{"id":6748,"date":"2026-07-17T15:56:24","date_gmt":"2026-07-17T15:56:24","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-2271a\/"},"modified":"2026-10-07T11:28:34","modified_gmt":"2026-10-07T11:28:34","slug":"fluke-calibration-2271a","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-2271a\/","title":{"rendered":"Fluke Calibration 2271A Modular Pressure Calibrator"},"content":{"rendered":"<p><strong>Fluke Calibration 2271A<\/strong> is a modular automated pressure calibrator designed for professional calibration of pressure gauges, pressure transmitters, pressure switches and pressure sensors. With a pressure measurement range from <strong>-100 kPa to 20 MPa (-15 psi to 3,000 psi)<\/strong>, interchangeable PM200 and PM500 pressure measurement modules, integrated electrical measurement functions and automated pressure control, the 2271A provides a complete solution for industrial and laboratory pressure calibration. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>The modular architecture is one of the key strengths of the Fluke Calibration 2271A. Two pressure measurement modules can be installed in the chassis, allowing different pressure ranges and accuracy classes to be combined in one system. As calibration requirements change, modules can be exchanged or additional ranges purchased without replacing the complete controller. PM200 modules are designed for economical industrial calibration with specifications down to <strong>0.02% FS<\/strong>, while PM500 modules provide measurement uncertainty down to <strong>0.01% of reading<\/strong> over significant portions of their ranges. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>The 2271A also integrates an Electrical Measurement Module, or EMM, with mA and DC voltage measurement, <strong>24 V DC loop power and HART communication<\/strong>. This allows pressure transmitters to be connected, powered, controlled and calibrated directly with the same system. Fully automated closed-loop calibration of 4\u201320 mA smart pressure transmitters can therefore be performed without requiring a separate digital multimeter, loop supply or external HART resistor. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>For calibration laboratories looking to improve throughput, the 2271A can automate pressure generation, stabilization, electrical measurement and evaluation. It can also be controlled by Fluke Calibration COMPASS for Pressure software or integrated into custom automated calibration systems through Ethernet, RS232 and USB interfaces. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>europascal supports professional users in selecting suitable pressure measurement modules, pressure connections and accessories for the 2271A. europascal also operates one of its core accredited calibration capabilities in pressure metrology, covering a very wide range of pressure instruments. For traceable calibration and service, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/?utm_source=chatgpt.com\">europascal Calibration Service<\/a>. europascal is additionally listed by Fluke as a regional service provider for Fluke Calibration pressure and flow products. <a href=\"https:\/\/europascal.de\/en\/our-company\/?utm_source=chatgpt.com\">europascal.de<\/a><\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Automated pneumatic pressure calibrator<\/li>\n<li>Pressure range from -100 kPa to 20 MPa<\/li>\n<li>Equivalent range from -15 psi to 3,000 psi<\/li>\n<li>Modular pressure measurement concept<\/li>\n<li>Two pressure measurement modules can be installed<\/li>\n<li>PM200 pressure measurement modules<\/li>\n<li>PM500 pressure measurement modules<\/li>\n<li>Accuracy classes down to 0.02% FS or 0.01% of reading<\/li>\n<li>Modules can be exchanged as calibration requirements change<\/li>\n<li>Dynamic control precision down to 0.001% of range span<\/li>\n<li>Typical control turndown of 10:1<\/li>\n<li>Low control point down to 1 kPa absolute<\/li>\n<li>Automatic pressure generation and control<\/li>\n<li>Integrated Electrical Measurement Module<\/li>\n<li>DC current measurement<\/li>\n<li>DC voltage measurement<\/li>\n<li>24 V loop power<\/li>\n<li>Integrated HART communication<\/li>\n<li>Built-in 250 \u03a9 HART resistor<\/li>\n<li>Fully automated pressure transmitter calibration<\/li>\n<li>Dual test ports for multiple devices under test<\/li>\n<li>Optional Contamination Prevention System<\/li>\n<li>Ethernet interface<\/li>\n<li>RS232 interface<\/li>\n<li>USB interface<\/li>\n<li>Compatible with COMPASS for Pressure<\/li>\n<li>Suitable for automated calibration laboratories<\/li>\n<li>Suitable for industrial pressure calibration<\/li>\n<li>Professional calibration and service through europascal<\/li>\n<\/ul>\n<p>Fluke positions the 2271A as a complete automated system for calibrating pressure gauges and sensors, with modular measurement capabilities and electrical transmitter calibration functions in one chassis. <a href=\"https:\/\/media.fluke.com\/2c86df71-8b56-4dec-9933-b2d6010c558e_original%20file.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p>The <strong>Fluke Calibration 2271A<\/strong> is designed for laboratories and industrial facilities that need to calibrate a broad variety of pressure instruments with repeatable automated processes.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Calibration of analog pressure gauges<\/li>\n<li>Calibration of digital pressure gauges<\/li>\n<li>Pressure transmitter calibration<\/li>\n<li>HART pressure transmitter calibration<\/li>\n<li>4\u201320 mA pressure transmitter testing<\/li>\n<li>Pressure switch testing<\/li>\n<li>Pressure sensor calibration<\/li>\n<li>Production testing<\/li>\n<li>Quality assurance<\/li>\n<li>Automated calibration stations<\/li>\n<li>Calibration laboratory applications<\/li>\n<li>Industrial maintenance<\/li>\n<li>Research and development<\/li>\n<\/ul>\n<p>The system is particularly attractive for laboratories that are expanding their pressure calibration capabilities because its modular design allows the available workload to grow without replacing the complete pressure controller. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<h2>Pressure Range up to 20 MPa<\/h2>\n<p>The <strong>Fluke Calibration 2271A<\/strong> covers pressure measurement ranges from:<\/p>\n<p><strong>-100 kPa<\/strong><\/p>\n<p>to:<\/p>\n<p><strong>20 MPa<\/strong><\/p>\n<p>or approximately:<\/p>\n<p><strong>-1 bar to 200 bar<\/strong>.<\/p>\n<p>In imperial units, Fluke specifies:<\/p>\n<p><strong>-15 psi to 3,000 psi<\/strong>. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>The broad range makes the 2271A suitable for both relatively low pneumatic pressures and demanding industrial pressure calibration applications.<\/p>\n<p>The overall working range depends on the pressure measurement modules installed in the system. This means the instrument can be configured specifically for the customer&#8217;s actual calibration workload instead of relying on one fixed sensor range.<\/p>\n<h2>PM200 Pressure Measurement Modules<\/h2>\n<p>The <strong>PM200<\/strong> family provides an economical solution for many industrial pressure calibration tasks.<\/p>\n<p>For most commonly used PM200 ranges, Fluke specifies:<\/p>\n<p><strong>0.02% FS<\/strong>.<\/p>\n<p>This level of performance is particularly suitable for:<\/p>\n<ul>\n<li>Analog pressure gauges<\/li>\n<li>Lower-accuracy pressure transmitters<\/li>\n<li>Pressure switches<\/li>\n<li>General industrial pressure instruments<\/li>\n<\/ul>\n<p>The PM200 modules use rugged silicon pressure sensing technology and are designed to provide fast and reliable pressure control. <a href=\"https:\/\/www.fluke.com\/de-de\/produkt\/kalibratoren\/druckkalibratoren\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>Multiple PM200 ranges are available, extending from very low bidirectional pressures through gauge pressure ranges up to <strong>20 MPa \/ 3,000 psi<\/strong>. Individual accuracy specifications depend on the selected module, particularly for the lowest ranges. <a href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<h2>PM500 Pressure Measurement Modules<\/h2>\n<p>For more demanding calibration requirements, the <strong>Fluke Calibration 2271A<\/strong> also supports PM500 pressure measurement modules.<\/p>\n<p>PM500 modules use highly characterized and linearized silicon pressure sensors.<\/p>\n<p>For many ranges, Fluke specifies a measurement uncertainty of:<\/p>\n<p><strong>0.01% of reading<\/strong><\/p>\n<p>between approximately 50% and 100% of the range. <a href=\"https:\/\/www.fluke.com\/de-de\/produkt\/kalibratoren\/druckkalibratoren\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>This makes PM500 modules suitable for higher-accuracy pressure transmitters, digital pressure gauges and other devices requiring better measurement performance than the standard PM200 class.<\/p>\n<p>By combining PM200 and PM500 modules, a laboratory can match both accuracy and investment cost to its actual workload.<\/p>\n<h2>Modular Design<\/h2>\n<p>The modular design is one of the most important characteristics of the <strong>Fluke Calibration 2271A<\/strong>.<\/p>\n<p>Two measurement modules can be installed in the same chassis. Modules can be selected according to pressure range and required performance, then replaced when calibration requirements change. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>This provides several advantages.<\/p>\n<p>A laboratory can start with only the pressure ranges it currently requires.<\/p>\n<p>Additional ranges can be added later.<\/p>\n<p>A module can be replaced without purchasing a new controller.<\/p>\n<p>Different accuracy classes can be selected for different workloads.<\/p>\n<p>The investment therefore remains adaptable as the number and type of devices under test change.<\/p>\n<h2>Dynamic Pressure Control<\/h2>\n<p>The Fluke Calibration 2271A not only measures pressure but also automatically generates and regulates it when supplied with an appropriate pneumatic pressure source.<\/p>\n<p>For most ranges, Fluke specifies dynamic control precision of:<\/p>\n<p><strong>0.001% of range span<\/strong>.<\/p>\n<p>Special low-pressure configurations have different values. The PM200-BG2.5K is specified at <strong>0.005% of range span<\/strong>, while certain very low-pressure PM500 configurations are specified at <strong>0.002% of range span<\/strong>. <a href=\"https:\/\/www.fluke.com\/de-de\/produkt\/kalibratoren\/druckkalibratoren\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>This precise regulation enables the 2271A to establish repeatable calibration points automatically.<\/p>\n<h2>Control Turndown of 10:1<\/h2>\n<p>The typical control turndown is:<\/p>\n<p><strong>10:1<\/strong>. <a href=\"https:\/\/www.fluke.com\/de-de\/produkt\/kalibratoren\/druckkalibratoren\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>Fluke notes that the available supply pressure is an important factor in achieving the specified control performance. To meet the control specification, the supply pressure should not be greater than approximately ten times the range of the active measurement module.<\/p>\n<p>This is particularly relevant when very different pressure modules are installed in the same controller.<\/p>\n<h2>Fast Pressure Settling<\/h2>\n<p>The settling time depends on the installed module and the calibration setup.<\/p>\n<p>Fluke specifies typical settling times including approximately:<\/p>\n<p><strong>20 seconds<\/strong> for many PM200 modules<\/p>\n<p>and approximately:<\/p>\n<p><strong>30 to 45 seconds<\/strong> for PM500 modules depending on range. <a href=\"https:\/\/www.fluke.com\/de-de\/produkt\/kalibratoren\/druckkalibratoren\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>Actual settling time can also be influenced by test volume, pressure tubing, leaks, supply pressure and vacuum performance.<\/p>\n<p>Fast and repeatable pressure settling is important in automated calibration because it directly affects total calibration time.<\/p>\n<h2>Integrated Electrical Measurement Module<\/h2>\n<p>The <strong>Fluke Calibration 2271A<\/strong> integrates pressure and electrical calibration functions.<\/p>\n<p>Its Electrical Measurement Module enables measurements required for pressure transmitter calibration without the need for several separate instruments.<\/p>\n<p>The module supports electrical measurements through standard 4 mm connections and allows signals up to <strong>30 V DC<\/strong> relative to chassis ground. <a href=\"https:\/\/www.europascal.de\/download\/2178\/2271A-Industrial-Pressure-Calibrator.pdf?utm_source=chatgpt.com\">europascal.de<\/a><\/p>\n<p>The integrated concept simplifies calibration bench design and reduces setup time when pressure transmitters are regularly calibrated.<\/p>\n<h2>HART Pressure Transmitter Calibration<\/h2>\n<p>The EMM provides integrated <strong>HART communication<\/strong>.<\/p>\n<p>It also includes an internal:<\/p>\n<p><strong>250 \u03a9 resistor<\/strong><\/p>\n<p>that can be switched into the circuit when required for HART communication. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>This eliminates the need for an external resistor in many HART calibration setups.<\/p>\n<p>The 2271A can therefore support fully automated closed-loop calibration of smart pressure transmitters.<\/p>\n<p>Pressure is generated and controlled automatically, the transmitter is supplied with loop power, its electrical signal is measured and the calibration procedure can be evaluated automatically.<\/p>\n<h2>24 V Loop Power<\/h2>\n<p>The integrated Electrical Measurement Module also provides:<\/p>\n<p><strong>24 V DC loop power<\/strong>.<\/p>\n<p>This allows compatible two-wire pressure transmitters to be powered directly from the Fluke Calibration 2271A during calibration. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>A typical transmitter calibration setup can therefore use the 2271A for:<\/p>\n<p>pressure generation,<\/p>\n<p>reference pressure measurement,<\/p>\n<p>24 V transmitter supply,<\/p>\n<p>mA measurement,<\/p>\n<p>and HART communication.<\/p>\n<p>This significantly reduces external instrumentation and cabling.<\/p>\n<h2>Dual Test Ports<\/h2>\n<p>The Fluke Calibration 2271A incorporates <strong>dual test ports<\/strong>, allowing multiple devices under test to be connected conveniently. <a href=\"https:\/\/media.fluke.com\/2c86df71-8b56-4dec-9933-b2d6010c558e_original%20file.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>This can increase laboratory throughput when multiple pressure instruments need to be connected to the same pressure source.<\/p>\n<p>The test-port concept is also designed to support convenient connection and removal of devices without unnecessarily complicated adapter arrangements.<\/p>\n<p>Different chassis configurations are available with NPT, BSP and alternative test-port arrangements. <a href=\"https:\/\/www.fluke.com\/de-de\/produkt\/kalibratoren\/druckkalibratoren\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<h2>Pneumatic Pressure Calibration<\/h2>\n<p>The Fluke Calibration 2271A is a pneumatic pressure calibrator.<\/p>\n<p>Fluke specifies the pressure supply medium as:<\/p>\n<p><strong>clean, dry air<\/strong><\/p>\n<p>or:<\/p>\n<p><strong>nitrogen<\/strong>.<\/p>\n<p>For nitrogen, industrial grade with approximately <strong>99.5% purity<\/strong> is specified. <a href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>Fluke also places limits on particulate contamination, moisture and hydrocarbon content to protect the internal pneumatic system.<\/p>\n<p>A clean pneumatic supply is especially important for maintaining controller reliability and protecting the pressure measurement modules.<\/p>\n<h2>Optional Contamination Prevention System<\/h2>\n<p>Pressure instruments returning from industrial service may contain oil, moisture, particles or other contamination.<\/p>\n<p>To protect the controller from contamination entering through the device under test, Fluke offers an optional <strong>Contamination Prevention System<\/strong>, or CPS.<\/p>\n<p>The CPS uses a combination of controlled flow direction, a gravity sump and filtration to reduce the risk of contamination reaching the pressure controller. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>This option can be particularly valuable in calibration laboratories handling pressure gauges and transmitters from different customer applications.<\/p>\n<h2>Automated Pressure Transmitter Calibration<\/h2>\n<p>Automation is one of the strongest capabilities of the <strong>Fluke Calibration 2271A<\/strong>.<\/p>\n<p>Fluke describes workflows in which the calibrator automatically moves through predefined pressure points, waits for the selected dwell time, measures the transmitter output and evaluates the result against a defined tolerance. <a href=\"https:\/\/www.fluke.com\/en-ie\/learn\/blog\/calibration\/how-automate-calibration-analog-output-pressure-transmitters?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>The user can define:<\/p>\n<ul>\n<li>Start pressure<\/li>\n<li>End pressure<\/li>\n<li>Number of test points<\/li>\n<li>Direction of calibration<\/li>\n<li>Dwell time<\/li>\n<li>Maximum settling time<\/li>\n<li>DUT zero and full-scale values<\/li>\n<li>Pass\/fail tolerance<\/li>\n<\/ul>\n<p>Once started, the procedure can run in closed-loop mode with minimal operator intervention.<\/p>\n<p>This helps improve consistency between calibrations while allowing laboratory personnel to perform other tasks.<\/p>\n<h2>COMPASS for Pressure<\/h2>\n<p>The Fluke Calibration 2271A can be integrated with <strong>COMPASS for Pressure<\/strong> software for automated calibration and test sequences.<\/p>\n<p>COMPASS can support automated calibration of single or multiple devices under test and is designed specifically for pressure calibration applications. <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<p>The instrument also offers a full remote interface for integration into customer-specific software environments.<\/p>\n<h2>Ethernet, RS232 and USB<\/h2>\n<p>For automated operation, the 2271A provides:<\/p>\n<p><strong>Ethernet<\/strong><\/p>\n<p><strong>RS232<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>USB<\/strong>. <a href=\"https:\/\/www.europascal.de\/download\/2178\/2271A-Industrial-Pressure-Calibrator.pdf?utm_source=chatgpt.com\">europascal.de<\/a><\/p>\n<p>These interfaces provide flexibility when integrating the controller into an existing calibration laboratory, production test system or custom software environment.<\/p>\n<h2>Technical Highlights<\/h2>\n<p><strong>Model:<\/strong> Fluke Calibration 2271A<\/p>\n<p><strong>Device type:<\/strong> Modular automated pressure calibrator<\/p>\n<p><strong>Pressure range:<\/strong> -100 kPa to 20 MPa<\/p>\n<p><strong>Imperial range:<\/strong> -15 psi to 3,000 psi<\/p>\n<p><strong>Measurement modules:<\/strong> PM200 and PM500<\/p>\n<p><strong>Installed modules:<\/strong> up to two pressure measurement modules<\/p>\n<p><strong>PM200 performance:<\/strong> down to 0.02% FS for most industrial ranges<\/p>\n<p><strong>PM500 performance:<\/strong> down to 0.01% of reading for many ranges<\/p>\n<p><strong>Dynamic control precision:<\/strong> down to 0.001% of range span<\/p>\n<p><strong>Control turndown:<\/strong> 10:1 typical<\/p>\n<p><strong>Low control point:<\/strong> 1 kPa absolute<\/p>\n<p><strong>Electrical module:<\/strong> integrated EMM<\/p>\n<p><strong>Loop supply:<\/strong> 24 V DC<\/p>\n<p><strong>Communication with smart transmitters:<\/strong> HART<\/p>\n<p><strong>Remote interfaces:<\/strong> Ethernet, RS232, USB<\/p>\n<p><strong>Test ports:<\/strong> dual test ports<\/p>\n<p><strong>Pressure medium:<\/strong> clean dry air or nitrogen<\/p>\n<p><strong>Optional contamination protection:<\/strong> CPS<\/p>\n<p><strong>Warm-up time:<\/strong> approximately 15 minutes<\/p>\n<p><strong>Chassis weight:<\/strong> approximately 15 kg<\/p>\n<p>The specifications correspond to current Fluke manufacturer information and the 2271A documentation hosted by europascal. <a href=\"https:\/\/www.fluke.com\/de-de\/produkt\/kalibratoren\/druckkalibratoren\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<h2>Technical Data<\/h2>\n<div>\n<div>\n<div>\n<table>\n<thead>\n<tr>\n<th>Feature<\/th>\n<th>Fluke Calibration 2271A<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>2271A<\/td>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Automated Pressure Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Pressure range<\/td>\n<td>-100 kPa to 20 MPa<\/td>\n<\/tr>\n<tr>\n<td>Pressure range in psi<\/td>\n<td>-15 to 3,000 psi<\/td>\n<\/tr>\n<tr>\n<td>Maximum range in bar<\/td>\n<td>Approx. 200 bar<\/td>\n<\/tr>\n<tr>\n<td>Measurement modules<\/td>\n<td>PM200, PM500<\/td>\n<\/tr>\n<tr>\n<td>Module positions<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>PM200 performance<\/td>\n<td>Down to 0.02% FS<\/td>\n<\/tr>\n<tr>\n<td>PM500 performance<\/td>\n<td>Down to 0.01% reading<\/td>\n<\/tr>\n<tr>\n<td>Dynamic control precision<\/td>\n<td>Down to 0.001% range span<\/td>\n<\/tr>\n<tr>\n<td>Control turndown<\/td>\n<td>10:1 typical<\/td>\n<\/tr>\n<tr>\n<td>Low control point<\/td>\n<td>1 kPa absolute<\/td>\n<\/tr>\n<tr>\n<td>Electrical measurement<\/td>\n<td>Integrated EMM<\/td>\n<\/tr>\n<tr>\n<td>Loop supply<\/td>\n<td>24 V DC<\/td>\n<\/tr>\n<tr>\n<td>HART<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Test ports<\/td>\n<td>Dual<\/td>\n<\/tr>\n<tr>\n<td>Remote interfaces<\/td>\n<td>Ethernet, RS232, USB<\/td>\n<\/tr>\n<tr>\n<td>Supply medium<\/td>\n<td>Clean dry air or nitrogen<\/td>\n<\/tr>\n<tr>\n<td>Maximum supply pressure<\/td>\n<td>23 MPa gauge<\/td>\n<\/tr>\n<tr>\n<td>Maximum test-port pressure<\/td>\n<td>20 MPa absolute<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>15 \u00b0C to 35 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Warm-up<\/td>\n<td>Approx. 15 min<\/td>\n<\/tr>\n<tr>\n<td>Chassis weight<\/td>\n<td>Approx. 15 kg<\/td>\n<\/tr>\n<tr>\n<td>Width<\/td>\n<td>442 mm<\/td>\n<\/tr>\n<tr>\n<td>Depth<\/td>\n<td>446 mm<\/td>\n<\/tr>\n<tr>\n<td>Protection<\/td>\n<td>IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>The exact dimensions depend on the selected HC20 or P3000 test-port chassis configuration. <a href=\"https:\/\/www.europascal.de\/download\/2178\/2271A-Industrial-Pressure-Calibrator.pdf?utm_source=chatgpt.com\">europascal.de<\/a><\/p>\n<h2>Why Choose the Fluke Calibration 2271A?<\/h2>\n<p>The <strong>Fluke Calibration 2271A<\/strong> combines automatic pneumatic pressure control, modular reference measurement and electrical transmitter calibration in one professional platform.<\/p>\n<p>Its pressure range from <strong>-100 kPa to 20 MPa<\/strong> covers a large proportion of industrial pneumatic calibration workloads. Two interchangeable module positions allow users to combine different ranges, while the choice between PM200 and PM500 modules provides flexibility between economical industrial calibration and higher-accuracy applications.<\/p>\n<p>The integrated EMM makes the system particularly attractive for calibration laboratories working with pressure transmitters. mA and voltage measurement, 24 V loop power and integrated HART communication mean that many transmitter calibrations can be completed without additional electrical instrumentation.<\/p>\n<p>Automated pressure control, programmable procedures and compatibility with COMPASS for Pressure can reduce repetitive manual work and improve consistency in calibration processes.<\/p>\n<p>The optional CPS also helps protect the controller when pressure instruments returning from industrial service may contain contamination.<\/p>\n<p>For laboratories seeking a modular pressure calibration platform that can grow with changing workloads, the <strong>Fluke Calibration 2271A<\/strong> provides a flexible and scalable solution.<\/p>\n<p>europascal offers professional support for Fluke Calibration pressure equipment and is listed by Fluke as a regional service provider for pressure and flow calibration products. <a href=\"https:\/\/www.fluke.com\/de-de\/support\/servicecenter-standorte?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Fluke<\/a><\/p>\n<h2>Typical Applications with the Fluke Calibration 2271A<\/h2>\n<p>The <strong>Fluke Calibration 2271A<\/strong> is particularly suitable for automated calibration of pressure gauges, pressure transmitters, digital pressure indicators, pressure switches and pressure sensors.<\/p>\n<p>Its integrated HART functionality makes it especially useful for modern smart pressure transmitters, while the modular PM200 and PM500 concept enables calibration laboratories to match pressure range and accuracy to their workload.<\/p>\n<p>For complete pressure calibration workstations, europascal can support the selection of suitable measurement modules, pressure supply components, fittings and accessories.<\/p>\n<p>For traceable calibration of your pressure equipment, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/?utm_source=chatgpt.com\">europascal Calibration Service<\/a>.<\/p>\n<p>Further professional pressure calibration equipment can be found in the <a href=\"https:\/\/europascal.de\/produkt-kategorie\/druck\/?utm_source=chatgpt.com\">pressure technology section at europascal<\/a>. europascal currently lists a broad range of pressure controllers, calibrators, pressure modules and reference instruments. <a href=\"https:\/\/europascal.de\/produkt-kategorie\/druck\/?utm_source=chatgpt.com\">europascal.de<\/a><\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/?utm_source=chatgpt.com\">Further products from Fluke Calibration can be found here.<\/a> europascal lists Fluke Calibration as one of its core manufacturers for professional calibration technology and identifies itself as an authorized service center for Fluke Calibration pressure and flow products in the EMEA region. <a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/?utm_source=chatgpt.com\">europascal.de<\/a><\/p>\n<p><a href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/pressure-calibrators\/fluke-2271a?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">Manufacturer information about the Fluke Calibration 2271A can be found on the official Fluke Calibration website.<\/a><\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-2271A-Industrial-Pressure-Calibrator.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>Fluke Calibration 2271A<\/strong> is a modular automated pressure calibrator for professional calibration of pressure gauges, sensors, switches and transmitters from <strong>-100 kPa to 20 MPa (-15 to 3,000 psi)<\/strong>. Interchangeable PM200 and PM500 modules provide performance down to <strong>0.02% FS or 0.01% of reading<\/strong>, while the integrated Electrical Measurement Module offers mA and DC voltage measurement, 24 V loop power and HART communication. Automated pressure control, dual test ports and Ethernet, RS232 and USB interfaces make the 2271A ideal for efficient laboratory and industrial calibration.<\/p>\n","protected":false},"featured_media":3307,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[89],"product_cat":[45,47],"product_tag":[4196,4635,5747,4200,4201,4225,4583,4203,5748,5749,4205,3922,4395,4206,5750,5098,5099,4615],"class_list":["post-6748","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-calibration","product_cat-pressure","product_cat-pressure-controller-calibrator-indicator","product_tag-automatischer-druckkalibrator","product_tag-compass-for-pressure","product_tag-cps","product_tag-druckcontroller","product_tag-druckkalibrator","product_tag-druckkalibrierung","product_tag-druckschalter-pruefen","product_tag-drucktransmitter-kalibrieren","product_tag-fluke-2271a","product_tag-fluke-calibration-2271a","product_tag-hart-druckkalibrator","product_tag-kalibrierlabor","product_tag-kalibriertechnik","product_tag-manometer-kalibrieren","product_tag-modularer-druckkalibrator","product_tag-pm200","product_tag-pm500","product_tag-pneumatische-druckkalibrierung","pa_bauart-tischgeraet","pa_datenlogger-ja","pa_druckbereich--1-bar--20-bar--100-bar--200-bar","pa_genauigkeit--002-fs--001-rd","pa_hart-kommunikation-nein","pa_kanaele-strom-spannung","pa_manometer-typen-relativ-druck-compound-druck-absolut-druck","pa_medium-gas","pa_schnittstelle-rs232-usb-ethernet","pa_strom-versorgung-230v","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6748","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3307"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6748"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6748"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6748"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6748"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}