{"id":6825,"date":"2026-07-17T16:53:49","date_gmt":"2026-07-17T16:53:49","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-7102\/"},"modified":"2026-10-12T10:52:13","modified_gmt":"2026-10-12T10:52:13","slug":"fluke-calibration-7102","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-7102\/","title":{"rendered":"Fluke Calibration 7102 Portable Micro-Bath Calibrator"},"content":{"rendered":"<p>The <strong>Fluke Calibration 7102<\/strong> is a portable temperature calibration bath designed for accurate and reliable calibration of temperature sensors, thermometers and temperature switches. With a temperature range from <strong>\u22125 \u00b0C to +125 \u00b0C<\/strong>, excellent temperature stability and a compact liquid bath design, the Fluke Calibration 7102 combines the performance of a laboratory calibration bath with the convenience of a portable temperature calibrator.<\/p>\n<p>Unlike conventional dry-block calibrators, the Fluke Calibration 7102 uses a stirred liquid calibration medium to provide stable and uniform temperature conditions around the sensors under test.<\/p>\n<p>This makes the instrument particularly suitable for calibrating temperature probes with different diameters, lengths and shapes.<\/p>\n<p>The Fluke Calibration 7102 provides temperature stability of <strong>\u00b10.015 \u00b0C at \u22125 \u00b0C<\/strong> and <strong>\u00b10.03 \u00b0C at +121 \u00b0C<\/strong>, when operated with the specified calibration fluid.<\/p>\n<p>Its excellent temperature uniformity of <strong>\u00b10.02 \u00b0C<\/strong> supports accurate comparison calibration.<\/p>\n<p>The compact calibration chamber has a depth of 140 mm and a usable working diameter of 48 mm.<\/p>\n<p>With a weight of approximately <strong>6.8 kg including calibration fluid<\/strong>, the Fluke Calibration 7102 is easy to transport between calibration laboratories, production facilities and industrial measurement locations.<\/p>\n<p>The integrated solid-state cooling system allows temperatures below ambient conditions without requiring a conventional refrigeration compressor.<\/p>\n<p>Additional features include programmable temperature setpoints, adjustable ramp rates, temperature switch testing and RS-232 communication.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment and calibration services.<\/p>\n<p>For professional calibration and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Portable liquid temperature calibration bath<\/li>\n<li>Temperature range from \u22125 \u00b0C to +125 \u00b0C<\/li>\n<li>Temperature stability of \u00b10.015 \u00b0C at \u22125 \u00b0C<\/li>\n<li>Temperature stability of \u00b10.03 \u00b0C at +121 \u00b0C<\/li>\n<li>Temperature uniformity of \u00b10.02 \u00b0C<\/li>\n<li>Display accuracy of \u00b10.25 \u00b0C<\/li>\n<li>Temperature resolution of 0.01 \u00b0C<\/li>\n<li>Integrated solid-state cooling<\/li>\n<li>Compressor-free operation<\/li>\n<li>Compact and lightweight construction<\/li>\n<li>Approximately 6.8 kg including calibration fluid<\/li>\n<li>Calibration chamber depth of 140 mm<\/li>\n<li>Usable working diameter of 48 mm<\/li>\n<li>Suitable for different sensor shapes and sizes<\/li>\n<li>Suitable for short temperature probes<\/li>\n<li>Suitable for liquid-in-glass thermometers<\/li>\n<li>Suitable for bimetallic thermometers<\/li>\n<li>Suitable for Pt100 and RTD calibration<\/li>\n<li>Suitable for thermocouple calibration<\/li>\n<li>Integrated temperature switch testing<\/li>\n<li>Eight programmable temperature setpoints<\/li>\n<li>Adjustable temperature ramp rates<\/li>\n<li>RS-232 communication interface<\/li>\n<li>Overtemperature protection<\/li>\n<li>Transport lid with spill protection<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Portable Temperature Calibration from \u22125 \u00b0C to +125 \u00b0C<\/h2>\n<p>The <strong>Fluke Calibration 7102<\/strong> provides a controlled temperature environment over a range from:<\/p>\n<p><strong>\u22125 \u00b0C to +125 \u00b0C<\/strong><\/p>\n<p>This temperature range covers many important industrial and laboratory calibration applications.<\/p>\n<p>The instrument is particularly suitable for temperature measurements near ambient conditions and for applications requiring temperatures slightly below 0 \u00b0C.<\/p>\n<p>The integrated cooling system allows the bath to reach temperatures below ambient without requiring external refrigeration equipment.<\/p>\n<p>The liquid calibration medium provides excellent thermal contact between the reference thermometer and the sensors under test.<\/p>\n<p>This helps reduce measurement errors caused by poor thermal coupling.<\/p>\n<p>The compact construction allows the Fluke Calibration 7102 to be used in laboratories and directly at industrial measurement locations.<\/p>\n<h2>Excellent Temperature Stability<\/h2>\n<p>Temperature stability is one of the most important characteristics of a calibration bath.<\/p>\n<p>The Fluke Calibration 7102 provides excellent stability over its operating range.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.015 \u00b0C at \u22125 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.03 \u00b0C at +121 \u00b0C<\/strong><\/p>\n<p>These specifications apply when using Fluke Calibration 5010 oil under the specified operating conditions.<\/p>\n<p>Good temperature stability is particularly important during comparison calibration.<\/p>\n<p>It allows the reference thermometer and the device under test to be measured under nearly constant temperature conditions.<\/p>\n<p>This helps reduce uncertainty caused by temporal temperature fluctuations.<\/p>\n<h2>High Temperature Uniformity<\/h2>\n<p>The Fluke Calibration 7102 provides excellent temperature uniformity.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.02 \u00b0C<\/strong><\/p>\n<p>Temperature uniformity describes the temperature differences between different positions within the calibration zone.<\/p>\n<p>Good uniformity is particularly important when calibrating multiple temperature sensors simultaneously.<\/p>\n<p>The stirred liquid calibration medium provides effective thermal contact around the immersed probes.<\/p>\n<p>This allows temperature sensors with different geometries to be calibrated under comparable conditions.<\/p>\n<h2>Liquid Bath Technology<\/h2>\n<p>Unlike a conventional dry-block calibrator, the Fluke Calibration 7102 uses a liquid calibration medium.<\/p>\n<p>The liquid surrounds the immersed temperature sensors.<\/p>\n<p>This provides several advantages.<\/p>\n<p>The calibration medium adapts to different sensor diameters and shapes.<\/p>\n<p>It also reduces problems caused by poor contact between a probe and a calibration insert.<\/p>\n<p>The liquid bath design is particularly useful for short temperature probes, glass thermometers and mechanical thermometers.<\/p>\n<p>The Fluke Calibration 7102 therefore offers greater flexibility for certain applications than conventional dry-block calibrators.<\/p>\n<h2>Integrated Solid-State Cooling<\/h2>\n<p>One of the main advantages of the Fluke Calibration 7102 is its integrated cooling system.<\/p>\n<p>The instrument uses solid-state cooling technology.<\/p>\n<p>Unlike conventional refrigeration systems, it does not require a compressor.<\/p>\n<p>This reduces the number of moving components and contributes to a compact design.<\/p>\n<p>The cooling system allows the calibration bath to reach temperatures down to \u22125 \u00b0C.<\/p>\n<p>This makes the Fluke Calibration 7102 particularly suitable for calibration applications requiring temperatures below ambient conditions.<\/p>\n<h2>Compact Calibration Chamber<\/h2>\n<p>The Fluke Calibration 7102 features a compact liquid calibration chamber.<\/p>\n<p><strong>Chamber diameter: 64 mm<\/strong><\/p>\n<p><strong>Usable working diameter: 48 mm<\/strong><\/p>\n<p><strong>Chamber depth: 140 mm<\/strong><\/p>\n<p>The chamber provides sufficient space for many common temperature sensors.<\/p>\n<p>The usable working diameter allows different sensor configurations to be accommodated.<\/p>\n<p>For high-accuracy calibration, the sensors should be positioned correctly and immersed sufficiently.<\/p>\n<p>The actual measurement uncertainty depends on sensor geometry and temperature distribution within the bath.<\/p>\n<h2>Lightweight and Portable Design<\/h2>\n<p>The Fluke Calibration 7102 combines precision temperature calibration with excellent portability.<\/p>\n<p>The instrument weighs approximately:<\/p>\n<p><strong>6.8 kg including calibration fluid<\/strong><\/p>\n<p>Its external dimensions are:<\/p>\n<p><strong>180 \u00d7 310 \u00d7 240 mm<\/strong><\/p>\n<p>The compact design makes the instrument suitable for portable calibration applications.<\/p>\n<p>The Fluke Calibration 7102 can be transported between different measurement locations without requiring a large transport system.<\/p>\n<p>A specially designed transport lid helps prevent fluid leakage.<\/p>\n<p>The instrument can therefore be transported with calibration fluid inside when the manufacturer&#8217;s transport instructions are followed.<\/p>\n<h2>Calibration of Different Temperature Sensors<\/h2>\n<p>The Fluke Calibration 7102 is suitable for calibrating many different temperature measuring instruments.<\/p>\n<p>Typical examples include:<\/p>\n<ul>\n<li>Pt100 resistance thermometers<\/li>\n<li>Industrial RTD sensors<\/li>\n<li>Precision platinum resistance thermometers<\/li>\n<li>Thermocouples<\/li>\n<li>Liquid-in-glass thermometers<\/li>\n<li>Bimetallic thermometers<\/li>\n<li>Temperature switches<\/li>\n<li>Industrial temperature probes<\/li>\n<li>Laboratory temperature sensors<\/li>\n<\/ul>\n<p>The liquid calibration medium provides flexibility when working with different probe geometries.<\/p>\n<p>This is particularly useful for sensors that cannot be inserted into conventional dry-block calibration inserts.<\/p>\n<h2>Calibration of Pt100 and RTD Sensors<\/h2>\n<p>The Fluke Calibration 7102 is particularly suitable for Pt100 and RTD calibration.<\/p>\n<p>A calibrated reference thermometer and the resistance thermometer under test are immersed in the calibration bath.<\/p>\n<p>After the temperature has stabilized, the reference temperature and the indication of the device under test are recorded.<\/p>\n<p>The indication error is calculated as:<\/p>\n<p><strong>\u0394T = T_DUT \u2212 T_REF<\/strong><\/p>\n<p>Where:<\/p>\n<ul>\n<li>\u0394T = Temperature indication error<\/li>\n<li>T_DUT = Temperature indicated by the device under test<\/li>\n<li>T_REF = Reference temperature<\/li>\n<\/ul>\n<p>The resulting measurement values can be used to evaluate the performance of the temperature sensor.<\/p>\n<h2>Calibration of Thermocouples<\/h2>\n<p>The Fluke Calibration 7102 can also be used for thermocouple calibration.<\/p>\n<p>The thermocouple measuring junction is immersed in the liquid calibration bath.<\/p>\n<p>A suitable reference thermometer measures the actual bath temperature.<\/p>\n<p>The thermoelectric voltage of the thermocouple is measured using a compatible instrument.<\/p>\n<p>The measured voltage can then be compared with the expected thermoelectric voltage for the corresponding thermocouple type.<\/p>\n<p>The measurement uncertainty must consider the reference temperature, thermocouple measurement system and reference junction compensation.<\/p>\n<h2>Calibration of Liquid-in-Glass Thermometers<\/h2>\n<p>The Fluke Calibration 7102 is particularly useful for calibrating liquid-in-glass thermometers.<\/p>\n<p>These thermometers often have geometries that are difficult to accommodate in dry-block calibrators.<\/p>\n<p>The liquid bath provides a suitable temperature environment around the thermometer bulb.<\/p>\n<p>The indicated temperature can be compared with a calibrated reference thermometer.<\/p>\n<p>This makes the Fluke Calibration 7102 useful for laboratory glass thermometer calibration.<\/p>\n<h2>Calibration of Bimetallic Thermometers<\/h2>\n<p>Bimetallic thermometers are commonly used in industrial temperature measurement.<\/p>\n<p>Their sensing elements may have relatively large diameters or unusual shapes.<\/p>\n<p>The Fluke Calibration 7102 provides a liquid calibration environment that can accommodate many of these sensors.<\/p>\n<p>The thermometer can be immersed in the bath and compared with a calibrated reference thermometer.<\/p>\n<p>This allows the indication error to be determined at different temperature points.<\/p>\n<h2>Integrated Temperature Switch Testing<\/h2>\n<p>The Fluke Calibration 7102 includes connections for temperature switch testing.<\/p>\n<p>Temperature switches change their electrical contact state when a defined temperature is reached.<\/p>\n<p>The instrument allows the switching behavior to be evaluated during controlled temperature changes.<\/p>\n<p>This is particularly useful for testing thermostats and temperature-dependent switching devices.<\/p>\n<p>The adjustable temperature ramp rate supports controlled heating and cooling during switch testing.<\/p>\n<h2>Eight Programmable Temperature Setpoints<\/h2>\n<p>The Fluke Calibration 7102 provides memory for eight temperature setpoints.<\/p>\n<p>This allows frequently used calibration temperatures to be stored.<\/p>\n<p>The operator can select the required temperature without entering the value again.<\/p>\n<p>This feature is particularly useful for repeated calibration procedures.<\/p>\n<p>It simplifies operation and reduces setup time.<\/p>\n<h2>Adjustable Temperature Ramp Rate<\/h2>\n<p>The Fluke Calibration 7102 provides an adjustable temperature ramp rate.<\/p>\n<p>This allows the temperature to be changed at a controlled rate.<\/p>\n<p>Controlled temperature changes are particularly useful for temperature switch testing.<\/p>\n<p>They can also support calibration procedures requiring gradual temperature transitions.<\/p>\n<h2>RS-232 Communication Interface<\/h2>\n<p>The Fluke Calibration 7102 features an RS-232 interface.<\/p>\n<p>This allows the instrument to communicate with a computer.<\/p>\n<p>The interface can be used for remote control and automated calibration applications.<\/p>\n<p>The instrument is supplied with Fluke Calibration Interface-it software.<\/p>\n<p>It can also be used with compatible MET\/TEMP II software.<\/p>\n<p>This provides additional flexibility for professional calibration laboratories.<\/p>\n<h2>Overtemperature Protection<\/h2>\n<p>The Fluke Calibration 7102 includes an overtemperature safety cutout.<\/p>\n<p>This function helps protect the instrument against excessive temperatures.<\/p>\n<p>The maximum permissible operating temperature also depends on the selected calibration fluid.<\/p>\n<p>The temperature limits of the fluid must always be considered.<\/p>\n<p>The instrument should not be operated outside the permitted operating conditions of the calibration medium.<\/p>\n<h2>Heating and Cooling Performance<\/h2>\n<p>The Fluke Calibration 7102 provides efficient heating and cooling within its operating range.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Heating from 25 \u00b0C to 100 \u00b0C: approximately 30 minutes<\/strong><\/p>\n<p><strong>Cooling from 25 \u00b0C to 0 \u00b0C: approximately 30 minutes<\/strong><\/p>\n<p>These values provide an indication of the instrument&#8217;s temperature adjustment performance.<\/p>\n<p>The actual heating and cooling times depend on the calibration fluid, ambient conditions and operating configuration.<\/p>\n<h2>Suitable Calibration Fluids<\/h2>\n<p>The Fluke Calibration 7102 requires a suitable liquid calibration medium.<\/p>\n<p>Fluke Calibration specifies performance values using Fluke Calibration 5010 oil.<\/p>\n<p>The selected fluid must provide suitable thermal properties and remain stable over the required temperature range.<\/p>\n<p>Important considerations include:<\/p>\n<ul>\n<li>Operating temperature range<\/li>\n<li>Viscosity<\/li>\n<li>Thermal stability<\/li>\n<li>Flash point<\/li>\n<li>Boiling point<\/li>\n<li>Chemical compatibility<\/li>\n<li>Safety requirements<\/li>\n<\/ul>\n<p>The correct fluid selection is essential for reliable calibration results.<\/p>\n<h2>Temperature Comparison Calibration<\/h2>\n<p>The Fluke Calibration 7102 is designed for temperature comparison calibration.<\/p>\n<p>A calibrated reference thermometer and the device under test are placed in the same liquid calibration bath.<\/p>\n<p>After thermal equilibrium has been reached, the reference temperature and the indication of the device under test are recorded.<\/p>\n<p>The difference between both values determines the indication error.<\/p>\n<p>For high-accuracy calibration, the measurement uncertainty must include relevant contributions from the reference thermometer, temperature stability, temperature uniformity and measurement conditions.<\/p>\n<h2>Use with External Reference Thermometers<\/h2>\n<p>The Fluke Calibration 7102 can be used with an external reference thermometer.<\/p>\n<p>This is particularly useful when low measurement uncertainty is required.<\/p>\n<p>The internal temperature controller regulates the bath temperature.<\/p>\n<p>The external reference thermometer measures the actual temperature of the calibration medium.<\/p>\n<p>The reference temperature is then used to evaluate the indication error of the device under test.<\/p>\n<p>Suitable reference thermometers include calibrated platinum resistance thermometers connected to precision thermometer readouts.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Fluke Calibration 7102<\/th>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Portable Micro-Bath Temperature Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u22125 \u00b0C to +125 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability at \u22125 \u00b0C<\/td>\n<td>\u00b10.015 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability at +121 \u00b0C<\/td>\n<td>\u00b10.03 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature uniformity<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature resolution<\/td>\n<td>0.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibration chamber diameter<\/td>\n<td>64 mm<\/td>\n<\/tr>\n<tr>\n<td>Usable working diameter<\/td>\n<td>48 mm<\/td>\n<\/tr>\n<tr>\n<td>Calibration chamber depth<\/td>\n<td>140 mm<\/td>\n<\/tr>\n<tr>\n<td>Bath volume<\/td>\n<td>0.75 L<\/td>\n<\/tr>\n<tr>\n<td>Weight with fluid<\/td>\n<td>6.8 kg<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>180 \u00d7 310 \u00d7 240 mm<\/td>\n<\/tr>\n<tr>\n<td>Operating ambient temperature<\/td>\n<td>+5 \u00b0C to +45 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Heating time, 25 \u00b0C to 100 \u00b0C<\/td>\n<td>30 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, 25 \u00b0C to 0 \u00b0C<\/td>\n<td>30 minutes<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>115 \/ 230 V AC, switchable<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>50 \/ 60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>200 W<\/td>\n<\/tr>\n<tr>\n<td>Communication interface<\/td>\n<td>RS-232<\/td>\n<\/tr>\n<tr>\n<td>Cooling system<\/td>\n<td>Solid-state cooling<\/td>\n<\/tr>\n<tr>\n<td>Temperature switch testing<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Programmable setpoints<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>Adjustable ramp rate<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Overtemperature protection<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>NIST-traceable calibration<\/td>\n<td>Included<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 7102 vs. 6102 vs. 7103<\/h2>\n<p>The Fluke Calibration 7102, 6102 and 7103 belong to the same portable Micro-Bath series.<\/p>\n<p>However, the instruments cover different temperature ranges.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Fluke Calibration 7102<\/th>\n<th>Fluke Calibration 6102<\/th>\n<th>Fluke Calibration 7103<\/th>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u22125 \u00b0C to +125 \u00b0C<\/td>\n<td>+35 \u00b0C to +200 \u00b0C<\/td>\n<td>\u221230 \u00b0C to +125 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature uniformity<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Bath volume<\/td>\n<td>0.75 L<\/td>\n<td>0.75 L<\/td>\n<td>1.0 L<\/td>\n<\/tr>\n<tr>\n<td>Weight with fluid<\/td>\n<td>6.8 kg<\/td>\n<td>4.5 kg<\/td>\n<td>9.8 kg<\/td>\n<\/tr>\n<tr>\n<td>RS-232 interface<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Main advantage<\/td>\n<td>Cooling below ambient<\/td>\n<td>Higher temperatures<\/td>\n<td>Extended low-temperature range<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The Fluke Calibration 7102 is particularly suitable for applications requiring temperatures slightly below 0 \u00b0C.<\/p>\n<p>The Fluke Calibration 6102 is designed for applications requiring temperatures up to 200 \u00b0C.<\/p>\n<p>The Fluke Calibration 7103 extends the lower temperature limit to \u221230 \u00b0C.<\/p>\n<h2>Typical Applications<\/h2>\n<p>The <strong>Fluke Calibration 7102<\/strong> is suitable for:<\/p>\n<ul>\n<li>Temperature calibration laboratories<\/li>\n<li>Industrial temperature calibration<\/li>\n<li>Pt100 calibration<\/li>\n<li>RTD calibration<\/li>\n<li>Thermocouple calibration<\/li>\n<li>Temperature switch testing<\/li>\n<li>Liquid-in-glass thermometer calibration<\/li>\n<li>Bimetallic thermometer calibration<\/li>\n<li>Temperature comparison calibration<\/li>\n<li>Portable temperature calibration<\/li>\n<li>On-site temperature calibration<\/li>\n<li>Laboratory temperature measurements<\/li>\n<li>Quality assurance<\/li>\n<li>Maintenance departments<\/li>\n<li>Temperature metrology<\/li>\n<\/ul>\n<h2>Calibration by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable temperature calibration results.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and temperature calibration equipment.<\/p>\n<p>The Fluke Calibration 7102 can be calibrated to determine its temperature indication error and relevant performance characteristics.<\/p>\n<p>For high-accuracy applications, the instrument can be used with a calibrated external reference thermometer.<\/p>\n<p>The overall measurement uncertainty depends on the calibration bath, reference thermometer, measurement conditions and calibration procedure.<\/p>\n<p>For professional calibration and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p>europascal also supports customers in selecting suitable temperature calibration baths, reference thermometers and complete calibration systems.<\/p>\n<h2>Why Choose the Fluke Calibration 7102?<\/h2>\n<p>The <strong>Fluke Calibration 7102<\/strong> combines the performance of a precision liquid calibration bath with the convenience of a compact portable instrument.<\/p>\n<p>Its temperature range from \u22125 \u00b0C to +125 \u00b0C covers many important industrial and laboratory calibration applications.<\/p>\n<p>The integrated solid-state cooling system allows temperatures below ambient without requiring a conventional refrigeration compressor.<\/p>\n<p>The instrument provides excellent temperature stability and uniformity.<\/p>\n<p>Its liquid bath design allows temperature sensors with different geometries to be calibrated without requiring precisely matched dry-block inserts.<\/p>\n<p>The compact calibration chamber is particularly suitable for short temperature probes, glass thermometers and bimetallic thermometers.<\/p>\n<p>With a weight of approximately 6.8 kg including fluid, the Fluke Calibration 7102 is easy to transport.<\/p>\n<p>Additional features such as RS-232 communication, temperature switch testing, programmable setpoints and overtemperature protection provide flexibility for professional calibration applications.<\/p>\n<p>For laboratories and industrial users requiring a portable liquid temperature calibration bath with integrated cooling, the Fluke Calibration 7102 offers an excellent combination of precision, portability and versatility.<\/p>\n<p>europascal supports customers with temperature calibration equipment, reference thermometers and professional calibration services.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Further products from Fluke Calibration can be found here.<\/a><\/p>\n<p><a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/temperature-calibrators\/fluke-calibration-6102-7102-7103\" target=\"_blank\" rel=\"noopener\">Manufacturer information about the Fluke Calibration 7102 can be found on the official Fluke website.<\/a><\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-Temperaturkalibrierung-Anwendungen-und-L\u00f6sungen.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Datenblatt herunterladen<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 7102<\/strong> is a compact, portable Micro-Bath temperature calibrator designed for accurate calibration from <strong>\u22125 \u00b0C to +125 \u00b0C<\/strong>. Featuring temperature stability of <strong>\u00b10.015 \u00b0C at \u22125 \u00b0C<\/strong>, uniformity of <strong>\u00b10.02 \u00b0C<\/strong> and a 140 mm deep liquid calibration chamber, the instrument is ideal for calibrating Pt100 sensors, thermocouples, glass thermometers and temperature switches. Weighing approximately <strong>6.8 kg including fluid<\/strong>, the Fluke Calibration 7102 combines excellent liquid bath performance with portable solid-state cooling. Additional features include RS-232 communication, eight programmable temperature setpoints and integrated temperature switch testing.<\/p>\n","protected":false},"featured_media":3470,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[55,53],"product_tag":[6021,6006,6022,6023,6009,4125,6024,3922,5873,6011,6012,6013,3994,3995,6014,4000,4001,5825,6015,5980],"class_list":["post-6825","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-liquid-bath-micro-bath","product_cat-temperature","product_tag-7102-micro-bath","product_tag-bimetallthermometer-kalibrieren","product_tag-fluke-7102","product_tag-fluke-calibration-7102","product_tag-fluessigkeits-glasthermometer","product_tag-fluessigkeitsbad","product_tag-kalibrierbad-minus-5-c","product_tag-kalibrierlabor","product_tag-met-temp-ii","product_tag-micro-bath","product_tag-mikrokalibrierbad","product_tag-mobiles-kalibrierbad","product_tag-prt-kalibrieren","product_tag-pt100-kalibrieren","product_tag-temperaturkalibrierbad","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-temperaturschalter-pruefen","product_tag-thermistor-kalibrieren","product_tag-thermometer-kalibrieren","pa_bauart-tisch","pa_genauigkeit--025-c","pa_medium-oel","pa_messbereich-300c","pa_schnittstelle-rs232","pa_stabilitaet-002-c","pa_strom-versorgung-230v","pa_temperaturbereich-35c-bis-200c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3470"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6825"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6825"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6825"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}