{"id":7010,"date":"2026-07-17T16:22:51","date_gmt":"2026-07-17T16:22:51","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-787b\/"},"modified":"2026-10-14T11:37:51","modified_gmt":"2026-10-14T11:37:51","slug":"fluke-787b","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-787b\/","title":{"rendered":"Fluke 787B Versatile ProcessMeter"},"content":{"rendered":"<p>The <strong>Fluke 787B<\/strong> is a versatile ProcessMeter that combines a professional True-RMS digital multimeter with a precision mA loop calibrator in a single portable instrument.<\/p>\n<p>Designed for industrial maintenance, process instrumentation and electrical troubleshooting, the Fluke 787B allows technicians to measure, source and simulate current signals while providing the essential measurement functions of a digital multimeter.<\/p>\n<p>With a DC voltage measurement range up to <strong>1000 V<\/strong>, current measurement up to <strong>30 mA<\/strong>, resistance measurement up to <strong>40 M\u03a9<\/strong> and frequency measurement up to <strong>20 kHz<\/strong>, the instrument provides extensive functionality for demanding industrial applications.<\/p>\n<p>The integrated mA loop calibrator supports current sourcing and simulation from <strong>0 to 20 mA or 4 to 20 mA<\/strong>, with an accuracy of <strong>0.05% of span<\/strong>.<\/p>\n<p>The Fluke 787B also offers a high safety rating of <strong>CAT III 1000 V and CAT IV 600 V<\/strong>, making it suitable for professional electrical measurements in industrial environments.<\/p>\n<p>Its compact construction, backlit display and battery operation make it ideal for technicians who need reliable measurement and calibration capabilities directly in the field.<\/p>\n<p>europascal supports customers with professional calibration equipment, technical advice and reliable metrological services.<\/p>\n<p>For traceable calibration and regular verification of electrical measuring instruments, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/?utm_source=chatgpt.com\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The Fluke 787B combines the functionality of two professional instruments in one compact device.<\/p>\n<p>Key advantages include:<\/p>\n<ul>\n<li>Digital multimeter and mA loop calibrator in one instrument<\/li>\n<li>Measurement, sourcing and simulation of 4\u201320 mA signals<\/li>\n<li>DC voltage measurement up to 1000 V<\/li>\n<li>True-RMS AC voltage measurement up to 1000 V<\/li>\n<li>DC current measurement up to 30 mA<\/li>\n<li>Resistance measurement up to 40 M\u03a9<\/li>\n<li>Frequency measurement up to 20 kHz<\/li>\n<li>Current output accuracy of 0.05% of span<\/li>\n<li>Current measurement resolution of 0.001 mA<\/li>\n<li>Manual and automatic current stepping<\/li>\n<li>Automatic slow and fast ramp functions<\/li>\n<li>Simultaneous display of mA and percentage of span<\/li>\n<li>True-RMS measurement technology<\/li>\n<li>Diode and continuity testing<\/li>\n<li>Min\/Max\/Average measurement functions<\/li>\n<li>Hold and relative measurement functions<\/li>\n<li>Backlit display for improved readability<\/li>\n<li>CAT III 1000 V and CAT IV 600 V safety ratings<\/li>\n<li>Fluke Connect compatibility with optional IR3000FC module<\/li>\n<li>Portable construction weighing approximately 600 g<\/li>\n<li>Battery operation using four AA batteries<\/li>\n<li>Suitable for industrial maintenance and calibration<\/li>\n<\/ul>\n<h2>Ideal for Industrial Process Calibration<\/h2>\n<p>The Fluke 787B is particularly suitable for technicians working with industrial measurement and control systems.<\/p>\n<p>Many industrial processes use standardized current signals to transmit measurement values between sensors, transmitters, controllers and automation systems.<\/p>\n<p>One of the most common signal standards is:<\/p>\n<p><strong>4\u201320 mA<\/strong><\/p>\n<p>The Fluke 787B allows technicians to check these signals directly at the installation site.<\/p>\n<p>The instrument can measure the current flowing through a process loop or generate a defined current signal to test connected equipment.<\/p>\n<p>This makes it useful for commissioning, troubleshooting, maintenance and routine calibration.<\/p>\n<p>Typical applications include checking temperature transmitters, pressure transmitters, flow transmitters, level transmitters and process control systems.<\/p>\n<h2>4\u201320 mA Current Measurement<\/h2>\n<p>The Fluke 787B provides precise DC current measurement for industrial process signals.<\/p>\n<p>The manufacturer specifies a current measurement range of:<\/p>\n<p><strong>0 to 30.000 mA<\/strong><\/p>\n<p>The measurement resolution is:<\/p>\n<p><strong>0.001 mA<\/strong><\/p>\n<p>The best specified accuracy is:<\/p>\n<p><strong>\u00b1(0.05% of reading + 2 counts)<\/strong><\/p>\n<p>This resolution allows small changes in process current to be detected.<\/p>\n<p>For example, a current of 4 mA typically represents the lower range value of a process transmitter, while 20 mA represents the upper range value.<\/p>\n<p>The Fluke 787B can display the measured current and the corresponding percentage of the configured 4\u201320 mA span.<\/p>\n<p>This simplifies comparisons between the measured process signal and the values displayed by a controller.<\/p>\n<h2>Precision mA Current Source<\/h2>\n<p>The Fluke 787B can generate precise DC current signals.<\/p>\n<p>The available output ranges are:<\/p>\n<p><strong>0 to 20 mA<\/strong><\/p>\n<p>or:<\/p>\n<p><strong>4 to 20 mA<\/strong><\/p>\n<p>The output range can be selected when the instrument is switched on.<\/p>\n<p>The maximum output current is:<\/p>\n<p><strong>24 mA<\/strong><\/p>\n<p>The manufacturer specifies a current sourcing accuracy of:<\/p>\n<p><strong>0.05% of span<\/strong><\/p>\n<p>The current output provides a compliance voltage of up to 24 V.<\/p>\n<p>At an output current of 20 mA, the instrument can drive a load of up to 1200 \u03a9.<\/p>\n<p>This makes the Fluke 787B suitable for testing analog inputs of programmable logic controllers, process indicators and industrial control systems.<\/p>\n<p>A defined current signal can be generated and compared with the value indicated by the connected equipment.<\/p>\n<h2>Current Simulation for Process Loops<\/h2>\n<p>In addition to current sourcing, the Fluke 787B supports current simulation.<\/p>\n<p>Current simulation is useful when an external loop power supply is already available.<\/p>\n<p>The Fluke 787B controls the current flowing through the externally powered loop.<\/p>\n<p>The manufacturer specifies an external loop supply voltage of:<\/p>\n<p><strong>15 V to 48 V DC<\/strong><\/p>\n<p>The simulation function supports current values up to 24 mA.<\/p>\n<p>The specified accuracy is:<\/p>\n<p><strong>0.05% of span<\/strong><\/p>\n<p>This function is particularly useful when testing process control systems without connecting the original transmitter.<\/p>\n<p><strong>Important:<\/strong> The Fluke 787B does not provide the separate integrated 24 V loop power supply available on the Fluke 789. Its current sourcing function is nevertheless capable of driving a compatible load.<\/p>\n<h2>Automatic Current Ramping<\/h2>\n<p>The Fluke 787B provides automatic current ramping functions.<\/p>\n<p>These functions allow the output current to change automatically over a defined range.<\/p>\n<p>Available modes include:<\/p>\n<ul>\n<li>Slow ramp<\/li>\n<li>Fast ramp<\/li>\n<li>Automatic 25% steps<\/li>\n<\/ul>\n<p>Automatic ramping is particularly useful for checking the response of control systems and process indicators.<\/p>\n<p>For example, a 4\u201320 mA signal can be varied automatically while observing the response of a connected display or controller.<\/p>\n<p>This allows technicians to identify incorrect scaling, unstable indications or signal processing problems.<\/p>\n<h2>Manual Current Stepping<\/h2>\n<p>The Fluke 787B also supports manual current adjustment.<\/p>\n<p>Available functions include coarse adjustment, fine adjustment, 25% steps and 100% steps.<\/p>\n<p>For a standard 4\u201320 mA signal, typical test points are:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Percentage<\/th>\n<th>Current<\/th>\n<\/tr>\n<tr>\n<td>0%<\/td>\n<td>4 mA<\/td>\n<\/tr>\n<tr>\n<td>25%<\/td>\n<td>8 mA<\/td>\n<\/tr>\n<tr>\n<td>50%<\/td>\n<td>12 mA<\/td>\n<\/tr>\n<tr>\n<td>75%<\/td>\n<td>16 mA<\/td>\n<\/tr>\n<tr>\n<td>100%<\/td>\n<td>20 mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These test points are commonly used for checking the linearity and scaling of industrial process instruments.<\/p>\n<p>Manual stepping allows technicians to select individual test points without repeatedly entering numerical values.<\/p>\n<h2>True-RMS Digital Multimeter<\/h2>\n<p>The Fluke 787B incorporates the functionality of a professional True-RMS digital multimeter.<\/p>\n<p>True-RMS measurement technology allows the instrument to determine the effective value of AC signals, including suitable non-sinusoidal waveforms within the specified measurement conditions.<\/p>\n<p>This is particularly important in industrial environments where electrical signals may be distorted.<\/p>\n<p>The instrument supports AC and DC voltage measurement, AC and DC current measurement, resistance measurement and frequency measurement.<\/p>\n<p>Additional functions include diode testing and continuity testing.<\/p>\n<p>This combination makes the Fluke 787B suitable for both electrical troubleshooting and process signal calibration.<\/p>\n<h2>DC Voltage Measurement up to 1000 V<\/h2>\n<p>The Fluke 787B provides DC voltage measurement up to:<\/p>\n<p><strong>1000 V<\/strong><\/p>\n<p>Available measurement ranges include:<\/p>\n<p>400 mV, 4 V, 40 V, 400 V and 1000 V.<\/p>\n<p>The best specified DC voltage accuracy is:<\/p>\n<p><strong>\u00b1(0.1% of reading + 1 count)<\/strong><\/p>\n<p>This makes the instrument suitable for checking industrial power supplies, electrical circuits and control system signals.<\/p>\n<p>The appropriate measurement category and safety precautions must always be observed.<\/p>\n<h2>True-RMS AC Voltage Measurement<\/h2>\n<p>The Fluke 787B measures True-RMS AC voltage up to:<\/p>\n<p><strong>1000 V<\/strong><\/p>\n<p>The best specified accuracy is:<\/p>\n<p><strong>\u00b1(0.7% of reading + 2 counts)<\/strong><\/p>\n<p>This function is useful for checking electrical supply voltages and industrial equipment.<\/p>\n<p>The True-RMS capability provides advantages when measuring suitable distorted AC waveforms.<\/p>\n<p>Measurement accuracy depends on the signal characteristics, frequency and selected measurement range.<\/p>\n<h2>Resistance Measurement up to 40 M\u03a9<\/h2>\n<p>The Fluke 787B provides resistance measurement over several ranges.<\/p>\n<p>The maximum resistance measurement range is:<\/p>\n<p><strong>40 M\u03a9<\/strong><\/p>\n<p>The best specified accuracy is:<\/p>\n<p><strong>\u00b1(0.2% of reading + 1 count)<\/strong><\/p>\n<p>Resistance measurement is useful for checking electrical components, cables and circuit connections.<\/p>\n<p>The instrument also includes a continuity test function with an audible signal.<\/p>\n<p>This allows technicians to identify electrical connections quickly.<\/p>\n<h2>Frequency Measurement up to 20 kHz<\/h2>\n<p>The Fluke 787B supports frequency measurements from approximately:<\/p>\n<p><strong>0.5 Hz to 20 kHz<\/strong><\/p>\n<p>The best specified accuracy is:<\/p>\n<p><strong>\u00b1(0.005% of reading + 1 count)<\/strong><\/p>\n<p>Frequency measurement is useful for checking electrical signals and industrial control circuits.<\/p>\n<p>The instrument provides measurement ranges up to 19.999 kHz.<\/p>\n<p>This extends its functionality beyond conventional process current calibration.<\/p>\n<h2>Diode and Continuity Testing<\/h2>\n<p>The Fluke 787B includes diode testing and continuity testing.<\/p>\n<p>The diode test displays the forward voltage drop of a semiconductor junction.<\/p>\n<p>The continuity function provides an audible signal when the measured resistance is below approximately 100 \u03a9.<\/p>\n<p>These functions are useful for troubleshooting electrical circuits and checking connections.<\/p>\n<p>They allow technicians to perform routine electrical maintenance without changing instruments.<\/p>\n<h2>Min\/Max\/Average Functions<\/h2>\n<p>The Fluke 787B provides additional measurement functions for analyzing changing electrical signals.<\/p>\n<p>Available functions include:<\/p>\n<ul>\n<li>Minimum value<\/li>\n<li>Maximum value<\/li>\n<li>Average value<\/li>\n<li>Hold<\/li>\n<li>Relative measurement<\/li>\n<\/ul>\n<p>These functions help technicians identify fluctuations and changes in measurement values.<\/p>\n<p>For example, the minimum and maximum functions can be used to investigate voltage variations in an electrical system.<\/p>\n<p>The Hold function allows a displayed measurement value to be retained for convenient reading.<\/p>\n<h2>Fluke Connect Compatibility<\/h2>\n<p>The Fluke 787B supports Fluke Connect functionality when used with the optional IR3000FC communication module.<\/p>\n<p>This enables compatible wireless communication and measurement data transfer.<\/p>\n<p>Technicians can use supported software to monitor, record and share measurement information.<\/p>\n<p>The optional module is not included in the standard instrument configuration.<\/p>\n<p>This feature can be useful for documentation and collaboration during industrial maintenance.<\/p>\n<h2>High Electrical Safety<\/h2>\n<p>The Fluke 787B is designed for professional electrical measurement applications.<\/p>\n<p>The instrument meets the following measurement categories:<\/p>\n<p><strong>CAT III 1000 V<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>CAT IV 600 V<\/strong><\/p>\n<p>The safety classification is based on the applicable IEC 61010 requirements.<\/p>\n<p>These ratings make the instrument suitable for measurements in demanding industrial electrical environments when used correctly.<\/p>\n<p>Appropriate test leads, accessories and personal protective equipment must be selected according to the application.<\/p>\n<h2>Portable and Robust Construction<\/h2>\n<p>The Fluke 787B is designed for mobile industrial use.<\/p>\n<p>The instrument measures approximately:<\/p>\n<p><strong>203 \u00d7 100 \u00d7 50 mm<\/strong><\/p>\n<p>Its weight is approximately:<\/p>\n<p><strong>600 g<\/strong><\/p>\n<p>The compact construction makes it convenient to carry between different measurement locations.<\/p>\n<p>The instrument operates using four AA alkaline batteries.<\/p>\n<p>Typical battery life is approximately 140 hours during measurement operation.<\/p>\n<p>When continuously sourcing 12 mA, the typical battery life is approximately 10 hours.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke 787B<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>787B<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>ProcessMeter<\/td>\n<\/tr>\n<tr>\n<td>Instrument functions<\/td>\n<td>Digital multimeter and mA loop calibrator<\/td>\n<\/tr>\n<tr>\n<td>DC voltage<\/td>\n<td>Up to 1000 V<\/td>\n<\/tr>\n<tr>\n<td>AC voltage<\/td>\n<td>Up to 1000 V True-RMS<\/td>\n<\/tr>\n<tr>\n<td>DC current measurement<\/td>\n<td>Up to 30 mA<\/td>\n<\/tr>\n<tr>\n<td>DC current measurement accuracy<\/td>\n<td>\u00b1(0.05% of reading + 2 counts)<\/td>\n<\/tr>\n<tr>\n<td>Current source<\/td>\n<td>0\u201320 mA or 4\u201320 mA<\/td>\n<\/tr>\n<tr>\n<td>Maximum source current<\/td>\n<td>24 mA<\/td>\n<\/tr>\n<tr>\n<td>Current source accuracy<\/td>\n<td>0.05% of span<\/td>\n<\/tr>\n<tr>\n<td>Current source compliance<\/td>\n<td>Up to 24 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum source load at 20 mA<\/td>\n<td>1200 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Current simulation<\/td>\n<td>0\u201320 mA or 4\u201320 mA<\/td>\n<\/tr>\n<tr>\n<td>External supply for simulation<\/td>\n<td>15\u201348 V DC<\/td>\n<\/tr>\n<tr>\n<td>Resistance measurement<\/td>\n<td>Up to 40 M\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Frequency measurement<\/td>\n<td>0.5 Hz to 20 kHz<\/td>\n<\/tr>\n<tr>\n<td>Diode test<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Continuity test<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Automatic current ramp<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Manual current stepping<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Fluke Connect<\/td>\n<td>With optional IR3000FC<\/td>\n<\/tr>\n<tr>\n<td>Safety rating<\/td>\n<td>CAT III 1000 V \/ CAT IV 600 V<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>\u221220 \u00b0C to +55 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>Four AA batteries<\/td>\n<\/tr>\n<tr>\n<td>Typical battery life, measurement<\/td>\n<td>140 hours<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>203 \u00d7 100 \u00d7 50 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 600 g<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer warranty<\/td>\n<td>3 years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke 787B or Fluke 789?<\/h2>\n<p>The Fluke 787B and Fluke 789 combine digital multimeter functions with process current calibration.<\/p>\n<p>Both instruments support the measurement, sourcing and simulation of 4\u201320 mA signals.<\/p>\n<p>The Fluke 787B is particularly suitable for technicians who require a compact multimeter and current loop calibrator.<\/p>\n<p>The Fluke 789 provides additional functionality, including an integrated 24 V loop power supply.<\/p>\n<p>This makes the Fluke 789 particularly useful when testing transmitters that require an external loop supply.<\/p>\n<p>The appropriate instrument should be selected according to the required measurement functions and process calibration applications.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable electrical measurements.<\/p>\n<p>europascal provides professional calibration services for electrical measuring instruments and process calibration equipment.<\/p>\n<p>The Fluke 787B combines several measurement functions that should be considered when planning a calibration.<\/p>\n<p>These include DC voltage, AC voltage, DC current, AC current, resistance, frequency and current sourcing.<\/p>\n<p>During calibration, the instrument indication or output is compared with a suitable reference standard.<\/p>\n<p>Relevant measurement uncertainty contributions may include reference instrument uncertainty, measurement resolution, repeatability and environmental conditions.<\/p>\n<p>For current sourcing and simulation, the influence of connected loads and external loop supply conditions must also be considered.<\/p>\n<p>europascal supports customers with calibration services and technical advice for professional electrical measurement equipment.<\/p>\n<p>Learn more about the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/?utm_source=chatgpt.com\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Fluke 787B?<\/h2>\n<p>The Fluke 787B combines the essential functions of a digital multimeter and a process current calibrator in one portable instrument.<\/p>\n<p>Its ability to measure, source and simulate 4\u201320 mA signals makes it particularly useful for industrial maintenance and process instrumentation.<\/p>\n<p>The True-RMS multimeter provides extensive electrical measurement functions, while the integrated current source supports the verification of analog process inputs.<\/p>\n<p>Automatic ramping and manual stepping simplify routine testing.<\/p>\n<p>The backlit display, robust construction and high electrical safety ratings make the instrument suitable for demanding industrial environments.<\/p>\n<p>For technicians requiring a versatile measurement instrument for electrical troubleshooting and process calibration, the Fluke 787B provides a practical and efficient solution.<\/p>\n<h2>Typical Applications for the Fluke 787B<\/h2>\n<p>The Fluke 787B is suitable for numerous industrial measurement and calibration applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>4\u201320 mA loop calibration<\/li>\n<li>Process transmitter testing<\/li>\n<li>Pressure transmitter verification<\/li>\n<li>Temperature transmitter testing<\/li>\n<li>Flow transmitter testing<\/li>\n<li>Level transmitter testing<\/li>\n<li>PLC analog input testing<\/li>\n<li>Industrial electrical troubleshooting<\/li>\n<li>DC voltage measurement<\/li>\n<li>AC voltage measurement<\/li>\n<li>Resistance measurement<\/li>\n<li>Frequency measurement<\/li>\n<li>Industrial maintenance<\/li>\n<li>Process instrumentation<\/li>\n<li>Commissioning<\/li>\n<li>Preventive maintenance<\/li>\n<li>Quality assurance<\/li>\n<li>Calibration laboratories<\/li>\n<\/ul>\n<p>The combination of digital multimeter functionality, precise current generation and industrial safety makes the Fluke 787B a professional solution for demanding process measurement applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/?utm_source=chatgpt.com\">Find more Fluke products here.<\/a><\/p>\n<p>Manufacturer information for the Fluke 787B can be found on the <a href=\"https:\/\/www.fluke.com\/en-id\/product\/calibration-tools\/ma-loop-calibrators\/fluke-787b?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">official Fluke website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-787B-789-Process-Meter.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke 787B<\/strong> is a versatile ProcessMeter combining a True-RMS digital multimeter with a precision mA loop calibrator. It measures, sources and simulates <strong>4\u201320 mA signals<\/strong> with <strong>0.05% of span output accuracy<\/strong> and measures voltage up to <strong>1000 V<\/strong>.<\/p>\n<p>Featuring automatic current ramping, a backlit display and CAT III 1000 V \/ CAT IV 600 V safety ratings, it is ideal for industrial maintenance and process calibration.<\/p>\n","protected":false},"featured_media":7012,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[64,62],"product_tag":[4744,6611,6612,4766,6613,3918,6614,6615,4808,3922,4592,4593,4761,6616,6617,6618,6619,6620,6621,6622],"class_list":["post-7010","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-process-multifunction-calibrators","product_cat-electrical","product_tag-4-bis-20-ma-kalibrator","product_tag-cat-iii-1000-v","product_tag-cat-iv-600-v","product_tag-digitalmultimeter","product_tag-drucktransmitter-pruefen","product_tag-elektrische-kalibrierung","product_tag-fluke-787b","product_tag-fluke-processmeter","product_tag-instandhaltung","product_tag-kalibrierlabor","product_tag-ma-kalibrator","product_tag-prozesskalibrator","product_tag-prozessmesstechnik","product_tag-prozesssignal-kalibrieren","product_tag-stromquelle-4-bis-20-ma","product_tag-stromschleife-pruefen","product_tag-stromschleife-simulieren","product_tag-stromschleifenkalibrator","product_tag-temperaturtransmitter-pruefen","product_tag-true-rms-multimeter","pa_bauart-hand-held","pa_hart-kommunikation-no","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/7010","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/7012"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=7010"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=7010"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=7010"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=7010"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}