{"id":6907,"date":"2026-07-17T16:51:06","date_gmt":"2026-07-17T16:51:06","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-9102s\/"},"modified":"2026-10-13T09:29:46","modified_gmt":"2026-10-13T09:29:46","slug":"fluke-calibration-9102s","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-9102s\/","title":{"rendered":"Fluke Calibration 9100S Compact Dry Block Calibrator"},"content":{"rendered":"<p>The <strong>Fluke Calibration 9100S<\/strong> is a compact handheld dry block calibrator designed for accurate temperature sensor calibration in industrial environments, calibration laboratories and field service applications.<\/p>\n<p>With a temperature range from <strong>+35 \u00b0C to +375 \u00b0C<\/strong>, excellent temperature control and a weight of only <strong>1 kg<\/strong>, the Fluke Calibration 9100S combines reliable calibration performance with exceptional portability.<\/p>\n<p>The instrument is particularly suitable for calibrating resistance temperature detectors (RTDs), thermocouples and small bimetal thermometers directly at the installation site.<\/p>\n<p>Unlike conventional temperature calibration baths, the Fluke Calibration 9100S uses a dry metal block to generate controlled temperatures. This eliminates the need for calibration liquids and simplifies transportation, preparation and maintenance.<\/p>\n<p>Its compact construction makes the Fluke Calibration 9100S ideal for technicians who need a portable temperature source for routine calibration, commissioning and preventive maintenance.<\/p>\n<p>The instrument features simple front-panel controls, a digital temperature display and an RS-232 interface for communication with compatible external equipment.<\/p>\n<p>With a heating time of approximately 9.5 minutes from 35 \u00b0C to 375 \u00b0C, the Fluke Calibration 9100S significantly reduces waiting times between calibration points.<\/p>\n<p>For professional temperature calibration equipment and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Temperature range from +35 \u00b0C to +375 \u00b0C<\/li>\n<li>Extremely compact handheld construction<\/li>\n<li>Lightweight design weighing only 1 kg<\/li>\n<li>Temperature accuracy of \u00b10.25 \u00b0C at 50 \u00b0C and 100 \u00b0C<\/li>\n<li>Temperature accuracy of \u00b10.5 \u00b0C at 375 \u00b0C<\/li>\n<li>Temperature stability of \u00b10.07 \u00b0C at 50 \u00b0C<\/li>\n<li>Temperature stability of \u00b10.1 \u00b0C at 100 \u00b0C<\/li>\n<li>Temperature stability of \u00b10.3 \u00b0C at 375 \u00b0C<\/li>\n<li>Digital temperature display with 0.1 \u00b0C resolution<\/li>\n<li>Fast heating from 35 \u00b0C to 375 \u00b0C in approximately 9.5 minutes<\/li>\n<li>Cooling from 375 \u00b0C to 100 \u00b0C in approximately 14 minutes<\/li>\n<li>Typical stabilization time of 5 minutes<\/li>\n<li>Multiple calibration wells<\/li>\n<li>Different well configurations available<\/li>\n<li>Suitable for RTDs and Pt100 sensors<\/li>\n<li>Suitable for thermocouples<\/li>\n<li>Suitable for small bimetal thermometers<\/li>\n<li>Integrated RS-232 interface<\/li>\n<li>Simple front-panel operation<\/li>\n<li>No calibration liquid required<\/li>\n<li>Traceable manufacturer calibration data<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Temperature Range from +35 \u00b0C to +375 \u00b0C<\/h2>\n<p>The <strong>Fluke Calibration 9100S<\/strong> provides a temperature calibration range of:<\/p>\n<p><strong>+35 \u00b0C to +375 \u00b0C<\/strong><\/p>\n<p>This temperature range covers numerous industrial and laboratory calibration applications.<\/p>\n<p>The instrument is particularly suitable for temperature sensors used in manufacturing, process instrumentation, heating systems and industrial maintenance.<\/p>\n<p>Typical calibration temperatures include:<\/p>\n<ul>\n<li>50 \u00b0C<\/li>\n<li>100 \u00b0C<\/li>\n<li>150 \u00b0C<\/li>\n<li>200 \u00b0C<\/li>\n<li>250 \u00b0C<\/li>\n<li>300 \u00b0C<\/li>\n<li>375 \u00b0C<\/li>\n<\/ul>\n<p>The temperature can be adjusted directly using the front-panel controls.<\/p>\n<p>The integrated temperature controller regulates the heating block to the selected setpoint.<\/p>\n<p>For demanding calibration applications, sufficient stabilization time must be allowed before recording measurement results.<\/p>\n<h2>High Temperature Accuracy<\/h2>\n<p>The Fluke Calibration 9100S provides reliable temperature accuracy across its operating range.<\/p>\n<p>The manufacturer specifies the following accuracy values:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature<\/th>\n<th>Accuracy<\/th>\n<\/tr>\n<tr>\n<td>50 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>100 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>375 \u00b0C<\/td>\n<td>\u00b10.5 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These values describe the manufacturer&#8217;s specified temperature accuracy under defined operating conditions.<\/p>\n<p>They should not be confused with the temperature stability specification or the calibration uncertainty stated on an individual calibration certificate.<\/p>\n<p>For demanding comparison calibrations, an external reference thermometer can be used to measure the actual temperature of the calibration block.<\/p>\n<p>The uncertainty of the complete measurement system must be considered when evaluating calibration results.<\/p>\n<h2>Excellent Temperature Stability<\/h2>\n<p>The Fluke Calibration 9100S provides stable temperature conditions for sensor calibration.<\/p>\n<p>The manufacturer specifies:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature<\/th>\n<th>Temperature Stability<\/th>\n<\/tr>\n<tr>\n<td>50 \u00b0C<\/td>\n<td>\u00b10.07 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>100 \u00b0C<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>375 \u00b0C<\/td>\n<td>\u00b10.3 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Temperature stability describes the variation of the calibration block temperature over time under specified conditions.<\/p>\n<p>Stable temperature conditions are essential for obtaining reliable calibration results.<\/p>\n<p>When several temperature sensors are calibrated simultaneously, sufficient stabilization is particularly important.<\/p>\n<p>The actual measurement uncertainty depends on the temperature stability, temperature uniformity, reference thermometer and device under test.<\/p>\n<h2>Fast Heating Performance<\/h2>\n<p>One of the main advantages of the Fluke Calibration 9100S is its fast heating performance.<\/p>\n<p>The manufacturer specifies a typical heating time of:<\/p>\n<p><strong>9.5 minutes from 35 \u00b0C to 375 \u00b0C<\/strong><\/p>\n<p>This allows technicians to reach high calibration temperatures quickly.<\/p>\n<p>Short heating times are particularly useful when performing multi-point calibration procedures.<\/p>\n<p>The fast temperature response helps reduce waiting times and improves calibration efficiency.<\/p>\n<p>Actual heating times may depend on ambient conditions, sensor loading and operating conditions.<\/p>\n<h2>Efficient Cooling Performance<\/h2>\n<p>The Fluke Calibration 9100S also provides efficient cooling performance.<\/p>\n<p>The manufacturer specifies a typical cooling time of:<\/p>\n<p><strong>14 minutes from 375 \u00b0C to 100 \u00b0C<\/strong><\/p>\n<p>This allows technicians to perform calibration procedures involving both increasing and decreasing temperature sequences.<\/p>\n<p>Cooling times depend on the initial temperature, ambient conditions and thermal loading.<\/p>\n<p>The instrument should always be allowed to cool sufficiently before transportation or storage.<\/p>\n<h2>Short Stabilization Time<\/h2>\n<p>The Fluke Calibration 9100S features a typical stabilization time of:<\/p>\n<p><strong>5 minutes<\/strong><\/p>\n<p>This describes the time required for the calibration block to stabilize under the manufacturer&#8217;s specified conditions.<\/p>\n<p>The stabilization time of the device under test must also be considered.<\/p>\n<p>Large sensors or sensors with slow thermal response may require additional time before reliable measurements can be recorded.<\/p>\n<p>For demanding calibration procedures, temperature stabilization should be verified using a suitable reference thermometer.<\/p>\n<h2>Compact Handheld Construction<\/h2>\n<p>The Fluke Calibration 9100S is one of the most compact dry block calibrators available for industrial temperature calibration.<\/p>\n<p>Its dimensions are:<\/p>\n<p><strong>57 \u00d7 125 \u00d7 150 mm<\/strong><\/p>\n<p>The instrument weighs approximately:<\/p>\n<p><strong>1 kg<\/strong><\/p>\n<p>This makes it particularly suitable for mobile calibration applications.<\/p>\n<p>The compact design allows technicians to transport the instrument easily between different measurement locations.<\/p>\n<p>It also requires very little space on a workbench.<\/p>\n<p>The Fluke Calibration 9100S is therefore an excellent solution for service technicians who need to calibrate temperature sensors directly at the installation site.<\/p>\n<h2>Multiple Calibration Wells<\/h2>\n<p>The Fluke Calibration 9100S features an integrated metal calibration block with several sensor wells.<\/p>\n<p>Different configurations are available to accommodate temperature sensors with different diameters.<\/p>\n<p>The standard well depth is:<\/p>\n<p><strong>102 mm<\/strong><\/p>\n<p>The smallest 1.6 mm well has a depth of:<\/p>\n<p><strong>89 mm<\/strong><\/p>\n<p>The appropriate well configuration should be selected according to the diameter of the temperature sensors being calibrated.<\/p>\n<p>Good thermal contact between the sensor and the calibration well is essential for minimizing measurement errors.<\/p>\n<p>The sensor should be inserted sufficiently deeply to reduce heat conduction effects along the probe stem.<\/p>\n<h2>Different Model Configurations<\/h2>\n<p>The Fluke Calibration 9100S is available in several configurations.<\/p>\n<h3>Fluke Calibration 9100S-A<\/h3>\n<p>The 9100S-A is a handheld dry block calibrator with well configuration A.<\/p>\n<h3>Fluke Calibration 9100S-B<\/h3>\n<p>The 9100S-B provides an alternative calibration well configuration.<\/p>\n<h3>Fluke Calibration 9100S-C<\/h3>\n<p>The 9100S-C is designed for applications requiring another combination of sensor well diameters.<\/p>\n<h3>Fluke Calibration 9100S-D<\/h3>\n<p>The 9100S-D provides an additional calibration well configuration.<\/p>\n<p>The appropriate version should be selected according to the dimensions of the temperature sensors being calibrated.<\/p>\n<p>Unlike dry block calibrators with removable inserts, the Fluke Calibration 9100S uses fixed calibration wells.<\/p>\n<p>The well configuration is therefore an important consideration when ordering.<\/p>\n<h2>Calibration of RTDs and Pt100 Sensors<\/h2>\n<p>The Fluke Calibration 9100S is suitable for calibrating resistance temperature detectors.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Pt100 calibration<\/li>\n<li>Pt1000 calibration<\/li>\n<li>Industrial RTD calibration<\/li>\n<li>Temperature probe verification<\/li>\n<li>Temperature indicator testing<\/li>\n<\/ul>\n<p>The RTD sensor is inserted into a suitable calibration well.<\/p>\n<p>The dry block generates a controlled temperature that can be compared with the temperature indicated by the device under test.<\/p>\n<p>For more demanding applications, an external reference thermometer can be used.<\/p>\n<p>The Fluke Calibration 9100S provides the temperature source but does not directly measure the electrical resistance of the RTD.<\/p>\n<p>A suitable thermometer readout or resistance measurement instrument is required.<\/p>\n<h2>Calibration of Thermocouples<\/h2>\n<p>The Fluke Calibration 9100S can also be used for thermocouple calibration.<\/p>\n<p>Thermocouples are widely used in industrial applications requiring elevated temperatures.<\/p>\n<p>The instrument provides a stable temperature environment for checking thermocouple measurement systems.<\/p>\n<p>The thermocouple is inserted into the calibration block and allowed to stabilize.<\/p>\n<p>Its indicated temperature can then be compared with the reference temperature.<\/p>\n<p>For accurate thermocouple calibration, reference junction compensation and the measurement uncertainty of the readout must be considered.<\/p>\n<h2>Calibration of Bimetal Thermometers<\/h2>\n<p>The Fluke Calibration 9100S is suitable for checking small bimetal thermometers.<\/p>\n<p>Bimetal thermometers are commonly used in industrial heating systems, machinery and process equipment.<\/p>\n<p>The sensing element is inserted into a suitable calibration well.<\/p>\n<p>The indicated temperature can then be compared with the temperature generated by the calibration block.<\/p>\n<p>The compact design of the Fluke Calibration 9100S makes it particularly useful for routine verification of mechanical temperature indicators.<\/p>\n<h2>RS-232 Interface<\/h2>\n<p>The Fluke Calibration 9100S includes an RS-232 communication interface.<\/p>\n<p>This interface allows the instrument to communicate with compatible external equipment.<\/p>\n<p>RS-232 communication can be used for remote operation and integration into suitable calibration systems.<\/p>\n<p>This is particularly useful for laboratories and industrial users who want to incorporate the dry block calibrator into automated or computer-assisted calibration procedures.<\/p>\n<p>The available communication commands and interface settings are described in the manufacturer&#8217;s operating instructions.<\/p>\n<h2>Simple Front-Panel Operation<\/h2>\n<p>The Fluke Calibration 9100S is designed for straightforward operation.<\/p>\n<p>The temperature setpoint can be entered using the front-panel buttons.<\/p>\n<p>The digital display provides information about the temperature.<\/p>\n<p>The instrument features a display resolution of:<\/p>\n<p><strong>0.1 \u00b0C<\/strong><\/p>\n<p>This makes it easy to set and monitor calibration temperatures.<\/p>\n<p>The simple operating concept reduces training requirements and allows technicians to begin calibration work quickly.<\/p>\n<h2>No Calibration Liquid Required<\/h2>\n<p>Unlike liquid calibration baths, the Fluke Calibration 9100S does not require a calibration fluid.<\/p>\n<p>The instrument uses a solid metal block to transfer heat to the temperature sensors.<\/p>\n<p>This provides several practical advantages.<\/p>\n<p>There is no need to fill or drain calibration liquid.<\/p>\n<p>The risk of fluid leakage during transportation is eliminated.<\/p>\n<p>Cleaning and maintenance requirements are reduced.<\/p>\n<p>The instrument can be prepared for use quickly.<\/p>\n<p>These advantages make the Fluke Calibration 9100S particularly suitable for field calibration and mobile maintenance applications.<\/p>\n<h2>Traceable Manufacturer Calibration<\/h2>\n<p>The Fluke Calibration 9100S is supplied with manufacturer calibration data traceable to national standards.<\/p>\n<p>The manufacturer specifies calibration data at the following temperatures:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Calibration Point<\/th>\n<\/tr>\n<tr>\n<td>50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>100 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>150 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>200 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>250 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>300 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>375 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These calibration points cover the main operating range of the instrument.<\/p>\n<p>Regular recalibration is recommended to verify the long-term performance of the dry block calibrator.<\/p>\n<p>For applications requiring accredited calibration, the availability and scope of the appropriate calibration service should be confirmed separately.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 9100S<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>9100S<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Handheld Dry Block Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>+35 \u00b0C to +375 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 50 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 100 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 375 \u00b0C<\/td>\n<td>\u00b10.5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability at 50 \u00b0C<\/td>\n<td>\u00b10.07 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability at 100 \u00b0C<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Stability at 375 \u00b0C<\/td>\n<td>\u00b10.3 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Heating time, 35 \u00b0C to 375 \u00b0C<\/td>\n<td>9.5 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, 375 \u00b0C to 100 \u00b0C<\/td>\n<td>14 minutes<\/td>\n<\/tr>\n<tr>\n<td>Typical stabilization time<\/td>\n<td>5 minutes<\/td>\n<\/tr>\n<tr>\n<td>Well-to-well uniformity<\/td>\n<td>\u00b10.2 \u00b0C under specified conditions<\/td>\n<\/tr>\n<tr>\n<td>Standard well depth<\/td>\n<td>102 mm<\/td>\n<\/tr>\n<tr>\n<td>Smallest well depth<\/td>\n<td>89 mm<\/td>\n<\/tr>\n<tr>\n<td>Removable inserts<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>Model configurations<\/td>\n<td>9100S-A, B, C and D<\/td>\n<\/tr>\n<tr>\n<td>Communication interface<\/td>\n<td>RS-232<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>115 V or 230 V AC version<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>175 W<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (H \u00d7 W \u00d7 D)<\/td>\n<td>57 \u00d7 125 \u00d7 150 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 1 kg<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>NIST-traceable manufacturer calibration data<\/td>\n<\/tr>\n<tr>\n<td>Typical applications<\/td>\n<td>RTD, thermocouple and bimetal thermometer calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 9100S or 9102S?<\/h2>\n<p>The Fluke Calibration 9100S and 9102S are both compact handheld dry block calibrators.<\/p>\n<p>However, they are designed for different temperature ranges.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 9100S<\/th>\n<th>Fluke Calibration 9102S<\/th>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>+35 \u00b0C to +375 \u00b0C<\/td>\n<td>\u221210 \u00b0C to +122 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>\u00b10.25 \u00b0C to \u00b10.5 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.07 \u00b0C to \u00b10.3 \u00b0C<\/td>\n<td>\u00b10.05 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>0.1 \u00b0C<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Well depth<\/td>\n<td>102 mm<\/td>\n<td>102 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>1 kg<\/td>\n<td>1.8 kg<\/td>\n<\/tr>\n<tr>\n<td>RS-232 interface<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Removable inserts<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The <strong>Fluke Calibration 9100S<\/strong> is particularly suitable for applications requiring temperatures up to 375 \u00b0C.<\/p>\n<p>The <strong>Fluke Calibration 9102S<\/strong> is designed for applications requiring temperatures below ambient temperature.<\/p>\n<p>The correct model should be selected according to the required temperature range, sensor dimensions and calibration uncertainty.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and calibration equipment.<\/p>\n<p>When the Fluke Calibration 9100S is used for temperature sensor calibration, the measurement uncertainty must be evaluated according to the complete measurement procedure.<\/p>\n<p>Relevant uncertainty contributions may include:<\/p>\n<ul>\n<li>Calibration block temperature accuracy<\/li>\n<li>Temperature stability<\/li>\n<li>Temperature uniformity<\/li>\n<li>Reference thermometer calibration uncertainty<\/li>\n<li>Thermometer readout uncertainty<\/li>\n<li>Sensor immersion effects<\/li>\n<li>Thermal contact between the sensor and calibration well<\/li>\n<li>Measurement repeatability<\/li>\n<li>Temperature drift during measurement<\/li>\n<\/ul>\n<p>The individual uncertainty contributions must be evaluated carefully to avoid double-counting effects already included in the manufacturer&#8217;s specifications.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Fluke Calibration 9100S?<\/h2>\n<p>The Fluke Calibration 9100S combines reliable temperature calibration performance with an exceptionally compact and lightweight design.<\/p>\n<p>Its temperature range from +35 \u00b0C to +375 \u00b0C covers numerous industrial and laboratory applications.<\/p>\n<p>Temperature accuracy down to \u00b10.25 \u00b0C and stable temperature control provide reliable conditions for routine sensor calibration.<\/p>\n<p>The instrument weighs only 1 kg, making it particularly suitable for mobile calibration applications.<\/p>\n<p>Fast heating and cooling times help reduce waiting periods between calibration points.<\/p>\n<p>Multiple calibration wells allow different temperature sensors to be calibrated without requiring a liquid bath.<\/p>\n<p>The integrated RS-232 interface provides additional flexibility for computer-assisted calibration procedures.<\/p>\n<p>For calibration technicians, maintenance engineers and industrial users requiring a compact and portable dry block calibrator, the Fluke Calibration 9100S provides an excellent combination of accuracy, efficiency and convenience.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the Fluke Calibration 9100S<\/h2>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Temperature sensor calibration<\/li>\n<li>Pt100 calibration<\/li>\n<li>Pt1000 calibration<\/li>\n<li>RTD calibration<\/li>\n<li>Thermocouple calibration<\/li>\n<li>Bimetal thermometer verification<\/li>\n<li>Temperature indicator testing<\/li>\n<li>Temperature transmitter calibration with external measurement equipment<\/li>\n<li>Industrial process instrumentation<\/li>\n<li>Preventive maintenance<\/li>\n<li>Commissioning<\/li>\n<li>Field calibration<\/li>\n<li>Mobile temperature calibration<\/li>\n<li>Calibration laboratories<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Temperature metrology<\/li>\n<li>Heating system maintenance<\/li>\n<\/ul>\n<p>The combination of a wide temperature range, fast heating performance, compact construction and convenient operation makes the Fluke Calibration 9100S a professional solution for portable temperature calibration.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Find more Fluke Calibration products here.<\/a><\/p>\n<p>Manufacturer information for the Fluke Calibration 9100S can be found on the <a href=\"https:\/\/www.fluke.com\/en-us\/product\/calibration-tools\/temperature-calibrators\/fluke-calibration-9100s\" target=\"_blank\" rel=\"noopener\">official Fluke Calibration website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-Temperaturkalibrierung-Anwendungen-und-L\u00f6sungen.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 9100S<\/strong> is a compact and portable dry block calibrator for temperature sensor calibration. With a range of <strong>35 \u00b0C to 375 \u00b0C<\/strong>, fast heating and a lightweight <strong>1 kg design<\/strong>, it is ideal for calibrating RTDs, thermocouples and small thermometers in the laboratory or directly in the field.<\/p>\n","protected":false},"featured_media":3462,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[1206,53],"product_tag":[6006,6035,6275,3991,6276,6277,3922,3924,6042,3995,6052,6043,3998,4000,4001,4003,6278,4005],"class_list":["post-6907","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-bimetallthermometer-kalibrieren","product_tag-blockkalibrator","product_tag-blockkalibrator-375-c","product_tag-dry-well-kalibrator","product_tag-fluke-9100s","product_tag-fluke-calibration-9100s","product_tag-kalibrierlabor","product_tag-mobiler-kalibrierservice","product_tag-mobiler-temperaturkalibrator","product_tag-pt100-kalibrieren","product_tag-rs232-temperaturkalibrator","product_tag-rtd-kalibrieren","product_tag-temperaturfuehler-kalibrieren","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-thermoelement-kalibrieren","product_tag-tragbarer-blockkalibrator","product_tag-trockenblockkalibrator","pa_bauart-tisch-klein","pa_funktion-heizen-kuehlen","pa_genauigkeit--0-25-c","pa_messbereich-minus-bis-200c","pa_schnittstelle-rs232","pa_stabilitaet-0-05c","pa_strom-versorgung-230-v","pa_temperaturbereich-10c-bis-122c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3462"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6907"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6907"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6907"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}