{"id":6888,"date":"2026-07-17T16:55:04","date_gmt":"2026-07-17T16:55:04","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-1586a\/"},"modified":"2026-10-13T08:25:26","modified_gmt":"2026-10-13T08:25:26","slug":"fluke-calibration-1586a","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-1586a\/","title":{"rendered":"Fluke Calibration 1586A Precise Temperature Scanner"},"content":{"rendered":"<p>The <strong>Fluke Calibration 1586A Super-DAQ<\/strong> is a high-precision temperature scanner and data acquisition system designed for demanding temperature measurements, automated sensor calibration and multi-channel data logging.<\/p>\n<p>With up to <strong>40 isolated universal input channels<\/strong>, temperature measurement accuracy down to <strong>\u00b10.005 \u00b0C for platinum resistance thermometers (PRTs)<\/strong> and scanning speeds of up to <strong>10 channels per second<\/strong>, the Fluke Calibration 1586A combines the performance of a precision thermometer with the flexibility of a professional data acquisition system.<\/p>\n<p>The instrument supports multiple sensor types, including thermocouples, platinum resistance thermometers, resistance temperature detectors (RTDs) and thermistors. It also measures DC voltage, DC current and resistance, making it suitable for a wide range of laboratory and industrial applications.<\/p>\n<p>The Fluke Calibration 1586A Super-DAQ is particularly suitable for temperature calibration laboratories, pharmaceutical manufacturing, aerospace applications, industrial quality assurance and research facilities requiring accurate, traceable and repeatable temperature measurements.<\/p>\n<p>Its large color display, integrated data logging, mathematical functions and flexible communication interfaces make the instrument a powerful solution for automated measurement applications.<\/p>\n<p>europascal provides professional temperature calibration equipment and technical support for demanding metrological applications.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Up to 40 isolated universal input channels<\/li>\n<li>Up to 45 analog measurement channels in total<\/li>\n<li>High-precision temperature measurements<\/li>\n<li>PRT accuracy down to \u00b10.005 \u00b0C<\/li>\n<li>Thermistor accuracy down to \u00b10.002 \u00b0C<\/li>\n<li>Thermocouple accuracy down to \u00b10.5 \u00b0C<\/li>\n<li>Scan speeds up to 10 channels per second<\/li>\n<li>Supports PRTs, RTDs, thermistors and thermocouples<\/li>\n<li>DC voltage, DC current and resistance measurements<\/li>\n<li>Four operating modes: Scan, Monitor, Measure and DMM<\/li>\n<li>Large color display with real-time trend visualization<\/li>\n<li>Up to four channels displayed simultaneously as trends<\/li>\n<li>Internal storage for 75,000 time-stamped readings<\/li>\n<li>20 MB non-volatile memory for data and configuration files<\/li>\n<li>USB storage support<\/li>\n<li>LAN and USB communication<\/li>\n<li>Automated temperature calibration capabilities<\/li>\n<li>Flexible channel configuration<\/li>\n<li>Mathematical channels and alarm functions<\/li>\n<li>User profiles for measurement data protection<\/li>\n<li>Suitable for laboratory and industrial applications<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>High-Precision Temperature Measurement<\/h2>\n<p>The Fluke Calibration 1586A is designed for applications requiring precise temperature measurements across multiple channels.<\/p>\n<p>Conventional temperature scanners often prioritize the number of channels over measurement accuracy.<\/p>\n<p>The Fluke Calibration 1586A combines high channel capacity with precision measurement performance.<\/p>\n<p>Depending on the sensor type, input configuration and operating conditions, the instrument achieves temperature measurement accuracy down to:<\/p>\n<p><strong>\u00b10.005 \u00b0C for PRTs<\/strong><\/p>\n<p><strong>\u00b10.002 \u00b0C for thermistors<\/strong><\/p>\n<p><strong>\u00b10.5 \u00b0C for thermocouples<\/strong><\/p>\n<p>These values represent selected manufacturer specifications under defined measurement conditions.<\/p>\n<p>Actual measurement accuracy depends on the connected sensor, measurement range, channel configuration, sampling rate and reference junction compensation.<\/p>\n<p>For demanding calibration applications, the uncertainty of the complete measurement system must be considered.<\/p>\n<h2>Up to 40 Isolated Universal Input Channels<\/h2>\n<p>One of the major advantages of the Fluke Calibration 1586A is its flexible multi-channel architecture.<\/p>\n<p>The instrument supports up to:<\/p>\n<p><strong>40 isolated universal input channels<\/strong><\/p>\n<p>through suitable input modules.<\/p>\n<p>Including the front-panel measurement connections and additional current measurement capabilities, the instrument provides up to 45 analog measurement channels.<\/p>\n<p>This allows numerous temperature sensors to be monitored within a single measurement system.<\/p>\n<p>The flexible channel architecture is particularly useful for applications involving large numbers of sensors.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Multi-point temperature calibration<\/li>\n<li>Temperature uniformity measurements<\/li>\n<li>Environmental chamber qualification<\/li>\n<li>Temperature mapping<\/li>\n<li>Industrial process monitoring<\/li>\n<li>Research and development<\/li>\n<li>Temperature sensor comparison measurements<\/li>\n<\/ul>\n<p>The actual number and type of available channels depend on the installed input modules.<\/p>\n<h2>Flexible Input Modules<\/h2>\n<p>The Fluke Calibration 1586A supports different input module configurations.<\/p>\n<p>Two important module types are available.<\/p>\n<h3>High-Capacity Input Module<\/h3>\n<p>The High-Capacity Input Module is designed for applications requiring a large number of measurement channels.<\/p>\n<p>It provides convenient connections for multiple temperature sensors and electrical measurement signals.<\/p>\n<p>This module is particularly suitable for data acquisition applications where channel capacity and scanning speed are important.<\/p>\n<h3>DAQ-STAQ Input Module<\/h3>\n<p>The DAQ-STAQ Input Module is designed for demanding temperature measurement applications requiring convenient sensor connections and improved thermocouple reference junction performance.<\/p>\n<p>The module provides a practical connection system for laboratory applications and temperature sensor calibration.<\/p>\n<p>The appropriate module should be selected according to the required sensor types, channel capacity and measurement uncertainty.<\/p>\n<h2>Scan Speeds Up to 10 Channels per Second<\/h2>\n<p>The Fluke Calibration 1586A provides three selectable scanning speeds.<\/p>\n<p><strong>Fast: 10 channels per second<\/strong><\/p>\n<p><strong>Medium: 1 channel per second<\/strong><\/p>\n<p><strong>Slow: 1 channel every 4 seconds<\/strong><\/p>\n<p>This allows users to select the appropriate balance between measurement speed and accuracy.<\/p>\n<p>Fast scanning is particularly useful when monitoring dynamic temperature changes across multiple channels.<\/p>\n<p>Medium and slow scanning modes are suitable for precision measurements where maximum measurement performance is required.<\/p>\n<p>The specified measurement accuracy may depend on the selected scanning speed.<\/p>\n<p>For demanding calibration applications, the appropriate measurement speed should therefore be selected according to the required uncertainty.<\/p>\n<h2>Four Operating Modes<\/h2>\n<p>The Fluke Calibration 1586A provides four operating modes.<\/p>\n<h3>Scan Mode<\/h3>\n<p>Scan Mode allows multiple configured channels to be measured automatically.<\/p>\n<p>The instrument sequentially measures the selected channels and records the results.<\/p>\n<p>This mode is particularly suitable for temperature mapping, environmental monitoring and automated data acquisition.<\/p>\n<h3>Monitor Mode<\/h3>\n<p>Monitor Mode allows the user to observe a selected measurement channel.<\/p>\n<p>This is useful when checking the behavior of an individual sensor during a measurement process.<\/p>\n<h3>Measure Mode<\/h3>\n<p>Measure Mode provides direct measurement capabilities for selected input signals.<\/p>\n<p>It is suitable for individual precision measurements and sensor verification.<\/p>\n<h3>Digital Multimeter Mode<\/h3>\n<p>The integrated DMM functionality allows the instrument to measure electrical quantities such as voltage, current and resistance.<\/p>\n<p>This provides additional flexibility beyond conventional temperature scanning systems.<\/p>\n<h2>Platinum Resistance Thermometer Measurements<\/h2>\n<p>The Fluke Calibration 1586A supports platinum resistance thermometers and industrial RTDs.<\/p>\n<p>The supported temperature measurement range extends from:<\/p>\n<p><strong>\u2212200 \u00b0C to +1200 \u00b0C<\/strong><\/p>\n<p>depending on the connected sensor.<\/p>\n<p>The instrument provides resistance measurement capabilities up to 4 k\u03a9.<\/p>\n<p>Precision four-wire resistance measurement helps reduce the influence of connecting lead resistance.<\/p>\n<p>For selected resistance ranges, automatic current reversal reduces the influence of thermoelectric voltages.<\/p>\n<p>The Fluke Calibration 1586A supports individual thermometer characterization, allowing accurate temperature conversion using appropriate calibration coefficients.<\/p>\n<p>This makes the instrument suitable for precision PRT measurements and automated temperature sensor calibration.<\/p>\n<h2>Thermistor Measurements<\/h2>\n<p>The Fluke Calibration 1586A also supports precision thermistor measurements.<\/p>\n<p>Thermistors are particularly useful for applications requiring high temperature sensitivity over a limited operating range.<\/p>\n<p>The manufacturer specifies temperature measurement accuracy down to:<\/p>\n<p><strong>\u00b10.002 \u00b0C<\/strong><\/p>\n<p>under defined conditions.<\/p>\n<p>The supported thermistor temperature range depends on the connected sensor.<\/p>\n<p>The instrument provides a temperature display resolution down to:<\/p>\n<p><strong>0.0001 \u00b0C<\/strong><\/p>\n<p>for suitable thermistor measurements.<\/p>\n<p>This makes the Fluke Calibration 1586A suitable for demanding temperature stability investigations and precision laboratory measurements.<\/p>\n<h2>Thermocouple Measurements<\/h2>\n<p>The Fluke Calibration 1586A supports multiple thermocouple types.<\/p>\n<p>Thermocouples are widely used in industrial processes because they cover large temperature ranges and are suitable for demanding environments.<\/p>\n<p>The instrument supports thermocouple measurements over a wide range, depending on the thermocouple type.<\/p>\n<p>The manufacturer specifies thermocouple measurement accuracy down to approximately:<\/p>\n<p><strong>\u00b10.5 \u00b0C<\/strong><\/p>\n<p>under defined conditions.<\/p>\n<p>For accurate thermocouple measurements, reference junction compensation is essential.<\/p>\n<p>The Fluke Calibration 1586A supports internal and external cold junction compensation.<\/p>\n<p>The accuracy of the internal reference junction compensation depends on the installed input module.<\/p>\n<h2>Cold Junction Compensation<\/h2>\n<p>Thermocouples generate a thermoelectric voltage depending on the temperature difference between the measuring junction and reference junction.<\/p>\n<p>The Fluke Calibration 1586A provides cold junction compensation to determine the corresponding measurement temperature.<\/p>\n<p>The DAQ-STAQ Input Module provides a basic cold junction compensation accuracy of:<\/p>\n<p><strong>0.25 \u00b0C<\/strong><\/p>\n<p>The High-Capacity Input Module provides a basic cold junction compensation accuracy of:<\/p>\n<p><strong>0.6 \u00b0C<\/strong><\/p>\n<p>These values describe the reference junction compensation performance and are not the complete thermocouple measurement accuracy.<\/p>\n<p>For demanding thermocouple calibration, external reference junction compensation may provide improved measurement performance.<\/p>\n<h2>DC Voltage Measurements<\/h2>\n<p>In addition to temperature measurements, the Fluke Calibration 1586A supports DC voltage measurement.<\/p>\n<p>Available voltage ranges include:<\/p>\n<ul>\n<li>\u00b1100 mV<\/li>\n<li>\u00b11 V<\/li>\n<li>\u00b110 V<\/li>\n<li>\u00b150 V<\/li>\n<\/ul>\n<p>The maximum permitted input voltage is 50 V.<\/p>\n<p>This functionality allows the instrument to measure electrical signals from temperature transmitters and other compatible measurement devices.<\/p>\n<p>The voltage measurement function is particularly useful for applications involving thermocouples and industrial instrumentation.<\/p>\n<h2>DC Current Measurements<\/h2>\n<p>The Fluke Calibration 1586A also supports DC current measurements.<\/p>\n<p>This allows the instrument to monitor current signals used in industrial measurement systems.<\/p>\n<p>Typical applications include checking compatible process transmitters and monitoring electrical signals.<\/p>\n<p>The appropriate measurement configuration and input protection requirements must always be observed.<\/p>\n<h2>Resistance Measurements<\/h2>\n<p>The Fluke Calibration 1586A provides precision resistance measurement capabilities.<\/p>\n<p>Resistance measurements are particularly important for platinum resistance thermometers and thermistors.<\/p>\n<p>The instrument supports two-wire, three-wire and four-wire resistance measurement configurations, depending on the sensor and input module.<\/p>\n<p>Four-wire measurement provides the best protection against errors caused by connecting lead resistance.<\/p>\n<p>For precision temperature calibration, the selected measurement configuration should be included in the uncertainty evaluation.<\/p>\n<h2>Large Color Display and Real-Time Trending<\/h2>\n<p>The Fluke Calibration 1586A features a large color display.<\/p>\n<p>The instrument provides real-time graphical trending for up to four channels.<\/p>\n<p>This allows users to observe temperature changes and compare the behavior of different sensors.<\/p>\n<p>Graphical trending is particularly useful for:<\/p>\n<ul>\n<li>Temperature stability measurements<\/li>\n<li>Environmental chamber monitoring<\/li>\n<li>Sensor comparison<\/li>\n<li>Process monitoring<\/li>\n<li>Temperature uniformity investigations<\/li>\n<\/ul>\n<p>The display provides direct access to measurement values and instrument configuration functions.<\/p>\n<h2>Integrated Data Logging<\/h2>\n<p>The Fluke Calibration 1586A includes integrated data logging capabilities.<\/p>\n<p>The instrument can store up to:<\/p>\n<p><strong>75,000 time-stamped measurement readings<\/strong><\/p>\n<p>in internal measurement memory.<\/p>\n<p>It also provides:<\/p>\n<p><strong>20 MB of non-volatile memory<\/strong><\/p>\n<p>for measurement data and configuration files.<\/p>\n<p>Recorded measurements can be transferred to external storage for further evaluation.<\/p>\n<p>This makes the instrument suitable for long-term temperature monitoring and automated measurement documentation.<\/p>\n<h2>USB Data Storage<\/h2>\n<p>The Fluke Calibration 1586A supports external USB storage devices.<\/p>\n<p>The USB host interface allows measurement data and configuration files to be stored externally.<\/p>\n<p>The manufacturer specifies support for USB storage devices with capacities up to:<\/p>\n<p><strong>32 GB<\/strong><\/p>\n<p>using the FAT32 file system.<\/p>\n<p>This provides convenient transfer of measurement data to computers for analysis and documentation.<\/p>\n<h2>Mathematical Channels<\/h2>\n<p>The Fluke Calibration 1586A provides up to:<\/p>\n<p><strong>20 mathematical channels<\/strong><\/p>\n<p>These allow calculations to be performed using measured values.<\/p>\n<p>Supported mathematical operations include:<\/p>\n<ul>\n<li>Addition<\/li>\n<li>Subtraction<\/li>\n<li>Multiplication<\/li>\n<li>Division<\/li>\n<li>Average<\/li>\n<li>Maximum<\/li>\n<li>Minimum<\/li>\n<li>Absolute value<\/li>\n<li>Square root<\/li>\n<li>Exponential functions<\/li>\n<li>Logarithmic functions<\/li>\n<li>Polynomial calculations<\/li>\n<\/ul>\n<p>Mathematical channels are particularly useful for evaluating temperature differences between sensors.<\/p>\n<p>For example, the difference between a reference thermometer and a device under test can be calculated directly.<\/p>\n<h2>Alarm Functions<\/h2>\n<p>The Fluke Calibration 1586A includes configurable alarm functions.<\/p>\n<p>The instrument provides six alarm outputs.<\/p>\n<p>These can be used to monitor measurement conditions and identify values outside defined limits.<\/p>\n<p>Alarm functions are useful for temperature monitoring, process control and automated measurement systems.<\/p>\n<h2>Automated Temperature Calibration<\/h2>\n<p>The Fluke Calibration 1586A is particularly suitable for automated temperature sensor calibration.<\/p>\n<p>When combined with a compatible Fluke Calibration temperature source, the instrument can be integrated into automated calibration systems.<\/p>\n<p>Multiple sensors can be connected and measured sequentially.<\/p>\n<p>This reduces manual intervention and improves the efficiency of repeated calibration procedures.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Batch calibration of RTDs<\/li>\n<li>Multi-channel thermocouple calibration<\/li>\n<li>PRT comparison calibration<\/li>\n<li>Temperature sensor characterization<\/li>\n<li>Automated calibration documentation<\/li>\n<\/ul>\n<p>The complete calibration uncertainty depends on the reference thermometer, temperature source, scanner performance and measurement procedure.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 1586A<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>1586A<\/td>\n<\/tr>\n<tr>\n<td>Product family<\/td>\n<td>Super-DAQ<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Precision Temperature Scanner<\/td>\n<\/tr>\n<tr>\n<td>Universal input channels<\/td>\n<td>Up to 40<\/td>\n<\/tr>\n<tr>\n<td>Total analog measurement channels<\/td>\n<td>Up to 45<\/td>\n<\/tr>\n<tr>\n<td>PRT measurement accuracy<\/td>\n<td>Down to \u00b10.005 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermistor measurement accuracy<\/td>\n<td>Down to \u00b10.002 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple measurement accuracy<\/td>\n<td>Down to \u00b10.5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>PRT\/RTD temperature range<\/td>\n<td>\u2212200 \u00b0C to +1200 \u00b0C, sensor-dependent<\/td>\n<\/tr>\n<tr>\n<td>Resistance measurement range for PRT\/RTD<\/td>\n<td>0 \u03a9 to 4 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Thermistor temperature resolution<\/td>\n<td>Down to 0.0001 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>PRT temperature resolution<\/td>\n<td>Down to 0.001 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Fast scanning<\/td>\n<td>10 channels\/s<\/td>\n<\/tr>\n<tr>\n<td>Medium scanning<\/td>\n<td>1 channel\/s<\/td>\n<\/tr>\n<tr>\n<td>Slow scanning<\/td>\n<td>1 channel\/4 s<\/td>\n<\/tr>\n<tr>\n<td>Operating modes<\/td>\n<td>Scan, Monitor, Measure, DMM<\/td>\n<\/tr>\n<tr>\n<td>Voltage ranges<\/td>\n<td>\u00b1100 mV, \u00b11 V, \u00b110 V, \u00b150 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum input voltage<\/td>\n<td>50 V<\/td>\n<\/tr>\n<tr>\n<td>Mathematical channels<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>Alarm outputs<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>Internal measurement memory<\/td>\n<td>75,000 readings<\/td>\n<\/tr>\n<tr>\n<td>Non-volatile memory<\/td>\n<td>20 MB<\/td>\n<\/tr>\n<tr>\n<td>USB storage<\/td>\n<td>Up to 32 GB<\/td>\n<\/tr>\n<tr>\n<td>USB communication<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>LAN communication<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>Color display<\/td>\n<\/tr>\n<tr>\n<td>Real-time trending<\/td>\n<td>Up to 4 channels<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>0 \u00b0C to 50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Full accuracy ambient temperature<\/td>\n<td>18 \u00b0C to 28 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Warm-up time<\/td>\n<td>1 hour<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>36 VA peak, 24 W average<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>Manufacturer calibration available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and calibration equipment.<\/p>\n<p>When the Fluke Calibration 1586A is used as a precision temperature scanner, its measurement accuracy and calibration uncertainty must be considered together with the characteristics of the connected sensors.<\/p>\n<p>For temperature calibration applications, relevant uncertainty contributions may include:<\/p>\n<ul>\n<li>Reference thermometer calibration uncertainty<\/li>\n<li>Resistance measurement uncertainty<\/li>\n<li>Thermocouple voltage measurement uncertainty<\/li>\n<li>Cold junction compensation<\/li>\n<li>Temperature source stability<\/li>\n<li>Temperature uniformity<\/li>\n<li>Sensor immersion effects<\/li>\n<li>Measurement repeatability<\/li>\n<\/ul>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Fluke Calibration 1586A?<\/h2>\n<p>The Fluke Calibration 1586A combines high-precision temperature measurement with flexible multi-channel data acquisition.<\/p>\n<p>Its ability to measure up to 40 universal input channels makes it suitable for complex measurement applications involving multiple sensors.<\/p>\n<p>Precision measurement performance down to \u00b10.005 \u00b0C for PRTs and \u00b10.002 \u00b0C for thermistors supports demanding laboratory applications.<\/p>\n<p>Scan speeds up to 10 channels per second provide flexibility for applications requiring rapid data acquisition.<\/p>\n<p>The instrument supports PRTs, RTDs, thermistors, thermocouples and electrical measurement signals.<\/p>\n<p>Integrated data logging, mathematical functions, graphical trending and alarm capabilities simplify measurement evaluation.<\/p>\n<p>The combination of precision measurement and automated scanning makes the Fluke Calibration 1586A particularly suitable for temperature calibration laboratories, industrial quality assurance and research facilities.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the Fluke Calibration 1586A<\/h2>\n<p>The Fluke Calibration 1586A is suitable for numerous professional measurement applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Automated temperature sensor calibration<\/li>\n<li>Multi-channel temperature measurements<\/li>\n<li>PRT and RTD calibration<\/li>\n<li>Thermocouple calibration<\/li>\n<li>Thermistor measurements<\/li>\n<li>Temperature mapping<\/li>\n<li>Environmental chamber qualification<\/li>\n<li>Temperature stability investigations<\/li>\n<li>Industrial process monitoring<\/li>\n<li>Pharmaceutical manufacturing<\/li>\n<li>Aerospace applications<\/li>\n<li>Research and development<\/li>\n<li>Quality assurance<\/li>\n<li>Calibration laboratories<\/li>\n<li>Automated data acquisition<\/li>\n<\/ul>\n<p>The combination of high measurement accuracy, flexible channel configuration and integrated data logging makes the Fluke Calibration 1586A Super-DAQ a professional solution for precision temperature scanning and automated measurement applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Find more Fluke Calibration products here.<\/a><\/p>\n<p>Manufacturer information for the Fluke Calibration 1586A can be found on the <a href=\"https:\/\/www.fluke.com\/en-ca\/product\/calibration-tools\/temperature-calibrators\/fluke-calibration-1586a\" target=\"_blank\" rel=\"noopener\">official Fluke Calibration website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-1586A-Super-DAQPrecision-Temperature-Scanner.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 1586A Super-DAQ<\/strong> is a high-precision temperature scanner and data acquisition system for professional calibration laboratories and industrial applications.\u00a0With up to <strong>40 isolated universal input channels<\/strong>, measurement accuracy down to <strong>\u00b10.005 \u00b0C for PRTs<\/strong> and <strong>\u00b10.002 \u00b0C for thermistors<\/strong>, and scan speeds of up to <strong>10 channels per second<\/strong>, the instrument provides excellent performance for demanding multi-channel measurements.\u00a0The Fluke Calibration 1586A supports thermocouples, RTDs, PRTs, thermistors, DC voltage, DC current and resistance measurements. Integrated data logging, real-time graphical trending, mathematical functions and flexible communication interfaces make it ideal for automated temperature calibration and precision data acquisition.<\/p>\n","protected":false},"featured_media":3491,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[57,53],"product_tag":[6181,6182,4104,6183,6184,3922,6185,6186,6187,6188,6189,6190,4000,5942,4001,6191,5943,6192,6193],"class_list":["post-6888","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-temperature-indicators","product_cat-temperature","product_tag-1586a-super-daq","product_tag-daq-staq","product_tag-datenlogger-temperatur","product_tag-fluke-1586a","product_tag-fluke-calibration-1586a","product_tag-kalibrierlabor","product_tag-mehrfachkalibrierung-temperaturfuehler","product_tag-mehrkanal-temperaturmessgeraet","product_tag-prt-scanner","product_tag-pt100-datenerfasser","product_tag-super-daq","product_tag-temperatur-datenerfasser","product_tag-temperaturkalibrierung","product_tag-temperaturmapping","product_tag-temperaturmesstechnik","product_tag-temperaturscanner","product_tag-temperaturvalidierung","product_tag-thermistor-scanner","product_tag-thermoelement-scanner","pa_kanaele-vierkanal-thermometer-mit-digitalanzeige","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6888","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3491"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6888"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6888"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6888"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6888"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}