>Resistance<\/li>\n<li>Frequency<\/li>\n<li>Pulse<\/li>\n<\/ul>\n<p>This functionality allows the ADT221A to test complete temperature measurement chains rather than only the temperature sensor characteristic.<\/p>\n<p>For example, a technician can simulate a temperature sensor and also evaluate electrical signals associated with the transmitter or control system.<\/p>\n<h2>Current Measurement and Source<\/h2>\n<p>Current measurement and source functions make the <strong>Additel ADT221A<\/strong> suitable for working with process transmitters and other devices using standardized electrical current signals.<\/p>\n<p>A temperature transmitter may convert the signal from an RTD or thermocouple into a conventional <strong>4\u201320 mA<\/strong> process signal.<\/p>\n<p>The ADT221A can support testing of these electrical signals within the calibration process.<\/p>\n<p>This makes it possible to evaluate both the temperature input side and the electrical output side of a transmitter using one instrument.<\/p>\n<h2>24 V Loop Power<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> provides a:<\/p>\n<p><strong>24 V loop power supply<\/strong>.<\/p>\n<p>This allows suitable two-wire transmitters to be powered during testing without requiring a separate external loop supply.<\/p>\n<p>For mobile calibration work, reducing the number of additional power supplies and instruments can significantly simplify the test setup.<\/p>\n<h2>Frequency and Pulse Functions<\/h2>\n<p>The ADT221A also supports frequency and pulse measurement and generation.<\/p>\n<p>These functions extend the calibrator beyond conventional temperature applications.<\/p>\n<p>Additel specifically includes a pulse frequency output for the calibration of:<\/p>\n<p><strong>flow totalizers<\/strong>.<\/p>\n<p>This provides additional versatility for process calibration departments that work with both temperature and frequency-based instrumentation.<\/p>\n<h2>Automatic Switch Test<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> includes an automatic switch test function.<\/p>\n<p>This can be useful when testing devices such as:<\/p>\n<ul>\n<li>Temperature switches<\/li>\n<li>Thermostats<\/li>\n<li>Limit switches<\/li>\n<li>Process alarm contacts<\/li>\n<\/ul>\n<p>The function helps determine switching behavior as the simulated process signal changes.<\/p>\n<p>This allows temperature switching devices to be tested using the same instrument used for RTD and thermocouple simulation.<\/p>\n<h2>Simultaneous Dual Reading<\/h2>\n<p>The Additel ADT221A supports simultaneous dual readings.<\/p>\n<p>This allows two relevant values to be displayed during calibration tasks and can make testing complex process devices more convenient.<\/p>\n<p>For example, technicians can work with an input and output signal without repeatedly switching between separate measurement displays.<\/p>\n<p>This is especially useful for transmitter calibration.<\/p>\n<h2>Documenting Calibration Functions<\/h2>\n<p>An important difference between the <strong>Additel ADT221A<\/strong> and simpler temperature or process calibrators is its integrated documentation functionality.<\/p>\n<p>The instrument allows users to:<\/p>\n<ul>\n<li>Manage device-under-test information<\/li>\n<li>Create calibration tasks<\/li>\n<li>Set up automated calibration procedures<\/li>\n<li>Execute tests<\/li>\n<li>Calculate errors<\/li>\n<li>Display results<\/li>\n<li>Store calibration results<\/li>\n<li>Identify out-of-tolerance points<\/li>\n<\/ul>\n<p>This makes the ADT221A particularly suitable for structured calibration workflows.<\/p>\n<h2>As-Found and As-Left Results<\/h2>\n<p>The documenting functions include:<\/p>\n<p><strong>As-found<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>As-left<\/strong><\/p>\n<p>data.<\/p>\n<p>As-found results document the condition of the device before adjustment or repair.<\/p>\n<p>As-left results document its condition after calibration, adjustment or service.<\/p>\n<p>This information is important in quality-controlled calibration environments because it provides evidence of how the device performed before and after intervention.<\/p>\n<p>The ADT221A can store these results directly.<\/p>\n<h2>Automated Calibration Procedures<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> can perform automated calibration procedures.<\/p>\n<p>Instead of manually selecting every test point, the operator can prepare a calibration task and allow the instrument to work through the required procedure.<\/p>\n<p>The calibrator can calculate errors and identify points that fall outside defined tolerances.<\/p>\n<p>This reduces repetitive manual work and helps standardize recurring calibration procedures.<\/p>\n<h2>Calibration Data Management<\/h2>\n<p>Stored tasks and results can be transferred and managed using compatible Additel software.<\/p>\n<p>Additel identifies <strong>Additel\/Land<\/strong> and <strong>Additel\/Cal<\/strong> as software solutions for working with stored calibration tasks and data.<\/p>\n<p>This allows the ADT221A to form part of a more structured calibration and documentation workflow rather than functioning only as a standalone signal source.<\/p>\n<h2>Smartphone-Like User Interface<\/h2>\n<p>Despite the large number of functions, Additel designed the ADT221A with a smartphone-like menu and user interface.<\/p>\n<p>The objective is to provide straightforward access to the different measurement, source and documentation functions.<\/p>\n<p>The instrument uses a <strong>3.5-inch TFT color display<\/strong>.<\/p>\n<p>Its compact housing is designed for one-handed operation, making the calibrator suitable for technicians working directly at industrial installations.<\/p>\n<h2>Compact and Lightweight<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> measures approximately:<\/p>\n<p><strong>100 \u00d7 192 \u00d7 52 mm<\/strong><\/p>\n<p>and weighs approximately:<\/p>\n<p><strong>0.7 kg<\/strong>.<\/p>\n<p>The compact design allows the calibrator to be transported easily between calibration locations.<\/p>\n<p>This makes it suitable for both:<\/p>\n<ul>\n<li>Calibration laboratories<\/li>\n<li>Field calibration<\/li>\n<li>Industrial maintenance<\/li>\n<li>Commissioning<\/li>\n<li>Service applications<\/li>\n<\/ul>\n<p>The broad functionality means technicians can replace several individual electrical and temperature simulation devices with one portable calibrator.<\/p>\n<h2>Rechargeable Battery<\/h2>\n<p>The ADT221A uses a rechargeable Li-ion battery.<\/p>\n<p>Additel specifies up to approximately:<\/p>\n<p><strong>15 hours of uninterrupted operation<\/strong><\/p>\n<p>under suitable operating conditions.<\/p>\n<p>Battery operating time is reduced when the 24 V loop supply is used.<\/p>\n<p>The rechargeable battery is replaceable, which is useful for instruments intended for long-term professional use.<\/p>\n<h2>Protection Against Connection Errors<\/h2>\n<p>The Additel ADT221A incorporates protection against common electrical connection errors.<\/p>\n<p>According to Additel, application of up to <strong>30 V<\/strong> to any two sockets and up to <strong>1 A<\/strong> to the current sockets will not damage the calibrator within the specified protection conditions.<\/p>\n<p>Once the incorrect voltage or current is removed, the instrument can return to normal operation.<\/p>\n<p>This protection is particularly valuable for field service, where incorrect connections can occur when working on unfamiliar process systems.<\/p>\n<h2>Additel ADT221A Compared with ADT222A<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> and ADT222A share many temperature, electrical and documentation functions.<\/p>\n<p>The major difference is pressure capability.<\/p>\n<p>The ADT221A is primarily a:<\/p>\n<p><strong>Multifunction Temperature Calibrator<\/strong><\/p>\n<p>while the ADT222A adds support for Additel intelligent digital pressure modules.<\/p>\n<p>The ADT222A can therefore measure and source pressure using compatible Additel pressure modules, whereas the ADT221A focuses on temperature and electrical calibration.<\/p>\n<p>For users who primarily calibrate RTDs, thermocouples and temperature transmitters, the ADT221A provides the required functionality without the additional pressure module capability.<\/p>\n<h2>Additel ADT221A Compared with ADT223A<\/h2>\n<p>The ADT223A adds further functionality to the 22XA platform.<\/p>\n<p>In addition to pressure module support, the ADT223A includes:<\/p>\n<p><strong>HART communication capability<\/strong>.<\/p>\n<p>The <strong>ADT221A does not include HART communication<\/strong>.<\/p>\n<p>This distinction is important when selecting a calibrator.<\/p>\n<p>The ADT221A is therefore particularly suitable when the primary requirement is temperature and electrical calibration with documentation, while the ADT223A is intended for applications requiring pressure and HART functionality as well.<\/p>\n<h2>ISO\/IEC 17025 Accredited Calibration<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> is supplied with an:<\/p>\n<p><strong>ISO\/IEC 17025 accredited calibration certificate<\/strong>.<\/p>\n<p>This supports metrological traceability and provides documented calibration information for the instrument.<\/p>\n<p>Regular calibration remains important for maintaining confidence in the performance of temperature and electrical calibration equipment.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional calibration services for temperature, electrical and other measurement quantities.<\/p>\n<p>For further information about professional calibration and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Additel ADT221A<\/th>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Multifunction Temperature Calibrator<\/td>\n<\/tr>\n<tr>\n<td>RTD measurement<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>RTD simulation<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>RTD types<\/td>\n<td>11<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple measurement<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple simulation<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple types<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<td>Pt100 (385) range<\/td>\n<td>-200 \u00b0C to 850 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Best Pt100 4-wire accuracy<\/td>\n<td>0.10 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>mV measure \/ source<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Voltage measure \/ source<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Current measure \/ source<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Resistance measure \/ source<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Frequency measure \/ source<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Pulse measure \/ source<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>24 V loop power<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Automatic switch test<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Dual reading<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Documenting functions<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Automated procedures<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>As-found \/ as-left<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Cold junction compensation<\/td>\n<td>Calibrated removable PRT<\/td>\n<\/tr>\n<tr>\n<td>Pressure module support<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>HART communication<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>3.5-inch TFT color<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Approx. 100 \u00d7 192 \u00d7 52 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 0.7 kg<\/td>\n<\/tr>\n<tr>\n<td>Battery<\/td>\n<td>Rechargeable Li-ion<\/td>\n<\/tr>\n<tr>\n<td>Battery operation<\/td>\n<td>Up to approx. 15 hours<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>ISO\/IEC 17025 accredited certificate<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why Choose the Additel ADT221A?<\/h2>\n<p>The <strong>Additel ADT221A<\/strong> combines comprehensive temperature simulation and measurement with electrical signal generation, documentation and automated calibration procedures in a compact handheld instrument.<\/p>\n<p>Support for <strong>13 thermocouple types and 11 RTD types<\/strong> makes it suitable for a wide range of industrial temperature measurement systems.<\/p>\n<p>The calibrator can measure and source mV, V, mA, resistance, frequency and pulses, allowing technicians to test more than just the temperature sensor input.<\/p>\n<p>Its calibrated cold junction compensation system is particularly valuable for thermocouple applications. The internal PRT used for cold junction compensation can be removed, recalibrated and corrected at the ice point, providing greater control over this important part of the thermocouple measurement chain.<\/p>\n<p>Integrated documentation allows calibration tasks to be created and executed directly on the instrument. Results can be stored, errors calculated and out-of-tolerance points identified. As-found and as-left functions support structured quality-controlled calibration procedures.<\/p>\n<p>Despite this extensive functionality, the ADT221A weighs only approximately <strong>0.7 kg<\/strong> and is designed for convenient one-handed operation.<\/p>\n<p>The result is a powerful portable calibrator for temperature calibration laboratories, industrial maintenance departments and field service technicians.<\/p>\n<p>At <strong>europascal<\/strong>, we provide professional solutions for temperature measurement and calibration technology and can assist you in selecting the appropriate Additel equipment for your application.<\/p>\n<p>For professional calibration and metrological traceability of the Additel ADT221A and other temperature and electrical measuring instruments, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/additel\/\">Discover more Additel products at europascal.<\/a><\/p>\n<p>Manufacturer information about the <strong>Additel ADT221A<\/strong> is available on the <a href=\"https:\/\/www.additel.com\/\" target=\"_blank\" rel=\"noopener\">official Additel website<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Additel ADT221A<\/strong> is a versatile multifunction temperature calibrator for measuring, sourcing and simulating <strong>RTDs, thermocouples and electrical signals<\/strong>. It supports <strong>13 thermocouple types and 11 RTD types<\/strong> and provides mV, V, mA, resistance, frequency, pulse and 24 V loop power functions. Integrated documentation, automated calibration procedures and a recalibratable cold junction compensation sensor make the ADT221A ideal for professional temperature calibration.<\/p>\n","protected":false},"featured_media":6551,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[90],"product_cat":[1211],"product_tag":[4744,4973,4974,4975,4976,3922,3925,4593,4761,3995,4977,4978,4752,3999,4002,4003,4979],"class_list":["post-6550","product","type-product","status-publish","has-post-thumbnail","product_brand-additel","product_cat-obsolete","product_tag-4-bis-20-ma-kalibrator","product_tag-additel-221a","product_tag-additel-adt-221a","product_tag-adt-221a","product_tag-dokumentierender-kalibrator","product_tag-kalibrierlabor","product_tag-multifunktionskalibrator","product_tag-prozesskalibrator","product_tag-prozessmesstechnik","product_tag-pt100-kalibrieren","product_tag-pt100-simulieren","product_tag-pt1000-simulieren","product_tag-rtd-kalibrator","product_tag-temperaturkalibrator","product_tag-temperaturtransmitter-kalibrieren","product_tag-thermoelement-kalibrieren","product_tag-thermoelement-simulieren","pa_bauart-handgeraet","pa_hart-kommunikation-nein","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6550","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6551"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6550"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6550"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6550"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6550"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}