{"id":7004,"date":"2026-07-17T16:23:03","date_gmt":"2026-07-17T16:23:03","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-calibration-8846a\/"},"modified":"2026-10-14T11:31:15","modified_gmt":"2026-10-14T11:31:15","slug":"fluke-calibration-8846a","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-8846a\/","title":{"rendered":"Fluke Calibration 8846A Precise Digital Multimeter"},"content":{"rendered":"<p>The <strong>Fluke Calibration 8846A<\/strong> is a high-precision 6.5-digit digital multimeter designed for demanding electrical measurements in calibration laboratories, research facilities, development departments and automated test systems.<\/p>\n<p>With a DC voltage basic accuracy of <strong>0.0024%<\/strong>, a measurement resolution of 6.5 digits and a wide range of measurement functions, the Fluke Calibration 8846A provides outstanding performance for professional electrical measurement applications.<\/p>\n<p>The instrument combines the capabilities of a precision digital multimeter with advanced mathematical and graphical analysis functions.<\/p>\n<p>It measures DC voltage, AC voltage, DC current, AC current, resistance, frequency, period, capacitance and temperature using compatible platinum resistance thermometers.<\/p>\n<p>The Fluke Calibration 8846A also features a dual display, allowing two measurement parameters to be displayed simultaneously.<\/p>\n<p>Its integrated TrendPlot function, histogram display and statistical analysis capabilities make it particularly suitable for monitoring electrical signals and evaluating measurement stability.<\/p>\n<p>With RS-232, IEEE-488.2 and Ethernet interfaces, the instrument can be integrated into automated measurement and calibration systems.<\/p>\n<p>For professional electrical calibration equipment and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The Fluke Calibration 8846A combines excellent measurement accuracy with comprehensive functionality and convenient operation.<\/p>\n<p>Its main advantages include:<\/p>\n<ul>\n<li>High-precision 6.5-digit digital multimeter<\/li>\n<li>DC voltage basic accuracy of 0.0024%<\/li>\n<li>DC voltage measurement up to 1000 V<\/li>\n<li>AC voltage measurement up to 1000 V<\/li>\n<li>DC and AC current measurement up to 10 A<\/li>\n<li>Resistance measurement up to 1 G\u03a9<\/li>\n<li>Resistance resolution down to 10 \u00b5\u03a9<\/li>\n<li>DC current resolution down to 100 pA<\/li>\n<li>Two-wire and four-wire resistance measurement<\/li>\n<li>Special 2 \u00d7 4-wire resistance measurement function<\/li>\n<li>Frequency measurement up to 1 MHz<\/li>\n<li>Capacitance measurement up to 0.1 F<\/li>\n<li>Temperature measurement with Pt100 sensors<\/li>\n<li>Temperature range from \u2212200 \u00b0C to +600 \u00b0C<\/li>\n<li>Large dual graphical display<\/li>\n<li>TrendPlot function for measurement monitoring<\/li>\n<li>Histogram display<\/li>\n<li>Statistical measurement analysis<\/li>\n<li>Minimum and maximum value recording<\/li>\n<li>Limit comparison function<\/li>\n<li>dB and dBm calculations<\/li>\n<li>USB memory interface<\/li>\n<li>RS-232 communication<\/li>\n<li>IEEE-488.2 interface<\/li>\n<li>Ethernet communication<\/li>\n<li>SCPI programming support<\/li>\n<li>Emulation of Fluke 45 and Agilent 34401A<\/li>\n<li>Suitable for automated calibration systems<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p>The <strong>Fluke Calibration 8846A<\/strong> is designed for applications requiring high measurement accuracy, excellent resolution and reliable long-term performance.<\/p>\n<p>Typical applications include electrical calibration laboratories, research and development, industrial quality assurance and automated production testing.<\/p>\n<p>The instrument can be used as a precision measuring device for checking electrical signal sources, calibrators, transmitters and other electrical equipment.<\/p>\n<p>Its high resolution makes it possible to detect small changes in voltage, current and resistance.<\/p>\n<p>The graphical analysis functions also allow users to observe measurement stability and identify variations over time.<\/p>\n<p>For calibration laboratories working according to ISO\/IEC 17025, the Fluke Calibration 8846A provides a versatile measurement platform.<\/p>\n<p>The suitability of the instrument as a reference standard depends on the required measurement uncertainty and the applicable calibration procedure.<\/p>\n<h2>High-Precision DC Voltage Measurement<\/h2>\n<p>The Fluke Calibration 8846A provides highly accurate DC voltage measurements.<\/p>\n<p>The manufacturer specifies a basic DC voltage accuracy of:<\/p>\n<p><strong>0.0024% of reading + 0.0005% of range<\/strong><\/p>\n<p>This specification applies to the 10 V measurement range under the defined one-year reference conditions.<\/p>\n<p>The instrument provides DC voltage measurement ranges from:<\/p>\n<p><strong>100 mV to 1000 V<\/strong><\/p>\n<p>The maximum display resolution is:<\/p>\n<p><strong>100 nV<\/strong><\/p>\n<p>This makes the Fluke Calibration 8846A suitable for measuring stable DC voltage sources and evaluating precision electronic circuits.<\/p>\n<p>Typical applications include voltage reference measurements, calibration of electrical signal sources and verification of industrial measurement equipment.<\/p>\n<p>The actual measurement accuracy depends on the selected measurement range, measurement conditions and calibration interval.<\/p>\n<h2>AC Voltage Measurement<\/h2>\n<p>The Fluke Calibration 8846A also provides accurate AC voltage measurement.<\/p>\n<p>The available measurement ranges extend from:<\/p>\n<p><strong>100 mV to 1000 V<\/strong><\/p>\n<p>The manufacturer specifies a basic AC voltage accuracy of:<\/p>\n<p><strong>0.06% of reading + 0.03% of range<\/strong><\/p>\n<p>This specification applies under defined frequency and operating conditions.<\/p>\n<p>The instrument is suitable for measuring sinusoidal AC voltages in laboratory and industrial applications.<\/p>\n<p>For accurate AC measurements, the signal frequency, waveform and applicable measurement range must be considered.<\/p>\n<p>The Fluke Calibration 8846A provides true RMS measurement capability for suitable AC signals.<\/p>\n<h2>DC Current Measurement<\/h2>\n<p>The Fluke Calibration 8846A supports precise DC current measurement.<\/p>\n<p>The measurement range extends from:<\/p>\n<p><strong>100 \u00b5A to 10 A<\/strong><\/p>\n<p>The maximum current resolution is:<\/p>\n<p><strong>100 pA<\/strong><\/p>\n<p>The manufacturer specifies a basic DC current accuracy of:<\/p>\n<p><strong>0.050% of reading + 0.005% of range<\/strong><\/p>\n<p>The high resolution allows small current changes to be detected.<\/p>\n<p>This is particularly useful when measuring electronic circuits, current sources and industrial process signals.<\/p>\n<p>The instrument can also be used to measure 4\u201320 mA signals.<\/p>\n<p>For accurate current measurements, the burden voltage and the selected current range must be considered.<\/p>\n<h2>AC Current Measurement<\/h2>\n<p>The Fluke Calibration 8846A provides AC current measurement up to:<\/p>\n<p><strong>10 A<\/strong><\/p>\n<p>The available AC current ranges begin at:<\/p>\n<p><strong>100 mA<\/strong><\/p>\n<p>The manufacturer specifies a basic AC current accuracy of:<\/p>\n<p><strong>0.10% of reading + 0.04% of range<\/strong><\/p>\n<p>This specification applies under defined operating conditions.<\/p>\n<p>The instrument can be used for testing electrical circuits, current sources and industrial measurement systems.<\/p>\n<p>The applicable accuracy depends on signal frequency and measurement range.<\/p>\n<h2>Resistance Measurement up to 1 G\u03a9<\/h2>\n<p>The Fluke Calibration 8846A offers a particularly wide resistance measurement range.<\/p>\n<p>The instrument measures resistance from:<\/p>\n<p><strong>10 \u03a9 to 1 G\u03a9<\/strong><\/p>\n<p>The maximum resolution is:<\/p>\n<p><strong>10 \u00b5\u03a9<\/strong><\/p>\n<p>The manufacturer specifies a basic resistance accuracy of:<\/p>\n<p><strong>0.010% of reading + 0.001% of range<\/strong><\/p>\n<p>The wide resistance range makes the instrument suitable for numerous electrical measurement applications.<\/p>\n<p>Typical applications include precision resistor measurements, resistance sensor testing and electrical component verification.<\/p>\n<p>For low-resistance measurements, four-wire measurement techniques help reduce errors caused by test lead resistance.<\/p>\n<p>For high-resistance measurements, leakage currents, insulation resistance and environmental conditions become increasingly important.<\/p>\n<h2>Special 2 \u00d7 4-Wire Resistance Measurement<\/h2>\n<p>The Fluke Calibration 8846A features a special 2 \u00d7 4-wire resistance measurement function.<\/p>\n<p>This function simplifies four-wire resistance measurements.<\/p>\n<p>Traditional four-wire measurements require separate connections for current supply and voltage measurement.<\/p>\n<p>The Fluke 2 \u00d7 4-wire technique allows compatible measurement leads to combine the necessary connections in a more convenient configuration.<\/p>\n<p>This helps reduce connection errors and simplifies repetitive resistance measurements.<\/p>\n<p>The function is particularly useful when testing precision resistors and resistance-based sensors.<\/p>\n<p>For demanding low-resistance measurements, suitable test leads and correct connection techniques are essential.<\/p>\n<h2>Frequency and Period Measurement<\/h2>\n<p>The Fluke Calibration 8846A supports frequency and period measurement.<\/p>\n<p>The frequency measurement range extends from:<\/p>\n<p><strong>3 Hz to 1 MHz<\/strong><\/p>\n<p>The maximum frequency resolution is:<\/p>\n<p><strong>1 \u00b5Hz<\/strong><\/p>\n<p>The manufacturer specifies a basic frequency accuracy of:<\/p>\n<p><strong>0.01%<\/strong><\/p>\n<p>This makes the instrument suitable for checking signal generators, electronic circuits and industrial frequency signals.<\/p>\n<p>Period measurements provide an alternative representation of the same signal.<\/p>\n<p>For periodic signals, the relationship between frequency and period is:<\/p>\n<p><strong>T = 1 \/ f<\/strong><\/p>\n<p>where T is the period and f is the frequency.<\/p>\n<p>The frequency measurement function is useful for laboratory measurements and automated test applications.<\/p>\n<h2>Capacitance Measurement<\/h2>\n<p>The Fluke Calibration 8846A includes an integrated capacitance measurement function.<\/p>\n<p>The capacitance measurement range extends from:<\/p>\n<p><strong>1 nF to 0.1 F<\/strong><\/p>\n<p>The maximum resolution is:<\/p>\n<p><strong>1 pF<\/strong><\/p>\n<p>The manufacturer specifies a basic capacitance accuracy of:<\/p>\n<p><strong>1%<\/strong><\/p>\n<p>This function allows capacitors and capacitive components to be checked without requiring a separate capacitance meter.<\/p>\n<p>Capacitance measurement is particularly useful for electronics development, maintenance and quality assurance.<\/p>\n<p>The measurement accuracy depends on the selected range and measurement conditions.<\/p>\n<h2>Temperature Measurement with Pt100 Sensors<\/h2>\n<p>The Fluke Calibration 8846A supports temperature measurement using compatible platinum resistance thermometers.<\/p>\n<p>The supported temperature sensor type is:<\/p>\n<p><strong>Pt100<\/strong><\/p>\n<p>The temperature measurement range extends from:<\/p>\n<p><strong>\u2212200 \u00b0C to +600 \u00b0C<\/strong><\/p>\n<p>The maximum temperature resolution is:<\/p>\n<p><strong>0.01 \u00b0C<\/strong><\/p>\n<p>The manufacturer specifies an instrument temperature accuracy of:<\/p>\n<p><strong>0.06 \u00b0C<\/strong><\/p>\n<p>This allows the Fluke Calibration 8846A to be used for temperature monitoring and suitable temperature measurement applications.<\/p>\n<p>The instrument measures the electrical resistance of the connected Pt100 sensor and converts it into a temperature value.<\/p>\n<p>The actual measurement uncertainty of the complete temperature measurement system depends on the sensor, its calibration and the measurement conditions.<\/p>\n<p>The specified instrument accuracy must not be confused with the total uncertainty of the connected temperature probe.<\/p>\n<h2>Dual Graphical Display<\/h2>\n<p>The Fluke Calibration 8846A features a large graphical dual display.<\/p>\n<p>The dual display allows two measurement parameters to be shown simultaneously.<\/p>\n<p>For example, users can monitor voltage and frequency or other compatible measurement combinations.<\/p>\n<p>This reduces the need to switch between measurement functions.<\/p>\n<p>The graphical display also supports advanced analysis functions.<\/p>\n<p>These include TrendPlot, histograms and statistical evaluations.<\/p>\n<p>The display is particularly useful when observing measurement changes over time.<\/p>\n<h2>TrendPlot Function<\/h2>\n<p>The integrated TrendPlot function provides a graphical representation of measurement values over time.<\/p>\n<p>This allows users to monitor changes in electrical signals.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Monitoring voltage stability<\/li>\n<li>Observing current variations<\/li>\n<li>Detecting intermittent measurement changes<\/li>\n<li>Evaluating long-term measurement behavior<\/li>\n<li>Investigating electrical signal drift<\/li>\n<\/ul>\n<p>TrendPlot provides a convenient alternative to manually recording measurement values.<\/p>\n<p>It is particularly useful for troubleshooting and laboratory measurements.<\/p>\n<h2>Histogram Function<\/h2>\n<p>The Fluke Calibration 8846A includes a histogram display.<\/p>\n<p>A histogram shows the distribution of measured values.<\/p>\n<p>This helps users evaluate the variation of repeated measurements.<\/p>\n<p>For example, a histogram can reveal whether measured values are concentrated around a central value or distributed over a wider range.<\/p>\n<p>This function is useful when investigating measurement noise and repeatability.<\/p>\n<p>The histogram display supports statistical evaluation directly on the instrument.<\/p>\n<h2>Statistical Measurement Functions<\/h2>\n<p>The Fluke Calibration 8846A provides several mathematical and statistical functions.<\/p>\n<p>These include:<\/p>\n<ul>\n<li>Minimum value<\/li>\n<li>Maximum value<\/li>\n<li>Average value<\/li>\n<li>Standard deviation<\/li>\n<li>Null function<\/li>\n<li>dB calculations<\/li>\n<li>dBm calculations<\/li>\n<\/ul>\n<p>These functions simplify the evaluation of measurement results.<\/p>\n<p>Minimum and maximum recording is particularly useful when investigating fluctuations.<\/p>\n<p>Average and standard deviation functions help characterize repeated measurements.<\/p>\n<p>The dB and dBm functions support measurements involving logarithmic signal representations.<\/p>\n<h2>Limit Comparison Function<\/h2>\n<p>The Fluke Calibration 8846A features an integrated limit comparison function.<\/p>\n<p>Users can define upper and lower measurement limits.<\/p>\n<p>The instrument compares the measured value with these limits.<\/p>\n<p>This function is particularly useful in production testing and quality assurance.<\/p>\n<p>It allows electrical components and devices to be checked against predefined acceptance criteria.<\/p>\n<p>Limit comparison can also be integrated into automated test procedures.<\/p>\n<h2>USB Memory Interface<\/h2>\n<p>The Fluke Calibration 8846A includes a USB memory interface.<\/p>\n<p>This function allows measurement data to be stored using compatible USB memory devices.<\/p>\n<p>The USB memory interface is a specific feature of the 8846A model.<\/p>\n<p>It is not available on the Fluke 8845A.<\/p>\n<p>The integrated real-time clock supports time-related measurement documentation.<\/p>\n<p>These features are useful for laboratory measurements and data recording applications.<\/p>\n<h2>RS-232, IEEE-488.2 and Ethernet Communication<\/h2>\n<p>The Fluke Calibration 8846A provides multiple communication interfaces.<\/p>\n<p>These include:<\/p>\n<ul>\n<li>RS-232<\/li>\n<li>IEEE-488.2<\/li>\n<li>Ethernet<\/li>\n<\/ul>\n<p>The instrument supports SCPI commands for remote control.<\/p>\n<p>This allows integration into automated measurement systems.<\/p>\n<p>The Fluke Calibration 8846A also supports emulation of the Fluke 45 and Agilent 34401A.<\/p>\n<p>This can simplify the replacement of older instruments in existing automated test systems.<\/p>\n<p>The available communication interfaces make the instrument suitable for laboratory automation and production testing.<\/p>\n<h2>Technical Highlights<\/h2>\n<p>The Fluke Calibration 8846A provides the following important specifications:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 8846A<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>8846A<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Precision Digital Multimeter<\/td>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>6.5 digits<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>Dual VFD dot-matrix display<\/td>\n<\/tr>\n<tr>\n<td>DC voltage range<\/td>\n<td>100 mV to 1000 V<\/td>\n<\/tr>\n<tr>\n<td>DC voltage resolution<\/td>\n<td>100 nV<\/td>\n<\/tr>\n<tr>\n<td>DC voltage basic accuracy<\/td>\n<td>0.0024% + 0.0005% of range<\/td>\n<\/tr>\n<tr>\n<td>AC voltage range<\/td>\n<td>100 mV to 1000 V<\/td>\n<\/tr>\n<tr>\n<td>AC voltage basic accuracy<\/td>\n<td>0.06% + 0.03% of range<\/td>\n<\/tr>\n<tr>\n<td>DC current range<\/td>\n<td>100 \u00b5A to 10 A<\/td>\n<\/tr>\n<tr>\n<td>DC current resolution<\/td>\n<td>100 pA<\/td>\n<\/tr>\n<tr>\n<td>DC current basic accuracy<\/td>\n<td>0.050% + 0.005% of range<\/td>\n<\/tr>\n<tr>\n<td>AC current range<\/td>\n<td>100 mA to 10 A<\/td>\n<\/tr>\n<tr>\n<td>AC current basic accuracy<\/td>\n<td>0.10% + 0.04% of range<\/td>\n<\/tr>\n<tr>\n<td>Resistance range<\/td>\n<td>10 \u03a9 to 1 G\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resistance resolution<\/td>\n<td>10 \u00b5\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resistance basic accuracy<\/td>\n<td>0.010% + 0.001% of range<\/td>\n<\/tr>\n<tr>\n<td>Resistance measurement<\/td>\n<td>2-wire, 4-wire, 2 \u00d7 4-wire<\/td>\n<\/tr>\n<tr>\n<td>Frequency range<\/td>\n<td>3 Hz to 1 MHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency resolution<\/td>\n<td>1 \u00b5Hz<\/td>\n<\/tr>\n<tr>\n<td>Frequency basic accuracy<\/td>\n<td>0.01%<\/td>\n<\/tr>\n<tr>\n<td>Capacitance range<\/td>\n<td>1 nF to 0.1 F<\/td>\n<\/tr>\n<tr>\n<td>Capacitance resolution<\/td>\n<td>1 pF<\/td>\n<\/tr>\n<tr>\n<td>Capacitance basic accuracy<\/td>\n<td>1%<\/td>\n<\/tr>\n<tr>\n<td>Temperature sensor<\/td>\n<td>Pt100<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>\u2212200 \u00b0C to +600 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Temperature resolution<\/td>\n<td>0.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Instrument temperature accuracy<\/td>\n<td>0.06 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>TrendPlot<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Histogram<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Statistical functions<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Limit comparison<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>USB memory interface<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Real-time clock<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>RS-232<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>IEEE-488.2<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Ethernet<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>SCPI programming<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Agilent 34401A emulation<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Fluke 45 emulation<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>88 \u00d7 217 \u00d7 297 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approximately 3.6 kg<\/td>\n<\/tr>\n<tr>\n<td>Safety category<\/td>\n<td>CAT I 1000 V, CAT II 600 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The stated basic accuracy values apply to the manufacturer&#8217;s specified measurement ranges and reference conditions.<\/p>\n<p>For accurate uncertainty calculations, the complete range-dependent specifications must be considered.<\/p>\n<h2>Fluke Calibration 8846A Compared with 8845A<\/h2>\n<p>The Fluke Calibration 8846A and 8845A are both precision digital multimeters with 6.5-digit resolution.<\/p>\n<p>However, the 8846A offers additional measurement functions and improved specifications.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>Fluke Calibration 8846A<\/th>\n<th>Fluke Calibration 8845A<\/th>\n<\/tr>\n<tr>\n<td>Display resolution<\/td>\n<td>6.5 digits<\/td>\n<td>6.5 digits<\/td>\n<\/tr>\n<tr>\n<td>DC voltage basic accuracy<\/td>\n<td>0.0024%<\/td>\n<td>0.0035%<\/td>\n<\/tr>\n<tr>\n<td>DC voltage maximum<\/td>\n<td>1000 V<\/td>\n<td>1000 V<\/td>\n<\/tr>\n<tr>\n<td>AC voltage maximum<\/td>\n<td>1000 V<\/td>\n<td>750 V<\/td>\n<\/tr>\n<tr>\n<td>Resistance maximum<\/td>\n<td>1 G\u03a9<\/td>\n<td>100 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Frequency maximum<\/td>\n<td>1 MHz<\/td>\n<td>300 kHz<\/td>\n<\/tr>\n<tr>\n<td>Capacitance measurement<\/td>\n<td>Yes<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>Pt100 temperature measurement<\/td>\n<td>Yes<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>USB memory interface<\/td>\n<td>Yes<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>Real-time clock<\/td>\n<td>Yes<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>TrendPlot<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Histogram<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Ethernet<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The Fluke Calibration 8846A is particularly suitable for users requiring additional measurement capabilities and improved DC voltage accuracy.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining accurate and traceable electrical measurements.<\/p>\n<p>europascal provides professional calibration services for electrical measuring instruments and calibration equipment.<\/p>\n<p>When the Fluke Calibration 8846A is used as a reference measuring instrument, its measurement uncertainty must be evaluated according to the selected measurement function and range.<\/p>\n<p>Relevant uncertainty contributions may include:<\/p>\n<ul>\n<li>Calibration uncertainty<\/li>\n<li>Instrument accuracy specifications<\/li>\n<li>Long-term drift<\/li>\n<li>Temperature coefficients<\/li>\n<li>Measurement resolution<\/li>\n<li>Measurement repeatability<\/li>\n<li>Input impedance<\/li>\n<li>Lead resistance<\/li>\n<li>Thermoelectric voltages<\/li>\n<li>AC frequency response<\/li>\n<li>Measurement loading effects<\/li>\n<\/ul>\n<p>The uncertainty evaluation should follow the applicable calibration procedure and relevant metrological guidelines.<\/p>\n<p>For professional electrical calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Fluke Calibration 8846A?<\/h2>\n<p>The Fluke Calibration 8846A combines excellent electrical measurement accuracy with comprehensive measurement functionality.<\/p>\n<p>Its 6.5-digit resolution and DC voltage basic accuracy of 0.0024% make it suitable for demanding laboratory and industrial applications.<\/p>\n<p>The wide measurement ranges cover voltage, current, resistance, frequency, capacitance and temperature.<\/p>\n<p>Advanced functions such as TrendPlot, histograms and statistical analysis allow users to evaluate measurement behavior directly on the instrument.<\/p>\n<p>The special 2 \u00d7 4-wire resistance measurement function simplifies precision resistance measurements.<\/p>\n<p>The dual graphical display provides convenient access to measurement information.<\/p>\n<p>RS-232, IEEE-488.2 and Ethernet interfaces support integration into automated measurement systems.<\/p>\n<p>The USB memory interface and integrated real-time clock provide additional flexibility for data recording.<\/p>\n<p>For calibration laboratories, research facilities, development departments and industrial users requiring a high-performance precision multimeter, the Fluke Calibration 8846A provides an excellent combination of accuracy, versatility and efficiency.<\/p>\n<p>europascal supports customers with professional electrical calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the Fluke Calibration 8846A<\/h2>\n<p>The Fluke Calibration 8846A is suitable for numerous professional electrical measurement applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Electrical calibration laboratories<\/li>\n<li>Precision DC voltage measurement<\/li>\n<li>AC voltage measurement<\/li>\n<li>DC current measurement<\/li>\n<li>AC current measurement<\/li>\n<li>Precision resistance measurement<\/li>\n<li>Four-wire resistance measurement<\/li>\n<li>Frequency measurement<\/li>\n<li>Period measurement<\/li>\n<li>Capacitance measurement<\/li>\n<li>Pt100 temperature measurement<\/li>\n<li>Electrical signal monitoring<\/li>\n<li>Measurement stability analysis<\/li>\n<li>Automated production testing<\/li>\n<li>Research and development<\/li>\n<li>Electronic component testing<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Electrical metrology<\/li>\n<li>Reference measurements<\/li>\n<li>Calibration of electrical signal sources<\/li>\n<li>Automated measurement systems<\/li>\n<li>Preventive maintenance<\/li>\n<\/ul>\n<p>The combination of high accuracy, comprehensive measurement functions, advanced graphical analysis and flexible communication interfaces makes the Fluke Calibration 8846A a professional solution for demanding electrical measurement and calibration applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Find more Fluke Calibration products here.<\/a><\/p>\n<p>Manufacturer information for the Fluke Calibration 8846A can be found on the <a href=\"https:\/\/www.fluke.com\/de-ch\/produkt\/hochgenaue-messungen\/tisch-und-systemmessgeraete\/fluke-8845a-8846a\" target=\"_blank\" rel=\"noopener\">official Fluke website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-8845A-8846A-6.5-Digit-Precision-Multimeter.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 8846A<\/strong> is a high-precision <strong>6.5-digit digital multimeter<\/strong> with DC voltage accuracy down to <strong>0.0024%<\/strong>.<\/p>\n<p>It measures voltage, current, resistance up to <strong>1 G\u03a9<\/strong>, frequency, capacitance and Pt100 temperature. Featuring a dual graphical display, TrendPlot, USB memory and multiple communication interfaces, it is ideal for calibration laboratories, research and automated test systems.<\/p>\n","protected":false},"featured_media":7006,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[1211],"product_tag":[6599,6600,4765,6196,4766,3918,6601,6602,6603,4769,4770,4850,3922,6604,4772,4773,6605,6606,4776,4113,4777,4778,4779],"class_list":["post-7004","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-obsolete","product_tag-1-g-widerstand","product_tag-100-pa-stromaufloesung","product_tag-5-stelliges-multimeter","product_tag-6196","product_tag-digitalmultimeter","product_tag-elektrische-kalibrierung","product_tag-ethernet-multimeter","product_tag-fluke-8846a","product_tag-fluke-calibration-8846a","product_tag-frequenzmessung","product_tag-gleichspannung-messen","product_tag-gpib-multimeter","product_tag-kalibrierlabor","product_tag-kapazitaetsmessung","product_tag-labormultimeter","product_tag-praezisionsmultimeter","product_tag-pt100-messen","product_tag-scpi-multimeter","product_tag-systemmultimeter","product_tag-temperaturmessung","product_tag-tischmultimeter","product_tag-vierleitermessung","product_tag-widerstand-messen","pa_bauart-tischgeraet","pa_hart-kommunikation-nein","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/7004","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/7006"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=7004"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=7004"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=7004"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=7004"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}