{"id":6844,"date":"2026-07-17T16:51:35","date_gmt":"2026-07-17T16:51:35","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-9150\/"},"modified":"2026-10-12T11:40:10","modified_gmt":"2026-10-12T11:40:10","slug":"fluke-calibration-9150","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-9150\/","title":{"rendered":"Fluke Calibration 9150 Portable Thermocouple Furnace"},"content":{"rendered":"<p>The <strong>Fluke Calibration 9150<\/strong> is a portable thermocouple furnace designed for reliable and efficient temperature calibration at elevated temperatures. With an operating range from <strong>150 \u00b0C to 1200 \u00b0C<\/strong>, the instrument provides a practical solution for calibrating industrial thermocouples in laboratories, production facilities and maintenance departments.<\/p>\n<p>The Fluke Calibration 9150 combines a wide temperature range with excellent temperature stability, interchangeable calibration inserts and microprocessor controlled temperature regulation.<\/p>\n<p>Its temperature stability of <strong>\u00b10.5 \u00b0C<\/strong> supports reproducible calibration conditions throughout the specified operating range. The integrated temperature display provides an accuracy of <strong>\u00b15 \u00b0C<\/strong>, while the interchangeable ceramic inserts allow thermocouples with different diameters to be accommodated.<\/p>\n<p>The furnace is particularly suitable for industrial applications requiring thermocouple calibration at temperatures significantly above the operating range of conventional portable dry block calibrators.<\/p>\n<p>With a heating time of approximately 35 minutes to reach 1200 \u00b0C, the Fluke Calibration 9150 offers efficient temperature calibration for industrial and laboratory applications.<\/p>\n<p>An integrated RS232 communication interface enables connection to a computer for remote control and integration into automated calibration procedures.<\/p>\n<p>The Fluke Calibration 9150 is supplied with NIST traceable calibration data, providing documented metrological traceability.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, reference thermometers and suitable calibration solutions.<\/p>\n<p>For information about professional calibration services, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Temperature range from 150 \u00b0C to 1200 \u00b0C<\/li>\n<li>Temperature stability of \u00b10.5 \u00b0C<\/li>\n<li>Display accuracy of \u00b15 \u00b0C<\/li>\n<li>Temperature resolution of 0.1 \u00b0C below 1000 \u00b0C<\/li>\n<li>Temperature resolution of 1 \u00b0C above 1000 \u00b0C<\/li>\n<li>Interchangeable ceramic calibration inserts<\/li>\n<li>Suitable for thermocouples with different diameters<\/li>\n<li>Calibration well diameter of 32 mm<\/li>\n<li>Total calibration well depth of approximately 140 mm<\/li>\n<li>Heating time of approximately 35 minutes to 1200 \u00b0C<\/li>\n<li>Well to well uniformity of \u00b12.5 \u00b0C under specified conditions<\/li>\n<li>Microprocessor controlled temperature regulation<\/li>\n<li>RS232 communication interface<\/li>\n<li>NIST traceable calibration included<\/li>\n<li>Compact construction for laboratory and industrial applications<\/li>\n<li>Suitable for high temperature thermocouple calibration<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p>The Fluke Calibration 9150 is designed for applications requiring a stable and reproducible temperature source at elevated temperatures.<\/p>\n<p>Thermocouples are widely used in industrial processes because they provide a broad operating temperature range and are suitable for demanding measurement environments.<\/p>\n<p>Typical applications include industrial furnaces, heat treatment systems, thermal processing equipment, manufacturing plants and research laboratories.<\/p>\n<p>Regular calibration is important for maintaining reliable temperature measurements and identifying changes in sensor performance.<\/p>\n<p>The Fluke Calibration 9150 provides a controlled temperature environment for comparing thermocouples with a suitable calibrated reference thermometer.<\/p>\n<p>The instrument is particularly useful for checking industrial thermocouples operating at temperatures between 150 \u00b0C and 1200 \u00b0C.<\/p>\n<p>Its interchangeable calibration inserts allow different sensor diameters to be accommodated without requiring a separate furnace for each sensor type.<\/p>\n<h2>Temperature Range from 150 \u00b0C to 1200 \u00b0C<\/h2>\n<p>The <strong>Fluke Calibration 9150<\/strong> provides a temperature range of:<\/p>\n<p><strong>150 \u00b0C to 1200 \u00b0C<\/strong><\/p>\n<p>This operating range makes the instrument particularly suitable for high temperature calibration applications.<\/p>\n<p>Many industrial thermocouples are used at temperatures exceeding 500 \u00b0C, where conventional low temperature calibration equipment is no longer suitable.<\/p>\n<p>The Fluke Calibration 9150 provides a practical calibration source for these applications.<\/p>\n<p>Typical calibration temperatures may include 200 \u00b0C, 400 \u00b0C, 600 \u00b0C, 800 \u00b0C, 1000 \u00b0C and 1200 \u00b0C.<\/p>\n<p>The selected calibration points should correspond to the operating range and application requirements of the thermocouple under test.<\/p>\n<p>The maximum permissible temperature of the sensor must always be considered.<\/p>\n<h2>Excellent Temperature Stability<\/h2>\n<p>Temperature stability is an important characteristic of a thermocouple calibration furnace.<\/p>\n<p>The Fluke Calibration 9150 provides a specified temperature stability of:<\/p>\n<p><strong>\u00b10.5 \u00b0C<\/strong><\/p>\n<p>This value applies throughout the specified operating range.<\/p>\n<p>Temperature stability describes fluctuations of the furnace temperature over time under defined operating conditions.<\/p>\n<p>Good stability helps maintain reproducible temperature conditions while calibration measurements are performed.<\/p>\n<p>However, temperature stability must not be confused with the accuracy of the furnace temperature indication.<\/p>\n<p>The overall measurement uncertainty also depends on temperature uniformity, reference thermometer uncertainty, immersion depth and the characteristics of the thermocouple under test.<\/p>\n<h2>Accurate Temperature Control<\/h2>\n<p>The Fluke Calibration 9150 uses a microprocessor based temperature controller.<\/p>\n<p>The controller regulates the furnace temperature according to the selected setpoint.<\/p>\n<p>The manufacturer specifies a display accuracy of:<\/p>\n<p><strong>\u00b15 \u00b0C<\/strong><\/p>\n<p>throughout the operating range.<\/p>\n<p>This specification describes the accuracy of the internal temperature indication.<\/p>\n<p>For calibration applications requiring lower measurement uncertainty, a suitable external reference thermometer should be used.<\/p>\n<p>The reference thermometer measures the actual temperature at the calibration position.<\/p>\n<p>The indication of the thermocouple under test can then be compared with the reference temperature.<\/p>\n<p>This comparison method helps reduce the influence of the furnace display error.<\/p>\n<h2>Temperature Resolution<\/h2>\n<p>The Fluke Calibration 9150 provides different temperature display resolutions depending on the selected temperature.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>0.1 \u00b0C up to 999.9 \u00b0C<\/strong><\/p>\n<p><strong>1 \u00b0C above 1000 \u00b0C<\/strong><\/p>\n<p>The display resolution determines the smallest temperature increment that can be displayed.<\/p>\n<p>It does not represent the measurement accuracy or measurement uncertainty of the instrument.<\/p>\n<p>The achievable calibration uncertainty depends on the complete measurement arrangement.<\/p>\n<h2>Interchangeable Calibration Inserts<\/h2>\n<p>One of the main advantages of the Fluke Calibration 9150 is its interchangeable calibration insert system.<\/p>\n<p>Different ceramic inserts are available for thermocouples with different diameters.<\/p>\n<p>The manufacturer offers four insert configurations.<\/p>\n<h3>Insert A<\/h3>\n<p>The Fluke Calibration 9150 Insert A is designed for thermocouples with different imperial diameters.<\/p>\n<p>It provides a selection of calibration openings suitable for various industrial temperature sensors.<\/p>\n<h3>Insert B<\/h3>\n<p>The Fluke Calibration 9150 Insert B is designed for comparison calibration applications.<\/p>\n<p>It provides several calibration openings that allow a reference thermometer and thermocouples under test to be positioned in the furnace.<\/p>\n<h3>Insert C<\/h3>\n<p>The Fluke Calibration 9150 Insert C features six calibration openings with a nominal diameter of:<\/p>\n<p><strong>6.35 mm<\/strong><\/p>\n<p>This insert is particularly suitable for calibrating several thermocouples with similar diameters.<\/p>\n<h3>Insert D<\/h3>\n<p>The Fluke Calibration 9150 Insert D provides six metric calibration openings.<\/p>\n<p>The configuration includes:<\/p>\n<ul>\n<li>Two openings with a diameter of 3 mm<\/li>\n<li>Two openings with a diameter of 4 mm<\/li>\n<li>Two openings with a diameter of 6 mm<\/li>\n<\/ul>\n<p>This configuration is particularly suitable for industrial thermocouples with metric sheath diameters.<\/p>\n<p>The appropriate insert should be selected according to the dimensions of the reference thermometer and the devices under test.<\/p>\n<h2>Calibration Well Diameter and Depth<\/h2>\n<p>The Fluke Calibration 9150 features a calibration well with a diameter of:<\/p>\n<p><strong>32 mm<\/strong><\/p>\n<p>The total well depth is approximately:<\/p>\n<p><strong>140 mm<\/strong><\/p>\n<p>This consists of a removable insert with a length of approximately 101 mm and an additional insulating section of approximately 38 mm.<\/p>\n<p>The available immersion depth is an important factor in thermocouple calibration.<\/p>\n<p>Insufficient immersion can cause heat conduction along the thermocouple sheath.<\/p>\n<p>This may result in a temperature difference between the measuring junction and the reference temperature.<\/p>\n<p>For accurate calibration, the thermocouple measuring junction should be positioned in a suitable region of the furnace.<\/p>\n<p>The required immersion depth depends on sensor construction, sheath diameter, thermocouple type and calibration temperature.<\/p>\n<h2>Temperature Uniformity<\/h2>\n<p>Temperature uniformity is particularly important when several thermocouples are calibrated simultaneously.<\/p>\n<p>The Fluke Calibration 9150 provides a specified well to well temperature uniformity of:<\/p>\n<p><strong>\u00b12.5 \u00b0C<\/strong><\/p>\n<p>This value applies to Insert C at a temperature of 1200 \u00b0C under the manufacturer&#8217;s specified conditions.<\/p>\n<p>Temperature uniformity describes differences between measurement positions within the calibration insert.<\/p>\n<p>These differences can influence the results of comparison calibration.<\/p>\n<p>For demanding calibration applications, the temperature distribution should be evaluated as part of the measurement uncertainty budget.<\/p>\n<p>The reference thermometer and thermocouple under test should be positioned at comparable immersion depths whenever possible.<\/p>\n<h2>Fast Heating Performance<\/h2>\n<p>The Fluke Calibration 9150 provides efficient heating performance for a high temperature calibration furnace.<\/p>\n<p>The manufacturer specifies a heating time of approximately:<\/p>\n<p><strong>35 minutes to 1200 \u00b0C<\/strong><\/p>\n<p>This allows high temperature calibration points to be reached without excessively long preparation times.<\/p>\n<p>The instrument also provides controlled cooling.<\/p>\n<p>The manufacturer specifies a cooling time of approximately:<\/p>\n<p><strong>140 minutes with the calibration block installed<\/strong><\/p>\n<p>The actual heating and cooling times depend on the initial temperature, ambient conditions and thermal loading.<\/p>\n<p>A stabilization time of approximately 20 minutes is specified.<\/p>\n<p>Sufficient stabilization time should be allowed before recording calibration measurements.<\/p>\n<h2>Thermocouple Calibration<\/h2>\n<p>The Fluke Calibration 9150 is designed primarily for calibrating thermocouples.<\/p>\n<p>Thermocouples generate a thermoelectric voltage that depends on the temperature difference between the measuring junction and the reference junction.<\/p>\n<p>During calibration, the thermocouple measuring junction is inserted into the calibration furnace.<\/p>\n<p>The furnace is adjusted to the required temperature.<\/p>\n<p>After stabilization, the thermoelectric voltage of the thermocouple is measured using a suitable electrical measuring instrument.<\/p>\n<p>The measured voltage is compared with the expected value for the corresponding thermocouple type.<\/p>\n<p>Alternatively, a temperature indicator can display the corresponding temperature directly.<\/p>\n<p>The indication error can be calculated as:<\/p>\n<p><strong>\u0394T = T_DUT \u2212 T_REF<\/strong><\/p>\n<p>Where:<\/p>\n<p><strong>\u0394T<\/strong> is the temperature indication error.<\/p>\n<p><strong>T_DUT<\/strong> is the temperature indicated by the device under test.<\/p>\n<p><strong>T_REF<\/strong> is the reference temperature.<\/p>\n<p>For reliable calibration results, the reference junction temperature and its compensation must also be considered.<\/p>\n<h2>Calibration of Different Thermocouple Types<\/h2>\n<p>The Fluke Calibration 9150 can be used for different thermocouple types, provided their specified temperature ranges and mechanical dimensions are suitable.<\/p>\n<p>Common industrial thermocouples include Type K, Type N, Type J, Type S, Type R and Type B.<\/p>\n<p>The appropriate thermocouple type depends on the application temperature, required accuracy and environmental conditions.<\/p>\n<p>For example, Type K and Type N thermocouples are widely used in industrial temperature measurement.<\/p>\n<p>Noble metal thermocouples such as Type S and Type R are commonly used for elevated temperature applications.<\/p>\n<p>The Fluke Calibration 9150 provides a suitable high temperature source for comparison calibration of compatible thermocouples.<\/p>\n<p>The actual measurement uncertainty depends on the thermocouple type, reference thermometer, furnace uniformity and measurement conditions.<\/p>\n<h2>Reference Thermometer Comparison<\/h2>\n<p>For applications requiring low measurement uncertainty, the Fluke Calibration 9150 can be used with a suitable calibrated reference thermometer.<\/p>\n<p>The reference thermometer is inserted into an appropriate calibration opening.<\/p>\n<p>The thermocouple under test is positioned in a neighboring opening.<\/p>\n<p>After thermal stabilization, both instruments are measured.<\/p>\n<p>The temperature difference between the device under test and the reference thermometer is used to determine the calibration deviation.<\/p>\n<p>This comparison method is particularly useful because the internal furnace display accuracy of \u00b15 \u00b0C does not necessarily represent the temperature at the measuring junction.<\/p>\n<p>The reference thermometer must be suitable for the selected temperature range.<\/p>\n<p>For calibration temperatures approaching 1200 \u00b0C, a suitable high temperature reference thermocouple may be required.<\/p>\n<h2>RS232 Communication Interface<\/h2>\n<p>The Fluke Calibration 9150 features an integrated RS232 communication interface.<\/p>\n<p>This interface allows the furnace to communicate with a computer.<\/p>\n<p>It supports remote operation and integration into computer controlled calibration systems.<\/p>\n<p>The interface can be used to simplify repeated temperature calibration procedures.<\/p>\n<p>Automated control can improve consistency when several calibration temperatures must be reached.<\/p>\n<p>The required communication software and system compatibility should be checked for the intended application.<\/p>\n<h2>NIST Traceable Calibration<\/h2>\n<p>The Fluke Calibration 9150 is supplied with NIST traceable calibration documentation.<\/p>\n<p>The manufacturer specifies calibration data at the following temperatures:<\/p>\n<p><strong>150 \u00b0C, 300 \u00b0C, 450 \u00b0C, 600 \u00b0C, 800 \u00b0C, 1000 \u00b0C and 1200 \u00b0C<\/strong><\/p>\n<p>These calibration points cover the specified operating range of the furnace.<\/p>\n<p>The supplied calibration documentation provides metrological traceability.<\/p>\n<p>For applications requiring accredited calibration according to ISO\/IEC 17025, the available calibration options should be checked separately.<\/p>\n<p>NIST traceability does not automatically mean that an accredited calibration certificate is included.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 9150<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>9150<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Thermocouple Furnace<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>150 \u00b0C to 1200 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy<\/td>\n<td>\u00b15 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display resolution up to 999.9 \u00b0C<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display resolution above 1000 \u00b0C<\/td>\n<td>1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibration well diameter<\/td>\n<td>32 mm<\/td>\n<\/tr>\n<tr>\n<td>Total calibration well depth<\/td>\n<td>Approximately 140 mm<\/td>\n<\/tr>\n<tr>\n<td>Removable insert length<\/td>\n<td>Approximately 101 mm<\/td>\n<\/tr>\n<tr>\n<td>Additional insulating section<\/td>\n<td>Approximately 38 mm<\/td>\n<\/tr>\n<tr>\n<td>Well to well uniformity<\/td>\n<td>\u00b12.5 \u00b0C with Insert C at 1200 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Heating time to 1200 \u00b0C<\/td>\n<td>Approximately 35 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time with block<\/td>\n<td>Approximately 140 minutes<\/td>\n<\/tr>\n<tr>\n<td>Stabilization time<\/td>\n<td>Approximately 20 minutes<\/td>\n<\/tr>\n<tr>\n<td>Calibration inserts<\/td>\n<td>A, B, C or D<\/td>\n<\/tr>\n<tr>\n<td>Temperature control<\/td>\n<td>Microprocessor controlled<\/td>\n<\/tr>\n<tr>\n<td>Communication interface<\/td>\n<td>RS232<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>115 V or 230 V AC, switchable<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>50 \/ 60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>1200 W<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>315 \u00d7 208 \u00d7 315 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approximately 13 kg<\/td>\n<\/tr>\n<tr>\n<td>Calibration documentation<\/td>\n<td>NIST traceable calibration included<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 9150 or Fluke Calibration 9144?<\/h2>\n<p>The Fluke Calibration 9150 and Fluke Calibration 9144 are designed for different temperature calibration requirements.<\/p>\n<p>The Fluke Calibration 9150 is a thermocouple furnace with a temperature range from 150 \u00b0C to 1200 \u00b0C.<\/p>\n<p>The Fluke Calibration 9144 is a field metrology well with a temperature range from 50 \u00b0C to 660 \u00b0C.<\/p>\n<p>The Fluke Calibration 9150 is particularly suitable for high temperature thermocouple calibration.<\/p>\n<p>The Fluke Calibration 9144 provides higher temperature stability and better characterized thermal performance within its lower operating range.<\/p>\n<p>The Fluke Calibration 9144 is also available with optional integrated process measurement electronics.<\/p>\n<p>The Fluke Calibration 9150 focuses on providing a practical and economical high temperature source for thermocouple calibration.<\/p>\n<p>The appropriate instrument depends on the required temperature range, sensor dimensions and measurement uncertainty requirements.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable temperature measurements.<\/p>\n<p>europascal supports customers with professional calibration services for temperature measuring instruments and temperature calibration equipment.<\/p>\n<p>For thermocouple calibration, the reference temperature, thermoelectric voltage measurement and reference junction compensation must be considered.<\/p>\n<p>The measurement uncertainty also depends on the furnace temperature stability, temperature uniformity, reference thermometer and immersion depth.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p>europascal also supports customers in selecting suitable temperature calibration equipment, reference thermometers and accessories.<\/p>\n<h2>Why Choose the Fluke Calibration 9150?<\/h2>\n<p>The Fluke Calibration 9150 combines a wide temperature range with reliable temperature control and a practical interchangeable insert system.<\/p>\n<p>Its temperature range from 150 \u00b0C to 1200 \u00b0C makes it particularly suitable for industrial thermocouple calibration.<\/p>\n<p>Temperature stability of \u00b10.5 \u00b0C supports reproducible calibration conditions throughout the operating range.<\/p>\n<p>The microprocessor controlled temperature regulation provides stable temperature control.<\/p>\n<p>Interchangeable ceramic inserts allow thermocouples with different diameters to be accommodated.<\/p>\n<p>The instrument can reach 1200 \u00b0C in approximately 35 minutes, making it suitable for calibration procedures involving elevated temperatures.<\/p>\n<p>The RS232 communication interface provides additional flexibility for automated calibration applications.<\/p>\n<p>With a weight of approximately 13 kg, the Fluke Calibration 9150 is suitable for laboratory use and transport between calibration locations.<\/p>\n<p>The included NIST traceable calibration documentation supports metrological traceability.<\/p>\n<p>For industrial users and calibration laboratories requiring a practical thermocouple calibration furnace, the Fluke Calibration 9150 offers an effective combination of temperature range, stability and versatility.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Calibration Applications with the Fluke Calibration 9150<\/h2>\n<p>The Fluke Calibration 9150 is suitable for calibrating industrial thermocouples used in high temperature applications.<\/p>\n<p>Typical applications include industrial furnaces, heat treatment processes, thermal processing equipment, manufacturing plants, quality assurance departments and calibration laboratories.<\/p>\n<p>The combination of a wide temperature range, interchangeable calibration inserts, microprocessor controlled temperature regulation and RS232 communication makes the Fluke Calibration 9150 a versatile solution for professional thermocouple calibration.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Weitere Produkte von Fluke Calibration finden Sie hier.<\/a><\/p>\n<p>Herstellerinformationen zum Fluke Calibration 9150 finden Sie auf der <a href=\"https:\/\/www.fluke.com\/en\/product\/calibration-tools\/temperature-calibrators\/fluke-calibration-9150\" target=\"_blank\" rel=\"noopener\">offiziellen Webseite von Fluke Calibration<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-Temperaturkalibrierung-Anwendungen-und-L\u00f6sungen.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 9150<\/strong> is a portable thermocouple furnace designed for temperature calibration from <strong>150 \u00b0C to 1200 \u00b0C<\/strong>. Featuring temperature stability of <strong>\u00b10.5 \u00b0C<\/strong>, display accuracy of <strong>\u00b15 \u00b0C<\/strong> and interchangeable ceramic calibration inserts, the instrument is ideal for calibrating industrial thermocouples at elevated temperatures. The Fluke Calibration 9150 heats to 1200 \u00b0C in approximately 35 minutes and features a 32 mm calibration well, microprocessor controlled temperature regulation and an RS232 communication interface.\u00a0With a weight of approximately 13 kg and NIST traceable calibration included, the Fluke Calibration 9150 provides a practical solution for industrial and laboratory thermocouple calibration.<\/p>\n","protected":false},"featured_media":3494,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[1206,53],"product_tag":[6099,6100,6101,5010,6102,6103,3922,4041,6052,6104,4001,4003,4004,6105,6106,6107],"class_list":["post-6844","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-alumina-einsatz","product_tag-fluke-9150","product_tag-fluke-calibration-9150","product_tag-hochtemperatur-kalibrator","product_tag-hochtemperatur-referenz","product_tag-hochtemperaturofen","product_tag-kalibrierlabor","product_tag-kalibrierofen","product_tag-rs232-temperaturkalibrator","product_tag-temperaturkalibrierung-1200-c","product_tag-temperaturmesstechnik","product_tag-thermoelement-kalibrieren","product_tag-thermoelement-kalibrierofen","product_tag-thermoelementofen","product_tag-trockenblock-1200-c","product_tag-waermebehandlung","pa_bauart-tisch","pa_funktion-nur-heizen","pa_genauigkeit-025-c","pa_kanaele-integrierte-zweikanalanzeige-fuer-prt-rtd-thermoelemente-4-20-ma-strom","pa_messbereich-450c","pa_schnittstelle-rs232","pa_stabilitaet-003-c","pa_strom-versorgung-230-v","pa_temperaturbereich-35c-bis-425c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6844","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3494"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6844"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6844"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6844"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}