{"id":6946,"date":"2026-07-17T16:52:24","date_gmt":"2026-07-17T16:52:24","guid":{"rendered":"https:\/\/europascal.de\/product\/ametek-rtc-168\/"},"modified":"2026-10-13T11:52:06","modified_gmt":"2026-10-13T11:52:06","slug":"ametek-rtc-168","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/ametek-rtc-168\/","title":{"rendered":"AMETEK RTC-168 Versatile Temperature Calibrator"},"content":{"rendered":"<p>The <strong>AMETEK RTC-168<\/strong> is a professional reference temperature calibrator combining the advantages of a dry block calibrator and a liquid temperature bath in one portable instrument.<\/p>\n<p>With a temperature range from <strong>\u221230 \u00b0C to +165 \u00b0C<\/strong>, excellent temperature stability of <strong>\u00b10.01 \u00b0C<\/strong> and a specified accuracy of <strong>\u00b10.045 \u00b0C with a suitable external reference thermometer<\/strong>, the AMETEK RTC-168 provides outstanding performance for demanding temperature calibration applications.<\/p>\n<p>The instrument has been developed particularly for the calibration of sanitary temperature sensors used in pharmaceutical manufacturing, biotechnology, food processing and other hygienic production environments.<\/p>\n<p>Its innovative design allows the calibration of short temperature sensors, sensors with large process connections and sensors with unusual geometries.<\/p>\n<p>The AMETEK RTC-168 features a large calibration well, active dual zone temperature control, optional Dynamic Load Compensation and interchangeable calibration inserts.<\/p>\n<p>An innovative removable liquid container allows users to switch conveniently between dry block calibration and liquid bath calibration.<\/p>\n<p>This flexibility makes the AMETEK RTC-168 an excellent solution for calibration laboratories, industrial maintenance departments and professional temperature metrology applications.<\/p>\n<p>europascal supports customers with professional calibration equipment, technical advice and suitable calibration services.<\/p>\n<p>For additional information about traceable calibration, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The AMETEK RTC-168 combines excellent temperature calibration performance with outstanding flexibility.<\/p>\n<p>Its main advantages include:<\/p>\n<ul>\n<li>Temperature range from \u221230 \u00b0C to +165 \u00b0C<\/li>\n<li>Combined dry block and liquid bath calibration<\/li>\n<li>Excellent temperature stability of \u00b10.01 \u00b0C<\/li>\n<li>Accuracy of \u00b10.045 \u00b0C with a suitable external reference thermometer<\/li>\n<li>Internal reference accuracy of \u00b10.18 \u00b0C in dry block mode<\/li>\n<li>Innovative removable liquid container<\/li>\n<li>Suitable for sanitary temperature sensors<\/li>\n<li>Calibration of sensors with flanges up to 84 mm<\/li>\n<li>Large calibration well with a diameter of 63.5 mm<\/li>\n<li>Calibration well depth of 160 mm<\/li>\n<li>Active dual zone temperature control<\/li>\n<li>Optional Dynamic Load Compensation<\/li>\n<li>Excellent radial temperature homogeneity<\/li>\n<li>Special calibration inserts for short sensors<\/li>\n<li>Intelligent external reference thermometers<\/li>\n<li>Automatic temperature stepping<\/li>\n<li>Integrated stability monitoring<\/li>\n<li>Optional sensor under test measurement<\/li>\n<li>Optional temperature switch testing<\/li>\n<li>USB communication interface<\/li>\n<li>Compatible with JofraCal calibration software<\/li>\n<li>Portable construction<\/li>\n<li>Ideal for pharmaceutical and food industry applications<\/li>\n<\/ul>\n<h2>Ideal for Demanding Temperature Calibration Applications<\/h2>\n<p>The AMETEK RTC-168 is particularly suitable for applications where conventional dry block calibrators reach their limitations.<\/p>\n<p>Many industrial temperature sensors feature long cylindrical probes that can easily be inserted into a standard calibration block.<\/p>\n<p>However, sanitary temperature sensors frequently have short sensing elements, large flanges or special process connections.<\/p>\n<p>These designs are necessary to meet hygienic requirements but can make accurate temperature calibration difficult.<\/p>\n<p>The AMETEK RTC-168 addresses these challenges through its large calibration opening and specially designed calibration accessories.<\/p>\n<p>The instrument allows the sensing element of short sensors to reach the temperature homogeneous calibration zone.<\/p>\n<p>This helps reduce errors caused by insufficient immersion depth and heat conduction through the sensor housing.<\/p>\n<p>Typical applications include pharmaceutical manufacturing, biotechnology, food processing, hygienic process engineering and calibration laboratories.<\/p>\n<h2>Temperature Range from \u221230 \u00b0C to +165 \u00b0C<\/h2>\n<p>The <strong>AMETEK RTC-168<\/strong> provides a temperature range from:<\/p>\n<p><strong>\u221230 \u00b0C to +165 \u00b0C<\/strong><\/p>\n<p>This range applies to the standard dry block and liquid bath configurations at an ambient temperature of 23 \u00b0C.<\/p>\n<p>The instrument can therefore generate temperatures below and above normal ambient conditions.<\/p>\n<p>Typical calibration points include:<\/p>\n<ul>\n<li>\u221230 \u00b0C<\/li>\n<li>\u221220 \u00b0C<\/li>\n<li>0 \u00b0C<\/li>\n<li>20 \u00b0C<\/li>\n<li>50 \u00b0C<\/li>\n<li>80 \u00b0C<\/li>\n<li>100 \u00b0C<\/li>\n<li>121 \u00b0C<\/li>\n<li>140 \u00b0C<\/li>\n<li>165 \u00b0C<\/li>\n<\/ul>\n<p>These temperatures cover numerous industrial and laboratory applications.<\/p>\n<p>For example, 121 \u00b0C is an important temperature in many sterilization processes.<\/p>\n<p>The AMETEK RTC-168 can be used to verify temperature sensors employed in such processes.<\/p>\n<p>When the removable liquid container is used, the available temperature range differs slightly.<\/p>\n<p>At 23 \u00b0C ambient temperature, the specified range for this configuration is:<\/p>\n<p><strong>\u221226 \u00b0C to +160 \u00b0C<\/strong><\/p>\n<p>The appropriate configuration must therefore be selected according to the required calibration temperature.<\/p>\n<h2>Excellent Temperature Accuracy<\/h2>\n<p>The AMETEK RTC-168 provides different accuracy specifications depending on the selected operating mode and reference thermometer.<\/p>\n<h3>Accuracy with Internal Reference<\/h3>\n<p>In dry block mode, the manufacturer specifies:<\/p>\n<p><strong>\u00b10.18 \u00b0C<\/strong><\/p>\n<p>This value applies when the instrument is calibrated and operated with the appropriate insert.<\/p>\n<p>In liquid bath mode, the internal reference accuracy depends on the calibration configuration.<\/p>\n<p>When calibrated with the insert, the manufacturer specifies \u00b10.21 \u00b0C.<\/p>\n<p>When calibrated directly in liquid bath mode, the specified value is \u00b10.14 \u00b0C.<\/p>\n<h3>Accuracy with External Reference<\/h3>\n<p>When using the specified external STS-200 reference thermometer, the manufacturer specifies:<\/p>\n<p><strong>\u00b10.045 \u00b0C<\/strong><\/p>\n<p>This value applies to the supported dry block and liquid bath configurations.<\/p>\n<p>The external reference thermometer measures the temperature within the calibration zone.<\/p>\n<p>This allows accurate comparison measurements between the reference thermometer and the device under test.<\/p>\n<p>The specified accuracy must not be confused with the expanded measurement uncertainty stated on an individual calibration certificate.<\/p>\n<h2>Excellent Temperature Stability of \u00b10.01 \u00b0C<\/h2>\n<p>The AMETEK RTC-168 provides outstanding temperature stability.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u00b10.01 \u00b0C<\/strong><\/p>\n<p>This specification applies to dry block operation, liquid bath operation and the removable liquid container configuration.<\/p>\n<p>Temperature stability describes the variation of the calibration temperature over time under defined conditions.<\/p>\n<p>The manufacturer evaluates stability after the stability indicator has been active for 15 minutes, followed by a 30 minute measurement period.<\/p>\n<p>Excellent stability is particularly important when calibrating precision resistance thermometers and demanding industrial temperature sensors.<\/p>\n<p>Stable calibration conditions help minimize measurement variations and support reliable calibration results.<\/p>\n<h2>Combined Dry Block and Liquid Bath Calibration<\/h2>\n<p>One of the most important advantages of the AMETEK RTC-168 is its ability to operate as both a dry block calibrator and a liquid bath calibrator.<\/p>\n<h3>Dry Block Calibration<\/h3>\n<p>In dry block mode, the temperature sensor is inserted into a suitable metal calibration insert.<\/p>\n<p>The insert provides thermal contact between the calibration block and the sensor.<\/p>\n<p>This method is particularly convenient for conventional cylindrical temperature probes.<\/p>\n<p>Advantages include clean operation, easy handling and reproducible sensor positioning.<\/p>\n<h3>Liquid Bath Calibration<\/h3>\n<p>In liquid bath mode, a suitable calibration liquid transfers heat to the temperature sensors.<\/p>\n<p>This provides greater flexibility when calibrating sensors with unusual shapes or dimensions.<\/p>\n<p>Liquid calibration is particularly useful for short sensors and sensors that cannot be accommodated in conventional inserts.<\/p>\n<p>The AMETEK RTC-168 allows users to select the most suitable calibration method for each application.<\/p>\n<h2>Innovative Removable Liquid Container<\/h2>\n<p>The AMETEK RTC-168 features an innovative removable liquid container.<\/p>\n<p>This allows users to switch between liquid bath calibration and dry block calibration without draining the entire calibration well.<\/p>\n<p>The calibration liquid is placed inside the removable container.<\/p>\n<p>After completing the liquid calibration, the container can be removed.<\/p>\n<p>The instrument can then be used again as a dry block calibrator.<\/p>\n<p>The container includes a threaded lid with an integrated pressure relief valve.<\/p>\n<p>This simplifies transportation and storage of the calibration liquid.<\/p>\n<p>When using the removable liquid container, the manufacturer requires a suitable external reference thermometer and activation of the Set Follows True function.<\/p>\n<p>These capabilities are available with the RTC-168B and RTC-168C configurations.<\/p>\n<h2>Calibration of Sanitary Temperature Sensors<\/h2>\n<p>The AMETEK RTC-168 is specifically designed for sanitary temperature sensor calibration.<\/p>\n<p>Sanitary sensors are widely used in pharmaceutical manufacturing, biotechnology and food processing.<\/p>\n<p>They often feature short sensing elements and large hygienic process connections.<\/p>\n<p>These geometries can make conventional temperature calibration difficult.<\/p>\n<p>The AMETEK RTC-168 provides a specially designed calibration area that allows sensors with flange diameters up to:<\/p>\n<p><strong>84 mm<\/strong><\/p>\n<p>to be accommodated.<\/p>\n<p>The large opening helps position the sensing element within the homogeneous temperature zone.<\/p>\n<p>Special inserts and adapters are available for different sensor geometries.<\/p>\n<p>This makes the instrument particularly suitable for hygienic temperature sensors used in critical industrial processes.<\/p>\n<h2>Large Calibration Well<\/h2>\n<p>The AMETEK RTC-168 features a large calibration well.<\/p>\n<p>The nominal well diameter is:<\/p>\n<p><strong>63.5 mm<\/strong><\/p>\n<p>The well depth is:<\/p>\n<p><strong>160 mm<\/strong><\/p>\n<p>This large calibration area provides excellent flexibility.<\/p>\n<p>It allows several temperature sensors to be inserted simultaneously when a suitable multi hole insert is used.<\/p>\n<p>The large diameter also makes it possible to accommodate sensors that cannot be calibrated in conventional compact dry block calibrators.<\/p>\n<p>For dry block applications, different inserts are available according to the dimensions of the devices under test.<\/p>\n<h2>Active Dual Zone Temperature Control<\/h2>\n<p>The AMETEK RTC-168 features active dual zone temperature control.<\/p>\n<p>This technology uses independently controlled temperature zones to improve temperature homogeneity.<\/p>\n<p>The lower zone provides precise temperature control within the calibration area.<\/p>\n<p>The upper zone compensates for heat losses caused by the open calibration well and the inserted temperature sensors.<\/p>\n<p>This reduces temperature gradients and improves calibration conditions.<\/p>\n<p>Active dual zone control is particularly beneficial when calibrating sensors with short sensing elements or different immersion depths.<\/p>\n<p>It also supports accurate calibration when multiple sensors are inserted simultaneously.<\/p>\n<h2>Dynamic Load Compensation<\/h2>\n<p>The AMETEK RTC-168 supports Dynamic Load Compensation, also known as DLC.<\/p>\n<p>This patented technology helps compensate for temperature distribution changes caused by the inserted sensors.<\/p>\n<p>When several sensors are inserted into a calibration block, they can influence the temperature distribution.<\/p>\n<p>Large sensors and sensors with different thermal characteristics may create additional temperature gradients.<\/p>\n<p>The DLC system uses a special differential temperature sensor to monitor the temperature distribution within the calibration insert.<\/p>\n<p>The calibrator then adjusts the temperature control to reduce the detected differences.<\/p>\n<p>This provides improved temperature homogeneity under different loading conditions.<\/p>\n<p>Dynamic Load Compensation is particularly useful for demanding dry block comparison calibrations.<\/p>\n<p>The manufacturer specifies that DLC functionality cannot be used when calibrating sanitary sensors.<\/p>\n<h2>Excellent Temperature Homogeneity<\/h2>\n<p>The AMETEK RTC-168 provides excellent radial temperature homogeneity.<\/p>\n<p>In dry block mode, the manufacturer specifies:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature<\/th>\n<th>Radial Homogeneity<\/th>\n<\/tr>\n<tr>\n<td>\u221230 \u00b0C<\/td>\n<td>0.02 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>+165 \u00b0C<\/td>\n<td>0.03 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>In liquid bath mode, the manufacturer specifies:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature Range<\/th>\n<th>Radial Homogeneity<\/th>\n<\/tr>\n<tr>\n<td>\u221230 \u00b0C to \u221220 \u00b0C<\/td>\n<td>0.029 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u221220 \u00b0C to +165 \u00b0C<\/td>\n<td>0.015 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These values demonstrate the excellent temperature distribution of the calibration system.<\/p>\n<p>Good temperature homogeneity is essential for accurate comparison calibration.<\/p>\n<p>The actual calibration uncertainty also depends on sensor geometry, immersion depth, loading and thermal contact.<\/p>\n<h2>Fast Heating and Cooling<\/h2>\n<p>The AMETEK RTC-168 provides efficient temperature changes.<\/p>\n<p>Typical heating times include:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature Change<\/th>\n<th>Heating Time<\/th>\n<\/tr>\n<tr>\n<td>\u221230 \u00b0C to +23 \u00b0C<\/td>\n<td>4 minutes<\/td>\n<\/tr>\n<tr>\n<td>+23 \u00b0C to +100 \u00b0C<\/td>\n<td>9 minutes<\/td>\n<\/tr>\n<tr>\n<td>+100 \u00b0C to +165 \u00b0C<\/td>\n<td>11 minutes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Typical cooling times include:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature Change<\/th>\n<th>Cooling Time<\/th>\n<\/tr>\n<tr>\n<td>+165 \u00b0C to +100 \u00b0C<\/td>\n<td>12 minutes<\/td>\n<\/tr>\n<tr>\n<td>+100 \u00b0C to +23 \u00b0C<\/td>\n<td>22 minutes<\/td>\n<\/tr>\n<tr>\n<td>+23 \u00b0C to 0 \u00b0C<\/td>\n<td>13 minutes<\/td>\n<\/tr>\n<tr>\n<td>0 \u00b0C to \u221215 \u00b0C<\/td>\n<td>17 minutes<\/td>\n<\/tr>\n<tr>\n<td>\u221215 \u00b0C to \u221230 \u00b0C<\/td>\n<td>42 minutes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Fast temperature changes help reduce waiting times during multi point calibration procedures.<\/p>\n<p>The actual heating and cooling times depend on ambient conditions and the selected operating configuration.<\/p>\n<h2>Three Available Configurations<\/h2>\n<p>The AMETEK RTC-168 is available in three configurations.<\/p>\n<h3>AMETEK RTC-168A<\/h3>\n<p>The RTC-168A provides temperature generation and control using the internal reference thermometer.<\/p>\n<p>It is suitable for applications where external reference thermometers and measurement instruments are already available.<\/p>\n<h3>AMETEK RTC-168B<\/h3>\n<p>The RTC-168B provides the most comprehensive measurement functionality.<\/p>\n<p>It includes an external reference thermometer input and integrated measurement functions for compatible devices under test.<\/p>\n<p>These include RTDs, thermocouples, temperature transmitters and temperature switches.<\/p>\n<p>The RTC-168B is particularly suitable for automated calibration procedures.<\/p>\n<h3>AMETEK RTC-168C<\/h3>\n<p>The RTC-168C includes an external reference thermometer input.<\/p>\n<p>It is designed for accurate comparison calibrations using a suitable external reference sensor.<\/p>\n<p>Unlike the RTC-168B, it does not include the complete sensor under test measurement functionality.<\/p>\n<h2>Automatic Temperature Stepping<\/h2>\n<p>The AMETEK RTC-168 supports automatic temperature stepping.<\/p>\n<p>Users can program up to 20 temperature steps.<\/p>\n<p>Each step can include a defined temperature setpoint and holding time.<\/p>\n<p>The calibrator automatically processes the programmed sequence.<\/p>\n<p>This is particularly useful for repetitive calibration procedures.<\/p>\n<p>Automatic stepping helps reduce manual intervention and improves the consistency of calibration processes.<\/p>\n<h2>USB Communication and Calibration Software<\/h2>\n<p>The AMETEK RTC-168 features a USB communication interface.<\/p>\n<p>The instrument can communicate with compatible calibration software.<\/p>\n<p>JofraCal calibration software supports the calibration and documentation of temperature sensors, transmitters and temperature switches.<\/p>\n<p>Depending on the instrument configuration, calibration procedures can be performed manually or with integrated measurement functions.<\/p>\n<p>Computer assisted calibration helps improve efficiency and simplifies documentation.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>AMETEK RTC-168<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>AMETEK<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>RTC-168<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Reference Temperature Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Calibration methods<\/td>\n<td>Dry Block and Liquid Bath<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u221230 \u00b0C to +165 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature range with removable container at 23 \u00b0C ambient<\/td>\n<td>\u221226 \u00b0C to +160 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Internal accuracy in dry block mode<\/td>\n<td>\u00b10.18 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy with external STS-200 reference<\/td>\n<td>\u00b10.045 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial homogeneity at \u221230 \u00b0C, dry block<\/td>\n<td>0.02 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial homogeneity at +165 \u00b0C, dry block<\/td>\n<td>0.03 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>1 \u00b0C, 0.1 \u00b0C, 0.01 \u00b0C or 0.001 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Well diameter<\/td>\n<td>63.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Well depth<\/td>\n<td>160 mm<\/td>\n<\/tr>\n<tr>\n<td>Immersion depth including insulation plug<\/td>\n<td>180 mm<\/td>\n<\/tr>\n<tr>\n<td>Liquid bath immersion depth<\/td>\n<td>150 mm<\/td>\n<\/tr>\n<tr>\n<td>Maximum sanitary sensor flange diameter<\/td>\n<td>84 mm<\/td>\n<\/tr>\n<tr>\n<td>Temperature control<\/td>\n<td>Active Dual Zone<\/td>\n<\/tr>\n<tr>\n<td>Dynamic Load Compensation<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Removable liquid container<\/td>\n<td>Available<\/td>\n<\/tr>\n<tr>\n<td>External reference input<\/td>\n<td>Models B and C<\/td>\n<\/tr>\n<tr>\n<td>Sensor under test input<\/td>\n<td>Model B<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td>USB 2.0<\/td>\n<\/tr>\n<tr>\n<td>Calibration software<\/td>\n<td>JofraCal<\/td>\n<\/tr>\n<tr>\n<td>Operating ambient temperature<\/td>\n<td>0 \u00b0C to +40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>115 V or 230 V AC versions<\/td>\n<\/tr>\n<tr>\n<td>Maximum power consumption<\/td>\n<td>500 VA<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>366 \u00d7 171 \u00d7 363 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approximately 10.9 kg<\/td>\n<\/tr>\n<tr>\n<td>Protection rating<\/td>\n<td>IP10<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and calibration equipment.<\/p>\n<p>When the AMETEK RTC-168 is used for temperature sensor calibration, the measurement uncertainty must be evaluated according to the complete calibration procedure.<\/p>\n<p>Relevant uncertainty contributions include temperature stability, axial and radial temperature distribution, reference thermometer uncertainty, sensor immersion depth, loading effects and measurement repeatability.<\/p>\n<p>For liquid bath calibration, additional influences such as liquid properties, stirring conditions and temperature distribution must be considered.<\/p>\n<p>For dry block calibration, thermal contact between the sensor and calibration insert is particularly important.<\/p>\n<p>A suitable uncertainty budget helps ensure that calibration results are reliable and metrologically traceable.<\/p>\n<p>For professional calibration services, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the AMETEK RTC-168?<\/h2>\n<p>The AMETEK RTC-168 combines the advantages of two temperature calibration methods in one professional instrument.<\/p>\n<p>Its temperature range from \u221230 \u00b0C to +165 \u00b0C covers numerous industrial and laboratory applications.<\/p>\n<p>Excellent temperature stability of \u00b10.01 \u00b0C provides reliable conditions for precision calibration.<\/p>\n<p>The ability to operate as both a dry block calibrator and a liquid bath offers exceptional flexibility.<\/p>\n<p>The large calibration well and special sanitary sensor inserts make it possible to calibrate short sensors and sensors with large process connections.<\/p>\n<p>Active dual zone temperature control and optional Dynamic Load Compensation help improve temperature homogeneity.<\/p>\n<p>The removable liquid container simplifies switching between calibration methods.<\/p>\n<p>Depending on the selected configuration, integrated reference thermometer and sensor measurement functions support efficient calibration procedures.<\/p>\n<p>For pharmaceutical manufacturers, food processing companies, calibration laboratories and industrial users requiring flexible temperature calibration equipment, the AMETEK RTC-168 provides an excellent combination of accuracy, versatility and efficiency.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the AMETEK RTC-168<\/h2>\n<p>The AMETEK RTC-168 is suitable for numerous professional temperature calibration applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Sanitary temperature sensor calibration<\/li>\n<li>Pharmaceutical manufacturing<\/li>\n<li>Biotechnology<\/li>\n<li>Food and beverage processing<\/li>\n<li>Hygienic process instrumentation<\/li>\n<li>Pt100 calibration<\/li>\n<li>Pt1000 calibration<\/li>\n<li>RTD calibration<\/li>\n<li>Thermocouple calibration<\/li>\n<li>Temperature transmitter calibration<\/li>\n<li>Temperature switch testing<\/li>\n<li>Precision thermometer calibration<\/li>\n<li>Liquid bath calibration<\/li>\n<li>Dry block calibration<\/li>\n<li>Calibration of short temperature sensors<\/li>\n<li>Calibration of sensors with large flanges<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Calibration laboratories<\/li>\n<li>Temperature metrology<\/li>\n<li>Field calibration<\/li>\n<\/ul>\n<p>The combination of excellent temperature stability, flexible calibration methods, advanced temperature control and innovative sanitary sensor accessories makes the AMETEK RTC-168 a professional solution for demanding temperature calibration applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/en\/\">Find more AMETEK calibration equipment at europascal.<\/a><\/p>\n<p>Manufacturer information for the AMETEK RTC-168 can be found on the <a href=\"https:\/\/www.ametekcalibration.com\/products\/temperature\/temperature-calibrators\/rtc-series-reference-temperature-calibrator\" target=\"_blank\" rel=\"noopener\">official AMETEK website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Ametek-RTC-168-Sanitary-Sensor-Temperature-Calibrator.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>AMETEK RTC-168<\/strong> is a versatile reference temperature calibrator combining dry block and liquid bath calibration in one portable instrument. With a temperature range from <strong>\u221230 \u00b0C to +165 \u00b0C<\/strong>, stability of <strong>\u00b10.01 \u00b0C<\/strong> and accuracy of <strong>\u00b10.045 \u00b0C with an external reference thermometer<\/strong>, it is ideal for calibrating RTDs, thermocouples and sanitary temperature sensors in laboratories and industrial applications.<\/p>\n","protected":false},"featured_media":6947,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[92],"product_cat":[55,1206,53],"product_tag":[5819,6385,5843,4125,6386,6387,3922,3995,6375,6388,6389,5824,3998,3999,4001,4003,4005],"class_list":["post-6946","product","type-product","status-publish","has-post-thumbnail","product_brand-ametek","product_cat-liquid-bath-micro-bath","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-ametek-jofra","product_tag-ametek-rtc-168","product_tag-dlc-dynamic-load-compensation","product_tag-fluessigkeitsbad","product_tag-hygienesensor-kalibrieren","product_tag-jofra-rtc-168","product_tag-kalibrierlabor","product_tag-pt100-kalibrieren","product_tag-referenztemperaturkalibrator","product_tag-rtc-168","product_tag-sanitary-sensor","product_tag-temperatur-kalibrierung","product_tag-temperaturfuehler-kalibrieren","product_tag-temperaturkalibrator","product_tag-temperaturmesstechnik","product_tag-thermoelement-kalibrieren","product_tag-trockenblockkalibrator","pa_bauart-tisch","pa_funktion-heizen-kuehlen","pa_genauigkeit-030-c","pa_kanaele-t-eingaengen-fuer-den-referenzsensor-den-dlc-sensor-sowie-die-prueflinge-schaltertest","pa_messbereich-minus-bis-200c","pa_schnittstelle-usb","pa_stabilitaet-003-c","pa_strom-versorgung-230v","pa_temperaturbereich-100-c-bis-155-c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6946","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6947"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6946"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6946"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6946"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6946"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}