{"id":6949,"date":"2026-07-17T16:53:14","date_gmt":"2026-07-17T16:53:14","guid":{"rendered":"https:\/\/europascal.de\/product\/ametek-mtc-650\/"},"modified":"2026-10-14T08:53:06","modified_gmt":"2026-10-14T08:53:06","slug":"ametek-mtc-650","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/ametek-mtc-650\/","title":{"rendered":"AMETEK MTC-650 Robust Marine Temperature Calibrator"},"content":{"rendered":"<p>The <strong>AMETEK MTC-650<\/strong> is a professional marine temperature calibrator designed for accurate, reliable and efficient temperature sensor calibration in maritime environments, industrial facilities and calibration laboratories.<\/p>\n<p>With a temperature range from <strong>28 \u00b0C to 650 \u00b0C<\/strong>, temperature stability of <strong>\u00b10.1 \u00b0C<\/strong> and a one year accuracy specification of <strong>\u00b10.9 \u00b0C<\/strong>, the AMETEK MTC-650 provides dependable performance for demanding temperature calibration applications.<\/p>\n<p>The instrument combines a robust construction with fast heating technology, intuitive operation and advanced temperature control.<\/p>\n<p>With a heating time of approximately <strong>18 minutes from 23 \u00b0C to 650 \u00b0C<\/strong>, the AMETEK MTC-650 significantly reduces waiting times during calibration procedures.<\/p>\n<p>The calibrator is particularly suitable for calibrating resistance temperature detectors, Pt100 sensors, thermocouples, temperature switches and industrial temperature measuring instruments.<\/p>\n<p>Its compact design, interchangeable calibration inserts, automatic temperature stepping and USB communication interface make it ideal for maintenance technicians and calibration specialists.<\/p>\n<p>The AMETEK MTC-650 was specifically developed for applications aboard ships and offshore installations.<\/p>\n<p>Its DNV type approval makes it particularly suitable for maritime calibration applications.<\/p>\n<p>europascal provides professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<p>For more information, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The AMETEK MTC-650 combines accurate temperature generation with reliable operation and convenient handling.<\/p>\n<p>Its main advantages include:<\/p>\n<ul>\n<li>Temperature range from 28 \u00b0C to 650 \u00b0C<\/li>\n<li>One year temperature accuracy of \u00b10.9 \u00b0C<\/li>\n<li>Three year temperature accuracy of \u00b11.8 \u00b0C<\/li>\n<li>Excellent temperature stability of \u00b10.1 \u00b0C<\/li>\n<li>Radial temperature homogeneity of 0.1 \u00b0C<\/li>\n<li>Fast heating to 650 \u00b0C in approximately 18 minutes<\/li>\n<li>Cooling from 650 \u00b0C to 100 \u00b0C in approximately 39 minutes<\/li>\n<li>Typical stabilization time of 8 minutes<\/li>\n<li>MVI technology for improved resistance to mains voltage fluctuations<\/li>\n<li>Interchangeable calibration inserts<\/li>\n<li>Calibration well diameter of 26 mm<\/li>\n<li>Immersion depth of 115 mm<\/li>\n<li>Automatic temperature stepping<\/li>\n<li>Automatic temperature switch testing<\/li>\n<li>Intuitive user interface<\/li>\n<li>Color display with temperature status indication<\/li>\n<li>USB communication interface<\/li>\n<li>Compatible with JofraCal calibration software<\/li>\n<li>DNV type approval for maritime applications<\/li>\n<li>Compact and robust construction<\/li>\n<li>Weight of approximately 6.1 kg<\/li>\n<li>Suitable for laboratory and field calibration<\/li>\n<\/ul>\n<h2>Ideal for Maritime Temperature Calibration<\/h2>\n<p>The <strong>AMETEK MTC-650<\/strong> was specifically developed for temperature calibration aboard ships and offshore installations.<\/p>\n<p>Reliable temperature measurements are essential for the safe and efficient operation of marine engines, propulsion systems and auxiliary equipment.<\/p>\n<p>Temperature sensors are used throughout marine installations to monitor critical operating conditions.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Marine diesel engines<\/li>\n<li>Exhaust gas temperature monitoring<\/li>\n<li>Lubricating oil systems<\/li>\n<li>Cooling water systems<\/li>\n<li>Fuel oil systems<\/li>\n<li>Steam systems<\/li>\n<li>Hydraulic equipment<\/li>\n<li>Bearings<\/li>\n<li>Heat exchangers<\/li>\n<li>Auxiliary machinery<\/li>\n<li>Industrial heating systems<\/li>\n<\/ul>\n<p>Regular calibration helps maintain reliable temperature measurements and supports preventive maintenance.<\/p>\n<p>The AMETEK MTC-650 allows technicians to perform temperature calibration directly at the installation site.<\/p>\n<p>This reduces the need to transport temperature sensors to an external calibration laboratory.<\/p>\n<h2>Temperature Range from 28 \u00b0C to 650 \u00b0C<\/h2>\n<p>The AMETEK MTC-650 provides a temperature calibration range of:<\/p>\n<p><strong>28 \u00b0C to 650 \u00b0C<\/strong><\/p>\n<p>The minimum achievable temperature depends on the ambient temperature.<\/p>\n<p>At an ambient temperature of 23 \u00b0C, the minimum calibration temperature is approximately 28 \u00b0C.<\/p>\n<p>The manufacturer specifies a minimum calibration temperature approximately 5 \u00b0C above ambient temperature.<\/p>\n<p>Typical calibration points include:<\/p>\n<ul>\n<li>50 \u00b0C<\/li>\n<li>100 \u00b0C<\/li>\n<li>150 \u00b0C<\/li>\n<li>200 \u00b0C<\/li>\n<li>250 \u00b0C<\/li>\n<li>300 \u00b0C<\/li>\n<li>400 \u00b0C<\/li>\n<li>500 \u00b0C<\/li>\n<li>600 \u00b0C<\/li>\n<li>650 \u00b0C<\/li>\n<\/ul>\n<p>This wide temperature range makes the AMETEK MTC-650 suitable for numerous industrial and maritime temperature measurement applications.<\/p>\n<p>The instrument is particularly useful for calibrating sensors operating at elevated temperatures.<\/p>\n<h2>Temperature Accuracy<\/h2>\n<p>The AMETEK MTC-650 provides reliable temperature accuracy over its operating range.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>One year accuracy: \u00b10.9 \u00b0C<\/strong><\/p>\n<p><strong>Three year accuracy: \u00b11.8 \u00b0C<\/strong><\/p>\n<p>These specifications describe the performance of the internal temperature reference under the manufacturer&#8217;s defined conditions.<\/p>\n<p>The three year accuracy specification supports applications where longer calibration intervals are appropriate.<\/p>\n<p>The calibration interval should always be selected according to the application, required measurement uncertainty, historical calibration results and applicable quality requirements.<\/p>\n<p>The manufacturer&#8217;s accuracy specification must not be confused with the expanded measurement uncertainty stated on an individual calibration certificate.<\/p>\n<h2>Excellent Temperature Stability<\/h2>\n<p>The AMETEK MTC-650 provides temperature stability of:<\/p>\n<p><strong>\u00b10.1 \u00b0C<\/strong><\/p>\n<p>Temperature stability describes the variation of the calibration block temperature over time under defined operating conditions.<\/p>\n<p>The manufacturer evaluates stability after the stability indicator has been active for 10 minutes.<\/p>\n<p>The measurement period is 30 minutes.<\/p>\n<p>Stable temperature conditions are essential for reliable temperature sensor calibration.<\/p>\n<p>The AMETEK MTC-650 provides a controlled temperature environment for routine calibration and verification procedures.<\/p>\n<h2>MVI Technology for Stable Temperature Control<\/h2>\n<p>The AMETEK MTC-650 features MVI technology.<\/p>\n<p>MVI stands for <strong>Mains power Variance Immunity<\/strong>.<\/p>\n<p>This technology helps maintain stable temperature control when the mains supply voltage fluctuates.<\/p>\n<p>Voltage fluctuations can affect the heating performance of conventional temperature calibrators.<\/p>\n<p>MVI technology continuously monitors the power supply and helps maintain consistent energy delivery to the heating elements.<\/p>\n<p>This is particularly useful aboard ships, where electrical supply conditions may vary.<\/p>\n<p>The technology improves the reliability of temperature calibration under demanding operating conditions.<\/p>\n<h2>Fast Heating Performance<\/h2>\n<p>The AMETEK MTC-650 features an efficient heating system.<\/p>\n<p>The manufacturer specifies a typical heating time of:<\/p>\n<p><strong>18 minutes from 23 \u00b0C to 650 \u00b0C<\/strong><\/p>\n<p>This allows the calibrator to reach its maximum temperature quickly.<\/p>\n<p>Fast heating is particularly useful when performing multi-point calibration procedures.<\/p>\n<p>Short heating times reduce waiting periods and improve calibration efficiency.<\/p>\n<p>Actual heating performance depends on ambient conditions, sensor loading and the selected calibration insert.<\/p>\n<h2>Efficient Cooling Performance<\/h2>\n<p>The AMETEK MTC-650 also provides efficient cooling performance.<\/p>\n<p>Typical cooling times include:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature Change<\/th>\n<th>Cooling Time<\/th>\n<\/tr>\n<tr>\n<td>650 \u00b0C to 100 \u00b0C<\/td>\n<td>39 minutes<\/td>\n<\/tr>\n<tr>\n<td>100 \u00b0C to 50 \u00b0C<\/td>\n<td>18 minutes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These cooling times allow technicians to perform calibration procedures with increasing and decreasing temperature sequences.<\/p>\n<p>This is particularly useful when investigating temperature sensor hysteresis.<\/p>\n<p>The actual cooling time depends on operating conditions and the thermal loading of the calibration block.<\/p>\n<h2>Short Stabilization Time<\/h2>\n<p>The AMETEK MTC-650 features a typical stabilization time of:<\/p>\n<p><strong>8 minutes<\/strong><\/p>\n<p>This describes the time required for the calibration block to stabilize under specified conditions.<\/p>\n<p>The stabilization time of the device under test must also be considered.<\/p>\n<p>Large temperature sensors or sensors with slow thermal response may require additional time before reliable measurements can be recorded.<\/p>\n<p>For demanding calibration procedures, sufficient thermal equilibrium should be verified before recording the measurement results.<\/p>\n<h2>Excellent Radial Temperature Homogeneity<\/h2>\n<p>The AMETEK MTC-650 provides radial temperature homogeneity of:<\/p>\n<p><strong>0.1 \u00b0C<\/strong><\/p>\n<p>This specification describes temperature differences between calibration holes under defined conditions.<\/p>\n<p>Good radial temperature homogeneity is particularly important when calibrating several temperature sensors simultaneously.<\/p>\n<p>It helps minimize temperature differences between the reference thermometer and the devices under test.<\/p>\n<p>The actual calibration uncertainty also depends on sensor geometry, immersion depth and thermal contact.<\/p>\n<h2>Interchangeable Calibration Inserts<\/h2>\n<p>The AMETEK MTC-650 uses interchangeable calibration inserts.<\/p>\n<p>These allow temperature sensors with different diameters to be accommodated within the calibration block.<\/p>\n<p>The manufacturer specifies:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Value<\/th>\n<\/tr>\n<tr>\n<td>Calibration well diameter<\/td>\n<td>26 mm<\/td>\n<\/tr>\n<tr>\n<td>Insert outer diameter<\/td>\n<td>25.7 mm<\/td>\n<\/tr>\n<tr>\n<td>Insert length<\/td>\n<td>120 mm<\/td>\n<\/tr>\n<tr>\n<td>Immersion depth<\/td>\n<td>115 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Different insert configurations are available.<\/p>\n<p>The appropriate insert should be selected according to the dimensions of the temperature sensor.<\/p>\n<p>Good thermal contact between the sensor and insert helps reduce measurement errors.<\/p>\n<p>Excessive clearance can increase temperature differences between the calibration block and the sensing element.<\/p>\n<h2>Automatic Temperature Stepping<\/h2>\n<p>The AMETEK MTC-650 supports automatic temperature stepping.<\/p>\n<p>Users can define temperature setpoints and holding times.<\/p>\n<p>The calibrator then performs the programmed temperature sequence automatically.<\/p>\n<p>This function is particularly useful for repetitive calibration procedures.<\/p>\n<p>Automatic stepping reduces manual intervention and improves calibration efficiency.<\/p>\n<p>For maritime applications, technicians can prepare a calibration sequence and allow the instrument to complete the programmed temperature changes.<\/p>\n<h2>Automatic Temperature Switch Testing<\/h2>\n<p>The AMETEK MTC-650 supports automatic temperature switch testing.<\/p>\n<p>Temperature switches are widely used in marine engines and industrial control systems.<\/p>\n<p>They activate or deactivate electrical contacts when a defined temperature is reached.<\/p>\n<p>The AMETEK MTC-650 can generate controlled temperature changes while monitoring the switch contact.<\/p>\n<p>This allows switching points and hysteresis to be determined.<\/p>\n<p>The function is particularly useful for preventive maintenance and verification of temperature protection systems.<\/p>\n<h2>Intuitive User Interface<\/h2>\n<p>The AMETEK MTC-650 features an intuitive user interface.<\/p>\n<p>The instrument uses a convenient operating concept with dedicated function keys.<\/p>\n<p>Important calibration functions can be accessed directly.<\/p>\n<p>The display provides information about:<\/p>\n<ul>\n<li>Set temperature<\/li>\n<li>Actual temperature<\/li>\n<li>Temperature stability<\/li>\n<li>Heating and cooling status<\/li>\n<li>Calibration progress<\/li>\n<li>Instrument operating status<\/li>\n<\/ul>\n<p>The interface is designed for convenient operation in industrial and maritime environments.<\/p>\n<h2>USB Communication and Calibration Software<\/h2>\n<p>The AMETEK MTC-650 includes a USB 2.0 communication interface.<\/p>\n<p>This interface allows communication with compatible calibration software.<\/p>\n<p>The instrument supports JofraCal calibration software.<\/p>\n<p>The software can assist with calibration procedures and documentation.<\/p>\n<p>Computer-assisted calibration helps improve consistency and reduces repetitive manual operations.<\/p>\n<p>The available functions depend on the software version and the connected equipment.<\/p>\n<h2>DNV Type Approval<\/h2>\n<p>The AMETEK MTC-650 has DNV type approval for maritime applications.<\/p>\n<p>DNV is an internationally recognized classification society.<\/p>\n<p>The type approval confirms that the instrument has been assessed according to the applicable requirements stated in the approval certificate.<\/p>\n<p>This makes the AMETEK MTC-650 particularly suitable for use aboard ships and offshore installations.<\/p>\n<p>The approval is an important advantage for maritime operators requiring suitable calibration equipment for onboard maintenance.<\/p>\n<h2>Extended Calibration Intervals<\/h2>\n<p>The AMETEK MTC-650 offers specifications for one year and three year calibration intervals.<\/p>\n<p>The manufacturer specifies:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Calibration Interval<\/th>\n<th>Temperature Accuracy<\/th>\n<\/tr>\n<tr>\n<td>1 year<\/td>\n<td>\u00b10.9 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>3 years<\/td>\n<td>\u00b11.8 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A longer calibration interval can reduce the frequency of equipment transportation and recalibration.<\/p>\n<p>This is particularly useful for ships operating internationally.<\/p>\n<p>However, the appropriate calibration interval must be determined according to the measurement requirements and quality management procedures.<\/p>\n<p>A three year manufacturer specification does not automatically establish a suitable three year interval for every application.<\/p>\n<h2>Compact and Portable Construction<\/h2>\n<p>The AMETEK MTC-650 is designed for mobile temperature calibration.<\/p>\n<p>The instrument weighs approximately:<\/p>\n<p><strong>6.1 kg<\/strong><\/p>\n<p>Its dimensions are:<\/p>\n<p><strong>248 \u00d7 148 \u00d7 305 mm<\/strong><\/p>\n<p>The compact construction makes it suitable for transportation between different measurement locations.<\/p>\n<p>A protective carrying case is available.<\/p>\n<p>The carrying case provides storage space for the calibrator, calibration inserts, accessories and documentation.<\/p>\n<p>This is particularly useful for maritime maintenance technicians who need to transport calibration equipment between different areas of a ship.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>AMETEK MTC-650<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>AMETEK<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>MTC-650<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Marine Temperature Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>28 \u00b0C to 650 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Minimum temperature<\/td>\n<td>Ambient temperature +5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>One year accuracy<\/td>\n<td>\u00b10.9 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Three year accuracy<\/td>\n<td>\u00b11.8 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial homogeneity<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>1 \u00b0C or 0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Heating time, 23 \u00b0C to 650 \u00b0C<\/td>\n<td>18 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, 650 \u00b0C to 100 \u00b0C<\/td>\n<td>39 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, 100 \u00b0C to 50 \u00b0C<\/td>\n<td>18 minutes<\/td>\n<\/tr>\n<tr>\n<td>Typical stabilization time<\/td>\n<td>8 minutes<\/td>\n<\/tr>\n<tr>\n<td>Calibration well diameter<\/td>\n<td>26 mm<\/td>\n<\/tr>\n<tr>\n<td>Immersion depth<\/td>\n<td>115 mm<\/td>\n<\/tr>\n<tr>\n<td>Insert outer diameter<\/td>\n<td>25.7 mm<\/td>\n<\/tr>\n<tr>\n<td>Insert length<\/td>\n<td>120 mm<\/td>\n<\/tr>\n<tr>\n<td>Temperature control<\/td>\n<td>MVI technology<\/td>\n<\/tr>\n<tr>\n<td>Automatic temperature stepping<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Automatic switch testing<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Communication interface<\/td>\n<td>USB 2.0<\/td>\n<\/tr>\n<tr>\n<td>Calibration software<\/td>\n<td>JofraCal<\/td>\n<\/tr>\n<tr>\n<td>DNV type approval<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>0 \u00b0C to 50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>\u221220 \u00b0C to 50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Relative humidity<\/td>\n<td>5% to 90% RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>115 V or 230 V AC<\/td>\n<\/tr>\n<tr>\n<td>Maximum power consumption<\/td>\n<td>1150 VA<\/td>\n<\/tr>\n<tr>\n<td>Protection rating<\/td>\n<td>IP10<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>248 \u00d7 148 \u00d7 305 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 6.1 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Calibration of Pt100 and RTD Sensors<\/h2>\n<p>The AMETEK MTC-650 is suitable for calibrating resistance temperature detectors.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Pt100 calibration<\/li>\n<li>Pt1000 calibration<\/li>\n<li>Industrial RTD calibration<\/li>\n<li>Temperature probe verification<\/li>\n<li>Temperature indicator testing<\/li>\n<\/ul>\n<p>The sensor is inserted into a suitable calibration insert.<\/p>\n<p>The calibration block generates a controlled temperature.<\/p>\n<p>The temperature indicated by the device under test can then be compared with the reference temperature.<\/p>\n<p>For demanding applications, a suitable external reference thermometer can be used.<\/p>\n<p>The AMETEK MTC-650 provides the temperature source. Electrical resistance measurement requires a suitable external instrument.<\/p>\n<h2>Calibration of Thermocouples<\/h2>\n<p>The AMETEK MTC-650 can also be used for thermocouple calibration.<\/p>\n<p>Thermocouples are widely used in marine engines and industrial applications requiring elevated temperatures.<\/p>\n<p>Typical applications include exhaust gas temperature monitoring and industrial heating systems.<\/p>\n<p>The thermocouple is inserted into the calibration block and allowed to stabilize.<\/p>\n<p>Its indicated temperature can then be compared with the reference temperature.<\/p>\n<p>For accurate thermocouple calibration, reference junction compensation and the measurement uncertainty of the readout must be considered.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and calibration equipment.<\/p>\n<p>When the AMETEK MTC-650 is used for temperature sensor calibration, the measurement uncertainty must be evaluated according to the complete calibration procedure.<\/p>\n<p>Relevant uncertainty contributions include:<\/p>\n<ul>\n<li>Calibration of the temperature reference<\/li>\n<li>Temperature stability<\/li>\n<li>Axial temperature distribution<\/li>\n<li>Radial temperature distribution<\/li>\n<li>Sensor immersion depth<\/li>\n<li>Thermal contact between sensor and insert<\/li>\n<li>Loading effects<\/li>\n<li>Reference thermometer uncertainty<\/li>\n<li>Measurement repeatability<\/li>\n<\/ul>\n<p>The uncertainty evaluation should follow the applicable calibration procedure and relevant metrological guidelines.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the AMETEK MTC-650?<\/h2>\n<p>The AMETEK MTC-650 combines reliable temperature calibration with robust construction and convenient operation.<\/p>\n<p>Its temperature range from 28 \u00b0C to 650 \u00b0C covers numerous industrial and maritime applications.<\/p>\n<p>Fast heating allows the instrument to reach 650 \u00b0C in approximately 18 minutes.<\/p>\n<p>Temperature stability of \u00b10.1 \u00b0C provides reliable conditions for routine calibration procedures.<\/p>\n<p>MVI technology helps maintain stable operation when mains voltage fluctuations occur.<\/p>\n<p>The instrument&#8217;s DNV type approval makes it particularly suitable for maritime applications.<\/p>\n<p>Automatic temperature stepping and temperature switch testing simplify routine calibration tasks.<\/p>\n<p>The compact design and weight of approximately 6.1 kg make the calibrator suitable for mobile use.<\/p>\n<p>For marine engineers, maintenance technicians and industrial users requiring a reliable temperature calibrator, the AMETEK MTC-650 provides an excellent combination of performance, portability and convenience.<\/p>\n<p>europascal supports customers with professional calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the AMETEK MTC-650<\/h2>\n<p>The AMETEK MTC-650 is suitable for numerous professional temperature calibration applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Marine temperature calibration<\/li>\n<li>Pt100 calibration<\/li>\n<li>Pt1000 calibration<\/li>\n<li>RTD calibration<\/li>\n<li>Thermocouple calibration<\/li>\n<li>Temperature switch testing<\/li>\n<li>Marine diesel engines<\/li>\n<li>Exhaust gas temperature monitoring<\/li>\n<li>Lubricating oil systems<\/li>\n<li>Cooling water systems<\/li>\n<li>Fuel oil systems<\/li>\n<li>Steam systems<\/li>\n<li>Hydraulic systems<\/li>\n<li>Offshore installations<\/li>\n<li>Ship maintenance<\/li>\n<li>Industrial process instrumentation<\/li>\n<li>Preventive maintenance<\/li>\n<li>Calibration laboratories<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Temperature metrology<\/li>\n<li>Field calibration<\/li>\n<\/ul>\n<p>The combination of fast heating, reliable temperature stability, MVI technology and DNV type approval makes the AMETEK MTC-650 a professional solution for demanding maritime and industrial temperature calibration applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/en\/\">Find more temperature calibration equipment at europascal.<\/a><\/p>\n<p>Manufacturer information for the AMETEK MTC-650 can be found on the <a href=\"https:\/\/www.ametekcalibration.com\/\" target=\"_blank\" rel=\"noopener\">official AMETEK website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Ametek-MTC-650A-Marine-Temperature-Calibrator.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>AMETEK MTC-650<\/strong> is a robust marine dry block temperature calibrator with a range from <strong>28 \u00b0C to 650 \u00b0C<\/strong>. Featuring fast heating in just <strong>18 minutes<\/strong>, temperature stability of <strong>\u00b10.1 \u00b0C<\/strong> and DNV type approval, it provides reliable performance for maritime and industrial temperature calibration. Ideal for calibrating RTDs, thermocouples and temperature switches aboard ships, offshore installations and industrial facilities.<\/p>\n","protected":false},"featured_media":3439,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[92],"product_cat":[1206,53],"product_tag":[4781,6392,6393,5858,6394,3920,5025,6395,6396,5832,4395,6397,6398,6399,6400,5027,3999,6401,4000,4001,5850,4085,5851,4076,6402,6403,4005,6404],"class_list":["post-6949","product","type-product","status-publish","has-post-thumbnail","product_brand-ametek","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-ametek-calibration","product_tag-ametek-jofra-mtc-650","product_tag-ametek-mtc-650","product_tag-auto-step","product_tag-auto-stepping","product_tag-europascal","product_tag-jofra","product_tag-jofra-mtc-650","product_tag-jofra-mtc-650a","product_tag-jofracal","product_tag-kalibriertechnik","product_tag-mtc-650","product_tag-mtc-650-a-mkii","product_tag-mtc-650-temperaturkalibrator","product_tag-mvi","product_tag-pt100-kalibrierung","product_tag-temperaturkalibrator","product_tag-temperaturkalibrator-650-c","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-temperaturschalter","product_tag-temperatursensor-kalibrieren","product_tag-temperaturtransmitter","product_tag-thermoelement-kalibrierung","product_tag-trockenblock-650-c","product_tag-trockenblock-temperaturkalibrator","product_tag-trockenblockkalibrator","product_tag-trockenblockkalibrator-650-c","pa_bauart-tisch","pa_funktion-nur-heizen","pa_genauigkeit-2-0-c","pa_messbereich-1200c","pa_schnittstelle-usb","pa_stabilitaet-0-1-c","pa_strom-versorgung-230v","pa_temperaturbereich-100c-bis-1205c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6949","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3439"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6949"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6949"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6949"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6949"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}