{"id":6961,"date":"2026-07-17T16:57:15","date_gmt":"2026-07-17T16:57:15","guid":{"rendered":"https:\/\/europascal.de\/product\/europascal-ep-e168\/"},"modified":"2026-10-14T09:35:11","modified_gmt":"2026-10-14T09:35:11","slug":"europascal-ep-e168","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/europascal-ep-e168\/","title":{"rendered":"europascal EP-E168 Precise Reference Thermocouple"},"content":{"rendered":"<p>The <strong>europascal EP-E168<\/strong> is a high-precision industrial reference thermocouple designed for accurate temperature measurement and calibration applications. With a temperature range from <strong>0 \u00b0C to 1200 \u00b0C<\/strong>, this Type S thermocouple provides reliable performance in industrial calibration laboratories and demanding temperature measurement environments.<\/p>\n<p>The europascal EP-E168 features high-purity platinum and platinum-rhodium thermocouple wires, a gas-tight ceramic protection sheath and a design optimized for applications with limited immersion depths.<\/p>\n<p>Its compact construction makes the reference thermocouple particularly suitable for use in dry block temperature calibrators, where precise temperature measurement and excellent thermal response are essential.<\/p>\n<p>The thermocouple wires are thermally treated and annealed to minimize inhomogeneity and improve long-term measurement performance.<\/p>\n<p>For professional temperature calibration and metrological traceability, europascal also offers comprehensive services through the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The europascal EP-E168 combines high-quality thermocouple materials with a design specifically developed for industrial temperature calibration.<\/p>\n<p><strong>Key advantages include:<\/strong><\/p>\n<ul>\n<li>Wide temperature range from 0 \u00b0C to 1200 \u00b0C<\/li>\n<li>Industrial Type S reference thermocouple<\/li>\n<li>Platinum-rhodium\/platinum thermocouple wires<\/li>\n<li>High-purity thermoelectric materials<\/li>\n<li>Thermally treated and annealed thermocouple wires<\/li>\n<li>Reduced thermoelectric inhomogeneity<\/li>\n<li>Gas-tight high-purity ceramic protection sheath<\/li>\n<li>Optimized for small immersion depths<\/li>\n<li>Fast thermal response due to the thin ceramic sheath<\/li>\n<li>Suitable for dry block temperature calibrators<\/li>\n<li>Suitable for industrial reference measurements<\/li>\n<li>Individual calibration parameters<\/li>\n<li>Calibration according to DIN EN 60584<\/li>\n<li>Optional Type S miniature thermocouple connectors<\/li>\n<li>Optional carrying case<\/li>\n<li>DAkkS calibration available<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Temperature Range from 0 \u00b0C to 1200 \u00b0C<\/h2>\n<p>The <strong>europascal EP-E168<\/strong> provides a temperature measurement range of:<\/p>\n<p><strong>0 \u00b0C to 1200 \u00b0C<\/strong><\/p>\n<p>This wide temperature range makes the reference thermocouple suitable for numerous industrial and laboratory applications.<\/p>\n<p>Typical calibration temperatures include:<\/p>\n<ul>\n<li>0 \u00b0C<\/li>\n<li>100 \u00b0C<\/li>\n<li>200 \u00b0C<\/li>\n<li>300 \u00b0C<\/li>\n<li>400 \u00b0C<\/li>\n<li>500 \u00b0C<\/li>\n<li>600 \u00b0C<\/li>\n<li>800 \u00b0C<\/li>\n<li>1000 \u00b0C<\/li>\n<li>1200 \u00b0C<\/li>\n<\/ul>\n<p>The thermocouple is particularly suitable for applications requiring a stable reference sensor at elevated temperatures.<\/p>\n<p>Its noble metal construction provides the material characteristics required for demanding thermoelectric temperature measurements.<\/p>\n<h2>Type S Platinum-Rhodium Thermocouple<\/h2>\n<p>The europascal EP-E168 uses a Type S thermocouple measuring element.<\/p>\n<p>Type S thermocouples consist of two different thermoelectric materials:<\/p>\n<p><strong>Positive thermocouple wire:<\/strong> Platinum with 10% rhodium (Pt10Rh)<\/p>\n<p><strong>Negative thermocouple wire:<\/strong> Platinum (Pt)<\/p>\n<p>The thermoelectric voltage generated by these materials depends on the temperature difference between the measuring junction and the reference junction.<\/p>\n<p>The relationship between temperature and thermoelectric voltage is defined by the standardized Type S characteristic according to DIN EN 60584.<\/p>\n<p>Type S thermocouples are widely used as reference sensors in industrial temperature calibration.<\/p>\n<p>Their noble metal construction makes them particularly suitable for measurements at elevated temperatures.<\/p>\n<h2>High-Purity Thermocouple Materials<\/h2>\n<p>The europascal EP-E168 is manufactured using high-purity thermocouple wires.<\/p>\n<p>The manufacturer specifies the use of materials with the maximum available purity.<\/p>\n<p>High-purity thermocouple materials are important for achieving reliable thermoelectric characteristics.<\/p>\n<p>Impurities and changes in material composition can influence the thermoelectric voltage and introduce measurement errors.<\/p>\n<p>The use of carefully selected materials helps reduce these influences.<\/p>\n<p>This is particularly important when the thermocouple is used as a reference thermometer in calibration applications.<\/p>\n<h2>Thermally Treated and Annealed Thermocouple Wires<\/h2>\n<p>The thermocouple wires of the europascal EP-E168 are thermally treated and annealed.<\/p>\n<p>This manufacturing process helps reduce thermoelectric inhomogeneity.<\/p>\n<p>Inhomogeneity describes variations in the thermoelectric properties along the thermocouple wires.<\/p>\n<p>These variations can introduce measurement errors when different sections of the thermocouple are exposed to temperature gradients.<\/p>\n<p>Thermal treatment helps improve the consistency of the thermoelectric properties.<\/p>\n<p>This is particularly important for reference thermocouples used in calibration laboratories.<\/p>\n<p>The design of the europascal EP-E168 therefore supports reliable temperature measurements under demanding industrial conditions.<\/p>\n<h2>Optimized for Small Immersion Depths<\/h2>\n<p>One of the main advantages of the europascal EP-E168 is its design for applications with limited immersion depths.<\/p>\n<p>Conventional reference thermocouples may require relatively deep immersion to minimize heat conduction errors.<\/p>\n<p>However, many industrial dry block calibrators provide only limited calibration well depths.<\/p>\n<p>The europascal EP-E168 features a compact measuring assembly and a thin ceramic protection sheath.<\/p>\n<p>This makes it particularly suitable for temperature calibration applications where the available immersion depth is limited.<\/p>\n<p>The actual required immersion depth depends on the temperature, sensor construction and measurement uncertainty requirements.<\/p>\n<p>For high-accuracy applications, immersion effects must be evaluated as part of the calibration procedure.<\/p>\n<h2>Gas-Tight High-Purity Ceramic Protection Sheath<\/h2>\n<p>The europascal EP-E168 features a protection sheath manufactured from gas-tight high-purity ceramic.<\/p>\n<p>The ceramic sheath protects the thermocouple wires from the surrounding environment.<\/p>\n<p>Its high-purity construction helps reduce contamination of the noble metal thermocouple materials.<\/p>\n<p>Contamination can influence the thermoelectric properties of platinum and platinum-rhodium wires.<\/p>\n<p>The ceramic protection sheath therefore plays an important role in maintaining reliable measurement performance.<\/p>\n<p>The relatively small sheath diameter also supports fast thermal response.<\/p>\n<h2>Fast Thermal Response<\/h2>\n<p>The europascal EP-E168 features a thin ceramic protection sheath.<\/p>\n<p>This design reduces the thermal mass of the measuring assembly.<\/p>\n<p>A lower thermal mass can improve the response of the thermocouple to temperature changes.<\/p>\n<p>Fast thermal response is particularly useful during multi-point temperature calibration.<\/p>\n<p>When the calibration temperature changes, the reference thermocouple can respond efficiently to the new temperature conditions.<\/p>\n<p>The actual response time depends on the calibration medium, immersion depth and thermal contact.<\/p>\n<h2>Ideal for Dry Block Temperature Calibrators<\/h2>\n<p>The europascal EP-E168 was specifically developed for industrial calibration applications.<\/p>\n<p>One important application is the use as a reference thermometer in dry block temperature calibrators.<\/p>\n<p>Dry block calibrators generate controlled temperatures using a heated metal block.<\/p>\n<p>A reference thermometer and the device under test are inserted into suitable calibration wells.<\/p>\n<p>The reference thermometer measures the actual calibration temperature.<\/p>\n<p>The indication of the device under test can then be compared with the reference value.<\/p>\n<p>The compact construction of the europascal EP-E168 makes it particularly suitable for this measurement arrangement.<\/p>\n<p>Its small sheath diameter allows the thermocouple to be used in calibration inserts with relatively small bore diameters.<\/p>\n<p>For accurate comparison calibrations, the reference thermometer and device under test should be positioned in regions with comparable temperatures.<\/p>\n<h2>Reference Junction Compensation<\/h2>\n<p>Thermocouples measure temperature differences rather than absolute temperatures.<\/p>\n<p>Accurate temperature measurement therefore requires consideration of the reference junction temperature.<\/p>\n<p>The europascal EP-E168 can be used with an external reference junction.<\/p>\n<p>Alternatively, Type S miniature thermocouple connectors can be used.<\/p>\n<p>This provides flexibility when integrating the thermocouple into different measurement systems.<\/p>\n<p>When miniature thermocouple connectors are used, the reference junction compensation must be provided by the connected measurement instrument or another suitable arrangement.<\/p>\n<p>The manufacturer also describes configurations that avoid the use of compensating materials in the connecting cable.<\/p>\n<p>This can help reduce additional thermoelectric effects in demanding measurement applications.<\/p>\n<h2>Individual Calibration Parameters<\/h2>\n<p>The europascal EP-E168 is designed for use as a calibrated reference thermometer.<\/p>\n<p>The thermocouple characteristic follows DIN EN 60584.<\/p>\n<p>Individual parameters can be determined during calibration.<\/p>\n<p>These parameters describe the relationship between temperature and thermoelectric voltage for the individual thermocouple.<\/p>\n<p>Using individual calibration results can improve measurement accuracy compared with relying exclusively on the standardized thermocouple characteristic.<\/p>\n<p>The appropriate correction values and their uncertainties must be considered when evaluating calibration results.<\/p>\n<h2>DAkkS Calibration and Measurement Uncertainty<\/h2>\n<p>The europascal EP-E168 can be supplied with DAkkS calibration.<\/p>\n<p>The product datasheet provides measurement uncertainty values for fixed-point and comparison calibration.<\/p>\n<h3>Fixed-Point Calibration<\/h3>\n<div>\n<div>\n<div>\n<table>\n<thead>\n<tr>\n<th>Calibration Temperature<\/th>\n<th>Measurement Uncertainty<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0.01 \u00b0C<\/td>\n<td>0.2 K<\/td>\n<\/tr>\n<tr>\n<td>419.527 \u00b0C<\/td>\n<td>0.5 K<\/td>\n<\/tr>\n<tr>\n<td>660.323 \u00b0C<\/td>\n<td>0.5 K<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h3>Comparison Calibration<\/h3>\n<div>\n<div>\n<div>\n<table>\n<thead>\n<tr>\n<th>Temperature Range<\/th>\n<th>Measurement Uncertainty<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0 \u00b0C to 962 \u00b0C<\/td>\n<td>0.8 K<\/td>\n<\/tr>\n<tr>\n<td>Above 962 \u00b0C to 1200 \u00b0C<\/td>\n<td>1.5 K<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>These values are taken from the manufacturer&#8217;s datasheet.<\/p>\n<p>They describe the stated uncertainties associated with the specified calibration methods and must not be interpreted as the intrinsic accuracy of an uncalibrated thermocouple.<\/p>\n<p>The actual calibration uncertainty and calibration points are documented in the individual calibration certificate.<\/p>\n<p>For professional calibration services, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Compact Sensor Dimensions<\/h2>\n<p>The europascal EP-E168 features a compact construction optimized for industrial applications.<\/p>\n<p>The ceramic protection sheath has a diameter of:<\/p>\n<p><strong>5 mm<\/strong><\/p>\n<p>The protection sheath length is:<\/p>\n<p><strong>290 mm<\/strong><\/p>\n<p>The handle dimensions are:<\/p>\n<p><strong>12 mm diameter \u00d7 40 mm length<\/strong><\/p>\n<p>The maximum permissible continuous handle temperature is:<\/p>\n<p><strong>100 \u00b0C<\/strong><\/p>\n<p>The length of the thermocouple wires and connecting cable depends on the selected configuration.<\/p>\n<p>These dimensions make the reference thermocouple suitable for various industrial calibration arrangements.<\/p>\n<h2>Technical Highlights<\/h2>\n<div>\n<div>\n<div>\n<table>\n<thead>\n<tr>\n<th>Specification<\/th>\n<th>europascal EP-E168<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Manufacturer<\/td>\n<td>europascal<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>EP-E168<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Industrial Reference Thermocouple<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple type<\/td>\n<td>Type S<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>0 \u00b0C to 1200 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Positive thermocouple wire<\/td>\n<td>Pt10Rh<\/td>\n<\/tr>\n<tr>\n<td>Negative thermocouple wire<\/td>\n<td>Pt<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple material<\/td>\n<td>High-purity noble metals<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple wire treatment<\/td>\n<td>Thermally treated and annealed<\/td>\n<\/tr>\n<tr>\n<td>Protection sheath<\/td>\n<td>Gas-tight high-purity ceramic<\/td>\n<\/tr>\n<tr>\n<td>Protection sheath diameter<\/td>\n<td>5 mm<\/td>\n<\/tr>\n<tr>\n<td>Protection sheath length<\/td>\n<td>290 mm<\/td>\n<\/tr>\n<tr>\n<td>Handle diameter<\/td>\n<td>12 mm<\/td>\n<\/tr>\n<tr>\n<td>Handle length<\/td>\n<td>40 mm<\/td>\n<\/tr>\n<tr>\n<td>Maximum continuous handle temperature<\/td>\n<td>100 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple wire length<\/td>\n<td>Depending on configuration<\/td>\n<\/tr>\n<tr>\n<td>Connection cable length<\/td>\n<td>Depending on configuration<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple characteristic<\/td>\n<td>DIN EN 60584<\/td>\n<\/tr>\n<tr>\n<td>Individual calibration parameters<\/td>\n<td>Determined during calibration<\/td>\n<\/tr>\n<tr>\n<td>Reference junction<\/td>\n<td>External or suitable Type S miniature connector arrangement<\/td>\n<\/tr>\n<tr>\n<td>DAkkS calibration<\/td>\n<td>Available<\/td>\n<\/tr>\n<tr>\n<td>Carrying case<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Typical applications<\/td>\n<td>Industrial temperature calibration and dry block calibrators<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and reference thermocouples.<\/p>\n<p>The europascal EP-E168 is designed for applications requiring reliable reference temperature measurements.<\/p>\n<p>For demanding applications, the measurement uncertainty of the complete measuring system must be evaluated.<\/p>\n<p>Relevant uncertainty contributions may include the calibration uncertainty of the thermocouple, reference junction temperature, thermoelectric inhomogeneity, measurement instrument uncertainty, immersion effects and measurement repeatability.<\/p>\n<p>The individual uncertainty contributions should be evaluated according to the applicable calibration procedure and relevant metrological guidelines.<\/p>\n<p>Professional calibration supports reliable measurement results and long-term monitoring of reference thermometer performance.<\/p>\n<p>Further information is available through the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the europascal EP-E168?<\/h2>\n<p>The europascal EP-E168 combines high-quality noble metal thermocouple materials with a compact design optimized for industrial calibration.<\/p>\n<p>Its temperature range from 0 \u00b0C to 1200 \u00b0C covers numerous demanding temperature measurement applications.<\/p>\n<p>The Type S thermocouple element provides a standardized thermoelectric characteristic suitable for precision temperature measurement.<\/p>\n<p>Thermally treated and annealed thermocouple wires help reduce inhomogeneity.<\/p>\n<p>The gas-tight high-purity ceramic protection sheath helps protect the measuring element from contamination.<\/p>\n<p>The small sheath diameter and optimized construction make the thermocouple particularly suitable for dry block temperature calibrators.<\/p>\n<p>Individual calibration parameters allow the measurement performance of the thermocouple to be characterized.<\/p>\n<p>With DAkkS calibration available, the europascal EP-E168 is an excellent choice for industrial calibration laboratories and professional temperature metrology applications.<\/p>\n<h2>Typical Applications for the europascal EP-E168<\/h2>\n<p>The europascal EP-E168 is suitable for a wide range of industrial and laboratory applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Industrial temperature calibration<\/li>\n<li>Reference temperature measurement<\/li>\n<li>Dry block calibrator applications<\/li>\n<li>Thermocouple comparison calibration<\/li>\n<li>Temperature sensor calibration<\/li>\n<li>Calibration laboratory applications<\/li>\n<li>High-temperature measurement<\/li>\n<li>Industrial process monitoring<\/li>\n<li>Quality assurance<\/li>\n<li>Temperature metrology<\/li>\n<li>Calibration of temperature measuring instruments<\/li>\n<li>Reference measurements up to 1200 \u00b0C<\/li>\n<\/ul>\n<p>The combination of high-purity thermocouple materials, excellent construction quality and suitability for limited immersion depths makes the europascal EP-E168 a professional solution for demanding temperature calibration applications.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/europascal-EP-E168-Industrial-Reference-Thermoelement-Type-S.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>europascal EP-E168<\/strong> is a precision Type S reference thermocouple for temperatures from <strong>0 \u00b0C to 1200 \u00b0C<\/strong>. Featuring high-purity platinum-rhodium wires, a gas-tight ceramic sheath and a compact design optimized for small immersion depths, it is ideal for accurate temperature calibration in dry block calibrators and industrial laboratories.<\/p>\n","protected":false},"featured_media":6962,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4380],"product_cat":[58,53],"product_tag":[6035,6449,6450,6451,3920,6452,5967,6453,3922,4395,6454,6455,6456,5823,5323,6457,5979,3998,4000,4001,6446,4003,6458,5019],"class_list":["post-6961","product","type-product","status-publish","has-post-thumbnail","product_brand-europascal-2","product_cat-temperature-sensors","product_cat-temperature","product_tag-blockkalibrator","product_tag-dakks-kalibrierung-temperatur","product_tag-din-en-60584","product_tag-ep-e168","product_tag-europascal","product_tag-europascal-ep-e168","product_tag-hochtemperaturfuehler","product_tag-industrielle-temperaturmessung","product_tag-kalibrierlabor","product_tag-kalibriertechnik","product_tag-praezisionsthermoelement","product_tag-pt10rh-pt","product_tag-referenz-thermoelement","product_tag-referenztemperaturfuehler","product_tag-referenzthermoelement","product_tag-temperatur-blockkalibrator","product_tag-temperaturfuehler","product_tag-temperaturfuehler-kalibrieren","product_tag-temperaturkalibrierung","product_tag-temperaturmesstechnik","product_tag-temperaturnormal","product_tag-thermoelement-kalibrieren","product_tag-thermoelement-typ-s","product_tag-typ-s-thermoelement","pa_funktion-typ-s","pa_medium-thermoelement","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6961","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/6962"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6961"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6961"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6961"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6961"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}