{"id":7040,"date":"2026-07-17T16:22:02","date_gmt":"2026-07-17T16:22:02","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-771\/"},"modified":"2026-10-15T09:09:07","modified_gmt":"2026-10-15T09:09:07","slug":"fluke-calibration-771","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-calibration-771\/","title":{"rendered":"Fluke Calibration 771 Precise Milliamp Clamp Meter"},"content":{"rendered":"<p>The <strong>Fluke Calibration 771<\/strong> is a professional milliamp process clamp meter designed for accurate measurement and troubleshooting of 4\u201320 mA current loops without interrupting the electrical circuit.<\/p>\n<p>With an accuracy of <strong>0.2% of reading plus 2 counts<\/strong> in its primary measurement range and a resolution of <strong>0.01 mA<\/strong>, the Fluke Calibration 771 provides reliable measurement performance for industrial process instrumentation, automation systems and maintenance applications.<\/p>\n<p>The instrument allows technicians to measure DC current signals directly around an individual conductor without disconnecting wires or interrupting the process.<\/p>\n<p>This makes the Fluke Calibration 771 particularly suitable for troubleshooting temperature transmitters, pressure transmitters, flow measurement systems and programmable logic controller (PLC) input and output signals.<\/p>\n<p>Its detachable clamp, backlit display and compact design make it an essential tool for maintenance technicians, instrumentation engineers and calibration professionals.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The Fluke Calibration 771 combines accurate current measurement with convenient operation and excellent portability.<\/p>\n<p>Its main advantages include:<\/p>\n<ul>\n<li>Measurement of 4\u201320 mA signals without breaking the current loop<\/li>\n<li>DC current measurement range up to approximately 100 mA<\/li>\n<li>Accuracy of 0.2% of reading plus 2 counts in the primary range<\/li>\n<li>Measurement resolution of 0.01 mA<\/li>\n<li>Suitable for industrial 4\u201320 mA current loops<\/li>\n<li>Detachable clamp for measurements in confined spaces<\/li>\n<li>Maximum conductor diameter of 4.5 mm<\/li>\n<li>Dual backlit display<\/li>\n<li>Simultaneous indication of current and percentage of the 4\u201320 mA span<\/li>\n<li>Integrated LED flashlight<\/li>\n<li>Measurement hold function<\/li>\n<li>Suitable for PLC analog input and output testing<\/li>\n<li>Suitable for temperature transmitter troubleshooting<\/li>\n<li>Suitable for pressure transmitter troubleshooting<\/li>\n<li>Suitable for flow transmitter troubleshooting<\/li>\n<li>Compact construction weighing only 260 g<\/li>\n<li>Battery operation using two AA batteries<\/li>\n<li>Typical battery life of 40 hours<\/li>\n<li>IP40 protection rating<\/li>\n<li>Suitable for industrial maintenance and field service<\/li>\n<\/ul>\n<h2>Measurement of 4\u201320 mA Signals Without Interrupting the Loop<\/h2>\n<p>The <strong>Fluke Calibration 771<\/strong> is designed for measuring low-level DC current signals in industrial process control systems.<\/p>\n<p>Conventional current measurements often require the electrical circuit to be opened and the measuring instrument to be connected in series.<\/p>\n<p>This procedure can interrupt the process and may require additional safety precautions.<\/p>\n<p>The Fluke Calibration 771 eliminates this requirement.<\/p>\n<p>Its sensitive clamp measures the current flowing through an individual conductor without requiring direct electrical contact.<\/p>\n<p>This allows technicians to check process signals while the system remains operational.<\/p>\n<p>The instrument is particularly useful in continuous production environments where process interruptions can result in expensive downtime.<\/p>\n<p>Typical applications include checking the output signals of pressure transmitters, temperature transmitters, level transmitters and flow measurement instruments.<\/p>\n<h2>High Measurement Accuracy<\/h2>\n<p>The Fluke Calibration 771 provides accurate DC current measurement over two ranges.<\/p>\n<p>The manufacturer specifies:<\/p>\n<p><strong>0 to 20.99 mA: \u00b1(0.2% of reading + 2 counts)<\/strong><\/p>\n<p><strong>21.0 to approximately 100 mA: \u00b1(1% of reading + 5 counts)<\/strong><\/p>\n<p>These specifications apply under the manufacturer&#8217;s defined reference conditions.<\/p>\n<p>The primary measurement range covers the standard 4\u201320 mA signals used in industrial automation.<\/p>\n<p>For demanding measurement applications, the specified accuracy must be considered when evaluating the measurement uncertainty.<\/p>\n<p>The accuracy specification should not be confused with the uncertainty stated on an individual calibration certificate.<\/p>\n<h2>High Resolution of 0.01 mA<\/h2>\n<p>The Fluke Calibration 771 provides a resolution of:<\/p>\n<p><strong>0.01 mA<\/strong><\/p>\n<p>This resolution allows small changes in process current to be detected.<\/p>\n<p>For a standard 4\u201320 mA current loop, the instrument can display current changes in increments of 10 \u00b5A.<\/p>\n<p>This is particularly useful when investigating unstable transmitter outputs or checking process signals at different operating points.<\/p>\n<p>The display resolution does not represent the absolute measurement accuracy.<\/p>\n<p>Both accuracy and resolution must be considered when evaluating measurement results.<\/p>\n<h2>Ideal for Industrial 4\u201320 mA Current Loops<\/h2>\n<p>The 4\u201320 mA current loop is widely used in industrial process instrumentation.<\/p>\n<p>A current of 4 mA typically represents the lower end of the configured measurement range.<\/p>\n<p>A current of 20 mA represents the upper end.<\/p>\n<p>The relationship between current and the measured process variable is usually linear for transmitters configured with a linear output characteristic.<\/p>\n<p>For example, a pressure transmitter configured for 0 to 10 bar may provide:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Current Signal<\/th>\n<th>Percentage of Span<\/th>\n<th>Pressure<\/th>\n<\/tr>\n<tr>\n<td>4 mA<\/td>\n<td>0%<\/td>\n<td>0 bar<\/td>\n<\/tr>\n<tr>\n<td>8 mA<\/td>\n<td>25%<\/td>\n<td>2.5 bar<\/td>\n<\/tr>\n<tr>\n<td>12 mA<\/td>\n<td>50%<\/td>\n<td>5 bar<\/td>\n<\/tr>\n<tr>\n<td>16 mA<\/td>\n<td>75%<\/td>\n<td>7.5 bar<\/td>\n<\/tr>\n<tr>\n<td>20 mA<\/td>\n<td>100%<\/td>\n<td>10 bar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The Fluke Calibration 771 allows these signals to be measured directly without interrupting the loop.<\/p>\n<p>This makes it suitable for troubleshooting and verifying transmitter output signals.<\/p>\n<h2>Dual Backlit Display<\/h2>\n<p>The Fluke Calibration 771 features a dual backlit display.<\/p>\n<p>The display simultaneously indicates the measured current and its corresponding percentage of the standard 4\u201320 mA range.<\/p>\n<p>This simplifies the interpretation of process signals.<\/p>\n<p>Technicians can immediately identify whether the transmitter is operating near the lower or upper end of its configured range.<\/p>\n<p>The backlight improves readability in poorly illuminated industrial environments.<\/p>\n<p>This is particularly useful when working inside electrical cabinets or process control panels.<\/p>\n<h2>Detachable Measurement Clamp<\/h2>\n<p>The Fluke Calibration 771 features a detachable measurement clamp.<\/p>\n<p>The clamp can be separated from the main instrument and connected through its extension cable.<\/p>\n<p>This allows the clamp to be positioned around a conductor while the display remains accessible.<\/p>\n<p>The detachable design is particularly useful when working in confined spaces.<\/p>\n<p>Examples include crowded control cabinets, terminal boxes and industrial instrumentation panels.<\/p>\n<p>The maximum conductor diameter is:<\/p>\n<p><strong>4.5 mm<\/strong><\/p>\n<p>For accurate measurement, only the individual conductor carrying the current to be measured should be enclosed by the clamp.<\/p>\n<h2>Integrated LED Flashlight<\/h2>\n<p>The Fluke Calibration 771 includes an integrated LED flashlight.<\/p>\n<p>This feature helps technicians identify individual conductors in poorly illuminated locations.<\/p>\n<p>The flashlight is particularly useful when working inside control cabinets or industrial electrical enclosures.<\/p>\n<p>It reduces the need for additional lighting equipment during routine measurements.<\/p>\n<h2>Measurement Hold Function<\/h2>\n<p>The Fluke Calibration 771 features a measurement hold function.<\/p>\n<p>This allows the displayed measurement value to be retained for convenient reading and documentation.<\/p>\n<p>The function is useful when the clamp is positioned in a location where the display cannot be viewed continuously.<\/p>\n<p>Technicians can capture a reading and review it after moving the instrument to a more convenient position.<\/p>\n<p>This simplifies maintenance and troubleshooting procedures.<\/p>\n<h2>Measurement of PLC Analog Signals<\/h2>\n<p>The Fluke Calibration 771 is suitable for measuring analog current signals used in programmable logic controllers.<\/p>\n<p>PLCs commonly use 4\u201320 mA signals for communication with industrial sensors and transmitters.<\/p>\n<p>The instrument can be used to check current signals at analog inputs and outputs.<\/p>\n<p>This helps identify problems such as incorrect transmitter scaling, unexpected signal levels or interrupted measurement chains.<\/p>\n<p>The nonintrusive measurement method allows the process loop to remain connected during testing.<\/p>\n<h2>Temperature Transmitter Troubleshooting<\/h2>\n<p>Temperature transmitters convert temperature sensor signals into standardized electrical current signals.<\/p>\n<p>A common configuration is a 4\u201320 mA output.<\/p>\n<p>The Fluke Calibration 771 allows the transmitter output current to be measured without disconnecting the loop.<\/p>\n<p>For example, a temperature transmitter configured for 0 to 100 \u00b0C would normally provide 12 mA at 50 \u00b0C if the output characteristic is linear.<\/p>\n<p>By comparing the measured current with the expected value, technicians can investigate transmitter performance.<\/p>\n<p>For a complete temperature calibration, a suitable temperature source and reference thermometer are also required.<\/p>\n<h2>Pressure Transmitter Troubleshooting<\/h2>\n<p>The Fluke Calibration 771 is also suitable for checking pressure transmitter output signals.<\/p>\n<p>Pressure transmitters commonly convert pressure measurements into 4\u201320 mA current signals.<\/p>\n<p>The instrument allows the output current to be checked while the transmitter remains connected to the process control system.<\/p>\n<p>This is useful when investigating unexpected pressure indications or control system alarms.<\/p>\n<p>For a complete pressure calibration, a suitable pressure standard and pressure generation system are required.<\/p>\n<p>The Fluke Calibration 771 measures the electrical output signal but does not generate pressure.<\/p>\n<h2>Flow and Level Transmitter Testing<\/h2>\n<p>The Fluke Calibration 771 can also be used to check the current outputs of flow and level transmitters.<\/p>\n<p>These instruments are widely used in industrial production, water treatment and process automation.<\/p>\n<p>The current signal can be measured directly at the transmitter or at an accessible point in the control circuit.<\/p>\n<p>This helps technicians verify signal transmission and investigate unexpected process indications.<\/p>\n<h2>Measurement of Older 10\u201350 mA Systems<\/h2>\n<p>In addition to standard 4\u201320 mA current loops, the Fluke Calibration 771 can measure higher current signals.<\/p>\n<p>Its extended measurement range makes it suitable for checking older industrial control systems using 10\u201350 mA signals.<\/p>\n<p>This provides additional flexibility when maintaining existing industrial installations.<\/p>\n<p>The accuracy in the higher measurement range is lower than in the primary 4\u201320 mA range.<\/p>\n<h2>Compact and Portable Construction<\/h2>\n<p>The Fluke Calibration 771 is designed for convenient field operation.<\/p>\n<p>Its dimensions are:<\/p>\n<p><strong>59 \u00d7 38 \u00d7 212 mm<\/strong><\/p>\n<p>The instrument weighs approximately:<\/p>\n<p><strong>260 g<\/strong><\/p>\n<p>This compact design makes it easy to transport between measurement locations.<\/p>\n<p>The lightweight construction is particularly useful for maintenance technicians who perform measurements throughout industrial facilities.<\/p>\n<h2>Long Battery Life<\/h2>\n<p>The Fluke Calibration 771 operates using two AA alkaline batteries.<\/p>\n<p>The manufacturer specifies a typical battery life of:<\/p>\n<p><strong>40 hours<\/strong><\/p>\n<p>This provides sufficient operating time for many routine maintenance applications.<\/p>\n<p>The battery-powered design eliminates the need for an external power supply during measurements.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke Calibration 771<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>771<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Milliamp Process Clamp Meter<\/td>\n<\/tr>\n<tr>\n<td>Measurement principle<\/td>\n<td>Nonintrusive DC current measurement<\/td>\n<\/tr>\n<tr>\n<td>Primary application<\/td>\n<td>4\u201320 mA current loops<\/td>\n<\/tr>\n<tr>\n<td>Primary measurement range<\/td>\n<td>0 to 20.99 mA<\/td>\n<\/tr>\n<tr>\n<td>Extended measurement range<\/td>\n<td>21.0 to approximately 100 mA<\/td>\n<\/tr>\n<tr>\n<td>Accuracy, primary range<\/td>\n<td>\u00b1(0.2% of reading + 2 counts)<\/td>\n<\/tr>\n<tr>\n<td>Accuracy, extended range<\/td>\n<td>\u00b1(1% of reading + 5 counts)<\/td>\n<\/tr>\n<tr>\n<td>Resolution, primary range<\/td>\n<td>0.01 mA<\/td>\n<\/tr>\n<tr>\n<td>Maximum conductor diameter<\/td>\n<td>4.5 mm<\/td>\n<\/tr>\n<tr>\n<td>Clamp<\/td>\n<td>Detachable<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>Dual backlit display<\/td>\n<\/tr>\n<tr>\n<td>Percentage indication<\/td>\n<td>4\u201320 mA span<\/td>\n<\/tr>\n<tr>\n<td>LED flashlight<\/td>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<td>Measurement hold<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>\u221210 \u00b0C to +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td>\u221225 \u00b0C to +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Protection rating<\/td>\n<td>IP40<\/td>\n<\/tr>\n<tr>\n<td>Operating altitude<\/td>\n<td>Up to 2000 m<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>2 AA alkaline batteries<\/td>\n<\/tr>\n<tr>\n<td>Typical battery life<\/td>\n<td>40 hours<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>59 \u00d7 38 \u00d7 212 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>260 g<\/td>\n<\/tr>\n<tr>\n<td>Warranty<\/td>\n<td>3 years on electronics<\/td>\n<\/tr>\n<tr>\n<td>Typical applications<\/td>\n<td>Process instrumentation and automation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fluke Calibration 771 Compared with 772 and 773<\/h2>\n<p>The Fluke Calibration 771 belongs to the Fluke milliamp process clamp meter family.<\/p>\n<p>The three instruments provide different measurement and calibration functions.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Function<\/th>\n<th>Fluke 771<\/th>\n<th>Fluke 772<\/th>\n<th>Fluke 773<\/th>\n<\/tr>\n<tr>\n<td>Nonintrusive mA measurement<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>4\u201320 mA loop measurement<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Direct mA measurement through test leads<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>mA signal generation<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>mA signal simulation<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>24 V loop power<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>DC voltage measurement<\/td>\n<td>No<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>DC voltage generation<\/td>\n<td>No<\/td>\n<td>No<\/td>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The Fluke Calibration 771 is the ideal choice for users primarily requiring nonintrusive current measurement.<\/p>\n<p>For applications requiring current generation, simulation or additional process measurement functions, the Fluke 772 or Fluke 773 may be more suitable.<\/p>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable electrical measurements.<\/p>\n<p>europascal provides professional calibration services for electrical measuring instruments and industrial calibration equipment.<\/p>\n<p>When the Fluke Calibration 771 is used for process current measurements, the instrument&#8217;s accuracy and calibration status should be considered.<\/p>\n<p>Relevant measurement uncertainty contributions may include:<\/p>\n<ul>\n<li>Calibration uncertainty of the current reference<\/li>\n<li>Instrument accuracy<\/li>\n<li>Display resolution<\/li>\n<li>Measurement repeatability<\/li>\n<li>Clamp positioning<\/li>\n<li>Magnetic interference<\/li>\n<li>Ambient temperature<\/li>\n<li>Instrument stability<\/li>\n<\/ul>\n<p>The individual uncertainty contributions should be evaluated according to the applicable calibration procedure.<\/p>\n<p>For professional calibration services and metrological traceability, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Fluke Calibration 771?<\/h2>\n<p>The Fluke Calibration 771 combines accurate milliamp measurement with convenient and nonintrusive operation.<\/p>\n<p>Its ability to measure 4\u201320 mA signals without interrupting the current loop is particularly valuable in industrial environments.<\/p>\n<p>The instrument helps reduce downtime by allowing technicians to check transmitter output signals while the process remains operational.<\/p>\n<p>An accuracy of 0.2% of reading plus 2 counts in the primary range provides reliable measurement performance.<\/p>\n<p>The detachable clamp allows measurements in confined spaces.<\/p>\n<p>The dual backlit display simplifies interpretation of current signals.<\/p>\n<p>An integrated flashlight and measurement hold function improve convenience during field operation.<\/p>\n<p>With a weight of only 260 g and a typical battery life of 40 hours, the instrument is suitable for mobile maintenance applications.<\/p>\n<p>For instrumentation technicians, automation engineers and maintenance professionals requiring a reliable milliamp clamp meter, the Fluke Calibration 771 provides an excellent combination of accuracy, portability and ease of use.<\/p>\n<p>europascal supports customers with professional measurement equipment, technical advice and calibration services.<\/p>\n<h2>Typical Applications for the Fluke Calibration 771<\/h2>\n<p>The Fluke Calibration 771 is suitable for numerous industrial measurement and maintenance applications.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>4\u201320 mA current loop measurement<\/li>\n<li>Industrial process instrumentation<\/li>\n<li>PLC analog signal testing<\/li>\n<li>Temperature transmitter troubleshooting<\/li>\n<li>Pressure transmitter troubleshooting<\/li>\n<li>Flow transmitter testing<\/li>\n<li>Level transmitter testing<\/li>\n<li>Industrial automation<\/li>\n<li>Process control systems<\/li>\n<li>Preventive maintenance<\/li>\n<li>Commissioning<\/li>\n<li>Electrical maintenance<\/li>\n<li>Instrumentation troubleshooting<\/li>\n<li>Industrial quality assurance<\/li>\n<li>Field service<\/li>\n<li>Process signal verification<\/li>\n<\/ul>\n<p>The combination of nonintrusive current measurement, excellent portability and convenient operation makes the Fluke Calibration 771 a professional solution for industrial process signal measurement.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Find more Fluke Calibration products here.<\/a><\/p>\n<p>Manufacturer information for the Fluke Calibration 771 can be found on the <a href=\"https:\/\/www.fluke.com\/en-ie\/product\/calibration-tools\/ma-loop-calibrators\/fluke-771\" target=\"_blank\" rel=\"noopener\">official Fluke website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-771-Milliamp-Process-Clamp-Meter.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke Calibration 771<\/strong> is a compact milliamp process clamp meter for measuring <strong>4\u201320 mA signals without interrupting the current loop<\/strong>.<\/p>\n<p>With <strong>0.2% accuracy<\/strong>, <strong>0.01 mA resolution<\/strong>, a detachable clamp and a backlit display, it is ideal for troubleshooting transmitters, PLC signals and industrial process instrumentation.<\/p>\n","protected":false},"featured_media":7041,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[1241,62],"product_tag":[6694,6670,6613,3918,6695,6696,4808,3922,6673,6674,6697,4761,6698,6678,6680,6699,6621,4958],"class_list":["post-7040","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-clamp-meters","product_cat-electrical","product_tag-10-bis-50-ma","product_tag-4-bis-20-ma-strommesszange","product_tag-drucktransmitter-pruefen","product_tag-elektrische-kalibrierung","product_tag-fluke-771","product_tag-fluke-calibration-771","product_tag-instandhaltung","product_tag-kalibrierlabor","product_tag-ma-clamp-meter","product_tag-ma-prozessstrommesszange","product_tag-prozessdiagnose","product_tag-prozessmesstechnik","product_tag-prozessstrommesszange","product_tag-sps-eingang-pruefen","product_tag-stromschleife-messen","product_tag-stromschleifenpruefung","product_tag-temperaturtransmitter-pruefen","product_tag-transmitter-pruefen","pa_bauart-handgeraet","pa_hart-kommunikation-nein","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/7040","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/7041"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=7040"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=7040"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=7040"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=7040"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}