{"id":6985,"date":"2026-07-17T16:58:00","date_gmt":"2026-07-17T16:58:00","guid":{"rendered":"https:\/\/europascal.de\/product\/additel-accumac-am-1710\/"},"modified":"2026-10-14T10:48:53","modified_gmt":"2026-10-14T10:48:53","slug":"additel-accumac-am-1710","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-accumac-am-1710\/","title":{"rendered":"Additel AccuMac AM 1710 Precise Reference Thermometer"},"content":{"rendered":"<p>The <strong>Additel AccuMac AM 1710<\/strong> is a high-precision secondary reference platinum resistance thermometer designed for accurate temperature measurement and calibration in professional laboratories and industrial applications.<\/p>\n<p>With a temperature range from <strong>\u221240 \u00b0C to +160 \u00b0C<\/strong>, excellent short-term stability of less than <strong>0.007 \u00b0C<\/strong> and calibrated accuracy values as low as <strong>\u00b10.015 \u00b0C<\/strong>, the Additel AccuMac AM 1710 provides reliable performance for demanding temperature calibration tasks.<\/p>\n<p>The thermometer features a specially designed platinum sensing element that minimizes contamination, hysteresis and the effects of mechanical and thermal shock.<\/p>\n<p>Its robust stainless steel construction makes it suitable for laboratory applications and mobile temperature calibration.<\/p>\n<p>The Additel AccuMac AM 1710 meets the relevant ITS-90 criteria for reference thermometers and is supplied with an <strong>ISO\/IEC 17025 accredited calibration certificate<\/strong>.<\/p>\n<p>Two mechanical configurations are available: a straight reference probe and a version with a 90-degree bend.<\/p>\n<p>The thermometer is particularly suitable for comparison calibrations in temperature baths, dry block calibrators and other controlled temperature environments.<\/p>\n<p>europascal offers professional temperature measurement equipment and supports customers with technical advice and calibration services.<\/p>\n<p>For more information about traceable temperature calibration, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The Additel AccuMac AM 1710 combines excellent measurement performance with a durable construction.<\/p>\n<p>Its main advantages include:<\/p>\n<ul>\n<li>Temperature range from \u221240 \u00b0C to +160 \u00b0C<\/li>\n<li>Secondary reference platinum resistance thermometer<\/li>\n<li>Calibrated accuracy of \u00b10.015 \u00b0C at 0.01 \u00b0C<\/li>\n<li>Calibrated accuracy of \u00b10.025 \u00b0C at \u221240 \u00b0C<\/li>\n<li>Calibrated accuracy of \u00b10.025 \u00b0C at +160 \u00b0C<\/li>\n<li>Short-term stability better than 0.007 \u00b0C<\/li>\n<li>Long-term drift below 0.01 \u00b0C under specified conditions<\/li>\n<li>Temperature hysteresis of 0.005 \u00b0C or less<\/li>\n<li>Excellent resistance to thermal shock<\/li>\n<li>Nominal resistance of 100 \u03a9 at 0.01 \u00b0C<\/li>\n<li>Temperature coefficient of 0.003925 \u03a9\/\u03a9\/\u00b0C<\/li>\n<li>Four-wire resistance measurement<\/li>\n<li>Stainless steel probe sheath<\/li>\n<li>Probe diameter of 6.35 mm<\/li>\n<li>Straight and angled versions available<\/li>\n<li>Fast response time of approximately 9 seconds<\/li>\n<li>High insulation resistance<\/li>\n<li>Compatible with suitable precision thermometer readouts<\/li>\n<li>ISO\/IEC 17025 accredited calibration included<\/li>\n<li>Suitable for laboratory and field calibration<\/li>\n<\/ul>\n<h2>Ideal for Demanding Temperature Calibration Applications<\/h2>\n<p>The Additel AccuMac AM 1710 is designed for applications requiring highly accurate and repeatable temperature measurements.<\/p>\n<p>As a secondary reference thermometer, it can be used to determine the temperature of a calibration medium or temperature source.<\/p>\n<p>Typical applications include comparison calibration of industrial resistance thermometers, verification of temperature indicators and monitoring of calibration baths.<\/p>\n<p>The thermometer can also serve as a reference sensor in suitable dry block calibration systems.<\/p>\n<p>Its temperature range covers numerous applications in industrial production, pharmaceutical manufacturing, food processing and quality assurance.<\/p>\n<p>For accurate results, the reference thermometer must be used with a compatible precision resistance measurement instrument.<\/p>\n<h2>Temperature Range from \u221240 \u00b0C to +160 \u00b0C<\/h2>\n<p>The Additel AccuMac AM 1710 operates over a temperature range of:<\/p>\n<p><strong>\u221240 \u00b0C to +160 \u00b0C<\/strong><\/p>\n<p>This range covers common temperature calibration points below and above ambient temperature.<\/p>\n<p>Typical calibration temperatures include:<\/p>\n<ul>\n<li>\u221240 \u00b0C<\/li>\n<li>\u221220 \u00b0C<\/li>\n<li>0 \u00b0C<\/li>\n<li>25 \u00b0C<\/li>\n<li>50 \u00b0C<\/li>\n<li>75 \u00b0C<\/li>\n<li>100 \u00b0C<\/li>\n<li>125 \u00b0C<\/li>\n<li>160 \u00b0C<\/li>\n<\/ul>\n<p>The thermometer is suitable for temperature calibration applications in controlled liquid baths and appropriate dry block calibrators.<\/p>\n<p>The actual calibration range of an individual probe should be checked against its calibration certificate.<\/p>\n<h2>High Calibrated Accuracy<\/h2>\n<p>The Additel AccuMac AM 1710 offers excellent calibrated accuracy.<\/p>\n<p>The manufacturer specifies the following values:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Temperature<\/th>\n<th>Calibrated Accuracy<\/th>\n<\/tr>\n<tr>\n<td>\u221240 \u00b0C<\/td>\n<td>\u00b10.025 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>0.01 \u00b0C<\/td>\n<td>\u00b10.015 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>+160 \u00b0C<\/td>\n<td>\u00b10.025 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These values are specified with a coverage factor of <strong>k = 2<\/strong> and include calibration and the manufacturer&#8217;s defined drift contribution.<\/p>\n<p>The accuracy values demonstrate the suitability of the thermometer for demanding comparison calibrations.<\/p>\n<p>For metrological applications, the uncertainty of the complete measurement system must also include the resistance readout, temperature source and relevant application-specific influences.<\/p>\n<h2>Excellent Short-Term Stability<\/h2>\n<p>The Additel AccuMac AM 1710 provides excellent short-term stability.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>&lt; 0.007 \u00b0C<\/strong><\/p>\n<p>This characteristic describes the ability of the thermometer to maintain a stable indication over a short period under defined conditions.<\/p>\n<p>Good short-term stability is particularly important when performing comparison measurements.<\/p>\n<p>It helps reduce measurement variations during calibration procedures.<\/p>\n<p>The stable sensing element makes the AM 1710 suitable for applications requiring repeatable temperature measurements.<\/p>\n<h2>Low Long-Term Drift<\/h2>\n<p>The Additel AccuMac AM 1710 is designed for excellent long-term stability.<\/p>\n<p>The manufacturer specifies a long-term drift of:<\/p>\n<p><strong>&lt; 0.01 \u00b0C<\/strong><\/p>\n<p>This value refers to measurements at the triple point of water after 100 hours of exposure to 160 \u00b0C.<\/p>\n<p>The actual drift of a thermometer depends on its handling, operating conditions and maintenance.<\/p>\n<p>Regular recalibration is recommended to monitor changes in the thermometer characteristics.<\/p>\n<p>For demanding applications, intermediate checks at a suitable reference temperature can help identify unexpected changes.<\/p>\n<h2>Excellent Resistance to Thermal Shock<\/h2>\n<p>The Additel AccuMac AM 1710 is designed to withstand repeated temperature changes.<\/p>\n<p>The manufacturer specifies a thermal shock effect of:<\/p>\n<p><strong>&lt; 0.005 \u00b0C<\/strong><\/p>\n<p>This value applies after ten thermal cycles between the minimum and maximum operating temperatures.<\/p>\n<p>The sensing element is protected by a specially designed support structure.<\/p>\n<p>This construction helps reduce mechanical stress on the platinum sensing wire.<\/p>\n<p>It also contributes to the thermometer&#8217;s excellent repeatability.<\/p>\n<h2>Low Temperature Hysteresis<\/h2>\n<p>The Additel AccuMac AM 1710 provides low temperature hysteresis.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>\u2264 0.005 \u00b0C<\/strong><\/p>\n<p>Temperature hysteresis describes the difference in thermometer indication that may occur when the same temperature is approached from different directions.<\/p>\n<p>Low hysteresis is particularly important for calibration procedures involving both heating and cooling sequences.<\/p>\n<p>The special sensing element construction helps minimize these effects.<\/p>\n<h2>Platinum Resistance Sensor<\/h2>\n<p>The Additel AccuMac AM 1710 uses a precision platinum resistance sensing element.<\/p>\n<p>The nominal resistance is:<\/p>\n<p><strong>100 \u03a9 at 0.01 \u00b0C<\/strong><\/p>\n<p>The temperature coefficient is:<\/p>\n<p><strong>0.003925 \u03a9\/\u03a9\/\u00b0C<\/strong><\/p>\n<p>This coefficient differs from the commonly used industrial Pt100 coefficient of 0.00385 \u03a9\/\u03a9\/\u00b0C.<\/p>\n<p>Therefore, the AM 1710 should not automatically be configured as a standard IEC 60751 Pt100 sensor.<\/p>\n<p>For accurate temperature measurements, the resistance readout must use the correct thermometer characteristics and the individual calibration coefficients.<\/p>\n<p>The thermometer is designed to meet the relevant ITS-90 criteria for reference thermometers.<\/p>\n<h2>Four-Wire Resistance Measurement<\/h2>\n<p>The Additel AccuMac AM 1710 features a four-wire connection.<\/p>\n<p>Four-wire resistance measurement minimizes the influence of lead resistance.<\/p>\n<p>This is particularly important when measuring small resistance changes with high accuracy.<\/p>\n<p>The thermometer is equipped with four insulated copper leads.<\/p>\n<p>A suitable precision thermometer readout or resistance measurement instrument is required.<\/p>\n<p>The reference thermometer itself does not contain an integrated temperature display.<\/p>\n<h2>Fast Response Time<\/h2>\n<p>The Additel AccuMac AM 1710 provides a response time of approximately:<\/p>\n<p><strong>9 seconds<\/strong><\/p>\n<p>This value refers to the time required to reach 63% of a temperature step change in moving water under the manufacturer&#8217;s specified conditions.<\/p>\n<p>The actual response time depends on the measurement medium, flow conditions and immersion depth.<\/p>\n<p>Fast response improves efficiency when performing temperature comparison measurements.<\/p>\n<h2>Stainless Steel Construction<\/h2>\n<p>The Additel AccuMac AM 1710 features a stainless steel probe sheath.<\/p>\n<p>The sheath protects the platinum sensing element against mechanical damage.<\/p>\n<p>The manufacturer specifies a probe diameter of:<\/p>\n<p><strong>6.35 mm<\/strong><\/p>\n<p>The stainless steel construction provides durability for regular laboratory use.<\/p>\n<p>The thermometer should nevertheless be handled carefully to avoid mechanical stress and damage to the sensing element.<\/p>\n<h2>Straight and Angled Versions<\/h2>\n<p>The Additel AccuMac AM 1710 is available in two mechanical configurations.<\/p>\n<h3>AM1710-12<\/h3>\n<p>The straight version features a probe length of:<\/p>\n<p><strong>305 mm<\/strong><\/p>\n<p>The probe diameter is:<\/p>\n<p><strong>6.35 mm<\/strong><\/p>\n<p>This configuration is suitable for conventional calibration baths and dry block calibrators.<\/p>\n<h3>AM1710-BEND<\/h3>\n<p>The angled version features a 90-degree bend.<\/p>\n<p>The manufacturer specifies approximately:<\/p>\n<p><strong>178 mm from the probe tip to the bend<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>101.6 mm from the bend to the handle<\/strong><\/p>\n<p>The angled configuration is useful when installation space is limited.<\/p>\n<p>It can also simplify measurements in calibration equipment where a straight probe would be difficult to position.<\/p>\n<h2>Sensor Element Dimensions<\/h2>\n<p>The platinum sensing element has a length of approximately:<\/p>\n<p><strong>32 mm<\/strong><\/p>\n<p>The sensing element is positioned approximately:<\/p>\n<p><strong>3 mm from the probe tip<\/strong><\/p>\n<p>The sensing element position is important when determining the required immersion depth.<\/p>\n<p>For accurate calibration, the entire sensing element must be exposed to a sufficiently uniform temperature.<\/p>\n<p>Additional immersion depth may be required to reduce heat conduction effects along the probe stem.<\/p>\n<h2>High Insulation Resistance<\/h2>\n<p>The Additel AccuMac AM 1710 provides high electrical insulation resistance.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>&gt; 1000 M\u03a9 at room temperature<\/strong><\/p>\n<p>High insulation resistance helps minimize measurement errors caused by leakage currents.<\/p>\n<p>This characteristic is particularly important for precision resistance thermometry.<\/p>\n<p>The insulation resistance should be monitored if the thermometer is exposed to demanding environmental conditions.<\/p>\n<h2>Compatibility with Precision Thermometer Readouts<\/h2>\n<p>The Additel AccuMac AM 1710 can be used with suitable precision thermometer readouts.<\/p>\n<p>Examples include compatible Additel reference thermometer instruments.<\/p>\n<p>The Additel 282 dual-channel reference thermometer readout and the Additel 286 multifunction reference thermometer readout are potential components of a precision temperature measurement system.<\/p>\n<p>The selected readout must support the required four-wire resistance measurement and the thermometer&#8217;s calibration characteristics.<\/p>\n<p>Depending on the connector configuration, an appropriate adapter may be required.<\/p>\n<h2>Available Connection Options<\/h2>\n<p>The Additel AccuMac AM 1710 is available with different connection options.<\/p>\n<p>These include:<\/p>\n<p><strong>ADT smart connection<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>SP spade connection<\/strong><\/p>\n<p>The ADT smart connector is designed for compatible Additel temperature measurement equipment.<\/p>\n<p>Spade connections allow use with suitable four-wire resistance measurement instruments.<\/p>\n<p>The appropriate connection type should be selected according to the intended thermometer readout.<\/p>\n<h2>ISO\/IEC 17025 Accredited Calibration Included<\/h2>\n<p>The Additel AccuMac AM 1710 is supplied with an ISO\/IEC 17025 accredited calibration.<\/p>\n<p>This provides documented metrological traceability for the reference thermometer.<\/p>\n<p>The calibration certificate contains information relevant to the individual thermometer.<\/p>\n<p>For professional calibration applications, the calibration data should be used to configure the measurement system correctly.<\/p>\n<p>Regular recalibration helps maintain confidence in the thermometer&#8217;s measurement performance.<\/p>\n<p>The appropriate calibration interval depends on usage, stability history and the required measurement uncertainty.<\/p>\n<h2>Technical Highlights<\/h2>\n<p>The Additel AccuMac AM 1710 provides the following technical characteristics.<\/p>\n<p>Model: Additel AccuMac AM 1710<\/p>\n<p>Device type: Secondary Reference Platinum Resistance Thermometer<\/p>\n<p>Temperature range: \u221240 \u00b0C to +160 \u00b0C<\/p>\n<p>Nominal resistance: 100 \u03a9 at 0.01 \u00b0C<\/p>\n<p>Temperature coefficient: 0.003925 \u03a9\/\u03a9\/\u00b0C<\/p>\n<p>Calibrated accuracy at \u221240 \u00b0C: \u00b10.025 \u00b0C<\/p>\n<p>Calibrated accuracy at 0.01 \u00b0C: \u00b10.015 \u00b0C<\/p>\n<p>Calibrated accuracy at +160 \u00b0C: \u00b10.025 \u00b0C<\/p>\n<p>Short-term stability: &lt; 0.007 \u00b0C<\/p>\n<p>Long-term drift: &lt; 0.01 \u00b0C under specified conditions<\/p>\n<p>Thermal shock: &lt; 0.005 \u00b0C<\/p>\n<p>Hysteresis: \u2264 0.005 \u00b0C<\/p>\n<p>Response time: 9 seconds<\/p>\n<p>Probe diameter: 6.35 mm<\/p>\n<p>Straight probe length: 305 mm<\/p>\n<p>Sensor element length: 32 mm<\/p>\n<p>Sensor element position: 3 mm from tip<\/p>\n<p>Insulation resistance: &gt; 1000 M\u03a9 at room temperature<\/p>\n<p>Sheath material: Stainless steel<\/p>\n<p>Connection: Four-wire<\/p>\n<p>Calibration: ISO\/IEC 17025 accredited<\/p>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Additel AccuMac AM 1710<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Additel<\/td>\n<\/tr>\n<tr>\n<td>Product series<\/td>\n<td>AccuMac<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>AM 1710<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Secondary Reference PRT<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u221240 \u00b0C to +160 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Nominal resistance at 0.01 \u00b0C<\/td>\n<td>100 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient<\/td>\n<td>0.003925 \u03a9\/\u03a9\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibrated accuracy at \u221240 \u00b0C<\/td>\n<td>\u00b10.025 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibrated accuracy at 0.01 \u00b0C<\/td>\n<td>\u00b10.015 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibrated accuracy at +160 \u00b0C<\/td>\n<td>\u00b10.025 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Coverage factor for calibrated accuracy<\/td>\n<td>k = 2<\/td>\n<\/tr>\n<tr>\n<td>Short-term stability<\/td>\n<td>&lt; 0.007 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Long-term drift<\/td>\n<td>&lt; 0.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermal shock effect<\/td>\n<td>&lt; 0.005 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Hysteresis<\/td>\n<td>\u2264 0.005 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Self-heating specification<\/td>\n<td>50 mW\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Response time<\/td>\n<td>9 seconds<\/td>\n<\/tr>\n<tr>\n<td>Sheath diameter<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<tr>\n<td>Straight probe length<\/td>\n<td>305 mm<\/td>\n<\/tr>\n<tr>\n<td>Sensor element length<\/td>\n<td>32 mm<\/td>\n<\/tr>\n<tr>\n<td>Sensor element position<\/td>\n<td>3 mm from tip<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance<\/td>\n<td>&gt; 1000 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Sheath material<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Number of leads<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Cable length<\/td>\n<td>2 m<\/td>\n<\/tr>\n<tr>\n<td>Handle diameter<\/td>\n<td>15 mm<\/td>\n<\/tr>\n<tr>\n<td>Handle length<\/td>\n<td>65 mm<\/td>\n<\/tr>\n<tr>\n<td>Available configurations<\/td>\n<td>Straight and 90\u00b0 bend<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>ISO\/IEC 17025 accredited<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Additel AccuMac AM 1710 or AM 1730?<\/h2>\n<p>The Additel AccuMac AM 1710 and AM 1730 are both secondary reference platinum resistance thermometers.<\/p>\n<p>However, they are designed for different temperature ranges.<\/p>\n<p>The AM 1710 covers:<\/p>\n<p><strong>\u221240 \u00b0C to +160 \u00b0C<\/strong><\/p>\n<p>The AM 1730 covers:<\/p>\n<p><strong>\u2212200 \u00b0C to +420 \u00b0C<\/strong><\/p>\n<p>The AM 1710 is particularly suitable for applications requiring high accuracy within a moderate temperature range.<\/p>\n<p>The AM 1730 is designed for applications requiring a wider temperature range.<\/p>\n<p>The correct model should be selected according to the required calibration temperatures, sensor geometry and measurement uncertainty.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and reference equipment.<\/p>\n<p>When the Additel AccuMac AM 1710 is used as a reference thermometer, the measurement uncertainty of the complete system must be evaluated.<\/p>\n<p>Relevant uncertainty contributions may include the calibration uncertainty of the reference thermometer, resistance measurement uncertainty, temperature stability, immersion effects, self-heating, hysteresis and long-term drift.<\/p>\n<p>The measurement uncertainty should be evaluated according to the applicable calibration procedure and relevant metrological guidelines.<\/p>\n<p>For professional temperature calibration services, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Additel AccuMac AM 1710?<\/h2>\n<p>The Additel AccuMac AM 1710 combines excellent temperature measurement accuracy with a robust and practical design.<\/p>\n<p>Its temperature range from \u221240 \u00b0C to +160 \u00b0C covers numerous laboratory and industrial calibration applications.<\/p>\n<p>The calibrated accuracy of \u00b10.015 \u00b0C at 0.01 \u00b0C makes the thermometer suitable for demanding precision measurements.<\/p>\n<p>Excellent short-term stability and low hysteresis help ensure repeatable measurement results.<\/p>\n<p>The stainless steel sheath and specially designed platinum sensing element provide resistance to mechanical and thermal stress.<\/p>\n<p>Straight and angled versions offer flexibility for different calibration setups.<\/p>\n<p>Four-wire measurement minimizes errors caused by lead resistance.<\/p>\n<p>The included ISO\/IEC 17025 accredited calibration provides documented metrological traceability.<\/p>\n<p>For calibration laboratories, industrial quality assurance and precision temperature measurement applications, the Additel AccuMac AM 1710 provides an excellent combination of accuracy, stability and durability.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the Additel AccuMac AM 1710<\/h2>\n<p>The Additel AccuMac AM 1710 is suitable for numerous professional temperature measurement applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Reference temperature measurement<\/li>\n<li>Comparison calibration<\/li>\n<li>Pt100 calibration<\/li>\n<li>Pt1000 calibration<\/li>\n<li>RTD calibration<\/li>\n<li>Temperature bath monitoring<\/li>\n<li>Dry block calibrator reference measurements<\/li>\n<li>Precision thermometer verification<\/li>\n<li>Industrial temperature measurement<\/li>\n<li>Pharmaceutical manufacturing<\/li>\n<li>Food processing<\/li>\n<li>Environmental testing<\/li>\n<li>Calibration laboratories<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Temperature metrology<\/li>\n<li>Field calibration<\/li>\n<\/ul>\n<p>The combination of high accuracy, excellent stability, robust construction and accredited calibration makes the Additel AccuMac AM 1710 a professional reference thermometer for demanding temperature calibration applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/additel\/\">Find more Additel products here.<\/a><\/p>\n<p>Manufacturer information for the Additel AccuMac AM 1710 can be found on the <a href=\"https:\/\/additel.com\/product-detail.html\/am1710-secondary-reference-prt\/\" target=\"_blank\" rel=\"noopener\">official Additel website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Additel-Accumac-AM1710-Secondary-Reference-Prts-20250226.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Additel AccuMac AM 1710<\/strong> is a precision secondary reference platinum resistance thermometer for temperatures from <strong>\u221240 \u00b0C to +160 \u00b0C<\/strong>. With calibrated accuracy down to <strong>\u00b10.015 \u00b0C<\/strong>, short-term stability better than <strong>0.007 \u00b0C<\/strong> and a robust stainless steel design, it is ideal for laboratory and field temperature calibration. An <strong>ISO\/IEC 17025 accredited calibration<\/strong> is included.<\/p>\n","protected":false},"featured_media":3423,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[93,90],"product_cat":[58,53],"product_tag":[6514,6534,6535,6536,6537,6538,5972,3920,4095,4105,3922,6226,6463,5027,6509,5893,4110,6532,5958,5979,4000,4113,4402],"class_list":["post-6985","product","type-product","status-publish","has-post-thumbnail","product_brand-accumac","product_brand-additel","product_cat-temperature-sensors","product_cat-temperature","product_tag-100-ohm-prt","product_tag-accumac-am-1710","product_tag-additel-accumac-am-1710","product_tag-additel-am1710","product_tag-am-1710","product_tag-am1710","product_tag-edelstahl-temperaturfuehler","product_tag-europascal","product_tag-its-90","product_tag-kalibrierbad","product_tag-kalibrierlabor","product_tag-platin-widerstandsthermometer","product_tag-prt","product_tag-pt100-kalibrierung","product_tag-referenz-prt","product_tag-referenzfuehler","product_tag-referenzthermometer","product_tag-secondary-reference-prt","product_tag-sekundaernormal-temperatur","product_tag-temperaturfuehler","product_tag-temperaturkalibrierung","product_tag-temperaturmessung","product_tag-vergleichskalibrierung","pa_funktion-sekundaere-referenz-widerstandsthermometer","pa_genauigkeit-0-012c","pa_medium-widerstandsthermometer","pa_stabilitaet-0-007c","pa_temperaturbereich-40c-bis-160c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6985","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3423"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6985"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6985"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6985"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6985"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}