{"id":6977,"date":"2026-07-17T16:58:20","date_gmt":"2026-07-17T16:58:20","guid":{"rendered":"https:\/\/europascal.de\/product\/additel-accumac-am1762\/"},"modified":"2026-10-14T10:10:09","modified_gmt":"2026-10-14T10:10:09","slug":"additel-accumac-am1762","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-accumac-am1762\/","title":{"rendered":"Additel AccuMac AM 1762 Precise Reference Thermometer"},"content":{"rendered":"<p>The <strong>Additel AccuMac AM 1762<\/strong> is a high-precision secondary standard platinum resistance thermometer (SPRT) designed for demanding temperature measurements and professional temperature calibration applications.<\/p>\n<p>With a temperature range from <strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong>, a nominal resistance of <strong>25 \u03a9 at the triple point of water<\/strong> and a calibrated accuracy of <strong>\u00b10.006 \u00b0C at 0.01 \u00b0C<\/strong>, the Additel AccuMac AM 1762 provides excellent measurement performance for calibration laboratories, research institutions and industrial temperature metrology.<\/p>\n<p>The thermometer combines outstanding short-term stability, low long-term drift and a robust Inconel sheath. Its specially designed platinum sensing element provides reliable performance even during repeated temperature cycles.<\/p>\n<p>The Additel AccuMac AM 1762 meets the relevant ITS-90 requirements for standard platinum resistance thermometers and is supplied with an ISO\/IEC 17025 accredited calibration.<\/p>\n<p>Two probe lengths are available, allowing users to select the appropriate configuration for their calibration equipment.<\/p>\n<p>At europascal, customers benefit from professional advice on reference thermometers, temperature calibration systems and metrological traceability.<\/p>\n<p>For additional information about professional calibration services, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The Additel AccuMac AM 1762 offers excellent performance for precision temperature measurement.<\/p>\n<p>Its most important advantages include:<\/p>\n<ul>\n<li>Temperature range from \u2212200 \u00b0C to +670 \u00b0C<\/li>\n<li>Secondary standard platinum resistance thermometer<\/li>\n<li>Nominal resistance of 25 \u03a9 at 0.01 \u00b0C<\/li>\n<li>Calibrated accuracy of \u00b10.006 \u00b0C at 0.01 \u00b0C<\/li>\n<li>Short-term stability better than 0.002 \u00b0C<\/li>\n<li>Long-term drift below 0.004 \u00b0C after 100 hours at 661 \u00b0C<\/li>\n<li>Temperature coefficient of 0.003925 \u03a9\/\u03a9\/\u00b0C<\/li>\n<li>Compliance with ITS-90 requirements for reference thermometers<\/li>\n<li>High-quality platinum sensing element<\/li>\n<li>Robust Inconel protective sheath<\/li>\n<li>Four-wire resistance measurement<\/li>\n<li>Recommended measurement current of 1 mA<\/li>\n<li>Low self-heating effect<\/li>\n<li>Fast response time of approximately 9 seconds<\/li>\n<li>Excellent thermal shock performance<\/li>\n<li>Probe diameter of 6.35 mm<\/li>\n<li>Available lengths of 305 mm and 508 mm<\/li>\n<li>ISO\/IEC 17025 accredited calibration included<\/li>\n<li>Suitable for calibration laboratories and industrial applications<\/li>\n<\/ul>\n<p>The combination of excellent stability, low drift and high temperature accuracy makes the Additel AccuMac AM 1762 a reliable reference thermometer for demanding calibration applications.<\/p>\n<h2>Temperature Range from \u2212200 \u00b0C to +670 \u00b0C<\/h2>\n<p>The Additel AccuMac AM 1762 covers a wide temperature range:<\/p>\n<p><strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong><\/p>\n<p>This makes the thermometer suitable for both cryogenic and high-temperature calibration applications.<\/p>\n<p>Typical measurement temperatures include:<\/p>\n<ul>\n<li>\u2212196 \u00b0C<\/li>\n<li>\u2212100 \u00b0C<\/li>\n<li>0.01 \u00b0C<\/li>\n<li>+100 \u00b0C<\/li>\n<li>+200 \u00b0C<\/li>\n<li>+420 \u00b0C<\/li>\n<li>+661 \u00b0C<\/li>\n<\/ul>\n<p>The wide operating range allows the thermometer to be used in different temperature calibration systems.<\/p>\n<p>These include liquid calibration baths, precision temperature furnaces and suitable dry block calibrators.<\/p>\n<p>The actual usable temperature range depends on the calibration setup, immersion depth and environmental conditions.<\/p>\n<p>The temperature range of the probe must also be distinguished from the calibrated temperature range stated on its individual calibration certificate.<\/p>\n<h2>Excellent Calibrated Accuracy<\/h2>\n<p>The Additel AccuMac AM 1762 provides excellent calibrated accuracy across its temperature range.<\/p>\n<p>The manufacturer specifies the following values:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature<\/th>\n<th>Calibrated Accuracy<\/th>\n<\/tr>\n<tr>\n<td>\u2212196 \u00b0C<\/td>\n<td>\u00b10.010 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>+0.01 \u00b0C<\/td>\n<td>\u00b10.006 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>+420 \u00b0C<\/td>\n<td>\u00b10.015 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>+661 \u00b0C<\/td>\n<td>\u00b10.025 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The values are specified with a coverage factor of <strong>k = 2<\/strong> and include the calibration contribution and the manufacturer&#8217;s defined drift allowance.<\/p>\n<p>These specifications demonstrate the thermometer&#8217;s suitability for precision temperature calibration.<\/p>\n<p>For demanding applications, the complete measurement uncertainty must be evaluated.<\/p>\n<p>The uncertainty of the thermometer readout, temperature source and calibration procedure must also be considered.<\/p>\n<h2>Excellent Short-Term Stability<\/h2>\n<p>The Additel AccuMac AM 1762 provides outstanding short-term stability.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>&lt; 0.002 \u00b0C<\/strong><\/p>\n<p>This corresponds to less than 2 mK.<\/p>\n<p>Excellent short-term stability is particularly important for comparison calibration.<\/p>\n<p>During a calibration procedure, the reference thermometer must provide reliable and repeatable measurements.<\/p>\n<p>A stable reference thermometer helps minimize measurement variations and supports accurate calibration results.<\/p>\n<h2>Low Long-Term Drift<\/h2>\n<p>Long-term stability is an essential characteristic of a high-quality reference thermometer.<\/p>\n<p>The Additel AccuMac AM 1762 provides excellent long-term performance.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>&lt; 0.004 \u00b0C after 100 hours at 661 \u00b0C<\/strong><\/p>\n<p>This drift is evaluated at the triple point of water.<\/p>\n<p>The value demonstrates the thermometer&#8217;s ability to maintain stable measurement characteristics even after prolonged exposure to high temperatures.<\/p>\n<p>Actual drift depends on handling, operating conditions and maintenance.<\/p>\n<p>Regular verification at a suitable reference temperature is recommended for demanding metrological applications.<\/p>\n<h2>Nominal Resistance of 25 \u03a9<\/h2>\n<p>The Additel AccuMac AM 1762 features a nominal resistance of:<\/p>\n<p><strong>25 \u03a9 at 0.01 \u00b0C<\/strong><\/p>\n<p>This distinguishes it from the Additel AccuMac AM 1760, which has a nominal resistance of 100 \u03a9.<\/p>\n<p>The AM 1762 is designed for precision resistance measurement using a suitable thermometer readout or resistance bridge.<\/p>\n<p>The thermometer has a temperature coefficient of:<\/p>\n<p><strong>0.003925 \u03a9\/\u03a9\/\u00b0C<\/strong><\/p>\n<p>This characteristic is typical of high-purity platinum reference thermometers.<\/p>\n<p>It differs from the nominal coefficient of industrial Pt100 sensors according to IEC 60751.<\/p>\n<p>For accurate temperature calculation, the individual calibration coefficients supplied with the thermometer should be used.<\/p>\n<h2>ITS-90 Reference Thermometer<\/h2>\n<p>The Additel AccuMac AM 1762 meets the relevant requirements of the International Temperature Scale of 1990 (ITS-90) for standard platinum resistance thermometers.<\/p>\n<p>ITS-90 provides an internationally recognized basis for accurate temperature measurement.<\/p>\n<p>The thermometer can be used as a secondary standard in suitable calibration systems.<\/p>\n<p>Individual calibration coefficients allow the relationship between resistance and temperature to be determined accurately.<\/p>\n<p>For high-precision applications, these coefficients are entered into a compatible reference thermometer readout or measurement system.<\/p>\n<p>This allows the specific characteristics of the individual thermometer to be considered.<\/p>\n<h2>Robust Inconel Protective Sheath<\/h2>\n<p>The Additel AccuMac AM 1762 features a high-quality Inconel sheath.<\/p>\n<p>Inconel is a nickel-based alloy known for its resistance to elevated temperatures and demanding environmental conditions.<\/p>\n<p>The protective sheath helps protect the platinum sensing element against mechanical influences and contamination.<\/p>\n<p>This is particularly important for reference thermometers that are used repeatedly in calibration laboratories.<\/p>\n<p>The robust construction supports reliable performance during daily operation.<\/p>\n<p>Nevertheless, the thermometer should be handled carefully to avoid mechanical shock, excessive bending and contamination.<\/p>\n<h2>Specially Designed Platinum Sensing Element<\/h2>\n<p>The Additel AccuMac AM 1762 uses a specially designed platinum sensing element.<\/p>\n<p>The construction protects the platinum wire against contamination at high temperatures.<\/p>\n<p>A dedicated internal support structure helps balance mechanical stability, thermal shock resistance and measurement performance.<\/p>\n<p>The manufacturer specifies a thermal shock effect of:<\/p>\n<p><strong>&lt; 0.002 \u00b0C after 10 temperature cycles<\/strong><\/p>\n<p>These cycles cover the specified minimum and maximum operating temperatures.<\/p>\n<p>The design helps maintain reliable measurement characteristics during repeated temperature changes.<\/p>\n<h2>Low Self-Heating Effect<\/h2>\n<p>Resistance thermometers require an electrical measurement current.<\/p>\n<p>This current produces a small amount of heat within the sensing element.<\/p>\n<p>The resulting temperature increase is known as self-heating.<\/p>\n<p>For the Additel AccuMac AM 1762, the manufacturer specifies:<\/p>\n<p><strong>0.0015 \u00b0C at 1 mA<\/strong><\/p>\n<p>This corresponds to approximately 1.5 mK.<\/p>\n<p>The specified measurement current is:<\/p>\n<p><strong>1 mA<\/strong><\/p>\n<p>For high-accuracy applications, the influence of self-heating should be evaluated under the actual measurement conditions.<\/p>\n<p>The self-heating effect depends on the measurement current and the thermal environment surrounding the sensor.<\/p>\n<h2>Fast Response Time<\/h2>\n<p>The Additel AccuMac AM 1762 provides a response time of approximately:<\/p>\n<p><strong>9 seconds<\/strong><\/p>\n<p>This value refers to a 63% response to a temperature step in moving water under the manufacturer&#8217;s specified conditions.<\/p>\n<p>The actual response time depends on the temperature medium, flow conditions and installation.<\/p>\n<p>Fast response is beneficial when measuring temperature changes or performing multi-point calibrations.<\/p>\n<p>However, sufficient stabilization time must always be allowed before recording precision calibration measurements.<\/p>\n<h2>Available Probe Lengths<\/h2>\n<p>The Additel AccuMac AM 1762 is available in two standard lengths.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<th>Probe Length<\/th>\n<th>Probe Diameter<\/th>\n<\/tr>\n<tr>\n<td>AM1762-12<\/td>\n<td>305 mm<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<tr>\n<td>AM1762-20<\/td>\n<td>508 mm<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Both configurations use the same nominal resistance and temperature measurement principle.<\/p>\n<p>The appropriate length depends on the required immersion depth and the calibration equipment.<\/p>\n<p>The longer version is particularly suitable for deeper calibration baths and furnaces.<\/p>\n<p>The shorter version can be advantageous when working with compact calibration systems.<\/p>\n<h2>Four-Wire Resistance Measurement<\/h2>\n<p>The Additel AccuMac AM 1762 uses a four-wire electrical connection.<\/p>\n<p>Four-wire resistance measurement minimizes errors caused by lead resistance.<\/p>\n<p>Two conductors supply the measurement current, while the other two conductors measure the voltage across the sensing element.<\/p>\n<p>This measurement principle is essential for high-accuracy platinum resistance thermometry.<\/p>\n<p>The thermometer can be connected to compatible precision resistance bridges and reference thermometer readouts.<\/p>\n<p>Suitable connection options should be selected according to the measurement instrument.<\/p>\n<h2>Compatibility with Reference Thermometer Readouts<\/h2>\n<p>The Additel AccuMac AM 1762 can be used with suitable high-precision thermometer readouts.<\/p>\n<p>For example, the <a href=\"https:\/\/europascal.de\/en\/product\/additel-adt-286\/\">Additel ADT 286 Multifunction Reference Thermometer Readout<\/a> supports precision resistance measurements and ITS-90 sensor characteristics.<\/p>\n<p>A compatible readout measures the resistance of the AM 1762 and calculates the corresponding temperature using its individual calibration coefficients.<\/p>\n<p>The complete measurement system consists of the reference thermometer, readout and temperature source.<\/p>\n<p>For high-accuracy applications, the uncertainty contributions of all components must be considered.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Additel AccuMac AM 1762<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Additel<\/td>\n<\/tr>\n<tr>\n<td>Product series<\/td>\n<td>AccuMac<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>AM 1762<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Secondary Standard Platinum Resistance Thermometer<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u2212200 \u00b0C to +670 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Nominal resistance at 0.01 \u00b0C<\/td>\n<td>25 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient<\/td>\n<td>0.003925 \u03a9\/\u03a9\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at \u2212196 \u00b0C<\/td>\n<td>\u00b10.010 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 0.01 \u00b0C<\/td>\n<td>\u00b10.006 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 420 \u00b0C<\/td>\n<td>\u00b10.015 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 661 \u00b0C<\/td>\n<td>\u00b10.025 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Coverage factor for accuracy<\/td>\n<td>k = 2<\/td>\n<\/tr>\n<tr>\n<td>Short-term stability<\/td>\n<td>&lt; 0.002 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Long-term drift<\/td>\n<td>&lt; 0.004 \u00b0C after 100 h at 661 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermal shock effect<\/td>\n<td>&lt; 0.002 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Self-heating at 1 mA<\/td>\n<td>0.0015 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Measurement current<\/td>\n<td>1 mA<\/td>\n<\/tr>\n<tr>\n<td>Response time<\/td>\n<td>Approx. 9 seconds<\/td>\n<\/tr>\n<tr>\n<td>Sensor length<\/td>\n<td>42 mm<\/td>\n<\/tr>\n<tr>\n<td>Sensor position<\/td>\n<td>5 mm from probe tip<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance<\/td>\n<td>&gt; 1000 M\u03a9 at room temperature<\/td>\n<\/tr>\n<tr>\n<td>Sheath material<\/td>\n<td>Inconel<\/td>\n<\/tr>\n<tr>\n<td>Probe diameter<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<tr>\n<td>Available probe lengths<\/td>\n<td>305 mm and 508 mm<\/td>\n<\/tr>\n<tr>\n<td>Electrical connection<\/td>\n<td>Four-wire<\/td>\n<\/tr>\n<tr>\n<td>Handle diameter<\/td>\n<td>15 mm<\/td>\n<\/tr>\n<tr>\n<td>Handle length<\/td>\n<td>65 mm<\/td>\n<\/tr>\n<tr>\n<td>Handle temperature range<\/td>\n<td>\u221250 \u00b0C to +180 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>ISO\/IEC 17025 accredited calibration included<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and reference thermometers.<\/p>\n<p>The Additel AccuMac AM 1762 can be integrated into a high-precision temperature calibration system using a suitable thermometer readout and temperature source.<\/p>\n<p>For demanding applications, the complete measurement uncertainty should be evaluated according to ISO\/IEC 17025 and applicable metrological guidelines.<\/p>\n<p>Relevant uncertainty contributions include the calibration uncertainty of the reference thermometer, long-term drift, self-heating, readout accuracy, temperature stability and immersion effects.<\/p>\n<p>The individual uncertainty contributions must be evaluated carefully to avoid double-counting effects already included in the manufacturer&#8217;s specifications.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<p>For additional information, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Additel AccuMac AM 1762?<\/h2>\n<p>The Additel AccuMac AM 1762 combines excellent temperature accuracy with outstanding stability and a robust mechanical design.<\/p>\n<p>Its wide temperature range from \u2212200 \u00b0C to +670 \u00b0C makes it suitable for demanding calibration applications.<\/p>\n<p>The nominal resistance of 25 \u03a9 and the temperature coefficient of 0.003925 \u03a9\/\u03a9\/\u00b0C make it particularly suitable for precision resistance thermometry.<\/p>\n<p>With calibrated accuracy of \u00b10.006 \u00b0C at the triple point of water and short-term stability better than 0.002 \u00b0C, the thermometer provides excellent measurement performance.<\/p>\n<p>The low long-term drift helps maintain reliable reference measurements during repeated use.<\/p>\n<p>The Inconel sheath protects the platinum sensing element and supports operation at elevated temperatures.<\/p>\n<p>Two available probe lengths provide flexibility for different calibration systems.<\/p>\n<p>The included ISO\/IEC 17025 accredited calibration provides documented metrological traceability.<\/p>\n<p>For calibration laboratories, research institutions and industrial users requiring a reliable secondary standard platinum resistance thermometer, the Additel AccuMac AM 1762 is an excellent choice.<\/p>\n<h2>Typical Calibration Applications<\/h2>\n<p>The Additel AccuMac AM 1762 is suitable for numerous precision temperature measurement applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Calibration of industrial Pt100 sensors<\/li>\n<li>Calibration of platinum resistance thermometers<\/li>\n<li>Comparison calibration of temperature sensors<\/li>\n<li>Temperature measurements in liquid calibration baths<\/li>\n<li>Temperature measurements in precision calibration furnaces<\/li>\n<li>Verification of dry block calibrators<\/li>\n<li>Temperature stability measurements<\/li>\n<li>Temperature uniformity investigations<\/li>\n<li>Laboratory reference temperature measurements<\/li>\n<li>Industrial temperature metrology<\/li>\n<li>Research and development<\/li>\n<li>Quality assurance<\/li>\n<li>Calibration laboratories<\/li>\n<li>ITS-90 temperature measurements<\/li>\n<li>High-precision resistance thermometry<\/li>\n<\/ul>\n<p>The combination of excellent accuracy, outstanding stability and robust construction makes the Additel AccuMac AM 1762 a professional reference thermometer for demanding temperature calibration applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/additel\/\">Find more Additel products here.<\/a><\/p>\n<p>Manufacturer information for the Additel AccuMac AM 1762 can be found on the <a href=\"https:\/\/www.additel.com\/product-detail.html\/am1760-am1762-secondary-sprts\/\" target=\"_blank\" rel=\"noopener\">official Additel website<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Additel-AccuMac-AM1760-AM1762-Secondary-SPRTs-22030625.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Additel AccuMac AM 1762<\/strong> is a high-precision secondary standard platinum resistance thermometer with a temperature range from <strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong>.\u00a0Featuring <strong>25 \u03a9 nominal resistance<\/strong>, calibrated accuracy of <strong>\u00b10.006 \u00b0C at 0.01 \u00b0C<\/strong> and excellent short-term stability of <strong>&lt; 0.002 \u00b0C<\/strong>, it is ideal for precision temperature calibration in laboratories and industrial applications. An <strong>ISO\/IEC 17025 accredited calibration<\/strong> is included.<\/p>\n","protected":false},"featured_media":3426,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[93,90],"product_cat":[58,53],"product_tag":[6502,6503,6504,6505,6506,3920,6507,6508,4095,4105,3922,6226,5027,6509,5893,4110,5958,6510,6465,6511,5979,4000,4113,4098],"class_list":["post-6977","product","type-product","status-publish","has-post-thumbnail","product_brand-accumac","product_brand-additel","product_cat-temperature-sensors","product_cat-temperature","product_tag-25-ohm-prt","product_tag-accumac-am-1762","product_tag-additel-accumac-am-1762","product_tag-am-1762","product_tag-am1762","product_tag-europascal","product_tag-fixpunktkalibrierung","product_tag-hochtemperatur-prt","product_tag-its-90","product_tag-kalibrierbad","product_tag-kalibrierlabor","product_tag-platin-widerstandsthermometer","product_tag-pt100-kalibrierung","product_tag-referenz-prt","product_tag-referenzfuehler","product_tag-referenzthermometer","product_tag-sekundaernormal-temperatur","product_tag-sekundaerstandard-prt","product_tag-sprt","product_tag-standard-platin-widerstandsthermometer","product_tag-temperaturfuehler","product_tag-temperaturkalibrierung","product_tag-temperaturmessung","product_tag-wassertripelpunkt","pa_funktion-sekundaere-referenz-widerstandsthermometer","pa_medium-widerstandsthermometer","pa_stabilitaet-0002-c","pa_temperaturbereich-200-c-bis-670-c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6977","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3426"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6977"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6977"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6977"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6977"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}