{"id":6854,"date":"2026-07-17T16:51:29","date_gmt":"2026-07-17T16:51:29","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-9173\/"},"modified":"2026-10-12T11:58:19","modified_gmt":"2026-10-12T11:58:19","slug":"fluke-calibration-9173","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-9173\/","title":{"rendered":"Fluke Calibration 9173 Precise Metrology Well"},"content":{"rendered":"<p>The <strong>Fluke Calibration 9173<\/strong> is a high precision metrology well designed for demanding temperature calibration applications at elevated temperatures. With a temperature range from <strong>+50 \u00b0C to +700 \u00b0C<\/strong>, excellent temperature stability and a deep calibration well, the instrument combines the convenience of a dry block calibrator with the metrological performance required in professional calibration laboratories.<\/p>\n<p>The Fluke Calibration 9173 is particularly suitable for comparison calibration of platinum resistance thermometers, industrial RTDs, thermocouples and other compatible temperature sensors.<\/p>\n<p>Temperature stability ranges from <strong>\u00b10.005 \u00b0C to \u00b10.03 \u00b0C<\/strong>, depending on the operating temperature. The calibrated internal display provides an accuracy ranging from <strong>\u00b10.1 \u00b0C to \u00b10.25 \u00b0C<\/strong>.<\/p>\n<p>A calibration well depth of <strong>203 mm<\/strong> provides excellent immersion conditions and helps reduce stem conduction errors. Carefully characterized axial and radial temperature uniformity further supports low uncertainty comparison measurements.<\/p>\n<p>An optional integrated reference thermometer input allows compatible reference PRTs to be connected directly to the Fluke Calibration 9173.<\/p>\n<p>Programmable calibration procedures, automatic temperature switch testing and an RS232 communication interface support efficient calibration workflows and automated applications.<\/p>\n<p>europascal provides professional temperature calibration equipment, reference thermometers and calibration solutions for laboratory and industrial applications.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Wide temperature range from +50 \u00b0C to +700 \u00b0C<\/li>\n<li>Temperature stability down to \u00b10.005 \u00b0C<\/li>\n<li>Display accuracy down to \u00b10.1 \u00b0C<\/li>\n<li>Excellent axial and radial temperature uniformity<\/li>\n<li>Deep 203 mm calibration well<\/li>\n<li>Temperature resolution of 0.001 \u00b0C<\/li>\n<li>Low temperature loading effect<\/li>\n<li>Interchangeable calibration inserts<\/li>\n<li>Suitable for PRTs, RTDs and thermocouples<\/li>\n<li>Optional integrated reference thermometer input<\/li>\n<li>ITS 90 and Callendar Van Dusen support with reference option<\/li>\n<li>Programmable calibration procedures<\/li>\n<li>Automatic temperature switch testing<\/li>\n<li>RS232 communication interface<\/li>\n<li>Suitable for automated calibration applications<\/li>\n<li>NIST traceable calibration supplied by the manufacturer<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p>The Fluke Calibration 9173 is designed for users who require more than a conventional industrial dry block calibrator.<\/p>\n<p>In precision temperature calibration, the performance of a heat source cannot be described by display accuracy alone. Temperature stability, axial gradients, radial uniformity, loading effects, hysteresis and immersion depth can all influence the calibration result.<\/p>\n<p>The Fluke Calibration 9173 is designed to minimize and characterize these important effects.<\/p>\n<p>This makes the instrument suitable for professional calibration laboratories, industrial quality assurance, manufacturing facilities, research laboratories and other applications requiring reliable temperature calibration at temperatures up to 700 \u00b0C.<\/p>\n<p>A calibrated reference thermometer can be positioned close to the device under test, allowing a direct comparison between both sensors.<\/p>\n<h2>Temperature Range from 50 \u00b0C to 700 \u00b0C<\/h2>\n<p>The <strong>Fluke Calibration 9173<\/strong> provides a temperature range of:<\/p>\n<p><strong>+50 \u00b0C to +700 \u00b0C<\/strong><\/p>\n<p>at a reference ambient temperature of 23 \u00b0C.<\/p>\n<p>This wide operating range makes the 9173 the highest temperature model in the Fluke Calibration 9170 Metrology Well series.<\/p>\n<p>It covers numerous industrial applications involving elevated temperatures.<\/p>\n<p>Typical calibration points can include 100 \u00b0C, 200 \u00b0C, 300 \u00b0C, 400 \u00b0C, 500 \u00b0C, 600 \u00b0C and 700 \u00b0C.<\/p>\n<p>The actual calibration points should be selected according to the operating range, sensor type and intended application of the device under test.<\/p>\n<h2>Excellent Temperature Stability<\/h2>\n<p>The Fluke Calibration 9173 provides excellent temperature stability across its operating range.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.005 \u00b0C from 50 \u00b0C to 100 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.01 \u00b0C from 100 \u00b0C to 300 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.02 \u00b0C from 300 \u00b0C to 500 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.03 \u00b0C from 500 \u00b0C to 700 \u00b0C<\/strong><\/p>\n<p>Temperature stability describes the variation of the calibration source temperature over time under defined operating conditions.<\/p>\n<p>Low temporal fluctuations are particularly important when performing comparison calibrations with high accuracy reference thermometers.<\/p>\n<p>The stability specification should not be confused with display accuracy or the expanded measurement uncertainty of the complete calibration.<\/p>\n<h2>Accurate Temperature Indication<\/h2>\n<p>The Fluke Calibration 9173 features a calibrated internal temperature display.<\/p>\n<p>The manufacturer specifies display accuracy of:<\/p>\n<p><strong>\u00b10.1 \u00b0C from 50 \u00b0C to 100 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.15 \u00b0C from 100 \u00b0C to 300 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.2 \u00b0C from 300 \u00b0C to 500 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.25 \u00b0C from 500 \u00b0C to 700 \u00b0C<\/strong><\/p>\n<p>For applications where these specifications are sufficient, the internal control sensor can be used as the temperature reference.<\/p>\n<p>For demanding comparison calibrations, an external calibrated reference thermometer is recommended.<\/p>\n<p>Using a reference thermometer positioned close to the device under test can significantly reduce the influence of the calibrator&#8217;s absolute display error on the calibration result.<\/p>\n<h2>Excellent Axial Temperature Uniformity<\/h2>\n<p>Axial temperature uniformity is an important characteristic of a precision calibration source.<\/p>\n<p>The Fluke Calibration 9173 provides well-characterized temperature gradients along the calibration zone.<\/p>\n<p>The manufacturer specifies axial uniformity over a 60 mm zone of:<\/p>\n<p><strong>\u00b10.05 \u00b0C from 50 \u00b0C to 100 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.1 \u00b0C from 100 \u00b0C to 300 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.2 \u00b0C from 300 \u00b0C to 500 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.4 \u00b0C from 500 \u00b0C to 700 \u00b0C<\/strong><\/p>\n<p>Axial gradients can cause measurement errors when the sensing elements of the reference thermometer and device under test are located at different depths.<\/p>\n<p>For precise comparison calibration, both sensing elements should therefore be positioned at comparable immersion depths.<\/p>\n<h2>Excellent Radial Temperature Uniformity<\/h2>\n<p>The Fluke Calibration 9173 also provides excellent radial temperature uniformity.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.01 \u00b0C from 50 \u00b0C to 100 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.02 \u00b0C from 100 \u00b0C to 300 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.04 \u00b0C from 300 \u00b0C to 500 \u00b0C<\/strong><\/p>\n<p><strong>\u00b10.07 \u00b0C from 500 \u00b0C to 700 \u00b0C<\/strong><\/p>\n<p>Radial uniformity describes temperature differences between different measurement positions at the same immersion depth.<\/p>\n<p>This characteristic is particularly important when a reference thermometer and one or more devices under test are inserted simultaneously.<\/p>\n<p>Good radial uniformity helps ensure that the connected sensors experience comparable temperatures.<\/p>\n<h2>Low Loading Effect<\/h2>\n<p>Inserting several probes into a dry block changes its thermal conditions.<\/p>\n<p>This effect is known as the loading effect.<\/p>\n<p>The Fluke Calibration 9173 is designed to minimize this influence.<\/p>\n<p>Low loading effects are particularly important when several temperature sensors are calibrated simultaneously.<\/p>\n<p>For demanding measurements, loading effects should be considered in the measurement uncertainty budget together with stability, axial gradients, radial uniformity and the uncertainty of the reference thermometer.<\/p>\n<h2>Deep 203 mm Calibration Well<\/h2>\n<p>One of the major advantages of the Fluke Calibration 9173 is its calibration well depth of:<\/p>\n<p><strong>203 mm<\/strong><\/p>\n<p>or approximately:<\/p>\n<p><strong>8 inches<\/strong><\/p>\n<p>A deep calibration well provides improved immersion conditions for temperature sensors.<\/p>\n<p>This is especially important at elevated temperatures because heat conduction along the probe stem can create significant measurement errors.<\/p>\n<p>The sensing element of the device under test must be immersed sufficiently deeply to reach thermal equilibrium with the calibration zone.<\/p>\n<p>The required immersion depth depends on sensor construction, diameter, thermal conductivity and operating temperature.<\/p>\n<p>The 203 mm well depth makes the Fluke Calibration 9173 particularly suitable for longer industrial probes and precision temperature sensors.<\/p>\n<h2>Temperature Resolution of 0.001 \u00b0C<\/h2>\n<p>The Fluke Calibration 9173 provides a temperature display resolution of:<\/p>\n<p><strong>0.001 \u00b0C<\/strong><\/p>\n<p>The fine resolution allows small temperature variations to be observed during stabilization.<\/p>\n<p>It is particularly useful when monitoring the thermal behavior of the calibration source during precision comparison measurements.<\/p>\n<p>Display resolution does not represent temperature accuracy or measurement uncertainty.<\/p>\n<h2>Interchangeable Calibration Inserts<\/h2>\n<p>The Fluke Calibration 9173 uses interchangeable calibration inserts.<\/p>\n<p>Different insert configurations allow the instrument to accommodate temperature probes with different diameters.<\/p>\n<p>Available configurations include imperial and metric hole patterns for reference thermometers and devices under test.<\/p>\n<p>A suitable insert should provide good thermal contact while still allowing the probe to be inserted and removed safely.<\/p>\n<p>The clearance between the probe and insert can influence thermal transfer and therefore the calibration result.<\/p>\n<p>Selecting the correct insert is consequently an important part of configuring the Fluke Calibration 9173 for a specific calibration application.<\/p>\n<h2>Optional Integrated Reference Thermometer Input<\/h2>\n<p>The Fluke Calibration 9173 is available with an optional integrated reference thermometer input.<\/p>\n<p>Versions equipped with this option are identified by an additional <strong>R<\/strong> in the model designation.<\/p>\n<p>The reference input allows compatible platinum resistance thermometers to be connected directly to the instrument.<\/p>\n<p>The system supports thermometer characterization using methods including:<\/p>\n<ul>\n<li>ITS 90 coefficients<\/li>\n<li>Callendar Van Dusen coefficients<\/li>\n<\/ul>\n<p>This makes it possible to use a calibrated PRT as the reference thermometer without requiring a separate external thermometer readout.<\/p>\n<p>The uncertainty of the connected reference thermometer itself must still be considered.<\/p>\n<p>The complete reference temperature uncertainty therefore depends on both the readout performance and the calibration uncertainty and stability of the connected thermometer.<\/p>\n<h2>PRT and RTD Calibration<\/h2>\n<p>The Fluke Calibration 9173 is particularly suitable for calibrating platinum resistance thermometers and industrial RTDs within their permissible operating ranges.<\/p>\n<p>During comparison calibration, the reference thermometer and device under test are inserted into suitable openings in the calibration block.<\/p>\n<p>After sufficient stabilization, both temperature values are recorded.<\/p>\n<p>The indication error can be calculated as:<\/p>\n<p><strong>\u0394T = T_DUT \u2212 T_REF<\/strong><\/p>\n<p>where:<\/p>\n<p><strong>\u0394T<\/strong> is the indication error,<\/p>\n<p><strong>T_DUT<\/strong> is the temperature indicated by the device under test,<\/p>\n<p>and<\/p>\n<p><strong>T_REF<\/strong> is the temperature determined by the reference thermometer.<\/p>\n<p>The measurement uncertainty should include all significant contributions from the reference thermometer, readout, calibration source and measurement procedure.<\/p>\n<h2>Thermocouple Calibration<\/h2>\n<p>The wide operating range up to 700 \u00b0C also makes the Fluke Calibration 9173 suitable for calibrating many industrial thermocouples.<\/p>\n<p>Thermocouples generate a thermoelectric voltage depending on the temperature difference between the measuring junction and the reference junction.<\/p>\n<p>During calibration, the measuring junction is positioned in the characterized calibration zone of the Fluke Calibration 9173.<\/p>\n<p>The thermocouple signal can then be measured with a suitable electrical measuring instrument.<\/p>\n<p>For accurate thermocouple calibration, cold junction compensation, thermoelectric voltage measurement, immersion depth and thermocouple homogeneity must be considered.<\/p>\n<p>The permissible operating temperature of the individual thermocouple must always be observed.<\/p>\n<h2>Programmable Calibration Procedures<\/h2>\n<p>The Fluke Calibration 9173 provides programmable calibration functions for repeated measurement procedures.<\/p>\n<p>The instrument supports:<\/p>\n<p><strong>Four programmable calibration procedures<\/strong><\/p>\n<p>with up to:<\/p>\n<p><strong>Eight temperature setpoints per procedure<\/strong><\/p>\n<p>This allows frequently used calibration sequences to be stored directly in the instrument.<\/p>\n<p>Temperature setpoints, ramp behavior and hold times can be configured according to the calibration procedure.<\/p>\n<p>Automated sequences reduce manual intervention and help improve the reproducibility of routine calibrations.<\/p>\n<h2>Automatic Temperature Switch Testing<\/h2>\n<p>The Fluke Calibration 9173 can also be used for automatic temperature switch testing.<\/p>\n<p>Temperature switches and thermostats are widely used in industrial control and safety applications.<\/p>\n<p>The calibration procedure can determine the switching point and hysteresis of a temperature switch.<\/p>\n<p>Automated testing simplifies repetitive measurements and helps reduce operator effort.<\/p>\n<h2>RS232 Communication and Automation<\/h2>\n<p>The Fluke Calibration 9173 features an integrated RS232 communication interface.<\/p>\n<p>This allows the instrument to be connected to a computer and integrated into automated calibration systems.<\/p>\n<p>Remote communication enables temperature setpoints and other instrument functions to be controlled automatically.<\/p>\n<p>The Fluke Calibration Metrology Well series can also be integrated into suitable temperature calibration workflows using compatible calibration software.<\/p>\n<p>This provides additional efficiency for laboratories performing repeated sensor calibrations.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 9173<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>9173<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Metrology Well<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>+50 \u00b0C to +700 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Reference ambient temperature<\/td>\n<td>23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy, 50 \u00b0C to 100 \u00b0C<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy, 100 \u00b0C to 300 \u00b0C<\/td>\n<td>\u00b10.15 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy, 300 \u00b0C to 500 \u00b0C<\/td>\n<td>\u00b10.2 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy, 500 \u00b0C to 700 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability, 50 \u00b0C to 100 \u00b0C<\/td>\n<td>\u00b10.005 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability, 100 \u00b0C to 300 \u00b0C<\/td>\n<td>\u00b10.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability, 300 \u00b0C to 500 \u00b0C<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability, 500 \u00b0C to 700 \u00b0C<\/td>\n<td>\u00b10.03 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity, 50 \u00b0C to 100 \u00b0C<\/td>\n<td>\u00b10.05 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity, 100 \u00b0C to 300 \u00b0C<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity, 300 \u00b0C to 500 \u00b0C<\/td>\n<td>\u00b10.2 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity, 500 \u00b0C to 700 \u00b0C<\/td>\n<td>\u00b10.4 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial uniformity, 50 \u00b0C to 100 \u00b0C<\/td>\n<td>\u00b10.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial uniformity, 100 \u00b0C to 300 \u00b0C<\/td>\n<td>\u00b10.02 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial uniformity, 300 \u00b0C to 500 \u00b0C<\/td>\n<td>\u00b10.04 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial uniformity, 500 \u00b0C to 700 \u00b0C<\/td>\n<td>\u00b10.07 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature resolution<\/td>\n<td>0.001 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibration well depth<\/td>\n<td>203 mm<\/td>\n<\/tr>\n<tr>\n<td>Optional reference input<\/td>\n<td>Available<\/td>\n<\/tr>\n<tr>\n<td>Reference thermometer characterization<\/td>\n<td>ITS 90 and CVD<\/td>\n<\/tr>\n<tr>\n<td>Programmable calibration procedures<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Setpoints per procedure<\/td>\n<td>Up to 8<\/td>\n<\/tr>\n<tr>\n<td>Temperature switch testing<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Communication interface<\/td>\n<td>RS232<\/td>\n<\/tr>\n<tr>\n<td>Calibration documentation<\/td>\n<td>NIST traceable calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 9173 or Fluke Calibration 9172?<\/h2>\n<p>The Fluke Calibration 9173 and Fluke Calibration 9172 belong to the same Metrology Well family but cover different temperature ranges.<\/p>\n<p>The <strong>Fluke Calibration 9173<\/strong> operates from:<\/p>\n<p><strong>+50 \u00b0C to +700 \u00b0C<\/strong><\/p>\n<p>The <strong>Fluke Calibration 9172<\/strong> operates from:<\/p>\n<p><strong>+35 \u00b0C to +425 \u00b0C<\/strong><\/p>\n<p>Both models feature a deep 203 mm calibration well and are designed for precision<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-9170-Metrology-Well-Calibrators.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 9173<\/strong> is a high precision metrology well designed for demanding temperature calibration from <strong>+50 \u00b0C to +700 \u00b0C<\/strong>.<\/p>\n<p>Temperature stability ranges from <strong>\u00b10.005 \u00b0C to \u00b10.03 \u00b0C<\/strong>, while the calibrated display provides accuracy from <strong>\u00b10.1 \u00b0C to \u00b10.25 \u00b0C<\/strong>, depending on temperature.<\/p>\n<p>A deep <strong>203 mm calibration well<\/strong>, interchangeable inserts and excellent axial and radial temperature uniformity make the Fluke Calibration 9173 ideal for precision comparison calibration.<\/p>\n<p>An optional integrated reference thermometer input, programmable calibration procedures, automatic temperature switch testing and RS232 communication support professional laboratory and industrial calibration applications.<\/p>\n","protected":false},"featured_media":3468,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[1206,53],"product_tag":[6035,6146,6147,6148,5010,4095,3922,6129,6130,3994,4110,6043,3999,4000,4001,4085,4003,4005],"class_list":["post-6854","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-blockkalibrator","product_tag-blockkalibrator-700-c","product_tag-fluke-9173","product_tag-fluke-calibration-9173","product_tag-hochtemperatur-kalibrator","product_tag-its-90","product_tag-kalibrierlabor","product_tag-metrologie-blockkalibrator","product_tag-metrology-well","product_tag-prt-kalibrieren","product_tag-referenzthermometer","product_tag-rtd-kalibrieren","product_tag-temperaturkalibrator","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-temperatursensor-kalibrieren","product_tag-thermoelement-kalibrieren","product_tag-trockenblockkalibrator","pa_bauart-tisch","pa_funktion-nur-heizen","pa_genauigkeit-02-c","pa_kanaele-integrierte-zweikanalanzeige-fuer-prt-rtd-thermoelemente-4-20-ma-strom","pa_messbereich-450c","pa_schnittstelle-rs232","pa_stabilitaet-001-c","pa_strom-versorgung-230-v","pa_temperaturbereich-30c-bis-425c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6854","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3468"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6854"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6854"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6854"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6854"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}