{"id":7037,"date":"2026-07-17T16:22:08","date_gmt":"2026-07-17T16:22:08","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-772\/"},"modified":"2026-10-15T09:05:29","modified_gmt":"2026-10-15T09:05:29","slug":"fluke-calibration-772","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-772\/","title":{"rendered":"Fluke Calibration 772 Versatile Milliamp Clamp Meter"},"content":{"rendered":"<p>The <strong>Fluke Calibration 772<\/strong> is a professional milliamp process clamp meter designed for measuring, sourcing and simulating 4\u201320 mA signals in industrial process control systems.<\/p>\n<p>Its most important advantage is the ability to measure current signals <strong>without interrupting the current loop<\/strong>. This allows maintenance technicians and calibration specialists to check process signals while the system remains in operation.<\/p>\n<p>The Fluke Calibration 772 combines a highly sensitive milliamp clamp with integrated current measurement, current sourcing and transmitter simulation functions.<\/p>\n<p>With an accuracy of <strong>0.2% + 5 counts<\/strong> for clamp measurements up to 20.99 mA and a resolution of <strong>0.01 mA<\/strong>, the instrument is particularly suitable for troubleshooting industrial instrumentation.<\/p>\n<p>The integrated current source provides signals from 0 to 24 mA, allowing technicians to test controllers, analog inputs, positioners and other process control equipment.<\/p>\n<p>A detachable measurement clamp, illuminated display and compact construction make the instrument especially convenient for field applications.<\/p>\n<p>The Fluke Calibration 772 is suitable for maintenance departments, industrial production facilities, process instrumentation specialists and calibration laboratories.<\/p>\n<p>europascal supports customers with professional electrical calibration equipment, technical advice and calibration services.<\/p>\n<p>For information about traceable electrical calibration, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<ul>\n<li>Measurement of 4\u201320 mA signals without interrupting the current loop<\/li>\n<li>Clamp measurement range up to 100 mA<\/li>\n<li>Resolution of 0.01 mA in the lower clamp measurement range<\/li>\n<li>Clamp measurement accuracy of 0.2% + 5 counts up to 20.99 mA<\/li>\n<li>Direct current measurement from 0 to 24 mA<\/li>\n<li>Integrated current source from 0 to 24 mA<\/li>\n<li>Simulation of 4\u201320 mA transmitter signals<\/li>\n<li>Integrated 24 V loop power supply<\/li>\n<li>Automatic current ramp function<\/li>\n<li>Automatic 25% current steps<\/li>\n<li>Detachable measurement clamp<\/li>\n<li>Measurement Spotlight for poorly illuminated locations<\/li>\n<li>Dual backlit display<\/li>\n<li>Simultaneous indication of current and percentage of 4\u201320 mA span<\/li>\n<li>Hold function for capturing measurement values<\/li>\n<li>Suitable for testing PLC analog inputs<\/li>\n<li>Suitable for troubleshooting industrial transmitters<\/li>\n<li>Compact design weighing approximately 410 g<\/li>\n<li>Battery operation using four AA batteries<\/li>\n<li>Professional calibration support from europascal<\/li>\n<\/ul>\n<h2>Ideal for Industrial Process Calibration<\/h2>\n<p>The Fluke Calibration 772 is designed for applications involving industrial current loops.<\/p>\n<p>In industrial automation, analog signals are frequently transmitted using a standardized current range of:<\/p>\n<p><strong>4\u201320 mA<\/strong><\/p>\n<p>This signal represents a defined measurement range.<\/p>\n<p>For example, a pressure transmitter with a measuring range from 0 to 10 bar may generate the following signals:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Pressure<\/th>\n<th>Output Current<\/th>\n<\/tr>\n<tr>\n<td>0 bar<\/td>\n<td>4 mA<\/td>\n<\/tr>\n<tr>\n<td>2.5 bar<\/td>\n<td>8 mA<\/td>\n<\/tr>\n<tr>\n<td>5 bar<\/td>\n<td>12 mA<\/td>\n<\/tr>\n<tr>\n<td>7.5 bar<\/td>\n<td>16 mA<\/td>\n<\/tr>\n<tr>\n<td>10 bar<\/td>\n<td>20 mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The Fluke Calibration 772 allows technicians to measure these signals directly.<\/p>\n<p>The instrument can also generate corresponding current values to test the connected control system.<\/p>\n<p>This makes it particularly useful for commissioning, troubleshooting and preventive maintenance.<\/p>\n<h2>Measure Current Without Interrupting the Loop<\/h2>\n<p>One of the most important features of the <strong>Fluke Calibration 772<\/strong> is its ability to measure milliamp signals using a current clamp.<\/p>\n<p>Conventional current measurement requires the electrical circuit to be opened and the measuring instrument connected in series.<\/p>\n<p>This can interrupt the process signal and potentially affect the operation of connected equipment.<\/p>\n<p>The Fluke Calibration 772 avoids this problem.<\/p>\n<p>The measurement clamp is positioned around a single conductor carrying the current signal.<\/p>\n<p>The instrument measures the current without requiring an electrical connection to the circuit.<\/p>\n<p>This provides several advantages:<\/p>\n<ul>\n<li>No interruption of the current loop<\/li>\n<li>Reduced risk of wiring errors<\/li>\n<li>Faster troubleshooting<\/li>\n<li>Reduced process downtime<\/li>\n<li>Convenient measurement in control cabinets<\/li>\n<li>Improved efficiency during maintenance<\/li>\n<\/ul>\n<p>The conductor must be positioned correctly inside the clamp.<\/p>\n<p>The maximum conductor diameter is 4.5 mm.<\/p>\n<h2>Clamp Measurement Range up to 100 mA<\/h2>\n<p>The Fluke Calibration 772 provides two clamp measurement ranges.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Measurement Range<\/th>\n<th>Accuracy<\/th>\n<\/tr>\n<tr>\n<td>0 to 20.99 mA<\/td>\n<td>\u00b1(0.2% of reading + 5 counts)<\/td>\n<\/tr>\n<tr>\n<td>21.0 to 100.0 mA<\/td>\n<td>\u00b1(1% of reading + 5 counts)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The lower measurement range provides a resolution of 0.01 mA.<\/p>\n<p>The higher range is particularly useful for checking current signals in older industrial control systems.<\/p>\n<p>The measurement range up to 100 mA extends the instrument&#8217;s usefulness beyond conventional 4\u201320 mA applications.<\/p>\n<h2>Direct Current Measurement<\/h2>\n<p>In addition to non-contact clamp measurements, the Fluke Calibration 772 can measure current directly using its electrical test terminals.<\/p>\n<p>The direct measurement range is:<\/p>\n<p><strong>0 to 24.00 mA<\/strong><\/p>\n<p>The specified accuracy is:<\/p>\n<p><strong>\u00b1(0.2% of reading + 2 counts)<\/strong><\/p>\n<p>The resolution is:<\/p>\n<p><strong>0.01 mA<\/strong><\/p>\n<p>Direct measurement requires the instrument to be connected in series with the current loop.<\/p>\n<p>This function is useful when a conventional electrical current measurement is required.<\/p>\n<p>It also allows technicians to compare direct current measurements with clamp measurements.<\/p>\n<h2>Integrated Current Source<\/h2>\n<p>The Fluke Calibration 772 includes an integrated current source.<\/p>\n<p>The output range is:<\/p>\n<p><strong>0 to 24.00 mA<\/strong><\/p>\n<p>The specified accuracy is:<\/p>\n<p><strong>\u00b1(0.2% of output + 2 counts)<\/strong><\/p>\n<p>The instrument can deliver up to 24 mA into a load of 1000 \u03a9.<\/p>\n<p>This function allows technicians to generate defined current signals for testing industrial equipment.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>PLC analog input testing<\/li>\n<li>Process controller testing<\/li>\n<li>Current input verification<\/li>\n<li>Indicator calibration<\/li>\n<li>Recorder testing<\/li>\n<li>I\/P converter testing<\/li>\n<li>Positioner testing<\/li>\n<\/ul>\n<p>The current source can be adjusted manually or operated using automatic output functions.<\/p>\n<h2>Simulation of 4\u201320 mA Signals<\/h2>\n<p>The Fluke Calibration 772 can simulate a current transmitter.<\/p>\n<p>The simulation range is:<\/p>\n<p><strong>0 to 24.00 mA<\/strong><\/p>\n<p>The specified accuracy is:<\/p>\n<p><strong>\u00b1(0.2% of output + 2 counts)<\/strong><\/p>\n<p>In simulation mode, the instrument controls the current supplied by an external loop power source.<\/p>\n<p>This allows technicians to replace the transmitter signal temporarily with a defined test signal.<\/p>\n<p>For example, a technician can simulate 4 mA, 12 mA and 20 mA to verify the response of a connected controller.<\/p>\n<p>This is particularly useful during commissioning and troubleshooting.<\/p>\n<p>The maximum permitted external voltage for current simulation is 50 V DC.<\/p>\n<h2>Integrated 24 V Loop Power Supply<\/h2>\n<p>The Fluke Calibration 772 provides a 24 V loop power function.<\/p>\n<p>This allows compatible two-wire transmitters to be supplied during testing.<\/p>\n<p>The function is useful when an external loop power supply is unavailable.<\/p>\n<p>It simplifies field measurements and helps reduce the amount of additional equipment required.<\/p>\n<p>The transmitter and measuring instrument must be connected according to the manufacturer&#8217;s operating instructions.<\/p>\n<h2>Automatic Current Stepping<\/h2>\n<p>The Fluke Calibration 772 supports automatic current stepping.<\/p>\n<p>The output can be changed in increments corresponding to 25% of the standard 4\u201320 mA span.<\/p>\n<p>Typical output values are:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Percentage<\/th>\n<th>Current<\/th>\n<\/tr>\n<tr>\n<td>0%<\/td>\n<td>4 mA<\/td>\n<\/tr>\n<tr>\n<td>25%<\/td>\n<td>8 mA<\/td>\n<\/tr>\n<tr>\n<td>50%<\/td>\n<td>12 mA<\/td>\n<\/tr>\n<tr>\n<td>75%<\/td>\n<td>16 mA<\/td>\n<\/tr>\n<tr>\n<td>100%<\/td>\n<td>20 mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>This function is particularly useful when testing analog input channels.<\/p>\n<p>Instead of manually adjusting the current output, technicians can quickly select standardized test points.<\/p>\n<p>Automatic stepping helps improve efficiency and repeatability during routine testing.<\/p>\n<h2>Automatic Current Ramp Function<\/h2>\n<p>The Fluke Calibration 772 also provides an automatic current ramp function.<\/p>\n<p>The instrument can continuously change the output current over a defined range.<\/p>\n<p>This is useful for observing the response of connected process equipment.<\/p>\n<p>Typical applications include testing analog indicators, control valves and process controllers.<\/p>\n<p>The ramp function helps identify irregularities in the response of the connected device.<\/p>\n<p>It can also be used during functional testing and commissioning.<\/p>\n<h2>Detachable Measurement Clamp<\/h2>\n<p>The Fluke Calibration 772 features a detachable current clamp.<\/p>\n<p>The clamp can be separated from the main instrument and used with its extension cable.<\/p>\n<p>This allows measurements in locations where access is restricted.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Industrial control cabinets<\/li>\n<li>Densely populated terminal blocks<\/li>\n<li>Process instrumentation panels<\/li>\n<li>Electrical distribution enclosures<\/li>\n<li>Machinery control systems<\/li>\n<\/ul>\n<p>The detachable clamp improves flexibility and allows technicians to position the measuring element more conveniently.<\/p>\n<h2>Illuminated Display and Measurement Spotlight<\/h2>\n<p>The Fluke Calibration 772 includes a backlit display.<\/p>\n<p>The instrument can display the measured current and the corresponding percentage of the 4\u201320 mA span.<\/p>\n<p>This makes it easier to interpret current signals during maintenance.<\/p>\n<p>The integrated Measurement Spotlight illuminates the measurement area.<\/p>\n<p>This is particularly useful in poorly illuminated control cabinets.<\/p>\n<p>The instrument also provides a Hold function for retaining displayed measurement values.<\/p>\n<h2>Calibration of Process Control Systems<\/h2>\n<p>The Fluke Calibration 772 is particularly suitable for testing process control systems.<\/p>\n<p>Industrial control systems rely on accurate analog signals to monitor and control production processes.<\/p>\n<p>The instrument can be used to verify the current signals transmitted between sensors, transmitters, controllers and actuators.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>PLC analog input verification<\/li>\n<li>Distributed control system testing<\/li>\n<li>Process transmitter troubleshooting<\/li>\n<li>Current loop verification<\/li>\n<li>Control valve testing<\/li>\n<li>Process indicator calibration<\/li>\n<\/ul>\n<p>The combination of current measurement, sourcing and simulation functions allows technicians to perform several testing tasks using one instrument.<\/p>\n<h2>Calibration of Pressure Transmitters<\/h2>\n<p>Pressure transmitters frequently use 4\u201320 mA signals.<\/p>\n<p>The Fluke Calibration 772 can measure the transmitter output without interrupting the current loop.<\/p>\n<p>This allows technicians to verify the electrical output while the transmitter remains connected to the control system.<\/p>\n<p>For a complete pressure transmitter calibration, an appropriate pressure reference and pressure source are also required.<\/p>\n<p>The Fluke Calibration 772 measures the electrical signal but does not generate or measure pressure.<\/p>\n<h2>Calibration of Temperature Transmitters<\/h2>\n<p>Temperature transmitters convert RTD or thermocouple signals into standardized current outputs.<\/p>\n<p>The Fluke Calibration 772 can be used to measure or simulate the corresponding current signals.<\/p>\n<p>For complete temperature transmitter calibration, a suitable temperature source or electrical sensor simulator is additionally required.<\/p>\n<p>The instrument is therefore a useful component of a temperature transmitter calibration setup.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 772<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke Calibration<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>772<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Milliamp Process Clamp Meter<\/td>\n<\/tr>\n<tr>\n<td>Clamp measurement range 1<\/td>\n<td>0 to 20.99 mA<\/td>\n<\/tr>\n<tr>\n<td>Clamp accuracy range 1<\/td>\n<td>\u00b1(0.2% + 5 counts)<\/td>\n<\/tr>\n<tr>\n<td>Clamp measurement range 2<\/td>\n<td>21.0 to 100.0 mA<\/td>\n<\/tr>\n<tr>\n<td>Clamp accuracy range 2<\/td>\n<td>\u00b1(1% + 5 counts)<\/td>\n<\/tr>\n<tr>\n<td>Clamp resolution<\/td>\n<td>0.01 mA \/ 0.1 mA<\/td>\n<\/tr>\n<tr>\n<td>Direct current measurement<\/td>\n<td>0 to 24.00 mA<\/td>\n<\/tr>\n<tr>\n<td>Direct measurement accuracy<\/td>\n<td>\u00b1(0.2% + 2 counts)<\/td>\n<\/tr>\n<tr>\n<td>Current source<\/td>\n<td>0 to 24.00 mA<\/td>\n<\/tr>\n<tr>\n<td>Current source accuracy<\/td>\n<td>\u00b1(0.2% + 2 counts)<\/td>\n<\/tr>\n<tr>\n<td>Current simulation<\/td>\n<td>0 to 24.00 mA<\/td>\n<\/tr>\n<tr>\n<td>Current simulation accuracy<\/td>\n<td>\u00b1(0.2% + 2 counts)<\/td>\n<\/tr>\n<tr>\n<td>Maximum source load<\/td>\n<td>1000 \u03a9 at 24 mA<\/td>\n<\/tr>\n<tr>\n<td>Maximum simulation voltage<\/td>\n<td>50 V DC<\/td>\n<\/tr>\n<tr>\n<td>Loop power<\/td>\n<td>24 V<\/td>\n<\/tr>\n<tr>\n<td>Automatic stepping<\/td>\n<td>25% increments<\/td>\n<\/tr>\n<tr>\n<td>Automatic ramp<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Detachable clamp<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Maximum conductor diameter<\/td>\n<td>4.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>Dual backlit display<\/td>\n<\/tr>\n<tr>\n<td>Measurement Spotlight<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Hold function<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>\u221210 \u00b0C to +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>\u221225 \u00b0C to +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Protection rating<\/td>\n<td>IP40<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>Four AA batteries<\/td>\n<\/tr>\n<tr>\n<td>Battery life<\/td>\n<td>Approx. 12 hours at 12 mA output into 500 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Approx. 44 \u00d7 70 \u00d7 246 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>Approx. 410 g<\/td>\n<\/tr>\n<tr>\n<td>Warranty<\/td>\n<td>3 years on electronics<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 771, 772 and 773 Comparison<\/h2>\n<p>The Fluke Calibration 772 belongs to a family of professional milliamp process clamp meters.<\/p>\n<p>The models differ in their measurement and output capabilities.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Function<\/th>\n<th>Fluke 771<\/th>\n<th>Fluke 772<\/th>\n<th>Fluke 773<\/th>\n<\/tr>\n<tr>\n<td>Clamp measurement<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Direct mA measurement<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>mA source<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>mA simulation<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>24 V loop power<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>DC voltage measurement<\/td>\n<td>No<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>DC voltage source<\/td>\n<td>No<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Scaled mA output<\/td>\n<td>No<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The Fluke Calibration 771 is designed primarily for non-contact current measurement.<\/p>\n<p>The Fluke Calibration 772 adds current sourcing, current simulation and direct current measurement.<\/p>\n<p>The Fluke Calibration 773 provides additional voltage measurement and voltage output functions.<\/p>\n<p>For technicians working primarily with 4\u201320 mA process signals, the Fluke Calibration 772 provides an excellent combination of functionality and portability.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable electrical measurements.<\/p>\n<p>europascal provides professional calibration services for electrical measuring instruments and process calibration equipment.<\/p>\n<p>When calibrating a milliamp process clamp meter, several measurement characteristics must be considered.<\/p>\n<p>These include:<\/p>\n<ul>\n<li>Clamp current measurement accuracy<\/li>\n<li>Direct current measurement accuracy<\/li>\n<li>Current source accuracy<\/li>\n<li>Current simulation accuracy<\/li>\n<li>Measurement resolution<\/li>\n<li>Measurement repeatability<\/li>\n<li>Environmental influences<\/li>\n<\/ul>\n<p>For demanding applications, measurement uncertainty should be evaluated according to the relevant calibration procedure.<\/p>\n<p>Professional calibration helps ensure that process instrumentation measurements remain reliable and traceable.<\/p>\n<p>For more information, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Fluke Calibration 772?<\/h2>\n<p>The Fluke Calibration 772 combines non-contact milliamp measurement with integrated process calibration functions.<\/p>\n<p>Its ability to measure 4\u201320 mA signals without interrupting the current loop helps reduce process downtime.<\/p>\n<p>The detachable measurement clamp provides convenient access to conductors in crowded control cabinets.<\/p>\n<p>Integrated current sourcing and simulation functions allow technicians to test industrial controllers and transmitters.<\/p>\n<p>Automatic current stepping and ramp functions simplify routine testing.<\/p>\n<p>The illuminated display and Measurement Spotlight improve usability in industrial environments.<\/p>\n<p>With a weight of approximately 410 g, the instrument is convenient for mobile maintenance and field service applications.<\/p>\n<p>For process instrumentation technicians, maintenance engineers and calibration specialists, the Fluke Calibration 772 provides a versatile solution for industrial current loop testing.<\/p>\n<p>europascal supports customers with professional electrical calibration equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the Fluke Calibration 772<\/h2>\n<p>Typical applications include:<\/p>\n<ul>\n<li>4\u201320 mA loop measurement<\/li>\n<li>Process current measurement<\/li>\n<li>PLC analog input testing<\/li>\n<li>Current loop troubleshooting<\/li>\n<li>Pressure transmitter testing<\/li>\n<li>Temperature transmitter testing<\/li>\n<li>Process controller verification<\/li>\n<li>Current signal simulation<\/li>\n<li>Current source testing<\/li>\n<li>Industrial instrumentation maintenance<\/li>\n<li>Control valve testing<\/li>\n<li>I\/P converter testing<\/li>\n<li>Process indicator verification<\/li>\n<li>Preventive maintenance<\/li>\n<li>Commissioning<\/li>\n<li>Calibration laboratories<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Process automation<\/li>\n<\/ul>\n<p>The combination of non-contact current measurement, integrated current sourcing, transmitter simulation and portable construction makes the Fluke Calibration 772 a professional solution for industrial process calibration applications.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Find more Fluke Calibration products here.<\/a><\/p>\n<p>Manufacturer information for the Fluke Calibration 772 can be found on the <a href=\"https:\/\/www.fluke.com\/en-vn\/product\/calibration-tools\/ma-loop-calibrators\/fluke-772\" target=\"_blank\" rel=\"noopener\">official Fluke Calibration website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-772-773-Milliamp-Process-Clamp-Meter.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 772<\/strong> is a portable milliamp process clamp meter for measuring <strong>4\u201320 mA signals without interrupting the current loop<\/strong>.<\/p>\n<p>With <strong>0.01 mA resolution<\/strong>, integrated current sourcing and simulation, a detachable clamp and 24 V loop power, it is ideal for testing transmitters, PLC inputs and industrial process control systems.<\/p>\n","protected":false},"featured_media":7038,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[89],"product_cat":[62,1241],"product_tag":[5721,4744,6670,6613,6690,6691,4808,6673,6674,6675,6676,4593,5803,4761,6678,6680,6618,6620,6621,4958],"class_list":["post-7037","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-calibration","product_cat-electrical","product_cat-clamp-meters","product_tag-24-v-loop-power","product_tag-4-bis-20-ma-kalibrator","product_tag-4-bis-20-ma-strommesszange","product_tag-drucktransmitter-pruefen","product_tag-fluke-772","product_tag-fluke-calibration-772","product_tag-instandhaltung","product_tag-ma-clamp-meter","product_tag-ma-prozessstrommesszange","product_tag-ma-quelle","product_tag-ma-simulation","product_tag-prozesskalibrator","product_tag-prozesskalibrierung","product_tag-prozessmesstechnik","product_tag-sps-eingang-pruefen","product_tag-stromschleife-messen","product_tag-stromschleife-pruefen","product_tag-stromschleifenkalibrator","product_tag-temperaturtransmitter-pruefen","product_tag-transmitter-pruefen","pa_bauart-handgeraet","pa_hart-kommunikation-nein","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/7037","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/7038"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=7037"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=7037"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=7037"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=7037"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}