{"id":6832,"date":"2026-07-17T16:53:29","date_gmt":"2026-07-17T16:53:29","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-9132\/"},"modified":"2026-10-12T11:13:17","modified_gmt":"2026-10-12T11:13:17","slug":"fluke-calibration-9132","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-9132\/","title":{"rendered":"Fluke Calibration 9132 Portable Infrared Calibrator"},"content":{"rendered":"<p>The <strong>Fluke Calibration 9132<\/strong> is a compact, portable infrared temperature calibrator designed for accurate and reliable calibration of non-contact infrared thermometers, pyrometers and industrial infrared temperature measurement systems.<\/p>\n<p>With a temperature range from <strong>+50 \u00b0C to +500 \u00b0C<\/strong>, a 57 mm blackbody target and excellent temperature stability, the Fluke Calibration 9132 provides a practical solution for professional infrared temperature calibration.<\/p>\n<p>The instrument features a temperature-controlled blackbody surface with a nominal emissivity of <strong>0.95<\/strong>, making it suitable for calibrating infrared thermometers operating in the corresponding spectral range.<\/p>\n<p>The Fluke Calibration 9132 combines laboratory calibration performance with a compact design that makes it suitable for industrial maintenance, quality assurance and portable calibration applications.<\/p>\n<p>Its temperature accuracy reaches <strong>\u00b10.5 \u00b0C at 100 \u00b0C<\/strong> and <strong>\u00b10.8 \u00b0C at 500 \u00b0C<\/strong>, while temperature stability is specified as <strong>\u00b10.1 \u00b0C at 100 \u00b0C<\/strong> and <strong>\u00b10.3 \u00b0C at 500 \u00b0C<\/strong>.<\/p>\n<p>The instrument provides a temperature resolution of 0.1 \u00b0C and features an RS-232 communication interface for computer-controlled operation.<\/p>\n<p>With a weight of approximately <strong>1.8 kg<\/strong>, the Fluke Calibration 9132 is particularly suitable for applications requiring a lightweight and portable infrared calibration source.<\/p>\n<p>europascal supports customers with professional infrared temperature calibration equipment, reference thermometers and calibration services.<\/p>\n<p>For professional calibration and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Portable infrared temperature calibrator<\/li>\n<li>Temperature range from +50 \u00b0C to +500 \u00b0C<\/li>\n<li>Blackbody target diameter of 57 mm<\/li>\n<li>Nominal target emissivity of 0.95<\/li>\n<li>Temperature accuracy of \u00b10.5 \u00b0C at 100 \u00b0C<\/li>\n<li>Temperature accuracy of \u00b10.8 \u00b0C at 500 \u00b0C<\/li>\n<li>Temperature stability of \u00b10.1 \u00b0C at 100 \u00b0C<\/li>\n<li>Temperature stability of \u00b10.3 \u00b0C at 500 \u00b0C<\/li>\n<li>Temperature resolution of 0.1 \u00b0C<\/li>\n<li>Compact and lightweight construction<\/li>\n<li>Weight of approximately 1.8 kg<\/li>\n<li>Fast heating and cooling performance<\/li>\n<li>Suitable for infrared thermometer calibration<\/li>\n<li>Suitable for industrial pyrometer calibration<\/li>\n<li>Suitable for non-contact temperature measurement systems<\/li>\n<li>Integrated reference well for contact temperature measurements<\/li>\n<li>RS-232 communication interface<\/li>\n<li>Compatible with Interface-it software<\/li>\n<li>Suitable for laboratory and field applications<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Infrared Temperature Calibration from 50 \u00b0C to 500 \u00b0C<\/h2>\n<p>The <strong>Fluke Calibration 9132<\/strong> provides a controlled infrared calibration target over a temperature range from:<\/p>\n<p><strong>+50 \u00b0C to +500 \u00b0C<\/strong><\/p>\n<p>This temperature range covers many important industrial infrared temperature measurement applications.<\/p>\n<p>The instrument is particularly suitable for calibrating infrared thermometers used in manufacturing, maintenance and quality assurance.<\/p>\n<p>The temperature-controlled blackbody target provides a stable thermal radiation source.<\/p>\n<p>An infrared thermometer can be directed toward the target to compare its indicated temperature with the reference temperature.<\/p>\n<p>This allows the measurement error of the infrared thermometer to be determined at different calibration points.<\/p>\n<h2>Blackbody Calibration Target<\/h2>\n<p>The Fluke Calibration 9132 features a blackbody calibration target with a diameter of:<\/p>\n<p><strong>57 mm (2.25 inches)<\/strong><\/p>\n<p>The target provides a temperature-controlled surface for non-contact temperature measurements.<\/p>\n<p>Its relatively large diameter allows many handheld infrared thermometers and industrial pyrometers to be calibrated.<\/p>\n<p>For accurate measurements, the infrared thermometer must be positioned so that its complete measurement spot lies within the blackbody target.<\/p>\n<p>The required measurement distance depends on the optical characteristics of the infrared thermometer.<\/p>\n<p>These characteristics are commonly specified by the distance-to-spot ratio.<\/p>\n<h2>Target Emissivity of 0.95<\/h2>\n<p>The Fluke Calibration 9132 provides a nominal target emissivity of:<\/p>\n<p><strong>\u03b5 = 0.95<\/strong><\/p>\n<p>The manufacturer specifies an emissivity tolerance of:<\/p>\n<p><strong>\u00b10.02 in the spectral range from 8 \u00b5m to 14 \u00b5m<\/strong><\/p>\n<p>Emissivity describes how effectively a surface emits thermal radiation compared with an ideal blackbody at the same temperature.<\/p>\n<p>An ideal blackbody has an emissivity of 1.<\/p>\n<p>The Fluke Calibration 9132 provides a controlled radiation source with an emissivity close to this ideal value.<\/p>\n<p>When calibrating infrared thermometers, the emissivity setting of the device under test must be considered.<\/p>\n<p>For instruments with adjustable emissivity, the setting should correspond to the calibration conditions.<\/p>\n<p>The spectral response of the infrared thermometer must also be considered.<\/p>\n<h2>Accurate Temperature Control<\/h2>\n<p>The Fluke Calibration 9132 provides accurate temperature control throughout its operating range.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.5 \u00b0C at 100 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.8 \u00b0C at 500 \u00b0C<\/strong><\/p>\n<p>These values describe the specified temperature accuracy of the calibration source.<\/p>\n<p>They must not be confused with the measurement uncertainty of a complete infrared thermometer calibration.<\/p>\n<p>The overall calibration uncertainty also depends on the infrared thermometer, measurement distance, target size, emissivity and ambient conditions.<\/p>\n<h2>Excellent Temperature Stability<\/h2>\n<p>Temperature stability is an important characteristic of an infrared temperature calibrator.<\/p>\n<p>The Fluke Calibration 9132 provides:<\/p>\n<p><strong>\u00b10.1 \u00b0C stability at 100 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.3 \u00b0C stability at 500 \u00b0C<\/strong><\/p>\n<p>Good temperature stability helps maintain constant thermal radiation conditions during calibration.<\/p>\n<p>This is particularly important when calibrating infrared thermometers at several temperature points.<\/p>\n<p>The stable blackbody target allows the operator to compare the indication of the device under test with the reference temperature.<\/p>\n<h2>Fast Heating and Cooling<\/h2>\n<p>The Fluke Calibration 9132 provides efficient heating and cooling performance.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Heating from 50 \u00b0C to 500 \u00b0C: approximately 30 minutes<\/strong><\/p>\n<p><strong>Cooling from 500 \u00b0C to 100 \u00b0C: approximately 30 minutes<\/strong><\/p>\n<p>These values allow calibration procedures to be performed efficiently.<\/p>\n<p>The actual heating and cooling times depend on operating conditions and ambient temperature.<\/p>\n<h2>Calibration of Infrared Thermometers<\/h2>\n<p>The Fluke Calibration 9132 is designed for calibrating non-contact infrared thermometers.<\/p>\n<p>The calibration procedure is based on comparing the temperature indication of the infrared thermometer with the temperature of a controlled radiation source.<\/p>\n<p>A typical procedure includes selecting the required calibration temperature, allowing the blackbody target to stabilize and positioning the infrared thermometer at a suitable measurement distance.<\/p>\n<p>The complete measurement spot must remain within the target surface.<\/p>\n<p>The temperature indicated by the infrared thermometer is then recorded.<\/p>\n<p>The indication error can be calculated as:<\/p>\n<p><strong>\u0394T = T_DUT \u2212 T_REF<\/strong><\/p>\n<p>Where:<\/p>\n<ul>\n<li>\u0394T = Temperature indication error<\/li>\n<li>T_DUT = Temperature indicated by the infrared thermometer<\/li>\n<li>T_REF = Reference radiation temperature<\/li>\n<\/ul>\n<p>The resulting measurement values can be used to evaluate the performance of the infrared thermometer.<\/p>\n<p>For accurate calibration, the reference temperature must be appropriate for the spectral characteristics and emissivity setting of the device under test.<\/p>\n<h2>Calibration of Industrial Pyrometers<\/h2>\n<p>The Fluke Calibration 9132 is also suitable for calibrating industrial infrared pyrometers.<\/p>\n<p>Pyrometers are commonly used for non-contact temperature measurement in industrial processes.<\/p>\n<p>Typical applications include temperature monitoring of machinery, production equipment and heated components.<\/p>\n<p>The Fluke Calibration 9132 provides a stable radiation target for checking the measurement performance of these instruments.<\/p>\n<p>The pyrometer is aligned with the blackbody target and its indicated temperature is compared with the reference temperature.<\/p>\n<p>This allows measurement deviations to be identified.<\/p>\n<p>The optical alignment, measurement distance and spectral response of the pyrometer must be considered.<\/p>\n<h2>Importance of Measurement Distance<\/h2>\n<p>Measurement distance is an important factor in infrared temperature calibration.<\/p>\n<p>Infrared thermometers measure thermal radiation from a defined field of view.<\/p>\n<p>The measurement spot generally increases with distance.<\/p>\n<p>If the measurement spot becomes larger than the blackbody target, radiation from the surrounding environment can influence the measurement result.<\/p>\n<p>This can cause significant measurement errors.<\/p>\n<p>The Fluke Calibration 9132 provides a 57 mm target diameter.<\/p>\n<p>The operator must ensure that the infrared thermometer measures only the intended target area.<\/p>\n<p>A suitable measurement distance should be selected according to the optical specifications of the device under test.<\/p>\n<h2>Infrared Calibration and Measurement Uncertainty<\/h2>\n<p>Infrared temperature calibration requires consideration of several measurement uncertainty contributions.<\/p>\n<p>These include the calibration source accuracy, temperature stability, target emissivity, infrared thermometer resolution and measurement repeatability.<\/p>\n<p>Additional influences may include the spectral response of the infrared thermometer, measurement distance, target size and ambient radiation.<\/p>\n<p>The effective radiation temperature may differ from the physical temperature of the target.<\/p>\n<p>This is particularly important when calibrating infrared thermometers with spectral characteristics that differ from the specified emissivity range.<\/p>\n<p>For high-accuracy calibration, a suitable radiometric reference and an appropriate uncertainty budget are required.<\/p>\n<h2>Integrated Reference Well<\/h2>\n<p>The Fluke Calibration 9132 includes a reference well positioned behind the blackbody surface.<\/p>\n<p>This allows contact temperature measurements using a suitable temperature probe.<\/p>\n<p>The reference well can be used to check the temperature of the calibration source.<\/p>\n<p>However, the temperature measured by a contact thermometer is not automatically identical to the effective radiation temperature observed by an infrared thermometer.<\/p>\n<p>For accurate infrared calibration, the emissivity and radiometric characteristics of the source must be considered.<\/p>\n<h2>RS-232 Communication Interface<\/h2>\n<p>The Fluke Calibration 9132 features an integrated RS-232 interface.<\/p>\n<p>This allows the instrument to communicate with a computer.<\/p>\n<p>The interface can be used for remote control and monitoring of temperature setpoints.<\/p>\n<p>The manufacturer specifies compatibility with Fluke Calibration Interface-it software.<\/p>\n<p>This provides additional flexibility for professional calibration laboratories.<\/p>\n<h2>Compact and Portable Design<\/h2>\n<p>The Fluke Calibration 9132 is designed for portable infrared temperature calibration.<\/p>\n<p>The instrument weighs approximately:<\/p>\n<p><strong>1.8 kg<\/strong><\/p>\n<p>Its external dimensions are:<\/p>\n<p><strong>102 \u00d7 152 \u00d7 178 mm<\/strong><\/p>\n<p>The compact construction makes the instrument suitable for industrial maintenance and field calibration.<\/p>\n<p>The small size allows the Fluke Calibration 9132 to be transported between different measurement locations.<\/p>\n<p>It is also suitable for use on laboratory workbenches where space is limited.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Fluke Calibration 9132<\/th>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Portable Infrared Temperature Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>+50 \u00b0C to +500 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature accuracy at 100 \u00b0C<\/td>\n<td>\u00b10.5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature accuracy at 500 \u00b0C<\/td>\n<td>\u00b10.8 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability at 100 \u00b0C<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability at 500 \u00b0C<\/td>\n<td>\u00b10.3 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Blackbody target diameter<\/td>\n<td>57 mm<\/td>\n<\/tr>\n<tr>\n<td>Nominal target emissivity<\/td>\n<td>0.95<\/td>\n<\/tr>\n<tr>\n<td>Emissivity tolerance<\/td>\n<td>\u00b10.02<\/td>\n<\/tr>\n<tr>\n<td>Specified emissivity wavelength range<\/td>\n<td>8 \u00b5m to 14 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td>Temperature resolution<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Heating time from 50 \u00b0C to 500 \u00b0C<\/td>\n<td>Approximately 30 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time from 500 \u00b0C to 100 \u00b0C<\/td>\n<td>Approximately 30 minutes<\/td>\n<\/tr>\n<tr>\n<td>Reference well<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Communication interface<\/td>\n<td>RS-232<\/td>\n<\/tr>\n<tr>\n<td>Software compatibility<\/td>\n<td>Interface-it<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>115 V or 230 V AC, switchable<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>50 \/ 60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>340 W<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>102 \u00d7 152 \u00d7 178 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>1.8 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 9132 vs. Fluke Calibration 9133<\/h2>\n<p>The Fluke Calibration 9132 and 9133 are portable infrared temperature calibrators designed for different temperature ranges.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Fluke Calibration 9132<\/th>\n<th>Fluke Calibration 9133<\/th>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>+50 \u00b0C to +500 \u00b0C<\/td>\n<td>\u221230 \u00b0C to +150 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature accuracy<\/td>\n<td>\u00b10.5 \u00b0C at 100 \u00b0C; \u00b10.8 \u00b0C at 500 \u00b0C<\/td>\n<td>\u00b10.4 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.1 \u00b0C at 100 \u00b0C; \u00b10.3 \u00b0C at 500 \u00b0C<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Blackbody target diameter<\/td>\n<td>57 mm<\/td>\n<td>57 mm<\/td>\n<\/tr>\n<tr>\n<td>Nominal emissivity<\/td>\n<td>0.95<\/td>\n<td>0.95<\/td>\n<\/tr>\n<tr>\n<td>Temperature resolution<\/td>\n<td>0.1 \u00b0C<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>RS-232 interface<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>1.8 kg<\/td>\n<td>4.6 kg<\/td>\n<\/tr>\n<tr>\n<td>Main advantage<\/td>\n<td>Higher temperature range<\/td>\n<td>Low-temperature calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The Fluke Calibration 9132 is particularly suitable for infrared thermometer calibration at elevated temperatures.<\/p>\n<p>The Fluke Calibration 9133 is designed for applications requiring temperatures below ambient conditions.<\/p>\n<h2>Typical Applications<\/h2>\n<p>The <strong>Fluke Calibration 9132<\/strong> is suitable for infrared temperature calibration in a wide range of industrial and laboratory environments.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Infrared thermometer calibration<\/li>\n<li>Industrial pyrometer calibration<\/li>\n<li>Non-contact temperature measurement<\/li>\n<li>Portable infrared calibration<\/li>\n<li>Laboratory infrared calibration<\/li>\n<li>Industrial maintenance<\/li>\n<li>Quality assurance<\/li>\n<li>Production process monitoring<\/li>\n<li>Temperature measurement verification<\/li>\n<li>Calibration of handheld infrared thermometers<\/li>\n<li>Calibration of fixed infrared temperature sensors<\/li>\n<li>Temperature metrology<\/li>\n<\/ul>\n<h2>Calibration by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable infrared temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and infrared temperature measurement equipment.<\/p>\n<p>The Fluke Calibration 9132 can be used as a controlled radiation source for calibrating infrared thermometers and industrial pyrometers.<\/p>\n<p>For high-accuracy applications, the calibration procedure must consider the radiometric characteristics of the source and the spectral response of the device under test.<\/p>\n<p>The overall measurement uncertainty depends on the calibration source, emissivity, measurement distance, target size and environmental conditions.<\/p>\n<p>For professional calibration and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p>europascal also supports customers in selecting suitable infrared temperature calibrators and reference measurement equipment.<\/p>\n<h2>Why Choose the Fluke Calibration 9132?<\/h2>\n<p>The <strong>Fluke Calibration 9132<\/strong> combines accurate temperature control, a stable blackbody radiation target and a compact portable design.<\/p>\n<p>Its temperature range from +50 \u00b0C to +500 \u00b0C covers many important industrial infrared temperature calibration applications.<\/p>\n<p>The 57 mm blackbody target provides a suitable radiation source for many handheld infrared thermometers and industrial pyrometers.<\/p>\n<p>The nominal emissivity of 0.95 supports calibration of instruments designed for common industrial infrared measurement applications.<\/p>\n<p>Temperature accuracy of \u00b10.5 \u00b0C at 100 \u00b0C and \u00b10.8 \u00b0C at 500 \u00b0C provides reliable reference conditions.<\/p>\n<p>Fast heating and cooling performance helps reduce waiting times during calibration.<\/p>\n<p>The RS-232 communication interface supports computer-controlled operation.<\/p>\n<p>With a weight of only 1.8 kg, the Fluke Calibration 9132 is particularly suitable for portable calibration applications.<\/p>\n<p>For laboratories and industrial users requiring a compact infrared temperature calibration source, the Fluke Calibration 9132 offers an excellent combination of accuracy, portability and versatility.<\/p>\n<p>europascal supports customers with infrared temperature calibration equipment, reference thermometers and professional calibration services.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Further products from Fluke Calibration can be found here.<\/a><\/p>\n<p><a href=\"https:\/\/www.fluke.com\/de-de\/produkt\/kalibratoren\/temperaturkalibratoren\/fluke-calibration-9132-9133\" target=\"_blank\" rel=\"noopener\">Manufacturer information about the Fluke Calibration 9132 can be found on the official Fluke website.<\/a><\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-9132-9133-PortableInfrared-Calibratorwith-Blackbody-Source.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 9132<\/strong> is a compact, portable infrared temperature calibrator designed for accurate calibration from <strong>+50 \u00b0C to +500 \u00b0C<\/strong>. Featuring a <strong>57 mm blackbody target<\/strong>, nominal emissivity of <strong>0.95<\/strong> and temperature accuracy of <strong>\u00b10.5 \u00b0C at 100 \u00b0C<\/strong>, the instrument is ideal for calibrating handheld infrared thermometers and industrial pyrometers. Weighing only <strong>1.8 kg<\/strong>, the Fluke Calibration 9132 combines excellent portability with reliable infrared calibration performance. Additional features include RS-232 communication, a 0.1 \u00b0C temperature resolution and fast heating and cooling.<\/p>\n","protected":false},"featured_media":3476,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[56,53],"product_tag":[6056,6057,5906,6058,6059,6060,6061,6062,5910,5911,5912,5926,5913,3922,5916,6063,5918,4000,4001],"class_list":["post-6832","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-infrared-calibrators","product_cat-temperature","product_tag-57-mm-zieloberflaeche","product_tag-9132-infrarotkalibrator","product_tag-5906","product_tag-beruehrungslose-temperaturkalibrierung","product_tag-blackbody-kalibrator","product_tag-emissivitaet-0","product_tag-fluke-9132","product_tag-fluke-calibration-9132","product_tag-infrarotkalibrator","product_tag-infrarotthermometer-kalibrieren","product_tag-ir-kalibrator","product_tag-ir-kalibrator-500-c","product_tag-ir-thermometer-kalibrieren","product_tag-kalibrierlabor","product_tag-pyrometer-kalibrator","product_tag-schwarzkoerperquelle","product_tag-schwarzkoerperstrahler","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","pa_bauart-tisch","pa_genauigkeit-040c","pa_messbereich-500c","pa_schnittstelle-rs232","pa_stabilitaet--0-2-c","pa_strom-versorgung-230v","pa_temperaturbereich-35-c-bis-500-c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6832","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3476"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6832"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6832"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6832"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6832"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}