{"id":6909,"date":"2026-07-17T16:51:01","date_gmt":"2026-07-17T16:51:01","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-9102s-2\/"},"modified":"2026-10-13T09:32:59","modified_gmt":"2026-10-13T09:32:59","slug":"fluke-calibration-9102s-2","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-9102s-2\/","title":{"rendered":"Fluke Calibration 9102S Portable Dry Block Calibrator"},"content":{"rendered":"<p>The <strong>Fluke Calibration 9102S<\/strong> is a compact, portable dry block calibrator designed for accurate temperature sensor calibration in laboratories, industrial facilities and field service applications.<\/p>\n<p>With a temperature range from <strong>\u221210 \u00b0C to +122 \u00b0C<\/strong>, temperature accuracy of <strong>\u00b10.25 \u00b0C<\/strong> and excellent temperature stability of <strong>\u00b10.05 \u00b0C<\/strong>, the Fluke Calibration 9102S provides reliable performance for demanding temperature calibration applications.<\/p>\n<p>The instrument is particularly suitable for calibrating resistance temperature detectors (RTDs), thermocouples, digital thermometers, dial thermometers and temperature switches.<\/p>\n<p>Unlike conventional dry block calibrators designed primarily for high temperatures, the Fluke Calibration 9102S can generate temperatures below ambient temperature.<\/p>\n<p>This makes it especially useful for calibrating temperature sensors used in refrigeration, environmental monitoring, pharmaceutical manufacturing, food processing and industrial temperature measurement.<\/p>\n<p>The Fluke Calibration 9102S features two calibration wells, removable inserts, an RS-232 interface and a compact design weighing only 1.8 kg.<\/p>\n<p>Its ability to operate from an AC power supply or a suitable 12 V DC source provides additional flexibility for mobile calibration applications.<\/p>\n<p>For professional temperature calibration equipment and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Temperature range from \u221210 \u00b0C to +122 \u00b0C<\/li>\n<li>Temperature accuracy of \u00b10.25 \u00b0C<\/li>\n<li>Excellent temperature stability of \u00b10.05 \u00b0C<\/li>\n<li>Suitable for calibration below ambient temperature<\/li>\n<li>Compact and portable construction<\/li>\n<li>Lightweight design weighing only 1.8 kg<\/li>\n<li>Two independent calibration wells<\/li>\n<li>Removable calibration inserts<\/li>\n<li>Calibration well depth of 102 mm<\/li>\n<li>Inserts available from 1.6 mm to 11.1 mm<\/li>\n<li>Two standard inserts included<\/li>\n<li>Fast heating and cooling performance<\/li>\n<li>Heating from ambient temperature to 100 \u00b0C in approximately 10 minutes<\/li>\n<li>Cooling from ambient temperature to 0 \u00b0C in approximately 10 minutes<\/li>\n<li>Typical stabilization time of 7 minutes<\/li>\n<li>Integrated RS-232 communication interface<\/li>\n<li>AC power supply or 12 V DC operation<\/li>\n<li>Suitable for RTDs and Pt100 sensors<\/li>\n<li>Suitable for thermocouples<\/li>\n<li>Suitable for temperature switches<\/li>\n<li>NIST-traceable manufacturer calibration included<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Temperature Range from \u221210 \u00b0C to +122 \u00b0C<\/h2>\n<p>The <strong>Fluke Calibration 9102S<\/strong> provides a temperature calibration range of:<\/p>\n<p><strong>\u221210 \u00b0C to +122 \u00b0C<\/strong><\/p>\n<p>This range is specified at an ambient temperature of 23 \u00b0C.<\/p>\n<p>The ability to generate temperatures below ambient temperature is one of the most important advantages of the instrument.<\/p>\n<p>Many industrial temperature sensors operate in environments where temperatures are close to or below room temperature.<\/p>\n<p>Examples include refrigeration systems, environmental chambers, temperature-controlled storage facilities and industrial cooling processes.<\/p>\n<p>The Fluke Calibration 9102S allows these sensors to be checked without requiring a large laboratory temperature bath.<\/p>\n<p>Typical calibration temperatures include:<\/p>\n<ul>\n<li>\u221210 \u00b0C<\/li>\n<li>0 \u00b0C<\/li>\n<li>10 \u00b0C<\/li>\n<li>20 \u00b0C<\/li>\n<li>25 \u00b0C<\/li>\n<li>50 \u00b0C<\/li>\n<li>75 \u00b0C<\/li>\n<li>100 \u00b0C<\/li>\n<li>122 \u00b0C<\/li>\n<\/ul>\n<p>The achievable minimum temperature depends on the ambient conditions.<\/p>\n<p>For accurate calibration results, sufficient stabilization time must be allowed before recording measurements.<\/p>\n<h2>High Temperature Accuracy of \u00b10.25 \u00b0C<\/h2>\n<p>The Fluke Calibration 9102S provides excellent temperature accuracy for a compact portable dry block calibrator.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.25 \u00b0C<\/strong><\/p>\n<p>This specification describes the temperature accuracy under the manufacturer&#8217;s defined operating conditions.<\/p>\n<p>It must not be confused with temperature stability or the uncertainty stated on an individual calibration certificate.<\/p>\n<p>For demanding comparison calibrations, a suitable external reference thermometer can be used.<\/p>\n<p>The reference thermometer measures the actual temperature within the calibration well.<\/p>\n<p>This allows the device under test to be compared directly with a traceable temperature reference.<\/p>\n<p>The uncertainty of the complete calibration system must be evaluated according to the applicable calibration procedure.<\/p>\n<h2>Excellent Temperature Stability of \u00b10.05 \u00b0C<\/h2>\n<p>The Fluke Calibration 9102S provides excellent temperature stability.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.05 \u00b0C<\/strong><\/p>\n<p>Temperature stability describes the variation of the calibration block temperature over time under defined conditions.<\/p>\n<p>Stable temperature conditions are essential for reliable temperature sensor calibration.<\/p>\n<p>The Fluke Calibration 9102S provides a controlled temperature environment suitable for routine calibration and verification procedures.<\/p>\n<p>For demanding applications, the actual temperature stability should be considered when evaluating the measurement uncertainty.<\/p>\n<h2>Two Calibration Wells<\/h2>\n<p>The Fluke Calibration 9102S features two calibration wells.<\/p>\n<p>Both wells have a nominal diameter of:<\/p>\n<p><strong>12.7 mm (1\/2 inch)<\/strong><\/p>\n<p>The well depth is:<\/p>\n<p><strong>102 mm<\/strong><\/p>\n<p>The two-well design allows a reference thermometer and a device under test to be inserted simultaneously.<\/p>\n<p>This makes the instrument particularly suitable for comparison calibration.<\/p>\n<p>One well can accommodate the reference thermometer, while the second well accommodates the temperature sensor being calibrated.<\/p>\n<p>The manufacturer specifies well-to-well uniformity of:<\/p>\n<p><strong>\u00b10.2 \u00b0C<\/strong><\/p>\n<p>This specification applies when sensors of similar dimensions are inserted to equal depths.<\/p>\n<p>For accurate calibration, the influence of sensor geometry, immersion depth and thermal contact must be considered.<\/p>\n<h2>Removable Calibration Inserts<\/h2>\n<p>The Fluke Calibration 9102S uses removable calibration inserts.<\/p>\n<p>These allow the instrument to accommodate temperature sensors with different diameters.<\/p>\n<p>Available insert diameters include:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Insert Diameter<\/th>\n<th>Imperial Size<\/th>\n<\/tr>\n<tr>\n<td>1.6 mm<\/td>\n<td>1\/16 inch<\/td>\n<\/tr>\n<tr>\n<td>3.2 mm<\/td>\n<td>1\/8 inch<\/td>\n<\/tr>\n<tr>\n<td>4.0 mm<\/td>\n<td>5\/32 inch<\/td>\n<\/tr>\n<tr>\n<td>4.8 mm<\/td>\n<td>3\/16 inch<\/td>\n<\/tr>\n<tr>\n<td>6.4 mm<\/td>\n<td>1\/4 inch<\/td>\n<\/tr>\n<tr>\n<td>7.9 mm<\/td>\n<td>5\/16 inch<\/td>\n<\/tr>\n<tr>\n<td>9.5 mm<\/td>\n<td>3\/8 inch<\/td>\n<\/tr>\n<tr>\n<td>11.1 mm<\/td>\n<td>7\/16 inch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Blank inserts are also available.<\/p>\n<p>The standard configuration includes inserts with diameters of:<\/p>\n<p><strong>4.8 mm and 6.4 mm<\/strong><\/p>\n<p>The appropriate insert should be selected according to the diameter of the temperature sensor.<\/p>\n<p>A small clearance between the sensor and the insert improves thermal contact and reduces measurement errors.<\/p>\n<p>Excessive clearance can increase temperature differences between the calibration block and the sensing element.<\/p>\n<h2>Fast Heating Performance<\/h2>\n<p>The Fluke Calibration 9102S provides efficient heating performance.<\/p>\n<p>The manufacturer specifies a typical heating time of:<\/p>\n<p><strong>10 minutes from ambient temperature to 100 \u00b0C<\/strong><\/p>\n<p>This allows technicians to reach common calibration temperatures quickly.<\/p>\n<p>Short heating times are particularly useful when performing multi-point calibration procedures.<\/p>\n<p>The fast temperature response helps reduce waiting periods and improves calibration efficiency.<\/p>\n<p>Actual heating times depend on ambient conditions, sensor loading and operating conditions.<\/p>\n<h2>Fast Cooling Performance<\/h2>\n<p>The Fluke Calibration 9102S also provides efficient cooling performance.<\/p>\n<p>The manufacturer specifies a typical cooling time of:<\/p>\n<p><strong>10 minutes from ambient temperature to 0 \u00b0C<\/strong><\/p>\n<p>This is particularly useful for temperature sensor calibration below ambient temperature.<\/p>\n<p>The integrated temperature control system allows the instrument to generate both heating and cooling conditions.<\/p>\n<p>This eliminates the need for separate heating and cooling devices for many routine calibration applications.<\/p>\n<h2>Short Stabilization Time<\/h2>\n<p>The Fluke Calibration 9102S features a typical stabilization time of:<\/p>\n<p><strong>7 minutes<\/strong><\/p>\n<p>This describes the time required for the calibration block to stabilize under the manufacturer&#8217;s specified conditions.<\/p>\n<p>The stabilization time of the device under test must also be considered.<\/p>\n<p>Large sensors or sensors with slow thermal response may require additional time before reliable measurements can be recorded.<\/p>\n<p>For demanding calibration procedures, temperature stabilization should be verified using a suitable reference thermometer.<\/p>\n<h2>Compact Portable Construction<\/h2>\n<p>The Fluke Calibration 9102S is designed for mobile temperature calibration.<\/p>\n<p>Its dimensions are:<\/p>\n<p><strong>99 \u00d7 140 \u00d7 175 mm<\/strong><\/p>\n<p>The instrument weighs approximately:<\/p>\n<p><strong>1.8 kg<\/strong><\/p>\n<p>This makes it suitable for transportation between different measurement locations.<\/p>\n<p>The compact design also requires very little space on a laboratory workbench.<\/p>\n<p>The Fluke Calibration 9102S is particularly useful for technicians who need to calibrate temperature sensors directly at the installation site.<\/p>\n<h2>AC and 12 V DC Operation<\/h2>\n<p>The Fluke Calibration 9102S offers flexible power supply options.<\/p>\n<p>The instrument can operate using:<\/p>\n<p><strong>94\u2013234 V AC, 50\/60 Hz<\/strong><\/p>\n<p>or:<\/p>\n<p><strong>12 V DC<\/strong><\/p>\n<p>The rated power consumption is approximately:<\/p>\n<p><strong>60 W<\/strong><\/p>\n<p>The 12 V DC capability provides additional flexibility for mobile applications.<\/p>\n<p>This can be useful when the instrument is operated from a suitable external DC power source.<\/p>\n<p>The power source must meet the manufacturer&#8217;s electrical requirements.<\/p>\n<h2>Calibration of RTDs and Pt100 Sensors<\/h2>\n<p>The Fluke Calibration 9102S is suitable for calibrating resistance temperature detectors.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Pt100 calibration<\/li>\n<li>Pt1000 calibration<\/li>\n<li>Industrial RTD calibration<\/li>\n<li>Temperature probe verification<\/li>\n<li>Temperature indicator testing<\/li>\n<\/ul>\n<p>The RTD sensor is inserted into a suitable calibration insert.<\/p>\n<p>The dry block generates a controlled temperature that can be compared with the temperature indicated by the device under test.<\/p>\n<p>For more demanding applications, an external reference thermometer can be used.<\/p>\n<p>The Fluke Calibration 9102S provides the temperature source but does not directly measure the electrical resistance of the RTD.<\/p>\n<p>A suitable thermometer readout or resistance measurement instrument is required.<\/p>\n<h2>Calibration of Thermocouples<\/h2>\n<p>The Fluke Calibration 9102S can also be used for thermocouple calibration.<\/p>\n<p>Thermocouples are widely used in industrial temperature measurement.<\/p>\n<p>The instrument provides a stable temperature environment for checking thermocouple measurement systems.<\/p>\n<p>The thermocouple is inserted into the calibration block and allowed to stabilize.<\/p>\n<p>Its indicated temperature can then be compared with the reference temperature.<\/p>\n<p>For accurate thermocouple calibration, reference junction compensation and the measurement uncertainty of the readout must be considered.<\/p>\n<h2>Calibration of Digital Thermometers<\/h2>\n<p>The Fluke Calibration 9102S is suitable for checking digital thermometers.<\/p>\n<p>Digital thermometers are commonly used in laboratories, industrial production and quality assurance.<\/p>\n<p>The temperature sensor is inserted into a suitable calibration well.<\/p>\n<p>The thermometer indication is then compared with the reference temperature.<\/p>\n<p>This allows users to verify the measurement performance of the thermometer at several temperature points.<\/p>\n<h2>Calibration of Temperature Switches<\/h2>\n<p>The Fluke Calibration 9102S is also suitable for checking temperature switches.<\/p>\n<p>Temperature switches are used to monitor and control industrial processes.<\/p>\n<p>They activate or deactivate an electrical contact when a defined temperature is reached.<\/p>\n<p>The Fluke Calibration 9102S provides a controlled temperature environment for checking switching points.<\/p>\n<p>The temperature can be increased or decreased to determine the switching temperature.<\/p>\n<p>An external instrument is required to detect the electrical switching signal.<\/p>\n<p>The instrument can also be used to investigate switching hysteresis.<\/p>\n<h2>RS-232 Interface<\/h2>\n<p>The Fluke Calibration 9102S includes an RS-232 communication interface.<\/p>\n<p>This interface allows the instrument to communicate with compatible external equipment.<\/p>\n<p>RS-232 communication can be used for remote operation and integration into suitable calibration systems.<\/p>\n<p>This is particularly useful for laboratories and industrial users who want to incorporate the dry block calibrator into automated or computer-assisted calibration procedures.<\/p>\n<p>The available communication commands and interface settings are described in the manufacturer&#8217;s operating instructions.<\/p>\n<h2>No Calibration Liquid Required<\/h2>\n<p>Unlike liquid calibration baths, the Fluke Calibration 9102S does not require a calibration fluid.<\/p>\n<p>The instrument uses a solid metal block to transfer heat to the temperature sensors.<\/p>\n<p>This provides several practical advantages:<\/p>\n<ul>\n<li>No calibration liquid required<\/li>\n<li>No filling or draining procedures<\/li>\n<li>No risk of calibration fluid leakage<\/li>\n<li>Reduced cleaning requirements<\/li>\n<li>Convenient transportation<\/li>\n<li>Fast preparation for calibration work<\/li>\n<\/ul>\n<p>These advantages make the Fluke Calibration 9102S particularly suitable for field calibration and mobile maintenance applications.<\/p>\n<h2>NIST-Traceable Manufacturer Calibration<\/h2>\n<p>The Fluke Calibration 9102S is supplied with NIST-traceable manufacturer calibration data.<\/p>\n<p>The manufacturer specifies calibration data at seven temperature points:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Calibration Point<\/th>\n<\/tr>\n<tr>\n<td>\u221210 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>0 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>75 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>100 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>122 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These calibration points cover the operating range of the instrument.<\/p>\n<p>Regular recalibration is recommended to verify the long-term performance of the dry block calibrator.<\/p>\n<p>For applications requiring accredited calibration, the availability and scope of the appropriate calibration service should be confirmed separately.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 9102S<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>9102S<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Portable Dry Block Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u221210 \u00b0C to +122 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Reference ambient temperature<\/td>\n<td>23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature accuracy<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.05 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Well-to-well uniformity<\/td>\n<td>\u00b10.2 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Number of calibration wells<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Well diameter<\/td>\n<td>12.7 mm<\/td>\n<\/tr>\n<tr>\n<td>Well depth<\/td>\n<td>102 mm<\/td>\n<\/tr>\n<tr>\n<td>Removable inserts<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Available insert diameters<\/td>\n<td>1.6\u201311.1 mm<\/td>\n<\/tr>\n<tr>\n<td>Standard inserts<\/td>\n<td>4.8 mm and 6.4 mm<\/td>\n<\/tr>\n<tr>\n<td>Heating time, ambient to 100 \u00b0C<\/td>\n<td>10 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, ambient to 0 \u00b0C<\/td>\n<td>10 minutes<\/td>\n<\/tr>\n<tr>\n<td>Typical stabilization time<\/td>\n<td>7 minutes<\/td>\n<\/tr>\n<tr>\n<td>Communication interface<\/td>\n<td>RS-232<\/td>\n<\/tr>\n<tr>\n<td>AC power supply<\/td>\n<td>94\u2013234 V AC, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>DC power supply<\/td>\n<td>12 V DC<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>60 W<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (H \u00d7 W \u00d7 D)<\/td>\n<td>99 \u00d7 140 \u00d7 175 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 1.8 kg<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer calibration<\/td>\n<td>NIST-traceable<\/td>\n<\/tr>\n<tr>\n<td>Calibration points<\/td>\n<td>\u221210, 0, 25, 50, 75, 100 and 122 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Typical applications<\/td>\n<td>RTD, thermocouple and thermometer calibration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 9102S or 9100S?<\/h2>\n<p>The Fluke Calibration 9102S and 9100S are both compact handheld dry block calibrators.<\/p>\n<p>However, they are designed for different temperature ranges.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 9102S<\/th>\n<th>Fluke Calibration 9100S<\/th>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u221210 \u00b0C to +122 \u00b0C<\/td>\n<td>+35 \u00b0C to +375 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature accuracy<\/td>\n<td>\u00b10.25 \u00b0C<\/td>\n<td>\u00b10.25 \u00b0C to \u00b10.5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.05 \u00b0C<\/td>\n<td>\u00b10.07 \u00b0C to \u00b10.3 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Number of wells<\/td>\n<td>2<\/td>\n<td>Multiple fixed wells<\/td>\n<\/tr>\n<tr>\n<td>Well depth<\/td>\n<td>102 mm<\/td>\n<td>102 mm<\/td>\n<\/tr>\n<tr>\n<td>Removable inserts<\/td>\n<td>Yes<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>1.8 kg<\/td>\n<td>1 kg<\/td>\n<\/tr>\n<tr>\n<td>RS-232 interface<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>12 V DC operation<\/td>\n<td>Yes<\/td>\n<td>No<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The <strong>Fluke Calibration 9102S<\/strong> is particularly suitable for applications requiring temperatures below ambient temperature.<\/p>\n<p>The <strong>Fluke Calibration 9100S<\/strong> is designed for applications requiring temperatures up to 375 \u00b0C.<\/p>\n<p>The correct model should be selected according to the required temperature range, sensor dimensions and calibration uncertainty.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and calibration equipment.<\/p>\n<p>When the Fluke Calibration 9102S is used for temperature sensor calibration, the measurement uncertainty must be evaluated according to the complete measurement procedure.<\/p>\n<p>Relevant uncertainty contributions may include:<\/p>\n<ul>\n<li>Calibration block temperature accuracy<\/li>\n<li>Temperature stability<\/li>\n<li>Temperature uniformity<\/li>\n<li>Reference thermometer calibration uncertainty<\/li>\n<li>Thermometer readout uncertainty<\/li>\n<li>Sensor immersion effects<\/li>\n<li>Thermal contact between the sensor and calibration insert<\/li>\n<li>Measurement repeatability<\/li>\n<li>Temperature drift during measurement<\/li>\n<\/ul>\n<p>The individual uncertainty contributions must be evaluated carefully to avoid double-counting effects already included in the manufacturer&#8217;s specifications.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Fluke Calibration 9102S?<\/h2>\n<p>The Fluke Calibration 9102S combines accurate temperature calibration performance with compact and portable construction.<\/p>\n<p>Its temperature range from \u221210 \u00b0C to +122 \u00b0C covers numerous industrial and laboratory applications.<\/p>\n<p>The ability to generate temperatures below ambient temperature makes it particularly suitable for refrigeration, environmental monitoring and temperature-controlled processes.<\/p>\n<p>Temperature accuracy of \u00b10.25 \u00b0C and stability of \u00b10.05 \u00b0C provide reliable conditions for routine sensor calibration.<\/p>\n<p>The instrument weighs only 1.8 kg, making it suitable for mobile calibration applications.<\/p>\n<p>Two calibration wells allow a reference thermometer and a device under test to be used simultaneously.<\/p>\n<p>Removable inserts provide flexibility when calibrating sensors with different diameters.<\/p>\n<p>Fast heating and cooling times help reduce waiting periods between calibration points.<\/p>\n<p>The integrated RS-232 interface and optional 12 V DC operation provide additional flexibility for field and laboratory applications.<\/p>\n<p>For calibration technicians, maintenance engineers and industrial users requiring a portable low-temperature dry block calibrator, the Fluke Calibration 9102S provides an excellent combination of accuracy, efficiency and convenience.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the Fluke Calibration 9102S<\/h2>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Temperature sensor calibration<\/li>\n<li>Pt100 calibration<\/li>\n<li>Pt1000 calibration<\/li>\n<li>RTD calibration<\/li>\n<li>Thermocouple calibration<\/li>\n<li>Digital thermometer verification<\/li>\n<li>Dial thermometer calibration<\/li>\n<li>Temperature switch testing<\/li>\n<li>Refrigeration system maintenance<\/li>\n<li>Environmental monitoring<\/li>\n<li>Temperature-controlled storage<\/li>\n<li>Pharmaceutical manufacturing<\/li>\n<li>Food processing<\/li>\n<li>Industrial process instrumentation<\/li>\n<li>Preventive maintenance<\/li>\n<li>Commissioning<\/li>\n<li>Field calibration<\/li>\n<li>Calibration laboratories<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Temperature metrology<\/li>\n<\/ul>\n<p>The combination of excellent temperature stability, low-temperature capability, removable inserts and portable construction makes the Fluke Calibration 9102S a professional solution for demanding temperature calibration applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Find more Fluke Calibration products here.<\/a><\/p>\n<p>Manufacturer information for the Fluke Calibration 9102S can be found on the <a href=\"https:\/\/www.fluke.com\/en-gb\/product\/calibration-tools\/temperature-calibrators\/fluke-calibration-9102s\" target=\"_blank\" rel=\"noopener\">official Fluke Calibration website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-Temperaturkalibrierung-Anwendungen-und-L\u00f6sungen.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 9102S<\/strong> is a compact and portable dry block calibrator for professional temperature sensor calibration. With a temperature range of <strong>\u221210 \u00b0C to +122 \u00b0C<\/strong>, accuracy of <strong>\u00b10.25 \u00b0C<\/strong> and stability of <strong>\u00b10.05 \u00b0C<\/strong>, it provides reliable performance for laboratory and field applications.\u00a0Featuring two calibration wells, interchangeable inserts, fast heating and cooling, and a lightweight <strong>1.8 kg design<\/strong>, it is ideal for calibrating RTDs, thermocouples, digital thermometers and temperature switches.<\/p>\n","protected":false},"featured_media":3463,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[1206,53],"product_tag":[6280,6035,6281,6282,6283,6284,3922,6041,3995,4751,6043,3999,4000,4001,6285,5980,4005],"class_list":["post-6909","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-12-v-temperaturkalibrator","product_tag-blockkalibrator","product_tag-blockkalibrator-minus-10-c","product_tag-fluke-9102s","product_tag-fluke-calibration-9102s","product_tag-handheld-dry-well","product_tag-kalibrierlabor","product_tag-mobiler-blockkalibrator","product_tag-pt100-kalibrieren","product_tag-rs232-kalibrator","product_tag-rtd-kalibrieren","product_tag-temperaturkalibrator","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-temperaturschalter-kalibrieren","product_tag-thermometer-kalibrieren","product_tag-trockenblockkalibrator","pa_bauart-tisch","pa_funktion-nur-heizen","pa_genauigkeit-05-c","pa_messbereich-375c","pa_schnittstelle-rs232","pa_stabilitaet-005-c","pa_strom-versorgung-230-v","pa_temperaturbereich-35-bis-350-c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6909","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3463"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6909"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6909"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6909"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6909"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}