{"id":6703,"date":"2026-07-17T15:58:34","date_gmt":"2026-07-17T15:58:34","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-p5515\/"},"modified":"2026-10-05T10:49:11","modified_gmt":"2026-10-05T10:49:11","slug":"fluke-p5515","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-p5515\/","title":{"rendered":"Fluke P5515 Powerful Hydraulic Comparison Test Pump"},"content":{"rendered":"<p><strong>Fluke P5515<\/strong> is a powerful hydraulic comparison test pump designed for professional pressure calibration up to <strong>20,000 psi \/ 1,400 bar<\/strong>. It provides a reliable and convenient method for generating high hydraulic pressures when checking pressure gauges, digital pressure indicators, pressure transmitters and other pressure measuring instruments against a suitable reference standard.<\/p>\n<p>Designed for laboratory and field calibration applications, the Fluke P5515 combines a built-in hand pump for system priming and large-volume applications with a high-quality screw press for precise pressure adjustment. This combination allows the operator to fill the hydraulic system efficiently, generate pressure and then make fine adjustments at the required calibration point.<\/p>\n<p>The P5515 can operate with a wide range of compatible hydraulic fluids. A transparent acrylic reservoir allows the operator to visually monitor both the fluid level and fluid condition. Different sealing configurations are available to accommodate different pressure media.<\/p>\n<p>Two test connections allow a reference pressure instrument and the device under test to be connected to the same hydraulic pressure system. Fluke supplies test port adapter sets for common NPT or BSP thread sizes, making the P5515 suitable for a broad range of pressure calibration applications.<\/p>\n<p>The <strong>Fluke P5515<\/strong> is a pressure generator and comparator. It does not independently measure the reference pressure. For calibration, it is combined with a suitable reference pressure gauge, pressure transducer or other pressure standard.<\/p>\n<p>At <strong>europascal<\/strong>, the Fluke P5515 can be combined with suitable reference pressure instruments, adapters and calibration equipment to create a complete high-pressure calibration solution. For professional calibration and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The <strong>Fluke P5515<\/strong> combines high-pressure capability with precise manual pressure control and flexible hydraulic operation.<\/p>\n<p>Key benefits include:<\/p>\n<ul>\n<li>Hydraulic comparison test pump<\/li>\n<li>Pressure generation up to 20,000 psi<\/li>\n<li>Maximum pressure of 1,400 bar<\/li>\n<li>Maximum pressure of 140 MPa<\/li>\n<li>Built-in hand pump<\/li>\n<li>Suitable for system priming<\/li>\n<li>Suitable for large-volume applications<\/li>\n<li>High-quality screw press<\/li>\n<li>Precise pressure adjustment<\/li>\n<li>Wide choice of compatible hydraulic fluids<\/li>\n<li>Transparent acrylic fluid reservoir<\/li>\n<li>Visual monitoring of fluid level<\/li>\n<li>Visual monitoring of fluid quality<\/li>\n<li>Two test port adapter sets<\/li>\n<li>NPT adapters available<\/li>\n<li>BSP adapters available<\/li>\n<li>Portable design<\/li>\n<li>Suitable for reference pressure gauges<\/li>\n<li>Suitable for digital pressure references<\/li>\n<li>Pressure gauge calibration<\/li>\n<li>Pressure transmitter calibration<\/li>\n<li>Pressure transducer calibration<\/li>\n<li>High-pressure comparison calibration<\/li>\n<li>Laboratory and field applications<\/li>\n<\/ul>\n<h2>Pressure Generation up to 1,400 bar<\/h2>\n<p>The <strong>Fluke P5515<\/strong> provides a pressure range of:<\/p>\n<p><strong>0 to 20,000 psi<\/strong><\/p>\n<p>or:<\/p>\n<p><strong>0 to 1,400 bar \/ 140 MPa<\/strong>.<\/p>\n<p>This high maximum pressure makes the P5515 suitable for demanding hydraulic pressure calibration applications where conventional hand pumps may no longer provide sufficient pressure.<\/p>\n<p>The broad pressure range allows the P5515 to be used with many industrial high-pressure instruments.<\/p>\n<h2>Hydraulic Comparison Calibration<\/h2>\n<p>The P5515 is designed for:<\/p>\n<p><strong>hydraulic comparison calibration<\/strong>.<\/p>\n<p>A typical calibration system consists of:<\/p>\n<p><strong>Fluke P5515 + Reference Pressure Instrument + Device Under Test<\/strong><\/p>\n<p>The P5515 generates the hydraulic pressure.<\/p>\n<p>The reference instrument measures the actual applied pressure.<\/p>\n<p>The device under test is exposed to the same pressure.<\/p>\n<p>The indication of the DUT can then be compared directly with the value measured by the reference instrument.<\/p>\n<h2>Built-In Hand Pump<\/h2>\n<p>The <strong>Fluke P5515<\/strong> incorporates a hand pump.<\/p>\n<p>The integrated hand pump is particularly useful for:<\/p>\n<ul>\n<li>Filling the pressure system<\/li>\n<li>Priming the hydraulic circuit<\/li>\n<li>Moving larger volumes of fluid<\/li>\n<li>Quickly approaching the required pressure range<\/li>\n<\/ul>\n<p>After the system has been primed, the screw press can be used for further pressure generation and fine adjustment.<\/p>\n<p>This combination provides significantly more convenient operation than relying exclusively on a fine adjustment screw.<\/p>\n<h2>High-Quality Screw Press<\/h2>\n<p>Precise pressure adjustment is essential during comparison calibration.<\/p>\n<p>The P5515 therefore incorporates a:<\/p>\n<p><strong>high-quality screw press<\/strong>.<\/p>\n<p>The screw press allows the operator to make controlled changes to the internal hydraulic volume.<\/p>\n<p>This provides precise pressure adjustment when approaching a defined calibration point.<\/p>\n<p>The screw press displacement is approximately:<\/p>\n<p><strong>5.5 cm\u00b3<\/strong>.<\/p>\n<h2>Fine Pressure Control<\/h2>\n<p>Once the approximate pressure has been generated using the hand pump, the screw press can be used for fine pressure control.<\/p>\n<p>This is particularly useful when calibrating high-resolution digital pressure gauges or pressure transmitters.<\/p>\n<p>The operator can approach the desired calibration point carefully and wait for the system to stabilize before recording the reference and DUT readings.<\/p>\n<h2>Large-Volume Applications<\/h2>\n<p>The integrated hand pump has a displacement of approximately:<\/p>\n<p><strong>4.7 cm\u00b3 per stroke<\/strong>.<\/p>\n<p>This makes it useful when the connected pressure system has a comparatively large internal volume.<\/p>\n<p>Instead of using the fine screw press to fill the entire system, the hand pump can rapidly introduce hydraulic fluid before precise pressure adjustment begins.<\/p>\n<h2>150 cm\u00b3 Reservoir<\/h2>\n<p>The <strong>Fluke P5515<\/strong> incorporates a hydraulic fluid reservoir with a volume of:<\/p>\n<p><strong>150 cm\u00b3<\/strong>.<\/p>\n<p>The reservoir provides sufficient fluid capacity for typical high-pressure comparison calibration applications.<\/p>\n<h2>Transparent Acrylic Reservoir<\/h2>\n<p>An important practical feature of the P5515 is its:<\/p>\n<p><strong>transparent acrylic reservoir<\/strong>.<\/p>\n<p>The transparent construction allows the operator to visually check the hydraulic fluid.<\/p>\n<p>This makes it easy to monitor:<\/p>\n<ul>\n<li>Fluid level<\/li>\n<li>Fluid condition<\/li>\n<li>Possible contamination<\/li>\n<\/ul>\n<p>The condition of the pressure medium is important because contamination can affect the pressure system, seals and the instruments connected to the comparator.<\/p>\n<h2>Wide Range of Hydraulic Fluids<\/h2>\n<p>The <strong>Fluke P5515<\/strong> is designed for operation with a wide range of compatible fluids.<\/p>\n<p>This provides greater flexibility when calibrating instruments that require particular pressure media.<\/p>\n<p>The compatibility of the selected fluid with the P5515 seals and the device under test must always be checked before use.<\/p>\n<h2>Viton Seal Version<\/h2>\n<p>One available version is the:<\/p>\n<p><strong>P5515-140M<\/strong>.<\/p>\n<p>This configuration uses Viton seals and provides the full pressure range up to:<\/p>\n<p><strong>20,000 psi \/ 1,400 bar \/ 140 MPa<\/strong>.<\/p>\n<p>It is the standard high-pressure configuration for many hydraulic calibration applications.<\/p>\n<h2>Ethylene Propylene Seal Version<\/h2>\n<p>Fluke also offers the:<\/p>\n<p><strong>P5515-140M-EP<\/strong>.<\/p>\n<p>This version uses:<\/p>\n<p><strong>ethylene propylene seals<\/strong>.<\/p>\n<p>It also provides pressure generation up to:<\/p>\n<p><strong>20,000 psi \/ 140 MPa<\/strong>.<\/p>\n<p>The different seal configuration allows the pressure comparator to be adapted to different hydraulic media and application requirements.<\/p>\n<h2>Test Port Adapters<\/h2>\n<p>The <strong>Fluke P5515<\/strong> is supplied with two sets of test port adapters.<\/p>\n<p>Depending on the selected version, adapter sets are available for common:<\/p>\n<p><strong>NPT<\/strong><\/p>\n<p>or:<\/p>\n<p><strong>BSP<\/strong><\/p>\n<p>threads.<\/p>\n<p>The available sizes include:<\/p>\n<ul>\n<li>1\/8 inch<\/li>\n<li>1\/4 inch<\/li>\n<li>3\/8 inch<\/li>\n<li>1\/2 inch<\/li>\n<\/ul>\n<p>This provides flexible connection of reference instruments and devices under test.<\/p>\n<h2>Reference and DUT Connection<\/h2>\n<p>For comparison calibration, two instruments are normally connected to the pressure system.<\/p>\n<p>One connection is used for the:<\/p>\n<p><strong>Reference Pressure Instrument<\/strong><\/p>\n<p>and the other for the:<\/p>\n<p><strong>Device Under Test<\/strong>.<\/p>\n<p>Both instruments are exposed to the same hydraulic pressure.<\/p>\n<p>This simple comparison principle allows pressure gauges, transmitters and transducers to be calibrated efficiently.<\/p>\n<h2>Pressure Gauge Calibration<\/h2>\n<p>The <strong>Fluke P5515<\/strong> is particularly suitable for high-pressure gauge calibration.<\/p>\n<p>A precision reference pressure gauge is connected to one test port and the pressure gauge under test to the other.<\/p>\n<p>The operator then generates defined pressure points.<\/p>\n<p>A typical calibration sequence may include increasing and decreasing pressure points across the DUT measurement range.<\/p>\n<p>The difference between the reference pressure and the DUT indication can then be determined at each point.<\/p>\n<h2>Digital Pressure Gauge Calibration<\/h2>\n<p>Digital pressure gauges can be calibrated using the same comparison method.<\/p>\n<p>A high-accuracy digital reference gauge can be combined with the P5515 to create a complete manual hydraulic calibration system.<\/p>\n<p>The fine adjustment capability of the screw press is especially useful when approaching exact calibration points for high-resolution digital gauges.<\/p>\n<h2>Pressure Transmitter Calibration<\/h2>\n<p>The <strong>Fluke P5515<\/strong> can also be used for pressure transmitter calibration.<\/p>\n<p>A typical configuration consists of:<\/p>\n<p><strong>P5515 + Reference Pressure Instrument + Pressure Transmitter + Electrical Calibrator<\/strong><\/p>\n<p>The P5515 generates the hydraulic pressure.<\/p>\n<p>The reference instrument determines the actual applied pressure.<\/p>\n<p>An electrical calibrator measures the transmitter output.<\/p>\n<p>For many industrial pressure transmitters, the output signal is:<\/p>\n<p><strong>4 to 20 mA<\/strong>.<\/p>\n<p>This allows the complete pressure-to-current characteristic to be evaluated.<\/p>\n<h2>Pressure Transducer Calibration<\/h2>\n<p>High-pressure transducers and pressure sensors can also be tested with the P5515.<\/p>\n<p>The transducer is exposed to the same hydraulic pressure as the reference instrument.<\/p>\n<p>Its electrical output can then be evaluated at defined pressure points.<\/p>\n<h2>Use with the Fluke 2700G<\/h2>\n<p>Fluke offers configurations that combine the P5515 with reference pressure gauges from the:<\/p>\n<p><strong>Fluke 2700G Series<\/strong>.<\/p>\n<p>This creates a convenient hydraulic pressure calibration system in which the P5515 generates the pressure and the 2700G provides the reference measurement.<\/p>\n<p>Configurations with one or multiple 2700G reference gauges are available.<\/p>\n<h2>P5515-2700G-1<\/h2>\n<p>The:<\/p>\n<p><strong>P5515-2700G-1<\/strong><\/p>\n<p>configuration combines the P5515 hydraulic comparator with one 2700G reference pressure gauge.<\/p>\n<p>This configuration is designed for pressure calibration up to:<\/p>\n<p><strong>70 MPa \/ 10,000 psi<\/strong>.<\/p>\n<p>It provides a compact solution for users who require both pressure generation and reference pressure measurement.<\/p>\n<h2>P5515-2700G-3<\/h2>\n<p>The:<\/p>\n<p><strong>P5515-2700G-3<\/strong><\/p>\n<p>configuration combines the P5515 with three 2700G reference gauges covering different pressure ranges.<\/p>\n<p>Using several reference ranges can improve the suitability of the system for devices under test with different maximum pressures.<\/p>\n<h2>Accredited Calibration Configurations<\/h2>\n<p>Fluke also lists selected P5515 and 2700G combinations with accredited calibration.<\/p>\n<p>These configurations can be useful when a complete pressure calibration solution with documented metrological traceability is required.<\/p>\n<p>The exact calibration scope and certificate should always be verified for the selected configuration.<\/p>\n<h2>Pressure Generator, Not Reference Standard<\/h2>\n<p>An important distinction must be made when using the <strong>Fluke P5515<\/strong>.<\/p>\n<p>The P5515 itself is:<\/p>\n<p><strong>a hydraulic pressure generator and comparator<\/strong>.<\/p>\n<p>It is not the pressure reference.<\/p>\n<p>The metrological reference is provided by the connected:<\/p>\n<ul>\n<li>Reference pressure gauge<\/li>\n<li>Reference pressure transducer<\/li>\n<li>Pressure monitor<\/li>\n<li>Other suitable pressure standard<\/li>\n<\/ul>\n<p>The measurement uncertainty of the calibration therefore depends primarily on the reference instrument, calibration method and complete measurement setup.<\/p>\n<h2>Portable High-Pressure Solution<\/h2>\n<p>Despite its high pressure capability, the P5515 is designed as a portable comparison test pump.<\/p>\n<p>The instrument weighs approximately:<\/p>\n<p><strong>16 kg \/ 36 lb<\/strong>.<\/p>\n<p>Its dimensions are approximately:<\/p>\n<p><strong>440 \u00d7 300 \u00d7 215 mm<\/strong>.<\/p>\n<p>This allows the comparator to be transported when high-pressure calibration is required outside a permanent laboratory installation.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Fluke P5515<\/th>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Hydraulic Comparison Test Pump<\/td>\n<\/tr>\n<tr>\n<td>Pressure range<\/td>\n<td>0 to 20,000 psi<\/td>\n<\/tr>\n<tr>\n<td>Maximum pressure<\/td>\n<td>1,400 bar \/ 140 MPa<\/td>\n<\/tr>\n<tr>\n<td>Pressure generation<\/td>\n<td>Manual hydraulic<\/td>\n<\/tr>\n<tr>\n<td>Hand pump<\/td>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<td>Fine adjustment<\/td>\n<td>Screw press<\/td>\n<\/tr>\n<tr>\n<td>Reservoir<\/td>\n<td>Transparent acrylic<\/td>\n<\/tr>\n<tr>\n<td>Reservoir volume<\/td>\n<td>150 cm\u00b3<\/td>\n<\/tr>\n<tr>\n<td>Screw press displacement<\/td>\n<td>5.5 cm\u00b3<\/td>\n<\/tr>\n<tr>\n<td>Hand pump displacement<\/td>\n<td>4.7 cm\u00b3 per stroke<\/td>\n<\/tr>\n<tr>\n<td>Test port adapters<\/td>\n<td>2 sets<\/td>\n<\/tr>\n<tr>\n<td>Adapter sizes<\/td>\n<td>1\/8, 1\/4, 3\/8 and 1\/2 inch<\/td>\n<\/tr>\n<tr>\n<td>Thread options<\/td>\n<td>NPT or BSP<\/td>\n<\/tr>\n<tr>\n<td>Standard seal option<\/td>\n<td>Viton<\/td>\n<\/tr>\n<tr>\n<td>Alternative seals<\/td>\n<td>Ethylene propylene<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>440 \u00d7 300 \u00d7 215 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 16 kg<\/td>\n<\/tr>\n<tr>\n<td>Portable<\/td>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>P5515 vs. P5514<\/h2>\n<p>The <strong>Fluke P5515<\/strong> is designed for substantially higher pressures than the P5514 hydraulic comparison test pump.<\/p>\n<p>The P5515 reaches:<\/p>\n<p><strong>20,000 psi \/ 1,400 bar<\/strong>.<\/p>\n<p>The P5514 series is intended for hydraulic pressure calibration up to approximately:<\/p>\n<p><strong>10,000 psi \/ 700 bar<\/strong>.<\/p>\n<p>The P5515 is therefore the more appropriate choice when calibration requirements extend above 700 bar.<\/p>\n<h2>P5515 vs. P5513<\/h2>\n<p>The P5515 should also be distinguished from the pneumatic P5513.<\/p>\n<p>The:<\/p>\n<p><strong>P5513<\/strong><\/p>\n<p>uses pneumatic pressure and reaches approximately:<\/p>\n<p><strong>3,000 psi \/ 200 bar<\/strong>.<\/p>\n<p>The:<\/p>\n<p><strong>P5515<\/strong><\/p>\n<p>uses hydraulic pressure and reaches:<\/p>\n<p><strong>20,000 psi \/ 1,400 bar<\/strong>.<\/p>\n<p>The selection therefore depends on both the required maximum pressure and the pressure medium that is compatible with the device under test.<\/p>\n<h2>Typical Applications<\/h2>\n<p>The <strong>Fluke P5515<\/strong> is suitable for:<\/p>\n<ul>\n<li>Hydraulic pressure calibration<\/li>\n<li>High-pressure calibration<\/li>\n<li>Pressure gauge calibration<\/li>\n<li>Digital pressure gauge calibration<\/li>\n<li>Pressure transmitter calibration<\/li>\n<li>Pressure transducer calibration<\/li>\n<li>Pressure sensor calibration<\/li>\n<li>Comparison calibration<\/li>\n<li>Reference gauge comparison<\/li>\n<li>Laboratory calibration<\/li>\n<li>Field calibration<\/li>\n<li>Industrial maintenance<\/li>\n<li>Process instrumentation<\/li>\n<li>Quality assurance<\/li>\n<li>Production testing<\/li>\n<li>Research and development<\/li>\n<li>Pressure metrology<\/li>\n<\/ul>\n<h2>Why Choose the Fluke P5515?<\/h2>\n<p>The <strong>Fluke P5515<\/strong> provides a practical solution for generating and precisely adjusting hydraulic pressures up to <strong>20,000 psi \/ 1,400 bar<\/strong>.<\/p>\n<p>Its integrated hand pump allows rapid system priming and is particularly useful when larger hydraulic volumes must be filled. Once the required pressure region has been reached, the high-quality screw press provides the fine adjustment necessary for precise comparison calibration.<\/p>\n<p>A transparent 150 cm\u00b3 acrylic reservoir makes it easy to monitor both the level and condition of the hydraulic fluid.<\/p>\n<p>The availability of different seal configurations and compatibility with a variety of fluids provide additional flexibility for different pressure calibration applications.<\/p>\n<p>Adapter sets for common NPT or BSP thread sizes simplify the connection of reference pressure instruments and devices under test.<\/p>\n<p>The P5515 can be combined with precision reference instruments such as Fluke 2700G reference pressure gauges to create a complete manual hydraulic pressure calibration system.<\/p>\n<p>At <strong>europascal<\/strong>, the Fluke P5515 can be combined with suitable pressure references, adapters and calibration accessories for professional laboratory and field applications.<\/p>\n<p>For professional calibration and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/en\/?s=Fluke+Calibration&amp;post_type=product\">Further products from Fluke can be found here.<\/a><\/p>\n<p><a href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/pressure-calibrators\/fluke-calibration-p5515\" target=\"_blank\" rel=\"noopener\">Manufacturer information about the Fluke P5515 can be found on the official Fluke website.<\/a><\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-P5515-Comparison-Test-Pump.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke P5515<\/strong> is a powerful hydraulic comparison test pump for professional pressure calibration up to <strong>20,000 psi \/ 1,400 bar<\/strong>. An integrated hand pump provides fast system priming, while the high-quality screw press enables precise pressure adjustment. A transparent 150 cm\u00b3 reservoir and flexible NPT or BSP adapter options make the P5515 ideal for laboratory and field calibration.<\/p>\n","protected":false},"featured_media":6704,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[49,45],"product_tag":[5552,5553,5465,4201,4202,4203,5041,5554,5555,5556,5557,4313,4315,5558,5071,3922,4206,4578,5559,4402],"class_list":["post-6703","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-pressure-generator-pressure-control-unit","product_cat-pressure","product_tag-1400-bar-druckpumpe","product_tag-20000-psi-druckpumpe","product_tag-digitalmanometer-kalibrieren","product_tag-druckkalibrator","product_tag-drucksensor-kalibrieren","product_tag-drucktransmitter-kalibrieren","product_tag-druckvergleichspumpe","product_tag-fluke-2700g","product_tag-fluke-calibration-p5515","product_tag-fluke-p5515","product_tag-handpumpe","product_tag-hochdruckkalibrierung","product_tag-hydraulische-druckkalibrierung","product_tag-hydraulische-vergleichstestpumpe","product_tag-hydraulischer-druckerzeuger","product_tag-kalibrierlabor","product_tag-manometer-kalibrieren","product_tag-referenzmanometer","product_tag-schraubenpresse","product_tag-vergleichskalibrierung","pa_druckbereich--140-bar","pa_medium-oel","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6703","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6704"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6703"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6703"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6703"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6703"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}