{"id":6979,"date":"2026-07-17T16:58:16","date_gmt":"2026-07-17T16:58:16","guid":{"rendered":"https:\/\/europascal.de\/product\/additel-accumac-am-1760\/"},"modified":"2026-10-14T10:20:26","modified_gmt":"2026-10-14T10:20:26","slug":"additel-accumac-am-1760","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-accumac-am-1760\/","title":{"rendered":"Additel AccuMac AM 1760 Precise Reference Thermometer"},"content":{"rendered":"<p>The <strong>Additel AccuMac AM 1760<\/strong> is a high-precision secondary standard platinum resistance thermometer designed for professional temperature measurement and calibration applications.<\/p>\n<p>With a temperature range from <strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong>, a nominal resistance of <strong>100 \u03a9<\/strong> and calibrated accuracy down to <strong>\u00b10.006 \u00b0C at the triple point of water<\/strong>, the Additel AccuMac AM 1760 provides excellent performance for demanding temperature metrology applications.<\/p>\n<p>The reference thermometer combines outstanding short-term stability with low long-term drift, a robust Inconel sheath and precise four-wire resistance measurement.<\/p>\n<p>It is particularly suitable for calibration laboratories, reference measurements, fixed-point calibrations and comparison calibrations of industrial temperature sensors.<\/p>\n<p>The Additel AccuMac AM 1760 meets the ITS-90 requirements for standard platinum resistance thermometers and is supplied with an ISO\/IEC 17025 accredited calibration.<\/p>\n<p>At europascal, customers benefit from professional temperature calibration equipment, technical expertise and comprehensive calibration services.<\/p>\n<p>For traceable calibration of reference thermometers and temperature sensors, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>High-precision secondary standard platinum resistance thermometer<\/li>\n<li>Wide temperature range from \u2212200 \u00b0C to +670 \u00b0C<\/li>\n<li>Nominal resistance of 100 \u03a9<\/li>\n<li>Temperature coefficient of 0.003925 \u03a9\/\u03a9\/\u00b0C<\/li>\n<li>Calibrated accuracy of \u00b10.006 \u00b0C at 0.01 \u00b0C<\/li>\n<li>Excellent short-term stability below 0.002 \u00b0C<\/li>\n<li>Long-term drift below 0.004 \u00b0C after 100 hours at 661 \u00b0C<\/li>\n<li>Excellent thermal shock performance<\/li>\n<li>Four-wire resistance measurement<\/li>\n<li>Low self-heating of approximately 0.0015 \u00b0C at 0.5 mA<\/li>\n<li>Robust Inconel protective sheath<\/li>\n<li>Probe diameter of 6.35 mm<\/li>\n<li>Two probe lengths available<\/li>\n<li>305 mm and approximately 500 mm versions<\/li>\n<li>Suitable for fixed-point and comparison calibrations<\/li>\n<li>Compatible with precision thermometer readouts<\/li>\n<li>Meets ITS-90 criteria for reference thermometers<\/li>\n<li>ISO\/IEC 17025 accredited calibration included<\/li>\n<\/ul>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p>The <strong>Additel AccuMac AM 1760<\/strong> was developed for applications requiring highly stable and reproducible temperature measurements.<\/p>\n<p>As a secondary standard platinum resistance thermometer, it provides a reliable reference for calibrating industrial temperature sensors and other precision thermometers.<\/p>\n<p>Typical applications include accredited calibration laboratories, industrial calibration departments, research institutions and temperature metrology laboratories.<\/p>\n<p>During comparison calibration, the reference thermometer and device under test are placed in a stable temperature source.<\/p>\n<p>The electrical resistance of the Additel AccuMac AM 1760 is measured using a suitable precision thermometer readout or resistance bridge.<\/p>\n<p>The measured resistance is converted into temperature using the individual calibration coefficients of the reference thermometer.<\/p>\n<p>This procedure allows accurate comparison measurements over a wide temperature range.<\/p>\n<p>The Additel AccuMac AM 1760 can be used with suitable calibration baths, temperature furnaces and fixed-point cells.<\/p>\n<p>For additional equipment, explore the <a href=\"https:\/\/europascal.de\/produkt-kategorie\/temperatur\/\">temperature measurement products at europascal<\/a>.<\/p>\n<h2>Temperature Range from \u2212200 \u00b0C to +670 \u00b0C<\/h2>\n<p>The Additel AccuMac AM 1760 covers a temperature range of:<\/p>\n<p><strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong><\/p>\n<p>This wide operating range makes the reference thermometer suitable for both low-temperature and high-temperature calibration applications.<\/p>\n<p>At low temperatures, the thermometer can be used for measurements near the boiling point of liquid nitrogen.<\/p>\n<p>At intermediate temperatures, it is suitable for precision measurements in calibration baths.<\/p>\n<p>At higher temperatures, the reference thermometer can be used in suitable calibration furnaces and fixed-point systems.<\/p>\n<p>The wide temperature range allows laboratories to perform numerous calibration tasks using a single reference thermometer.<\/p>\n<p>This reduces the need for multiple reference sensors and simplifies temperature calibration procedures.<\/p>\n<h2>High Accuracy of the Additel AccuMac AM 1760<\/h2>\n<p>The Additel AccuMac AM 1760 offers excellent calibrated accuracy.<\/p>\n<p>The manufacturer specifies the following values:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature<\/th>\n<th>Calibrated Accuracy<\/th>\n<\/tr>\n<tr>\n<td>\u2212196 \u00b0C<\/td>\n<td>\u00b10.007 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>0.01 \u00b0C<\/td>\n<td>\u00b10.006 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>420 \u00b0C<\/td>\n<td>\u00b10.015 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>660 \u00b0C<\/td>\n<td>\u00b10.025 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These values demonstrate the outstanding measurement performance of the reference thermometer.<\/p>\n<p>The accuracy of \u00b10.006 \u00b0C at the triple point of water makes the Additel AccuMac AM 1760 particularly suitable for demanding reference measurements.<\/p>\n<p>For complete measurement systems, additional uncertainty contributions must be considered.<\/p>\n<p>These include the thermometer readout, resistance measurement, self-heating, immersion depth and temperature source.<\/p>\n<p>The accuracy of the reference thermometer must therefore not be confused with the expanded measurement uncertainty of the complete calibration setup.<\/p>\n<h2>Excellent Short-Term Stability<\/h2>\n<p>The Additel AccuMac AM 1760 provides excellent short-term stability.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Less than 0.002 \u00b0C<\/strong><\/p>\n<p>This value demonstrates the high reproducibility of the platinum resistance sensing element.<\/p>\n<p>Short-term stability is particularly important during comparison calibrations.<\/p>\n<p>A stable reference thermometer helps minimize changes in the reference indication during a measurement sequence.<\/p>\n<p>This supports reliable calibration results and reduces uncertainty contributions associated with sensor instability.<\/p>\n<h2>Low Long-Term Drift<\/h2>\n<p>Long-term stability is an essential characteristic of a high-quality reference thermometer.<\/p>\n<p>The Additel AccuMac AM 1760 features a very low drift rate.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Less than 0.004 \u00b0C after 100 hours at 661 \u00b0C<\/strong><\/p>\n<p>This value refers to the resistance change evaluated at the triple point of water after the specified thermal exposure.<\/p>\n<p>The low drift demonstrates the stability of the sensing element even after prolonged operation at elevated temperatures.<\/p>\n<p>Regular calibration remains necessary to verify the long-term performance of the reference thermometer.<\/p>\n<h2>Excellent Thermal Shock Performance<\/h2>\n<p>Temperature reference sensors may experience significant thermal stress when moved between different temperature environments.<\/p>\n<p>The Additel AccuMac AM 1760 is designed to minimize changes caused by thermal cycling.<\/p>\n<p>The manufacturer specifies a change of:<\/p>\n<p><strong>Less than 0.002 \u00b0C after ten thermal cycles<\/strong><\/p>\n<p>The test involves cycling between the minimum and maximum specified temperatures.<\/p>\n<p>This characteristic supports reliable operation in laboratories where reference thermometers are regularly used at different temperatures.<\/p>\n<p>Nevertheless, careful handling and controlled temperature changes are recommended to protect the sensing element.<\/p>\n<h2>100 \u03a9 Nominal Resistance<\/h2>\n<p>The Additel AccuMac AM 1760 features a nominal resistance of:<\/p>\n<p><strong>100 \u03a9<\/strong><\/p>\n<p>The manufacturer specifies a temperature coefficient of:<\/p>\n<p><strong>0.003925 \u03a9\/\u03a9\/\u00b0C<\/strong><\/p>\n<p>This characteristic distinguishes the reference thermometer from conventional industrial Pt100 sensors according to IEC 60751.<\/p>\n<p>Industrial Pt100 sensors typically have a temperature coefficient of approximately 0.00385 \u03a9\/\u03a9\/\u00b0C.<\/p>\n<p>The Additel AccuMac AM 1760 is designed as a precision reference thermometer rather than a standard industrial RTD.<\/p>\n<p>For accurate measurements, the thermometer must be evaluated using its individual calibration coefficients.<\/p>\n<p>A compatible precision readout or resistance bridge is required.<\/p>\n<h2>Low Self-Heating<\/h2>\n<p>Resistance thermometers require an electrical measurement current.<\/p>\n<p>This current generates a small amount of heat within the sensing element.<\/p>\n<p>The resulting temperature increase is known as self-heating.<\/p>\n<p>For the Additel AccuMac AM 1760, the manufacturer specifies approximately:<\/p>\n<p><strong>0.0015 \u00b0C at a measurement current of 0.5 mA<\/strong><\/p>\n<p>The low self-heating supports accurate temperature measurements.<\/p>\n<p>For high-precision calibration, self-heating should still be considered in the measurement uncertainty evaluation.<\/p>\n<p>The actual effect depends on the measurement current and the thermal environment surrounding the sensing element.<\/p>\n<h2>Four-Wire Resistance Measurement<\/h2>\n<p>The Additel AccuMac AM 1760 uses four-wire resistance measurement technology.<\/p>\n<p>Two conductors supply the measurement current, while two additional conductors measure the voltage across the sensing element.<\/p>\n<p>This configuration significantly reduces errors caused by lead resistance.<\/p>\n<p>Four-wire measurement is particularly important for high-precision platinum resistance thermometers.<\/p>\n<p>It allows accurate resistance measurements even when the thermometer is connected using relatively long cables.<\/p>\n<p>The Additel AccuMac AM 1760 is equipped with four Teflon-insulated copper leads.<\/p>\n<h2>Robust Inconel Protective Sheath<\/h2>\n<p>The Additel AccuMac AM 1760 features a protective sheath made from Inconel.<\/p>\n<p>Inconel is a nickel-based alloy offering excellent temperature resistance and mechanical durability.<\/p>\n<p>The protective sheath helps protect the platinum sensing element from external influences.<\/p>\n<p>The probe diameter is:<\/p>\n<p><strong>6.35 mm<\/strong><\/p>\n<p>This diameter provides a suitable combination of mechanical strength and thermal performance.<\/p>\n<p>The sensing element is specially designed to reduce contamination effects at elevated temperatures.<\/p>\n<p>Its internal construction also supports good resistance to mechanical and thermal stress.<\/p>\n<h2>Two Available Probe Lengths<\/h2>\n<p>The Additel AccuMac AM 1760 is available in two probe lengths.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<th>Probe Length<\/th>\n<th>Diameter<\/th>\n<\/tr>\n<tr>\n<td>AM1760-12-SP<\/td>\n<td>305 mm<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<tr>\n<td>AM1760-20-SP<\/td>\n<td>500 mm<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The shorter version is suitable for many standard calibration baths and temperature sources.<\/p>\n<p>The longer version provides additional flexibility when greater immersion depths are required.<\/p>\n<p>Selecting the correct probe length is important for minimizing heat conduction errors.<\/p>\n<p>For precision temperature measurements, the sensing element must be positioned within the homogeneous region of the temperature source.<\/p>\n<h2>Sensor Position and Response Time<\/h2>\n<p>The Additel AccuMac AM 1760 features a sensing element approximately:<\/p>\n<p><strong>42 mm long<\/strong><\/p>\n<p>The sensing element is positioned approximately:<\/p>\n<p><strong>5 mm from the probe tip<\/strong><\/p>\n<p>The manufacturer specifies a response time of approximately:<\/p>\n<p><strong>9 seconds for 63% response<\/strong><\/p>\n<p>This value applies under defined conditions in moving water.<\/p>\n<p>The actual response time depends on the temperature source, immersion depth and thermal contact.<\/p>\n<p>For accurate calibration, sufficient time must be allowed for the reference thermometer and device under test to reach thermal equilibrium.<\/p>\n<h2>ISO\/IEC 17025 Accredited Calibration<\/h2>\n<p>The Additel AccuMac AM 1760 is supplied with an ISO\/IEC 17025 accredited calibration.<\/p>\n<p>This provides documented metrological traceability for professional temperature measurement applications.<\/p>\n<p>The individual calibration data can be used with a suitable precision thermometer readout.<\/p>\n<p>For laboratories operating according to ISO\/IEC 17025, regular monitoring of reference thermometer stability is recommended.<\/p>\n<p>This may include measurements at the triple point of water or other suitable reference temperatures.<\/p>\n<p>The calibration interval should be determined according to the required measurement uncertainty, frequency of use and observed long-term stability.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Additel AccuMac AM 1760<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Additel<\/td>\n<\/tr>\n<tr>\n<td>Product series<\/td>\n<td>AccuMac<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>AM 1760<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Secondary Standard Platinum Resistance Thermometer<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u2212200 \u00b0C to +670 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Nominal resistance<\/td>\n<td>100 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient<\/td>\n<td>0.003925 \u03a9\/\u03a9\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at \u2212196 \u00b0C<\/td>\n<td>\u00b10.007 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 0.01 \u00b0C<\/td>\n<td>\u00b10.006 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 420 \u00b0C<\/td>\n<td>\u00b10.015 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 660 \u00b0C<\/td>\n<td>\u00b10.025 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Short-term stability<\/td>\n<td>&lt;0.002 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Long-term drift<\/td>\n<td>&lt;0.004 \u00b0C after 100 hours at 661 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermal shock change<\/td>\n<td>&lt;0.002 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Self-heating<\/td>\n<td>Approx. 0.0015 \u00b0C at 0.5 mA<\/td>\n<\/tr>\n<tr>\n<td>Measurement current<\/td>\n<td>0.5 mA<\/td>\n<\/tr>\n<tr>\n<td>Probe diameter<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<tr>\n<td>Probe lengths<\/td>\n<td>305 mm or 500 mm<\/td>\n<\/tr>\n<tr>\n<td>Sensing element length<\/td>\n<td>42 mm<\/td>\n<\/tr>\n<tr>\n<td>Sensor position<\/td>\n<td>5 mm from tip<\/td>\n<\/tr>\n<tr>\n<td>Sheath material<\/td>\n<td>Inconel<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td>Four-wire<\/td>\n<\/tr>\n<tr>\n<td>Lead length<\/td>\n<td>2.5 m<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance<\/td>\n<td>&gt;1000 M\u03a9 at room temperature<\/td>\n<\/tr>\n<tr>\n<td>Response time<\/td>\n<td>Approx. 9 seconds<\/td>\n<\/tr>\n<tr>\n<td>Temperature scale<\/td>\n<td>ITS-90<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>ISO\/IEC 17025 accredited<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Additel AccuMac AM 1760 Compared with AM 1762<\/h2>\n<p>The Additel AccuMac AM 1760 and AM 1762 belong to the same family of secondary standard platinum resistance thermometers.<\/p>\n<p>Both models cover a temperature range from \u2212200 \u00b0C to +670 \u00b0C.<\/p>\n<p>They provide excellent accuracy, stability and repeatability.<\/p>\n<p>The main difference is their nominal resistance.<\/p>\n<p>The Additel AccuMac AM 1760 features a nominal resistance of 100 \u03a9.<\/p>\n<p>The AM 1762 features a nominal resistance of 25 \u03a9.<\/p>\n<p>The appropriate model should be selected according to the measurement capabilities of the precision thermometer readout or resistance bridge.<\/p>\n<p>For systems optimized for 100 \u03a9 reference thermometers, the Additel AccuMac AM 1760 is an excellent choice.<\/p>\n<h2>Why Choose the Additel AccuMac AM 1760?<\/h2>\n<p>The Additel AccuMac AM 1760 combines outstanding accuracy, excellent stability and robust construction.<\/p>\n<p>Its wide temperature range allows it to be used for numerous calibration tasks.<\/p>\n<p>The low drift rate supports reliable long-term performance.<\/p>\n<p>The four-wire connection reduces errors caused by lead resistance.<\/p>\n<p>The Inconel sheath provides mechanical protection and excellent temperature resistance.<\/p>\n<p>Two available probe lengths allow the thermometer to be adapted to different calibration systems.<\/p>\n<p>The included accredited calibration provides the traceability required for professional metrology applications.<\/p>\n<p>For laboratories requiring a reliable secondary standard thermometer, the Additel AccuMac AM 1760 offers an excellent combination of precision, flexibility and durability.<\/p>\n<h2>Typical Applications for the Additel AccuMac AM 1760<\/h2>\n<p>The Additel AccuMac AM 1760 is suitable for a wide range of professional temperature measurement applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Calibration of industrial Pt100 sensors<\/li>\n<li>Calibration of precision resistance thermometers<\/li>\n<li>Reference temperature measurements<\/li>\n<li>Temperature comparison calibrations<\/li>\n<li>Fixed-point measurements<\/li>\n<li>Triple point of water measurements<\/li>\n<li>Calibration baths<\/li>\n<li>Temperature calibration furnaces<\/li>\n<li>Precision temperature measurements<\/li>\n<li>Temperature source characterization<\/li>\n<li>Research and development<\/li>\n<li>Accredited calibration laboratories<\/li>\n<li>Industrial calibration laboratories<\/li>\n<li>Temperature metrology<\/li>\n<li>Quality assurance<\/li>\n<li>Reference standard monitoring<\/li>\n<\/ul>\n<p>During comparison calibration, the reference thermometer and device under test are placed in a stable and homogeneous temperature environment.<\/p>\n<p>The resistance of the reference thermometer is measured using a suitable precision readout.<\/p>\n<p>The individual calibration coefficients are then used to determine the reference temperature.<\/p>\n<p>europascal supports customers with suitable reference thermometers, precision temperature readouts, calibration baths and temperature calibration equipment.<\/p>\n<p>For professional calibration and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/additel\/\">Find more Additel products here.<\/a><\/p>\n<p>Manufacturer information for the Additel AccuMac AM 1760 can be found on the <a href=\"https:\/\/www.additel.com\/product-detail.html\/am1760-am1762-secondary-sprts\/\" target=\"_blank\" rel=\"noopener\">official Additel website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Additel-AccuMac-AM1760-AM1762-Secondary-SPRTs-22030625.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Additel AccuMac AM 1760<\/strong> is a high-precision secondary standard platinum resistance thermometer for temperatures from <strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong>.\u00a0Featuring accuracy down to <strong>\u00b10.006 \u00b0C<\/strong>, short-term stability below <strong>0.002 \u00b0C<\/strong> and a robust Inconel sheath, it is ideal for demanding temperature calibration applications.\u00a0An <strong>ISO\/IEC 17025 accredited calibration<\/strong> is included.<\/p>\n","protected":false},"featured_media":3426,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[93,90],"product_cat":[58,53],"product_tag":[6514,6515,6516,6517,6505,6518,3920,6507,6508,4095,4105,3922,6226,5027,6509,5893,4110,6519,5958,6510,6511,5979,4000,4113,4098],"class_list":["post-6979","product","type-product","status-publish","has-post-thumbnail","product_brand-accumac","product_brand-additel","product_cat-temperature-sensors","product_cat-temperature","product_tag-100-ohm-prt","product_tag-accumac-am-1760","product_tag-additel-accumac-am-1760","product_tag-am-1760","product_tag-am-1762","product_tag-am1760","product_tag-europascal","product_tag-fixpunktkalibrierung","product_tag-hochtemperatur-prt","product_tag-its-90","product_tag-kalibrierbad","product_tag-kalibrierlabor","product_tag-platin-widerstandsthermometer","product_tag-pt100-kalibrierung","product_tag-referenz-prt","product_tag-referenzfuehler","product_tag-referenzthermometer","product_tag-secondary-sprt","product_tag-sekundaernormal-temperatur","product_tag-sekundaerstandard-prt","product_tag-standard-platin-widerstandsthermometer","product_tag-temperaturfuehler","product_tag-temperaturkalibrierung","product_tag-temperaturmessung","product_tag-wassertripelpunkt","pa_funktion-sekundaere-referenz-widerstandsthermometer","pa_medium-widerstandsthermometer","pa_stabilitaet-0002-c","pa_temperaturbereich-200-c-bis-670-c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6979","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3426"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6979"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6979"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6979"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6979"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}