{"id":6987,"date":"2026-07-17T16:57:49","date_gmt":"2026-07-17T16:57:49","guid":{"rendered":"https:\/\/europascal.de\/product\/additel-accumac-am-1660\/"},"modified":"2026-10-14T10:52:24","modified_gmt":"2026-10-14T10:52:24","slug":"additel-accumac-am-1660","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/additel-accumac-am-1660\/","title":{"rendered":"Additel AccuMac AM 1660 Precise Industrial PRT"},"content":{"rendered":"<p>The <strong>Additel AccuMac AM 1660<\/strong> is a high-precision industrial platinum resistance thermometer (PRT) designed for accurate temperature measurement and calibration in laboratories, industrial facilities and demanding metrology applications.<\/p>\n<p>With a temperature range from <strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong>, an accuracy better than <strong>0.035 \u00b0C at 0 \u00b0C<\/strong> and excellent short-term stability of <strong>less than 0.01 \u00b0C<\/strong>, the Additel AccuMac AM 1660 provides reliable performance for precision temperature measurement.<\/p>\n<p>The thermometer combines a specially designed wire-wound platinum sensing element with a robust Inconel sheath. This construction offers excellent mechanical durability, resistance to thermal shock and long-term measurement stability.<\/p>\n<p>Each Additel AccuMac AM 1660 is supplied with an <strong>ISO\/IEC 17025 accredited calibration<\/strong>, making it particularly suitable for professional calibration laboratories and industrial quality assurance.<\/p>\n<p>The sensor is designed for applications requiring a reliable reference thermometer with excellent repeatability and low measurement drift.<\/p>\n<p>For professional temperature calibration equipment and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The Additel AccuMac AM 1660 combines high measurement accuracy with robust industrial construction.<\/p>\n<p>Its main advantages include:<\/p>\n<ul>\n<li>Wide temperature range from \u2212200 \u00b0C to +670 \u00b0C<\/li>\n<li>Accuracy better than 0.035 \u00b0C at 0 \u00b0C<\/li>\n<li>Short-term stability better than 0.01 \u00b0C<\/li>\n<li>Long-term drift below 0.03 \u00b0C under specified conditions<\/li>\n<li>Nominal resistance of 100 \u03a9 at 0 \u00b0C<\/li>\n<li>Temperature coefficient of 0.00385 \u03a9\/\u03a9\/\u00b0C<\/li>\n<li>High-quality wire-wound platinum sensing element<\/li>\n<li>Robust Inconel protective sheath<\/li>\n<li>Excellent resistance to mechanical shock<\/li>\n<li>Excellent resistance to thermal shock<\/li>\n<li>Low temperature hysteresis<\/li>\n<li>Four-wire resistance measurement<\/li>\n<li>Suitable for measurement currents of 0.5 mA and 1 mA<\/li>\n<li>Fast thermal response<\/li>\n<li>ISO\/IEC 17025 accredited calibration included<\/li>\n<li>Suitable for industrial and laboratory applications<\/li>\n<li>Compatible with precision resistance thermometer readouts<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Wide Temperature Range from \u2212200 \u00b0C to +670 \u00b0C<\/h2>\n<p>The <strong>Additel AccuMac AM 1660<\/strong> provides a temperature measurement range of:<\/p>\n<p><strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong><\/p>\n<p>This wide operating range makes the thermometer suitable for numerous industrial and laboratory applications.<\/p>\n<p>Typical measurement and calibration temperatures include:<\/p>\n<ul>\n<li>\u2212196 \u00b0C<\/li>\n<li>\u221280 \u00b0C<\/li>\n<li>\u221240 \u00b0C<\/li>\n<li>0 \u00b0C<\/li>\n<li>50 \u00b0C<\/li>\n<li>100 \u00b0C<\/li>\n<li>200 \u00b0C<\/li>\n<li>300 \u00b0C<\/li>\n<li>400 \u00b0C<\/li>\n<li>500 \u00b0C<\/li>\n<li>600 \u00b0C<\/li>\n<li>670 \u00b0C<\/li>\n<\/ul>\n<p>The thermometer can be used in temperature calibration baths, dry block calibrators and other suitable temperature sources.<\/p>\n<p>Its wide measurement range allows one reference thermometer to cover many calibration applications.<\/p>\n<p>For accurate measurements, sufficient immersion depth and appropriate thermal contact must be ensured.<\/p>\n<h2>High Measurement Accuracy<\/h2>\n<p>The Additel AccuMac AM 1660 provides excellent temperature measurement accuracy.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Accuracy: &lt;0.035 \u00b0C at 0 \u00b0C<\/strong><\/p>\n<p>This accuracy makes the thermometer suitable for precision temperature measurement and comparison calibration.<\/p>\n<p>The accuracy specification applies at the stated reference temperature and must not be interpreted as a constant accuracy across the entire operating range.<\/p>\n<p>For applications requiring the lowest possible measurement uncertainty, the individual calibration certificate should be used to determine the thermometer&#8217;s calibration corrections.<\/p>\n<p>The complete measurement uncertainty also depends on the connected resistance thermometer readout and the measurement conditions.<\/p>\n<h2>Excellent Short-Term Stability<\/h2>\n<p>The Additel AccuMac AM 1660 provides excellent short-term stability.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Short-term stability: &lt;0.01 \u00b0C<\/strong><\/p>\n<p>High short-term stability is essential for precision temperature measurements.<\/p>\n<p>It helps ensure repeatable results during calibration procedures and temperature comparison measurements.<\/p>\n<p>The thermometer is particularly suitable for applications requiring stable measurements over repeated temperature cycles.<\/p>\n<h2>Low Long-Term Drift<\/h2>\n<p>The Additel AccuMac AM 1660 is designed for excellent long-term measurement stability.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Long-term drift: &lt;0.03 \u00b0C<\/strong><\/p>\n<p>This value refers to the change measured at 0 \u00b0C after 100 hours of exposure to the maximum operating temperature.<\/p>\n<p>Actual long-term drift depends on operating conditions, handling and maintenance.<\/p>\n<p>Regular recalibration is recommended to monitor changes in thermometer characteristics.<\/p>\n<p>The individual calibration history can be used to determine an appropriate recalibration interval.<\/p>\n<h2>Wire-Wound Platinum Sensing Element<\/h2>\n<p>The Additel AccuMac AM 1660 uses a specially designed wire-wound platinum sensing element.<\/p>\n<p>Platinum resistance thermometers are widely used in precision temperature measurement because of their predictable resistance-temperature characteristics.<\/p>\n<p>The nominal resistance of the sensor is:<\/p>\n<p><strong>100 \u03a9 at 0 \u00b0C<\/strong><\/p>\n<p>The temperature coefficient is:<\/p>\n<p><strong>0.00385 \u03a9\/\u03a9\/\u00b0C<\/strong><\/p>\n<p>This corresponds to the commonly used industrial platinum resistance thermometer characteristic.<\/p>\n<p>The sensing element is designed to minimize contamination effects at elevated temperatures.<\/p>\n<p>A specially developed supporting structure helps protect the platinum wire against mechanical stress and thermal shock.<\/p>\n<p>This contributes to excellent stability and repeatability.<\/p>\n<h2>Robust Inconel Protective Sheath<\/h2>\n<p>The Additel AccuMac AM 1660 features a protective sheath manufactured from Inconel.<\/p>\n<p>Inconel is a nickel-based alloy known for its high-temperature strength and corrosion resistance.<\/p>\n<p>The sheath provides mechanical protection for the sensitive platinum measuring element.<\/p>\n<p>This makes the thermometer suitable for demanding industrial environments.<\/p>\n<p>The robust construction also helps protect the sensing element against mechanical shock and temperature cycling.<\/p>\n<h2>Excellent Thermal Shock Resistance<\/h2>\n<p>The Additel AccuMac AM 1660 is designed to withstand repeated temperature changes.<\/p>\n<p>The manufacturer specifies a thermal shock effect of:<\/p>\n<p><strong>&lt;0.007 \u00b0C<\/strong><\/p>\n<p>This value applies after ten temperature cycles between the minimum and maximum operating temperatures under the manufacturer&#8217;s defined test conditions.<\/p>\n<p>Excellent thermal shock resistance is particularly important when the thermometer is frequently transferred between different calibration temperatures.<\/p>\n<p>The robust sensor construction helps maintain stable measurement characteristics during repeated use.<\/p>\n<h2>Low Temperature Hysteresis<\/h2>\n<p>The Additel AccuMac AM 1660 provides low temperature hysteresis.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>Hysteresis: \u22640.01 \u00b0C<\/strong><\/p>\n<p>Temperature hysteresis describes differences in thermometer indication depending on the previous temperature history.<\/p>\n<p>Low hysteresis contributes to reliable and repeatable temperature measurements.<\/p>\n<p>This characteristic is particularly important during calibration procedures involving both increasing and decreasing temperature sequences.<\/p>\n<h2>Four-Wire Resistance Measurement<\/h2>\n<p>The Additel AccuMac AM 1660 uses a four-wire electrical connection.<\/p>\n<p>Four-wire resistance measurement minimizes the influence of lead resistance on the measurement result.<\/p>\n<p>This is particularly important for precision platinum resistance thermometers.<\/p>\n<p>The thermometer is equipped with four external copper leads insulated with PTFE.<\/p>\n<p>The cable length is approximately:<\/p>\n<p><strong>2 meters<\/strong><\/p>\n<p>The recommended measurement currents are:<\/p>\n<p><strong>0.5 mA or 1 mA<\/strong><\/p>\n<p>The appropriate measurement current should be selected according to the required measurement uncertainty and the characteristics of the connected readout.<\/p>\n<h2>Fast Thermal Response<\/h2>\n<p>The Additel AccuMac AM 1660 provides a fast thermal response.<\/p>\n<p>The manufacturer specifies a response time of:<\/p>\n<p><strong>5 seconds<\/strong><\/p>\n<p>This value describes the time required to reach 63% of a temperature step change in moving water at a flow velocity of 1 m\/s.<\/p>\n<p>Actual response times depend on the measurement medium, flow conditions, immersion depth and thermal contact.<\/p>\n<p>The fast response makes the thermometer suitable for applications requiring efficient temperature measurement.<\/p>\n<h2>Sensor Dimensions<\/h2>\n<p>The Additel AccuMac AM 1660 is available as the AM1660-12 configuration.<\/p>\n<p>The probe dimensions are:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Value<\/th>\n<\/tr>\n<tr>\n<td>Probe diameter<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<tr>\n<td>Probe length<\/td>\n<td>305 mm<\/td>\n<\/tr>\n<tr>\n<td>Sensing element length<\/td>\n<td>32 mm<\/td>\n<\/tr>\n<tr>\n<td>Sensing element position<\/td>\n<td>5 mm from the probe tip<\/td>\n<\/tr>\n<tr>\n<td>Handle diameter<\/td>\n<td>15 mm<\/td>\n<\/tr>\n<tr>\n<td>Handle length<\/td>\n<td>65 mm<\/td>\n<\/tr>\n<tr>\n<td>Cable length<\/td>\n<td>2 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The 305 mm probe length provides flexibility when measuring temperatures in calibration baths and dry block calibrators.<\/p>\n<p>The sensor must be immersed sufficiently to minimize heat conduction errors along the probe stem.<\/p>\n<p>The required immersion depth depends on the calibration temperature, measurement medium and required uncertainty.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Additel AccuMac AM 1660<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Additel<\/td>\n<\/tr>\n<tr>\n<td>Product series<\/td>\n<td>AccuMac<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>AM1660-12<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Precision Industrial PRT<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u2212200 \u00b0C to +670 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Nominal resistance at 0 \u00b0C<\/td>\n<td>100 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Temperature coefficient<\/td>\n<td>0.00385 \u03a9\/\u03a9\/\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy at 0 \u00b0C<\/td>\n<td>&lt;0.035 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Short-term stability<\/td>\n<td>&lt;0.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Long-term drift<\/td>\n<td>&lt;0.03 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Thermal shock effect<\/td>\n<td>&lt;0.007 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Hysteresis<\/td>\n<td>\u22640.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Measurement current<\/td>\n<td>0.5 mA or 1 mA<\/td>\n<\/tr>\n<tr>\n<td>Response time<\/td>\n<td>5 seconds<\/td>\n<\/tr>\n<tr>\n<td>Sensing element<\/td>\n<td>Wire-wound platinum<\/td>\n<\/tr>\n<tr>\n<td>Sensing element length<\/td>\n<td>32 mm<\/td>\n<\/tr>\n<tr>\n<td>Sensing element position<\/td>\n<td>5 mm from tip<\/td>\n<\/tr>\n<tr>\n<td>Sheath material<\/td>\n<td>Inconel<\/td>\n<\/tr>\n<tr>\n<td>Probe diameter<\/td>\n<td>6.35 mm<\/td>\n<\/tr>\n<tr>\n<td>Probe length<\/td>\n<td>305 mm<\/td>\n<\/tr>\n<tr>\n<td>Electrical connection<\/td>\n<td>Four-wire<\/td>\n<\/tr>\n<tr>\n<td>Cable length<\/td>\n<td>2 m<\/td>\n<\/tr>\n<tr>\n<td>Insulation resistance<\/td>\n<td>&gt;1000 M\u03a9 at room temperature<\/td>\n<\/tr>\n<tr>\n<td>Handle temperature range<\/td>\n<td>\u221250 \u00b0C to +180 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Calibration<\/td>\n<td>ISO\/IEC 17025 accredited calibration included<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Calibration with Precision Thermometer Readouts<\/h2>\n<p>The Additel AccuMac AM 1660 can be connected to compatible precision resistance thermometer readouts.<\/p>\n<p>For accurate temperature measurements, a readout with suitable resistance measurement accuracy and four-wire measurement capability is recommended.<\/p>\n<p>The thermometer can be used with compatible Additel reference thermometer readouts, including the Additel 282 and Additel 286.<\/p>\n<p>These instruments support professional temperature measurement and calibration applications.<\/p>\n<p>The measurement uncertainty of the complete system depends on the thermometer, the readout and the calibration conditions.<\/p>\n<p>For demanding applications, the thermometer&#8217;s individual calibration coefficients should be used whenever supported by the connected instrument.<\/p>\n<h2>Applications in Temperature Calibration Laboratories<\/h2>\n<p>The Additel AccuMac AM 1660 is particularly suitable for professional temperature calibration laboratories.<\/p>\n<p>Typical applications include comparison calibration of industrial resistance thermometers and verification of temperature calibration equipment.<\/p>\n<p>The thermometer can be used as a reference sensor in suitable temperature baths and dry block calibrators.<\/p>\n<p>Its wide temperature range allows calibration procedures to be performed across numerous temperature points.<\/p>\n<p>The accredited calibration certificate provides the traceability required for professional metrology applications.<\/p>\n<h2>Industrial Temperature Measurement<\/h2>\n<p>The Additel AccuMac AM 1660 is also suitable for industrial temperature measurement.<\/p>\n<p>Its robust Inconel sheath provides protection against demanding operating conditions.<\/p>\n<p>Typical applications include industrial heating systems, thermal processing, temperature monitoring and quality assurance.<\/p>\n<p>The thermometer is particularly useful when standard industrial temperature sensors do not provide sufficient measurement accuracy.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining accurate and traceable temperature measurements.<\/p>\n<p>europascal provides professional calibration services for temperature measuring instruments and calibration equipment.<\/p>\n<p>The Additel AccuMac AM 1660 is supplied with an ISO\/IEC 17025 accredited manufacturer calibration.<\/p>\n<p>For long-term measurement reliability, periodic recalibration is recommended.<\/p>\n<p>When the thermometer is used as a reference standard, the measurement uncertainty should consider:<\/p>\n<ul>\n<li>Calibration uncertainty of the thermometer<\/li>\n<li>Resistance measurement uncertainty of the readout<\/li>\n<li>Long-term drift<\/li>\n<li>Short-term stability<\/li>\n<li>Temperature hysteresis<\/li>\n<li>Self-heating effects<\/li>\n<li>Immersion depth<\/li>\n<li>Heat conduction along the probe stem<\/li>\n<li>Measurement repeatability<\/li>\n<\/ul>\n<p>These contributions should be evaluated according to the applicable calibration procedure.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Additel AccuMac AM 1660?<\/h2>\n<p>The Additel AccuMac AM 1660 combines precision temperature measurement with robust industrial construction.<\/p>\n<p>Its temperature range from \u2212200 \u00b0C to +670 \u00b0C makes it suitable for a wide variety of calibration and measurement applications.<\/p>\n<p>An accuracy better than 0.035 \u00b0C at 0 \u00b0C and excellent short-term stability provide reliable measurement performance.<\/p>\n<p>The specially designed wire-wound platinum sensing element helps minimize contamination effects and maintain stable resistance characteristics.<\/p>\n<p>The Inconel protective sheath provides excellent mechanical durability.<\/p>\n<p>Four-wire resistance measurement minimizes errors caused by lead resistance.<\/p>\n<p>The included ISO\/IEC 17025 accredited calibration provides metrological traceability.<\/p>\n<p>For calibration laboratories and industrial users requiring a reliable precision platinum resistance thermometer, the Additel AccuMac AM 1660 provides an excellent combination of accuracy, stability and durability.<\/p>\n<p>europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the Additel AccuMac AM 1660<\/h2>\n<p>The Additel AccuMac AM 1660 is suitable for numerous temperature measurement and calibration applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Precision temperature measurement<\/li>\n<li>Industrial temperature calibration<\/li>\n<li>Pt100 calibration<\/li>\n<li>RTD calibration<\/li>\n<li>Comparison calibration<\/li>\n<li>Reference temperature measurement<\/li>\n<li>Calibration bath measurements<\/li>\n<li>Dry block calibrator measurements<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Temperature metrology<\/li>\n<li>Thermal processing<\/li>\n<li>Laboratory temperature measurement<\/li>\n<li>Industrial maintenance<\/li>\n<li>Calibration laboratories<\/li>\n<li>Field calibration<\/li>\n<\/ul>\n<p>The combination of excellent accuracy, wide temperature range, low drift and robust construction makes the Additel AccuMac AM 1660 a professional solution for demanding temperature measurement applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/additel\/\">Find more Additel products at europascal.<\/a><\/p>\n<p>Manufacturer information for the Additel AccuMac AM 1660 can be found on the <a href=\"https:\/\/additel.com\/product-detail.html\/am1660-am1640-precision-industrial-prts\/\" target=\"_blank\" rel=\"noopener\">official Additel website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Additel-AccuMac-AM1660-AM1640-Precision-Indusrial-PRTs-20230625.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Additel AccuMac AM 1660<\/strong> is a high-precision industrial platinum resistance thermometer with a temperature range from <strong>\u2212200 \u00b0C to +670 \u00b0C<\/strong>. Featuring an accuracy better than <strong>0.035 \u00b0C at 0 \u00b0C<\/strong>, excellent stability and a robust Inconel sheath, it provides reliable performance for demanding temperature measurement and calibration applications. An <strong>ISO\/IEC 17025 accredited calibration<\/strong> is included.<\/p>\n","protected":false},"featured_media":3422,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[93,90],"product_cat":[58,53],"product_tag":[6514,6541,6542,6543,6544,6545,6546,3920,6508,5955,6547,4105,3922,6226,5956,5976,6548,5939,5027,5893,5979,4000,4113,4402],"class_list":["post-6987","product","type-product","status-publish","has-post-thumbnail","product_brand-accumac","product_brand-additel","product_cat-temperature-sensors","product_cat-temperature","product_tag-100-ohm-prt","product_tag-accumac-am-1660","product_tag-additel-accumac-am-1660","product_tag-additel-am1660","product_tag-am-1660","product_tag-am1640","product_tag-am1660","product_tag-europascal","product_tag-hochtemperatur-prt","product_tag-inconel-temperaturfuehler","product_tag-industrie-prt","product_tag-kalibrierbad","product_tag-kalibrierlabor","product_tag-platin-widerstandsthermometer","product_tag-praezisions-prt","product_tag-praezisionstemperaturfuehler","product_tag-precision-industrial-prt","product_tag-pt100","product_tag-pt100-kalibrierung","product_tag-referenzfuehler","product_tag-temperaturfuehler","product_tag-temperaturkalibrierung","product_tag-temperaturmessung","product_tag-vergleichskalibrierung","pa_genauigkeit-0035c","pa_medium-widerstandsthermometer","pa_stabilitaet-001c-2","pa_temperaturbereich-200c-bis-670c","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/6987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3422"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=6987"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=6987"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=6987"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=6987"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}