{"id":6954,"date":"2026-07-17T16:50:13","date_gmt":"2026-07-17T16:50:13","guid":{"rendered":"https:\/\/europascal.de\/product\/europascal-ep-mb-165\/"},"modified":"2026-10-14T09:12:49","modified_gmt":"2026-10-14T09:12:49","slug":"europascal-ep-mb-165","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/europascal-ep-mb-165\/","title":{"rendered":"europascal EP-MB-165 Versatile Temperature Calibrator"},"content":{"rendered":"<p>The <strong>europascal EP-MB-165<\/strong> is a versatile multifunction temperature calibrator combining the advantages of a liquid calibration bath and a dry block calibrator in one compact instrument.<\/p>\n<p>With a temperature range from <strong>\u221235 \u00b0C to +165 \u00b0C<\/strong>, temperature stability of <strong>\u00b10.01 \u00b0C<\/strong> and accuracy of <strong>0.1 \u00b0C<\/strong>, the europascal EP-MB-165 provides reliable performance for professional temperature sensor calibration.<\/p>\n<p>Its innovative multifunction design allows users to switch between liquid bath and dry block calibration using interchangeable inserts and accessories.<\/p>\n<p>The instrument is particularly suitable for calibrating resistance temperature detectors (RTDs), Pt100 sensors, thermocouples, industrial temperature probes and other temperature measuring instruments.<\/p>\n<p>The europascal EP-MB-165 combines high temperature stability, excellent temperature uniformity and flexible operation, making it suitable for calibration laboratories, industrial maintenance, pharmaceutical manufacturing, food processing and research facilities.<\/p>\n<p>With a calibration volume of <strong>60 mm diameter and 190 mm depth<\/strong>, the instrument accommodates various temperature sensor designs.<\/p>\n<p>Its portable construction, intuitive operation and optional RS485 Modbus RTU communication interface make it a practical solution for laboratory and industrial calibration applications.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/?utm_source=chatgpt.com\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Temperature range from \u221235 \u00b0C to +165 \u00b0C<\/li>\n<li>Combined liquid bath and dry block functionality<\/li>\n<li>Temperature accuracy of 0.1 \u00b0C<\/li>\n<li>Excellent temperature stability of \u00b10.01 \u00b0C<\/li>\n<li>Liquid bath temperature uniformity of \u00b10.03 \u00b0C<\/li>\n<li>Dry block temperature uniformity of \u00b10.05 \u00b0C<\/li>\n<li>Calibration volume of 60 \u00d7 190 mm<\/li>\n<li>Liquid bath capacity of 0.7 liters<\/li>\n<li>Fast heating and cooling performance<\/li>\n<li>Heating from \u22125 \u00b0C to +100 \u00b0C in approximately 15 minutes<\/li>\n<li>Cooling from +25 \u00b0C to \u221225 \u00b0C in approximately 20 minutes<\/li>\n<li>Interchangeable calibration inserts<\/li>\n<li>Optional infrared calibration insert<\/li>\n<li>Optional surface temperature calibration insert<\/li>\n<li>Adjustable stirring speed<\/li>\n<li>Integrated internal reference temperature sensor<\/li>\n<li>Double display with 0.1 \u00b0C resolution<\/li>\n<li>Menu adjustment using 10 calibration points<\/li>\n<li>Optional RS485 Modbus RTU communication<\/li>\n<li>Compact and portable construction<\/li>\n<li>Weight of approximately 12.8 kg<\/li>\n<li>Three-year manufacturer&#8217;s warranty<\/li>\n<\/ul>\n<h2>Wide Temperature Range from \u221235 \u00b0C to +165 \u00b0C<\/h2>\n<p>The <strong>europascal EP-MB-165<\/strong> provides a temperature calibration range from <strong>\u221235 \u00b0C to +165 \u00b0C<\/strong>.<\/p>\n<p>This wide operating range covers numerous industrial and laboratory applications requiring temperature calibration below and above ambient temperature.<\/p>\n<p>Typical calibration temperatures include \u221230 \u00b0C, \u221220 \u00b0C, 0 \u00b0C, 25 \u00b0C, 50 \u00b0C, 100 \u00b0C, 150 \u00b0C and 165 \u00b0C.<\/p>\n<p>The minimum achievable temperature depends on the ambient temperature.<\/p>\n<p>According to the manufacturer&#8217;s specification, the instrument can reach temperatures approximately 55 \u00b0C below ambient temperature, with an absolute minimum of \u221235 \u00b0C.<\/p>\n<p>This makes the europascal EP-MB-165 particularly suitable for calibrating temperature sensors used in refrigeration systems, environmental monitoring, pharmaceutical manufacturing and industrial temperature measurement.<\/p>\n<h2>Multifunction Liquid Bath and Dry Block Calibrator<\/h2>\n<p>One of the most important advantages of the europascal EP-MB-165 is its multifunction design.<\/p>\n<p>The instrument combines two temperature calibration methods in a single device.<\/p>\n<h3>Liquid Bath Calibration<\/h3>\n<p>In liquid bath mode, the instrument uses a temperature-controlled calibration liquid to provide excellent thermal contact with inserted temperature sensors.<\/p>\n<p>This method is particularly suitable for calibrating sensors with different diameters, shapes and sensing element positions.<\/p>\n<p>The liquid bath provides excellent temperature uniformity and stable measurement conditions.<\/p>\n<h3>Dry Block Calibration<\/h3>\n<p>In dry block mode, interchangeable metal inserts provide controlled temperature conditions without requiring a calibration liquid.<\/p>\n<p>This method is particularly suitable for routine calibration, field service and industrial maintenance.<\/p>\n<p>The dry block configuration simplifies handling and reduces preparation and cleaning requirements.<\/p>\n<p>The ability to switch between both methods makes the europascal EP-MB-165 a flexible solution for demanding calibration applications.<\/p>\n<h2>Excellent Temperature Stability of \u00b10.01 \u00b0C<\/h2>\n<p>The europascal EP-MB-165 provides excellent temperature stability in both operating modes.<\/p>\n<p>The specified temperature stability is:<\/p>\n<p><strong>\u00b10.01 \u00b0C<\/strong><\/p>\n<p>This applies to both liquid bath and dry block operation.<\/p>\n<p>Temperature stability describes the variation of the calibration temperature over time under defined operating conditions.<\/p>\n<p>High temperature stability is essential for accurate comparison calibrations.<\/p>\n<p>It helps minimize measurement variations and supports reliable calibration results.<\/p>\n<p>For demanding calibration applications, the stability contribution must be considered when evaluating the measurement uncertainty.<\/p>\n<h2>High Temperature Accuracy<\/h2>\n<p>The europascal EP-MB-165 provides a specified temperature accuracy of:<\/p>\n<p><strong>0.1 \u00b0C<\/strong><\/p>\n<p>The instrument uses an internal reference temperature sensor to control and monitor the calibration temperature.<\/p>\n<p>This allows accurate temperature generation across the specified operating range.<\/p>\n<p>For applications requiring particularly low measurement uncertainty, a calibrated external reference thermometer can be used.<\/p>\n<p>The external reference thermometer measures the actual temperature within the calibration bath or dry block insert.<\/p>\n<p>This enables direct comparison between the reference thermometer and the device under test.<\/p>\n<p>The measurement uncertainty of the complete calibration system must be evaluated according to the applicable calibration procedure.<\/p>\n<h2>Excellent Temperature Uniformity<\/h2>\n<p>The europascal EP-MB-165 provides excellent temperature uniformity.<\/p>\n<p>The specified values depend on the selected operating mode.<\/p>\n<div>\n<div>\n<div>\n<table>\n<thead>\n<tr>\n<th>Operating Mode<\/th>\n<th>Temperature Uniformity<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Liquid Bath<\/td>\n<td>\u00b10.03 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dry Block<\/td>\n<td>\u00b10.05 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>Excellent temperature uniformity is particularly important when calibrating multiple temperature sensors simultaneously.<\/p>\n<p>Good temperature distribution helps reduce differences between the reference thermometer and the devices under test.<\/p>\n<p>The actual temperature distribution also depends on sensor dimensions, immersion depth, thermal loading and operating conditions.<\/p>\n<h2>Liquid Bath with 0.7 Liter Capacity<\/h2>\n<p>The europascal EP-MB-165 features a liquid bath capacity of:<\/p>\n<p><strong>0.7 liters<\/strong><\/p>\n<p>The calibration volume has a diameter of 60 mm and a depth of 190 mm.<\/p>\n<p>This provides sufficient space for calibrating various industrial temperature sensors.<\/p>\n<p>The manufacturer recommends silicone oil with a viscosity of approximately 10 cSt for liquid bath operation.<\/p>\n<p>The selected calibration liquid must be suitable for the intended temperature range and operating conditions.<\/p>\n<p>The liquid bath configuration is particularly useful for temperature sensors that cannot be accommodated easily in conventional dry block inserts.<\/p>\n<h2>Interchangeable Calibration Inserts<\/h2>\n<p>The europascal EP-MB-165 supports interchangeable calibration inserts.<\/p>\n<p>The dry block inserts have the following dimensions:<\/p>\n<div>\n<div>\n<div>\n<table>\n<thead>\n<tr>\n<th>Specification<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Insert diameter<\/td>\n<td>59.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Insert length<\/td>\n<td>165 mm<\/td>\n<\/tr>\n<tr>\n<td>Calibration volume<\/td>\n<td>\u00d8 60 \u00d7 190 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>Different insert configurations are available for temperature sensors with various diameters.<\/p>\n<p>Available bore diameters include 3.5 mm, 4.5 mm, 5.0 mm, 5.5 mm, 6.5 mm, 8.5 mm, 9.0 mm, 9.5 mm and 10.5 mm.<\/p>\n<p>Depending on the selected insert, several temperature sensors can be calibrated simultaneously.<\/p>\n<p>The appropriate insert should be selected according to the dimensions of the temperature sensors.<\/p>\n<p>Good thermal contact between the sensor and insert helps minimize measurement errors.<\/p>\n<h2>Fast Heating Performance<\/h2>\n<p>The europascal EP-MB-165 provides efficient heating performance.<\/p>\n<p>The manufacturer specifies a typical heating time of:<\/p>\n<p><strong>15 minutes from \u22125 \u00b0C to +100 \u00b0C<\/strong><\/p>\n<p>Fast heating reduces waiting times between calibration points.<\/p>\n<p>This is particularly useful when performing multi-point temperature calibration procedures.<\/p>\n<p>Actual heating times depend on ambient conditions, sensor loading and the selected operating mode.<\/p>\n<h2>Fast Cooling Performance<\/h2>\n<p>The europascal EP-MB-165 also provides efficient cooling performance.<\/p>\n<p>The manufacturer specifies a typical cooling time of:<\/p>\n<p><strong>20 minutes from +25 \u00b0C to \u221225 \u00b0C<\/strong><\/p>\n<p>This allows temperature sensors to be calibrated below ambient temperature without requiring a separate cooling bath.<\/p>\n<p>The cooling capability is particularly useful for refrigeration, environmental monitoring and industrial temperature measurement applications.<\/p>\n<h2>Optional Infrared Calibration Insert<\/h2>\n<p>The europascal EP-MB-165 can be equipped with an optional infrared calibration insert.<\/p>\n<p>This accessory allows the instrument to be used for infrared temperature calibration applications.<\/p>\n<p>The specified operating temperature range of the blackbody insert is:<\/p>\n<p><strong>\u221220 \u00b0C to +150 \u00b0C<\/strong><\/p>\n<p>The infrared calibration insert is available with an external reference temperature sensor.<\/p>\n<p>This configuration provides additional flexibility for users who need to calibrate contact and non-contact temperature measuring instruments.<\/p>\n<p>The suitability of the insert for a particular infrared thermometer depends on the instrument&#8217;s measurement geometry, spectral characteristics and required measurement uncertainty.<\/p>\n<h2>Optional Surface Temperature Calibration Insert<\/h2>\n<p>An optional surface temperature calibration insert is also available.<\/p>\n<p>This accessory is designed for calibrating suitable surface temperature sensors.<\/p>\n<p>The specified operating temperature range is:<\/p>\n<p><strong>\u221225 \u00b0C to +150 \u00b0C<\/strong><\/p>\n<p>Surface temperature calibration requires particular attention to thermal contact and heat transfer between the sensor and calibration surface.<\/p>\n<p>The optional surface insert extends the application range of the europascal EP-MB-165 beyond conventional immersion temperature calibration.<\/p>\n<h2>Optional RS485 Modbus RTU Communication<\/h2>\n<p>The europascal EP-MB-165 can be equipped with an optional RS485 communication interface.<\/p>\n<p>The interface supports the Modbus RTU protocol.<\/p>\n<p>Communication is provided through a DB9 connector.<\/p>\n<p>This allows the calibrator to be integrated into compatible computer-assisted calibration systems.<\/p>\n<p>The optional communication package includes software, while the PC connection cable is not included according to the supplied datasheet.<\/p>\n<p>The available communication functions depend on the installed interface and software configuration.<\/p>\n<h2>Intuitive Operation<\/h2>\n<p>The europascal EP-MB-165 features a user-friendly control system.<\/p>\n<p>The instrument includes a double display with a resolution of:<\/p>\n<p><strong>0.1 \u00b0C<\/strong><\/p>\n<p>The operating menu allows adjustment using ten calibration points.<\/p>\n<p>This supports convenient operation and temperature control.<\/p>\n<p>In liquid bath mode, the stirring speed can be adjusted using a potentiometer.<\/p>\n<p>The integrated stirring system helps maintain uniform temperature conditions within the calibration liquid.<\/p>\n<h2>Portable Construction<\/h2>\n<p>The europascal EP-MB-165 combines professional calibration performance with portable construction.<\/p>\n<p>The instrument has the following dimensions:<\/p>\n<p><strong>250 \u00d7 370 \u00d7 400 mm<\/strong><\/p>\n<p>Its weight is approximately:<\/p>\n<p><strong>12.8 kg<\/strong><\/p>\n<p>The compact design makes the calibrator suitable for laboratory workbenches and industrial calibration environments.<\/p>\n<p>An optional transport case with wheels and a handle is available.<\/p>\n<p>This provides additional protection during transportation.<\/p>\n<h2>Technical Highlights<\/h2>\n<div>\n<div>\n<div>\n<table>\n<thead>\n<tr>\n<th>Specification<\/th>\n<th>europascal EP-MB-165<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Manufacturer<\/td>\n<td>europascal<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>EP-MB-165<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Multifunction Temperature Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Operating modes<\/td>\n<td>Liquid Bath \/ Dry Block<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u221235 \u00b0C to +165 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Minimum temperature<\/td>\n<td>55 \u00b0C below ambient, minimum \u221235 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature accuracy<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature stability<\/td>\n<td>\u00b10.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Liquid bath uniformity<\/td>\n<td>\u00b10.03 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dry block uniformity<\/td>\n<td>\u00b10.05 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Reference temperature sensor<\/td>\n<td>Internal<\/td>\n<\/tr>\n<tr>\n<td>Calibration volume<\/td>\n<td>\u00d8 60 \u00d7 190 mm<\/td>\n<\/tr>\n<tr>\n<td>Liquid bath capacity<\/td>\n<td>0.7 liters<\/td>\n<\/tr>\n<tr>\n<td>Dry block insert diameter<\/td>\n<td>59.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Dry block insert length<\/td>\n<td>165 mm<\/td>\n<\/tr>\n<tr>\n<td>Heating time, \u22125 \u00b0C to +100 \u00b0C<\/td>\n<td>15 minutes<\/td>\n<\/tr>\n<tr>\n<td>Cooling time, +25 \u00b0C to \u221225 \u00b0C<\/td>\n<td>20 minutes<\/td>\n<\/tr>\n<tr>\n<td>Calibration adjustment points<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Stirring speed<\/td>\n<td>Adjustable<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td>Optional RS485 Modbus RTU<\/td>\n<\/tr>\n<tr>\n<td>Infrared calibration insert<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Infrared insert temperature range<\/td>\n<td>\u221220 \u00b0C to +150 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Surface calibration insert<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Surface insert temperature range<\/td>\n<td>\u221225 \u00b0C to +150 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>100\u2013234 V AC, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>Approx. 310 W<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>250 \u00d7 370 \u00d7 400 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 12.8 kg<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer warranty<\/td>\n<td>3 years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h2>Calibration of RTDs and Pt100 Sensors<\/h2>\n<p>The europascal EP-MB-165 is suitable for calibrating resistance temperature detectors.<\/p>\n<p>Typical applications include Pt100, Pt1000 and industrial RTD calibration.<\/p>\n<p>The temperature sensor is inserted into the calibration bath or a suitable dry block insert.<\/p>\n<p>The calibrator generates a stable temperature that can be compared with the temperature indicated by the device under test.<\/p>\n<p>For demanding applications, an external reference thermometer can be used to improve the traceability and accuracy of the comparison measurement.<\/p>\n<h2>Calibration of Thermocouples<\/h2>\n<p>The europascal EP-MB-165 can also be used for thermocouple calibration.<\/p>\n<p>Thermocouples are widely used in industrial temperature measurement.<\/p>\n<p>The instrument provides stable temperature conditions for checking thermocouple measurement systems.<\/p>\n<p>The thermocouple is inserted into the calibration bath or dry block and allowed to stabilize.<\/p>\n<p>Its indicated temperature can then be compared with the reference temperature.<\/p>\n<p>For accurate thermocouple calibration, reference junction compensation and the measurement uncertainty of the readout must be considered.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and calibration equipment.<\/p>\n<p>When the europascal EP-MB-165 is used for temperature sensor calibration, the measurement uncertainty must be evaluated according to the complete calibration procedure.<\/p>\n<p>Relevant uncertainty contributions include temperature stability, temperature uniformity, reference thermometer calibration uncertainty, sensor immersion effects, thermal contact and measurement repeatability.<\/p>\n<p>The uncertainty evaluation should follow the applicable calibration procedure and relevant metrological guidelines.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/?utm_source=chatgpt.com\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the europascal EP-MB-165?<\/h2>\n<p>The europascal EP-MB-165 combines the advantages of a liquid calibration bath and a dry block calibrator in one compact instrument.<\/p>\n<p>Its temperature range from \u221235 \u00b0C to +165 \u00b0C covers numerous industrial and laboratory applications.<\/p>\n<p>Excellent temperature stability of \u00b10.01 \u00b0C and high temperature uniformity provide reliable conditions for precision temperature calibration.<\/p>\n<p>Interchangeable inserts allow different temperature sensors to be calibrated.<\/p>\n<p>Optional infrared and surface calibration inserts extend the application range of the instrument.<\/p>\n<p>Fast heating and cooling performance help reduce waiting times during calibration procedures.<\/p>\n<p>The optional RS485 Modbus RTU interface provides additional flexibility for computer-assisted calibration.<\/p>\n<p>For calibration laboratories, industrial maintenance departments, pharmaceutical manufacturers and research facilities, the europascal EP-MB-165 provides a flexible solution for professional temperature calibration.<\/p>\n<h2>Typical Applications for the europascal EP-MB-165<\/h2>\n<p>Typical applications include temperature sensor calibration, Pt100 calibration, Pt1000 calibration, RTD calibration, thermocouple calibration, liquid bath calibration, dry block calibration, pharmaceutical manufacturing, food processing, industrial quality assurance, research laboratories, universities, environmental monitoring and field calibration.<\/p>\n<p>The combination of multifunction operation, excellent temperature stability and flexible accessories makes the europascal EP-MB-165 a professional solution for demanding temperature calibration applications.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/europascal-Micro-Bath-EP-MB-165.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>europascal EP-MB-165<\/strong> is a versatile temperature calibrator combining a liquid bath and dry block in one portable instrument. With a temperature range from <strong>\u221235 \u00b0C to +165 \u00b0C<\/strong>, stability of <strong>\u00b10.01 \u00b0C<\/strong> and accuracy of <strong>0.1 \u00b0C<\/strong>, it provides reliable performance for professional temperature calibration.\u00a0Ideal for RTDs, thermocouples and industrial temperature sensors in laboratories and field applications.<\/p>\n","protected":false},"featured_media":3453,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4380],"product_cat":[55,1206,53],"product_tag":[6419,3920,6420,4125,6410,4105,3922,4395,6421,6411,6412,6413,3995,6414,6415,6358,3998,3999,4000,4001,4003,6416,4005,6417],"class_list":["post-6954","product","type-product","status-publish","has-post-thumbnail","product_brand-europascal-2","product_cat-liquid-bath-micro-bath","product_cat-dry-block-calibrators","product_cat-temperature","product_tag-ep-mb-165","product_tag-europascal","product_tag-europascal-ep-mb-165","product_tag-fluessigkeitsbad","product_tag-infrarot-kalibrierung","product_tag-kalibrierbad","product_tag-kalibrierlabor","product_tag-kalibriertechnik","product_tag-kuehlkalibrator","product_tag-mikro-bad","product_tag-multifunktions-temperaturkalibrator","product_tag-oberflaechentemperatur-kalibrierung","product_tag-pt100-kalibrieren","product_tag-referenztemperatur","product_tag-temperatur-mikrobad","product_tag-temperaturbad","product_tag-temperaturfuehler-kalibrieren","product_tag-temperaturkalibrator","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-thermoelement-kalibrieren","product_tag-trockenblock","product_tag-trockenblockkalibrator","product_tag-vergleichskalibrierung-temperatur","pa_bauart-tisch","pa_funktion-heizen-kuehlen","pa_genauigkeit-01-c","pa_medium-fluessigkeit","pa_messbereich-300c","pa_pc-version-ja","pa_schnittstelle-usb-a-isb-b-lan-wifi-ble","pa_stabilitaet-001c","pa_temperaturbereich-30-c-bis-250-c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3453"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6954"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6954"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}