{"id":6848,"date":"2026-07-17T16:51:15","date_gmt":"2026-07-17T16:51:15","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-9170\/"},"modified":"2026-10-12T11:47:55","modified_gmt":"2026-10-12T11:47:55","slug":"fluke-calibration-9170","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-9170\/","title":{"rendered":"Fluke Calibration 9170 Precise Metrology Well"},"content":{"rendered":"<p>The <strong>Fluke Calibration 9170<\/strong> is a high precision metrology well designed for accurate temperature calibration in professional calibration laboratories, industrial facilities and demanding field applications.<\/p>\n<p>With a temperature range from <strong>\u221245 \u00b0C to +140 \u00b0C<\/strong>, exceptional temperature stability of <strong>\u00b10.005 \u00b0C<\/strong> and a calibrated display accuracy of <strong>\u00b10.1 \u00b0C<\/strong>, the Fluke Calibration 9170 provides an excellent solution for calibrating platinum resistance thermometers, resistance temperature detectors, thermistors and other compatible temperature sensors.<\/p>\n<p>The instrument combines the convenience of a portable dry block calibrator with the advanced metrological performance required for demanding temperature calibration applications.<\/p>\n<p>Unlike conventional dry block calibrators, the Fluke Calibration 9170 is designed to minimize temperature gradients, loading effects and hysteresis.<\/p>\n<p>Its advanced temperature control technology provides stable and reproducible calibration conditions.<\/p>\n<p>The instrument features a calibration well depth of <strong>160 mm<\/strong>, helping reduce measurement errors caused by insufficient immersion.<\/p>\n<p>Excellent radial temperature uniformity of <strong>\u00b10.01 \u00b0C<\/strong> throughout the operating range makes the Fluke Calibration 9170 particularly suitable for comparison calibration.<\/p>\n<p>An optional integrated reference thermometer input allows direct measurement of compatible platinum resistance thermometers using ITS 90 coefficients.<\/p>\n<p>The Fluke Calibration 9170 also provides programmable calibration procedures, automatic temperature switch testing and an RS232 communication interface.<\/p>\n<p>These capabilities support efficient calibration workflows and integration into automated temperature calibration systems.<\/p>\n<p>europascal offers professional temperature calibration equipment, reference thermometers and technical support for demanding metrological applications.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Temperature range from \u221245 \u00b0C to +140 \u00b0C<\/li>\n<li>Exceptional temperature stability of \u00b10.005 \u00b0C<\/li>\n<li>Display accuracy of \u00b10.1 \u00b0C throughout the operating range<\/li>\n<li>Radial temperature uniformity of \u00b10.01 \u00b0C<\/li>\n<li>Excellent axial temperature uniformity<\/li>\n<li>Calibration well depth of 160 mm<\/li>\n<li>Temperature resolution of 0.001 \u00b0C<\/li>\n<li>Low loading effect under specified conditions<\/li>\n<li>Temperature hysteresis of 0.025 \u00b0C<\/li>\n<li>Optional integrated ITS 90 reference thermometer input<\/li>\n<li>Support for precision platinum resistance thermometers<\/li>\n<li>Interchangeable aluminum calibration inserts<\/li>\n<li>Six standard insert configurations<\/li>\n<li>Programmable temperature calibration procedures<\/li>\n<li>Automatic temperature switch testing<\/li>\n<li>RS232 communication interface<\/li>\n<li>Compatible with MET\/TEMP II calibration software<\/li>\n<li>Compact construction for laboratory and field applications<\/li>\n<li>Suitable for low temperature calibration<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p>The Fluke Calibration 9170 is designed for applications requiring excellent temperature stability and well-characterized thermal performance.<\/p>\n<p>Accurate temperature measurements are essential in pharmaceutical production, laboratory testing, industrial manufacturing and quality assurance.<\/p>\n<p>Temperature sensors used in these environments must be calibrated regularly to maintain reliable measurement results.<\/p>\n<p>The Fluke Calibration 9170 provides a controlled temperature environment for comparison calibration of temperature sensors.<\/p>\n<p>Its operating range from \u221245 \u00b0C to +140 \u00b0C covers many important low and medium temperature applications.<\/p>\n<p>The instrument is particularly suitable for calibrating platinum resistance thermometers used in laboratories and industrial measurement systems.<\/p>\n<p>It can also be used for evaluating temperature sensors installed in refrigeration systems, environmental chambers and process equipment.<\/p>\n<p>For demanding calibration applications, an external calibrated reference thermometer can be used to determine the actual temperature inside the calibration well.<\/p>\n<p>This helps reduce uncertainty contributions associated with the internal temperature indication.<\/p>\n<h2>Temperature Range from \u221245 \u00b0C to +140 \u00b0C<\/h2>\n<p>The <strong>Fluke Calibration 9170<\/strong> provides a temperature range of:<\/p>\n<p><strong>\u221245 \u00b0C to +140 \u00b0C<\/strong><\/p>\n<p>The specified range applies at an ambient temperature of 23 \u00b0C.<\/p>\n<p>This makes the instrument particularly suitable for calibration applications requiring temperatures below ambient conditions.<\/p>\n<p>Typical applications include refrigeration systems, temperature chambers, laboratory equipment and industrial temperature monitoring.<\/p>\n<p>The instrument can also generate calibration temperatures above ambient temperature up to +140 \u00b0C.<\/p>\n<p>This broad operating range allows multiple calibration points to be covered using a single temperature source.<\/p>\n<p>The actual calibration procedure should be selected according to the operating range and measurement uncertainty requirements of the device under test.<\/p>\n<h2>Exceptional Temperature Stability<\/h2>\n<p>Temperature stability is one of the most important characteristics of a precision temperature calibrator.<\/p>\n<p>The Fluke Calibration 9170 provides:<\/p>\n<p><strong>\u00b10.005 \u00b0C throughout the operating range<\/strong><\/p>\n<p>This corresponds to a stability specification of only five millikelvin.<\/p>\n<p>Temperature stability describes the temporal fluctuations of the calibration source under defined operating conditions.<\/p>\n<p>Excellent stability helps maintain constant temperature conditions during calibration measurements.<\/p>\n<p>This is particularly important when calibrating high accuracy resistance thermometers.<\/p>\n<p>However, temperature stability must not be confused with the display accuracy or the expanded measurement uncertainty of a calibration.<\/p>\n<h2>Accurate Temperature Indication<\/h2>\n<p>The Fluke Calibration 9170 features a calibrated temperature display.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Display accuracy: \u00b10.1 \u00b0C<\/strong><\/p>\n<p>This specification applies throughout the operating range.<\/p>\n<p>The internal temperature indication can be used for applications where its accuracy is sufficient.<\/p>\n<p>For demanding comparison calibrations, a calibrated external reference thermometer is recommended.<\/p>\n<p>The reference thermometer measures the temperature at the calibration position.<\/p>\n<p>The temperature indicated by the device under test can then be compared with the reference temperature.<\/p>\n<p>The resulting measurement uncertainty depends on the reference thermometer, thermal conditions and calibration procedure.<\/p>\n<h2>Excellent Axial Temperature Uniformity<\/h2>\n<p>The Fluke Calibration 9170 provides well-characterized axial temperature uniformity.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.1 \u00b0C at \u221245 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.04 \u00b0C at \u221235 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.02 \u00b0C at 0 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.07 \u00b0C at +140 \u00b0C<\/strong><\/p>\n<p>Axial temperature uniformity describes temperature differences along the vertical direction of the calibration well.<\/p>\n<p>Temperature gradients can influence calibration results when sensors have different immersion depths or sensing element positions.<\/p>\n<p>The Fluke Calibration 9170 is designed to minimize these effects.<\/p>\n<p>For accurate comparison calibration, the reference thermometer and device under test should be positioned at suitable and comparable immersion depths.<\/p>\n<h2>Excellent Radial Temperature Uniformity<\/h2>\n<p>The Fluke Calibration 9170 provides exceptional radial temperature uniformity.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.01 \u00b0C throughout the operating range<\/strong><\/p>\n<p>Radial uniformity describes temperature differences between measurement positions within the calibration insert.<\/p>\n<p>Good radial uniformity is particularly important when several temperature sensors are calibrated simultaneously.<\/p>\n<p>It helps ensure that the reference thermometer and devices under test are exposed to similar temperatures.<\/p>\n<p>The actual temperature distribution depends on the calibration insert, probe dimensions and thermal loading.<\/p>\n<h2>Low Temperature Loading Effect<\/h2>\n<p>The Fluke Calibration 9170 provides a low temperature loading effect.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.02 \u00b0C at \u221245 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.005 \u00b0C at \u221235 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.01 \u00b0C at +140 \u00b0C<\/strong><\/p>\n<p>These specifications apply under defined conditions using one 6.35 mm reference thermometer and three additional 6.35 mm probes.<\/p>\n<p>The loading effect describes changes in the calibration source temperature caused by inserting additional sensors.<\/p>\n<p>Low loading effects are important for comparison calibration because several sensors may be inserted into the calibration block simultaneously.<\/p>\n<p>The Fluke Calibration 9170 helps maintain stable temperature conditions under the specified loading conditions.<\/p>\n<h2>Temperature Hysteresis<\/h2>\n<p>Temperature hysteresis is another important characteristic of a precision metrology well.<\/p>\n<p>The Fluke Calibration 9170 has a specified hysteresis value of:<\/p>\n<p><strong>0.025 \u00b0C<\/strong><\/p>\n<p>Hysteresis describes differences in temperature indication depending on whether a calibration temperature is approached from a higher or lower temperature.<\/p>\n<p>This effect can contribute to the measurement uncertainty.<\/p>\n<p>The Fluke Calibration 9170 is designed to minimize hysteresis and provide reproducible calibration conditions.<\/p>\n<h2>Calibration Well Depth of 160 mm<\/h2>\n<p>The Fluke Calibration 9170 features a calibration well depth of:<\/p>\n<p><strong>160 mm<\/strong><\/p>\n<p>Sufficient immersion depth is particularly important when calibrating resistance thermometers.<\/p>\n<p>Heat conduction along the thermometer stem can cause differences between the sensing element temperature and the temperature of the calibration block.<\/p>\n<p>The relatively deep calibration well helps reduce these effects.<\/p>\n<p>The required immersion depth depends on the sensor construction, diameter, sensing element length and calibration temperature.<\/p>\n<p>For demanding calibration applications, the influence of immersion depth should be evaluated as part of the measurement uncertainty budget.<\/p>\n<h2>Temperature Resolution of 0.001 \u00b0C<\/h2>\n<p>The Fluke Calibration 9170 provides a temperature display resolution of:<\/p>\n<p><strong>0.001 \u00b0C<\/strong><\/p>\n<p>This corresponds to one millikelvin.<\/p>\n<p>The fine display resolution allows small temperature changes to be observed.<\/p>\n<p>It is particularly useful when monitoring temperature stability and performing precision comparison measurements.<\/p>\n<p>Display resolution must not be confused with temperature accuracy or measurement uncertainty.<\/p>\n<h2>Heating and Cooling Performance<\/h2>\n<p>The Fluke Calibration 9170 provides efficient heating and cooling performance.<\/p>\n<p>The manufacturer specifies the following typical times.<\/p>\n<p><strong>Cooling from 23 \u00b0C to \u221245 \u00b0C: 44 minutes<\/strong><\/p>\n<p><strong>Cooling from 23 \u00b0C to \u221230 \u00b0C: 19 minutes<\/strong><\/p>\n<p><strong>Cooling from 140 \u00b0C to 23 \u00b0C: 19 minutes<\/strong><\/p>\n<p><strong>Heating from 23 \u00b0C to 140 \u00b0C: 32 minutes<\/strong><\/p>\n<p><strong>Heating from \u221245 \u00b0C to 140 \u00b0C: 45 minutes<\/strong><\/p>\n<p>These characteristics support calibration procedures involving multiple temperature points.<\/p>\n<p>Actual heating and cooling times depend on operating conditions and thermal loading.<\/p>\n<h2>Interchangeable Calibration Inserts<\/h2>\n<p>The Fluke Calibration 9170 uses interchangeable aluminum calibration inserts.<\/p>\n<p>Different insert configurations are available for temperature sensors with different diameters.<\/p>\n<p>The manufacturer offers six standard configurations.<\/p>\n<p><strong>Insert A:<\/strong> Mixed imperial calibration openings.<\/p>\n<p><strong>Insert B:<\/strong> Imperial comparison openings.<\/p>\n<p><strong>Insert C:<\/strong> Six openings with a diameter of 6.35 mm.<\/p>\n<p><strong>Insert D:<\/strong> Metric comparison openings.<\/p>\n<p><strong>Insert E:<\/strong> Mixed metric openings with an additional 6.35 mm reference opening.<\/p>\n<p><strong>Insert F:<\/strong> Metric comparison openings with an additional 6.35 mm reference opening.<\/p>\n<p>A blank insert is also available for customized applications.<\/p>\n<p>The appropriate insert should be selected according to the dimensions of the reference thermometer and the devices under test.<\/p>\n<p>A suitable fit between the sensor and insert helps improve thermal contact.<\/p>\n<h2>Optional Integrated Reference Thermometer Input<\/h2>\n<p>The Fluke Calibration 9170 is available with an optional integrated reference thermometer input.<\/p>\n<p>These versions are identified by the additional <strong>R<\/strong> in the model designation.<\/p>\n<p>For example:<\/p>\n<p><strong>Fluke Calibration 9170-A-R<\/strong><\/p>\n<p>The integrated reference input supports compatible platinum resistance thermometers.<\/p>\n<p>It allows reference temperature measurements using ITS 90 coefficients.<\/p>\n<p>The manufacturer specifies reference readout accuracy down to:<\/p>\n<p><strong>\u00b10.006 \u00b0C<\/strong><\/p>\n<p>under the applicable measurement conditions.<\/p>\n<p>This specification describes the performance of the integrated reference thermometer readout.<\/p>\n<p>It does not include the calibration uncertainty of the connected reference thermometer.<\/p>\n<p>The total measurement uncertainty depends on the readout, reference thermometer and calibration conditions.<\/p>\n<h2>Platinum Resistance Thermometer Calibration<\/h2>\n<p>The Fluke Calibration 9170 is particularly suitable for calibrating platinum resistance thermometers.<\/p>\n<p>Typical applications include Pt100 sensors, precision platinum resistance thermometers and compatible reference thermometers.<\/p>\n<p>The sensor under test is inserted into a suitable calibration opening.<\/p>\n<p>A calibrated reference thermometer is positioned in another opening.<\/p>\n<p>After thermal stabilization, the temperature indications are compared.<\/p>\n<p>The indication error can be calculated as:<\/p>\n<p><strong>\u0394T = T_DUT \u2212 T_REF<\/strong><\/p>\n<p>Where:<\/p>\n<p><strong>\u0394T<\/strong> is the temperature indication error.<\/p>\n<p><strong>T_DUT<\/strong> is the temperature indicated by the device under test.<\/p>\n<p><strong>T_REF<\/strong> is the reference temperature.<\/p>\n<p>The measurement uncertainty depends on the reference thermometer, thermal uniformity, stability, loading effect and immersion depth.<\/p>\n<h2>Automated Calibration Procedures<\/h2>\n<p>The Fluke Calibration 9170 includes programmable calibration functions.<\/p>\n<p>The instrument supports:<\/p>\n<p><strong>Four programmable calibration procedures<\/strong><\/p>\n<p>Each procedure can contain up to:<\/p>\n<p><strong>Eight temperature setpoints<\/strong><\/p>\n<p>Individual ramp and hold times can be configured.<\/p>\n<p>These functions help simplify repeated calibration procedures.<\/p>\n<p>The instrument can automatically move between predefined temperature setpoints without requiring continuous manual adjustment.<\/p>\n<p>This is particularly useful when calibrating temperature sensors at several temperatures.<\/p>\n<h2>Automatic Temperature Switch Testing<\/h2>\n<p>The Fluke Calibration 9170 supports automatic temperature switch testing.<\/p>\n<p>The instrument can determine switching temperatures and the dead band of temperature switches.<\/p>\n<p>Temperature switches are widely used in industrial process control and safety systems.<\/p>\n<p>The automatic test function simplifies the determination of switching characteristics.<\/p>\n<p>This helps improve efficiency during routine maintenance and calibration procedures.<\/p>\n<h2>RS232 Communication and Automation<\/h2>\n<p>The Fluke Calibration 9170 features an integrated RS232 communication interface.<\/p>\n<p>This allows the instrument to communicate with a computer or compatible calibration software.<\/p>\n<p>The manufacturer specifies compatibility with MET\/TEMP II software.<\/p>\n<p>This enables automated calibration procedures for resistance thermometers, thermocouples and thermistors.<\/p>\n<p>Automated calibration can help reduce manual work and improve the consistency of repeated measurements.<\/p>\n<p>The instrument can also be operated independently without a computer.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 9170<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>9170<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Metrology Well<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u221245 \u00b0C to +140 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Reference ambient temperature<\/td>\n<td>23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.005 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity at \u221245 \u00b0C<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity at \u221235 \u00b0C<\/td>\n<td>\u00b10.04 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity at 0 \u00b0C<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity at 140 \u00b0C<\/td>\n<td>\u00b10.07 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial uniformity<\/td>\n<td>\u00b10.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Loading effect at \u221245 \u00b0C<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Loading effect at \u221235 \u00b0C<\/td>\n<td>\u00b10.005 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Loading effect at 140 \u00b0C<\/td>\n<td>\u00b10.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Hysteresis<\/td>\n<td>0.025 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature resolution<\/td>\n<td>0.001 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibration well depth<\/td>\n<td>160 mm<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, 23 \u00b0C to \u221245 \u00b0C<\/td>\n<td>44 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, 23 \u00b0C to \u221230 \u00b0C<\/td>\n<td>19 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, 140 \u00b0C to 23 \u00b0C<\/td>\n<td>19 minutes<\/td>\n<\/tr>\n<tr>\n<td>Heating time, 23 \u00b0C to 140 \u00b0C<\/td>\n<td>32 minutes<\/td>\n<\/tr>\n<tr>\n<td>Heating time, \u221245 \u00b0C to 140 \u00b0C<\/td>\n<td>45 minutes<\/td>\n<\/tr>\n<tr>\n<td>Calibration inserts<\/td>\n<td>A, B, C, D, E, F<\/td>\n<\/tr>\n<tr>\n<td>Optional reference input<\/td>\n<td>Available<\/td>\n<\/tr>\n<tr>\n<td>Reference readout accuracy<\/td>\n<td>Down to \u00b10.006 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Programmable procedures<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Setpoints per procedure<\/td>\n<td>Up to 8<\/td>\n<\/tr>\n<tr>\n<td>Temperature switch testing<\/td>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<td>Communication interface<\/td>\n<td>RS232<\/td>\n<\/tr>\n<tr>\n<td>Compatible software<\/td>\n<td>MET\/TEMP II<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>366 \u00d7 203 \u00d7 323 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 9170 or Fluke Calibration 9142?<\/h2>\n<p>The Fluke Calibration 9170 and Fluke Calibration 9142 are designed for professional temperature calibration applications.<\/p>\n<p>However, they differ in temperature range and metrological performance.<\/p>\n<p>The Fluke Calibration 9170 operates from \u221245 \u00b0C to +140 \u00b0C.<\/p>\n<p>The Fluke Calibration 9142 operates from \u221225 \u00b0C to +150 \u00b0C.<\/p>\n<p>The Fluke Calibration 9170 provides temperature stability of \u00b10.005 \u00b0C throughout its operating range.<\/p>\n<p>The Fluke Calibration 9142 provides temperature stability of \u00b10.01 \u00b0C.<\/p>\n<p>The Fluke Calibration 9170 is particularly suitable for demanding low temperature calibration applications requiring excellent temperature stability and low measurement uncertainty.<\/p>\n<p>The Fluke Calibration 9142 offers a compact field calibration solution with optional integrated process measurement electronics.<\/p>\n<p>The appropriate instrument depends on the required temperature range, measurement uncertainty and application requirements.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and calibration equipment.<\/p>\n<p>When calibrating a metrology well, several characteristics must be considered.<\/p>\n<p>These include temperature indication error, stability, axial temperature uniformity, radial temperature uniformity, loading effects and hysteresis.<\/p>\n<p>The overall measurement uncertainty also depends on the reference thermometer and its calibration uncertainty.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p>europascal also supports customers in selecting suitable reference thermometers, calibration inserts and complete temperature calibration systems.<\/p>\n<h2>Why Choose the Fluke Calibration 9170?<\/h2>\n<p>The Fluke Calibration 9170 combines exceptional temperature stability with a wide low temperature operating range and excellent thermal uniformity.<\/p>\n<p>Its temperature range from \u221245 \u00b0C to +140 \u00b0C makes it suitable for numerous industrial and laboratory calibration applications.<\/p>\n<p>Temperature stability of \u00b10.005 \u00b0C provides reproducible calibration conditions.<\/p>\n<p>The calibrated temperature display offers an accuracy of \u00b10.1 \u00b0C throughout the operating range.<\/p>\n<p>Excellent radial temperature uniformity of \u00b10.01 \u00b0C supports accurate comparison calibration.<\/p>\n<p>The 160 mm calibration well depth helps reduce errors caused by insufficient immersion.<\/p>\n<p>Interchangeable calibration inserts allow different sensor diameters to be accommodated.<\/p>\n<p>The optional integrated reference thermometer input provides additional flexibility for high precision temperature measurements.<\/p>\n<p>Programmable calibration procedures, automatic temperature switch testing and RS232 communication support efficient calibration workflows.<\/p>\n<p>For professional calibration laboratories requiring excellent metrological performance at low temperatures, the Fluke Calibration 9170 provides a reliable and versatile solution.<\/p>\n<p>europascal supports customers with temperature calibration equipment, technical advice and professional calibration services.<\/p>\n<h2>Typical Calibration Applications with the Fluke Calibration 9170<\/h2>\n<p>The Fluke Calibration 9170 is suitable for calibrating platinum resistance thermometers, precision resistance thermometers, industrial RTDs, thermistors and other compatible temperature sensors.<\/p>\n<p>Typical applications include pharmaceutical production, laboratory temperature measurement, industrial process instrumentation, refrigeration systems, environmental chambers, quality assurance and calibration laboratories.<\/p>\n<p>The combination of excellent temperature stability, low temperature capability, well-characterized thermal uniformity and automated calibration functions makes the Fluke Calibration 9170 a professional solution for demanding temperature calibration applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Weitere Produkte von Fluke Calibration finden Sie hier.<\/a><\/p>\n<p>Herstellerinformationen zum Fluke Calibration 9170 finden Sie auf der <a href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/temperature-calibrators\/fluke-calibration-9170\" target=\"_blank\" rel=\"noopener\">offiziellen Webseite von Fluke Calibration<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-9170-Metrology-Well-Calibrators.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 9170<\/strong> is a high precision metrology well designed for temperature calibration from <strong>\u221245 \u00b0C to +140 \u00b0C<\/strong>. Featuring exceptional temperature stability of <strong>\u00b10.005 \u00b0C<\/strong>, display accuracy of <strong>\u00b10.1 \u00b0C<\/strong> and radial temperature uniformity of <strong>\u00b10.01 \u00b0C<\/strong>, the instrument is ideal for calibrating platinum resistance thermometers, RTDs and precision temperature sensors. The Fluke Calibration 9170 features a 160 mm calibration well, interchangeable aluminum inserts and a temperature resolution of 0.001 \u00b0C.\u00a0Optional integrated ITS 90 reference thermometer measurement, programmable calibration procedures and RS232 communication make the instrument suitable for demanding laboratory and industrial calibration applications.<\/p>\n","protected":false},"featured_media":3468,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[1206,53],"product_tag":[6035,6126,6127,6128,4095,3922,6129,6130,3994,3995,4110,6043,3998,3999,4000,4001,6015,4005],"class_list":["post-6848","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-blockkalibrator","product_tag-blockkalibrator-minus-45-c","product_tag-fluke-9170","product_tag-fluke-calibration-9170","product_tag-its-90","product_tag-kalibrierlabor","product_tag-metrologie-blockkalibrator","product_tag-metrology-well","product_tag-prt-kalibrieren","product_tag-pt100-kalibrieren","product_tag-referenzthermometer","product_tag-rtd-kalibrieren","product_tag-temperaturfuehler-kalibrieren","product_tag-temperaturkalibrator","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-thermistor-kalibrieren","product_tag-trockenblockkalibrator","pa_bauart-koffer","pa_funktion-heizen-kuehlen","pa_genauigkeit-heisser-block-06c-kalter-block-02c","pa_messbereich-minus-bis-375c","pa_schnittstelle-rs232","pa_stabilitaet-0-05c","pa_strom-versorgung-230-v","pa_temperaturbereich-15c-bis-350c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6848","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3468"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6848"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6848"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6848"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}