{"id":7049,"date":"2026-07-17T16:21:45","date_gmt":"2026-07-17T16:21:45","guid":{"rendered":"https:\/\/europascal.de\/product\/fluke-726\/"},"modified":"2026-10-15T09:22:48","modified_gmt":"2026-10-15T09:22:48","slug":"fluke-726","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/fluke-726\/","title":{"rendered":"Fluke 726 Precise Multifunction Process Calibrator"},"content":{"rendered":"<p>The <strong>Fluke 726<\/strong> is a high-precision multifunction process calibrator designed for demanding calibration, maintenance and troubleshooting applications in industrial process instrumentation.<\/p>\n<p>Combining accurate measurement and signal generation in a compact handheld instrument, the Fluke 726 allows technicians to calibrate temperature transmitters, pressure transmitters, flowmeters, process indicators and other industrial measurement equipment.<\/p>\n<p>With basic DC measurement accuracy down to <strong>0.01%<\/strong>, two independent measurement and source channels, integrated 24 V loop power and comprehensive temperature calibration functions, the Fluke 726 provides exceptional versatility for professional field calibration.<\/p>\n<p>The instrument measures and sources electrical process signals, simulates resistance temperature detectors and thermocouples, and supports pressure calibration when connected to compatible external Fluke pressure modules.<\/p>\n<p>Advanced functions such as automatic stepping, ramp generation, transmitter error calculation and storage of calibration results simplify routine calibration procedures.<\/p>\n<p>The Fluke 726 is particularly suitable for maintenance technicians, calibration laboratories, process engineers and industrial quality assurance departments.<\/p>\n<p>europascal supports professional users with high-quality calibration equipment, technical advice and reliable metrological services.<\/p>\n<p>For additional information about traceable calibration, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The Fluke 726 combines multiple calibration functions in one portable instrument.<\/p>\n<p>Its main advantages include:<\/p>\n<ul>\n<li>High-precision multifunction process calibration<\/li>\n<li>Basic DC accuracy down to 0.01%<\/li>\n<li>Two independent measurement and source channels<\/li>\n<li>Simultaneous measurement and signal generation<\/li>\n<li>DC voltage measurement up to 30 V<\/li>\n<li>DC voltage generation up to 20 V<\/li>\n<li>Current measurement and generation up to 24 mA<\/li>\n<li>Integrated 24 V loop power supply<\/li>\n<li>Resistance measurement up to 4000 \u03a9<\/li>\n<li>RTD measurement and simulation<\/li>\n<li>Thermocouple measurement and simulation<\/li>\n<li>Frequency measurement and generation<\/li>\n<li>Pressure calibration with compatible external pressure modules<\/li>\n<li>Integrated pressure switch testing<\/li>\n<li>Automatic step and ramp functions<\/li>\n<li>Transmitter error calculation in percent<\/li>\n<li>Storage of up to eight calibration results<\/li>\n<li>Storage of frequently used instrument settings<\/li>\n<li>Configurable RTD calibration coefficients<\/li>\n<li>HART-compatible mode with selectable 250 \u03a9 resistance<\/li>\n<li>Backlit display for industrial environments<\/li>\n<li>Portable battery-powered design<\/li>\n<li>Three-year manufacturer warranty<\/li>\n<\/ul>\n<h2>Ideal for Demanding Calibration Applications<\/h2>\n<p>The <strong>Fluke 726 multifunction process calibrator<\/strong> is designed for industrial applications requiring accurate measurement and simulation of different process variables.<\/p>\n<p>Instead of using several separate instruments, technicians can perform multiple calibration tasks with one handheld device.<\/p>\n<p>Typical applications include calibration of temperature transmitters, pressure transmitters, process indicators, control valves and frequency-based measurement systems.<\/p>\n<p>The instrument is particularly useful in chemical plants, pharmaceutical manufacturing, energy production, food processing and industrial automation.<\/p>\n<p>Its dual-channel design allows technicians to generate an input signal while simultaneously measuring the output of the device under test.<\/p>\n<p>This functionality is especially valuable when calibrating transmitters that convert a physical measurement variable into a standardized electrical signal.<\/p>\n<p>For example, a temperature transmitter can be tested by simulating an RTD or thermocouple input while measuring its corresponding 4\u201320 mA output.<\/p>\n<p>The Fluke 726 therefore provides an efficient solution for calibration and troubleshooting directly at the installation site.<\/p>\n<h2>High-Precision Measurement and Signal Generation<\/h2>\n<p>The Fluke 726 provides accurate measurement and generation of electrical process signals.<\/p>\n<p>For DC voltage and current functions, the manufacturer specifies basic accuracy down to 0.01% of reading, with additional fixed terms depending on the selected range.<\/p>\n<p>The instrument supports voltage measurement up to 30 V and voltage generation up to 20 V.<\/p>\n<p>DC current can be measured, generated or simulated over a range extending to 24 mA.<\/p>\n<p>These functions allow the Fluke 726 to test industrial transmitters, indicators, controllers and other process instruments.<\/p>\n<p>The ability to measure and generate signals using separate channels reduces the need for additional measurement equipment.<\/p>\n<p>The exact accuracy depends on the selected measurement function and range.<\/p>\n<h2>Calibration of 4\u201320 mA Process Signals<\/h2>\n<p>The Fluke 726 is particularly suitable for calibrating industrial current loops.<\/p>\n<p>The 4\u201320 mA signal is widely used in process instrumentation because it allows measurement information to be transmitted reliably over long cable distances.<\/p>\n<p>The calibrator can measure current signals and generate defined current values for testing process indicators and control systems.<\/p>\n<p>Typical calibration points include 4 mA, 8 mA, 12 mA, 16 mA and 20 mA.<\/p>\n<p>These correspond to 0%, 25%, 50%, 75% and 100% of a standard linear measurement range.<\/p>\n<p>The integrated transmitter error calculation simplifies the evaluation of deviations between expected and measured signals.<\/p>\n<p>Automatic stepping and ramp functions can be used to check the linearity and response of connected instruments.<\/p>\n<h2>Integrated 24 V Loop Power Supply<\/h2>\n<p>The Fluke 726 includes an integrated 24 V DC loop power supply.<\/p>\n<p>This allows technicians to supply compatible two-wire transmitters during calibration.<\/p>\n<p>The instrument can provide loop power while simultaneously measuring the transmitter current.<\/p>\n<p>This eliminates the need for a separate power supply in many field applications.<\/p>\n<p>The function is particularly useful when testing transmitters that have been disconnected from their normal process control system.<\/p>\n<p>Technicians can connect the transmitter directly to the calibrator and verify its electrical output.<\/p>\n<h2>RTD Measurement and Simulation<\/h2>\n<p>The Fluke 726 supports the measurement and simulation of resistance temperature detectors.<\/p>\n<p>RTDs are widely used for accurate temperature measurement in industrial processes.<\/p>\n<p>The calibrator supports common platinum resistance thermometer characteristics and additional RTD types.<\/p>\n<p>It also allows users to enter custom RTD calibration coefficients.<\/p>\n<p>This is particularly useful when working with individually calibrated resistance thermometers.<\/p>\n<p>In simulation mode, the Fluke 726 reproduces the electrical resistance corresponding to a selected temperature.<\/p>\n<p>This allows RTD transmitters and temperature indicators to be calibrated without connecting a physical temperature sensor.<\/p>\n<p>In measurement mode, the instrument evaluates the resistance of a connected RTD and displays the corresponding temperature.<\/p>\n<p>The supported temperature range depends on the selected RTD characteristic.<\/p>\n<h2>Thermocouple Measurement and Simulation<\/h2>\n<p>The Fluke 726 also supports thermocouple measurement and simulation.<\/p>\n<p>Supported thermocouple types include common industrial characteristics such as J, K, T, E, N, R, S and B, as well as additional types.<\/p>\n<p>Thermocouples are frequently used for temperature measurement in industrial furnaces, heating systems, process plants and manufacturing equipment.<\/p>\n<p>The Fluke 726 can measure thermocouple signals and convert them into temperature values.<\/p>\n<p>It can also generate thermocouple-equivalent signals to test temperature transmitters and indicators.<\/p>\n<p>This allows the electrical temperature measurement chain to be verified without requiring an external temperature source.<\/p>\n<p>For accurate thermocouple calibration, the reference junction compensation and the selected thermocouple characteristic must be considered.<\/p>\n<h2>Pressure Calibration with External Modules<\/h2>\n<p>The Fluke 726 supports pressure measurement and calibration when connected to compatible external Fluke pressure modules.<\/p>\n<p>Pressure modules are available for different pressure types and measurement ranges.<\/p>\n<p>Depending on the selected module, the system can be used for gauge, differential, absolute and vacuum pressure measurements.<\/p>\n<p>The pressure measurement accuracy depends on the connected pressure module.<\/p>\n<p>The Fluke 726 can simultaneously measure pressure and generate or measure electrical signals.<\/p>\n<p>This is particularly useful when calibrating pressure transmitters with 4\u201320 mA outputs.<\/p>\n<p>For example, a defined pressure can be applied using an external pressure source while the transmitter output is measured.<\/p>\n<p><strong>Important:<\/strong> The Fluke 726 does not contain an integrated pressure generator. Pressure modules and suitable pressure sources are required separately.<\/p>\n<h2>Integrated Pressure Switch Testing<\/h2>\n<p>The Fluke 726 includes a pressure switch test function.<\/p>\n<p>This function allows technicians to determine the switching characteristics of pressure switches.<\/p>\n<p>The instrument can record the switching point and reset point.<\/p>\n<p>The difference between these values represents the switching deadband.<\/p>\n<p>This functionality is particularly useful during maintenance and commissioning of industrial pressure switches.<\/p>\n<p>A compatible external pressure module and pressure source are required.<\/p>\n<h2>Frequency Measurement and Generation<\/h2>\n<p>The Fluke 726 supports frequency measurement and signal generation.<\/p>\n<p>Frequency signals are commonly used in flow measurement, rotational speed measurement and industrial automation.<\/p>\n<p>The calibrator can generate defined frequency signals for testing compatible instruments.<\/p>\n<p>It can also measure frequency signals from connected devices.<\/p>\n<p>Additional frequency functions support flowmeter testing, including frequency totalization and pulse train generation.<\/p>\n<p>These capabilities make the Fluke 726 suitable for checking frequency-based process instrumentation.<\/p>\n<h2>Automatic Step and Ramp Functions<\/h2>\n<p>The Fluke 726 includes automatic step and ramp functions.<\/p>\n<p>These functions simplify repetitive calibration procedures.<\/p>\n<p>Automatic stepping allows the calibrator to generate predefined signal levels.<\/p>\n<p>This is particularly useful when testing transmitters and indicators at multiple calibration points.<\/p>\n<p>Ramp generation produces a continuously changing output signal.<\/p>\n<p>This allows technicians to observe the response of connected instruments over a defined measurement range.<\/p>\n<p>Both functions help reduce manual operation and improve calibration efficiency.<\/p>\n<h2>Transmitter Error Calculation<\/h2>\n<p>The Fluke 726 can calculate transmitter error directly.<\/p>\n<p>This allows technicians to evaluate calibration results without using an external calculator.<\/p>\n<p>The instrument compares the expected transmitter output with the measured value.<\/p>\n<p>The deviation can be displayed as a percentage.<\/p>\n<p>This simplifies the evaluation of transmitter performance during maintenance and calibration.<\/p>\n<p>The function is particularly useful when testing linear 4\u201320 mA transmitters.<\/p>\n<h2>Storage of Calibration Results<\/h2>\n<p>The Fluke 726 can store up to eight calibration results.<\/p>\n<p>This allows technicians to record measurement information during field calibration.<\/p>\n<p>Stored results can be reviewed later for analysis.<\/p>\n<p>The instrument also supports storage of frequently used measurement configurations.<\/p>\n<p>This reduces setup time when performing recurring calibration tasks.<\/p>\n<p>The Fluke 726 is not a full documenting process calibrator with integrated HART communication.<\/p>\n<p>For applications requiring more extensive documentation and HART communication, the Fluke 754 provides additional functionality.<\/p>\n<h2>HART-Compatible Measurement Mode<\/h2>\n<p>The Fluke 726 includes a selectable 250 \u03a9 resistance for compatibility with HART instrumentation.<\/p>\n<p>This function can be useful when measuring or generating current signals in HART-equipped process loops.<\/p>\n<p>However, the Fluke 726 does not provide integrated HART communication or device configuration functions.<\/p>\n<p>A separate HART communicator is required when digital communication with HART devices is necessary.<\/p>\n<h2>Technical Highlights<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>Fluke 726<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>Fluke<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>726<\/td>\n<\/tr>\n<tr>\n<td>Product type<\/td>\n<td>Multifunction Process Calibrator<\/td>\n<\/tr>\n<tr>\n<td>Basic DC accuracy<\/td>\n<td>Down to 0.01%<\/td>\n<\/tr>\n<tr>\n<td>Measurement channels<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>DC voltage measurement<\/td>\n<td>Up to 30 V<\/td>\n<\/tr>\n<tr>\n<td>DC voltage generation<\/td>\n<td>Up to 20 V<\/td>\n<\/tr>\n<tr>\n<td>DC current measurement<\/td>\n<td>Up to 24 mA<\/td>\n<\/tr>\n<tr>\n<td>DC current generation<\/td>\n<td>Up to 24 mA<\/td>\n<\/tr>\n<tr>\n<td>Current resolution<\/td>\n<td>0.001 mA<\/td>\n<\/tr>\n<tr>\n<td>Resistance measurement<\/td>\n<td>Up to 4000 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Resistance simulation<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>RTD measurement<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>RTD simulation<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple measurement<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Thermocouple simulation<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Frequency measurement<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Frequency generation<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Pressure measurement<\/td>\n<td>With external pressure module<\/td>\n<\/tr>\n<tr>\n<td>Pressure generation<\/td>\n<td>External pressure source required<\/td>\n<\/tr>\n<tr>\n<td>Pressure switch testing<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Loop power supply<\/td>\n<td>24 V DC<\/td>\n<\/tr>\n<tr>\n<td>HART-compatible resistance<\/td>\n<td>250 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Automatic stepping<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Automatic ramping<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Transmitter error calculation<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Calibration result memory<\/td>\n<td>Up to 8 results<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>Backlit LCD<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer warranty<\/td>\n<td>3 years<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Calibration Service by europascal<\/h2>\n<p>Regular calibration is essential for maintaining reliable and traceable process measurements.<\/p>\n<p>europascal supports industrial customers with professional calibration equipment and calibration services for electrical, pressure and temperature measurement instruments.<\/p>\n<p>The Fluke 726 combines several measurement functions in one device. Consequently, the relevant calibration procedure must consider the individual measurement ranges and functions.<\/p>\n<p>Important calibration parameters include DC voltage measurement and generation, DC current measurement and generation, resistance measurement and simulation, thermocouple measurement and simulation, and frequency measurement and generation.<\/p>\n<p>When external pressure modules are used, their individual calibration and measurement uncertainty must also be considered.<\/p>\n<p>The manufacturer&#8217;s accuracy specifications must not be confused with the expanded measurement uncertainty stated on a calibration certificate.<\/p>\n<p>For professional metrological services and traceable calibration, visit the <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal Calibration Service<\/a>.<\/p>\n<h2>Why Choose the Fluke 726?<\/h2>\n<p>The Fluke 726 combines accurate electrical measurement, signal generation and process calibration functions in one compact handheld instrument.<\/p>\n<p>Its two independent channels allow simultaneous measurement and simulation of process signals.<\/p>\n<p>The basic accuracy of 0.01% makes it suitable for demanding industrial calibration applications.<\/p>\n<p>Integrated RTD and thermocouple functions allow technicians to test temperature transmitters without requiring separate temperature simulation instruments.<\/p>\n<p>Compatibility with external pressure modules extends the instrument&#8217;s capabilities to pressure calibration.<\/p>\n<p>The integrated 24 V loop power supply simplifies testing of two-wire transmitters.<\/p>\n<p>Automatic stepping, ramp generation and transmitter error calculation reduce manual work during calibration.<\/p>\n<p>The ability to store calibration results and frequently used settings further improves efficiency.<\/p>\n<p>For industrial maintenance technicians, calibration laboratories and process engineers, the Fluke 726 provides a versatile and reliable solution for professional process calibration.<\/p>\n<h2>Typical Calibration Applications with the Fluke 726<\/h2>\n<p>The Fluke 726 is suitable for a wide range of industrial calibration applications.<\/p>\n<p>Typical applications include calibration of pressure transmitters, temperature transmitters, process indicators, RTDs, thermocouples, frequency-based flowmeters and control system inputs.<\/p>\n<p>The instrument can also be used for testing current loops, checking transmitter linearity and troubleshooting industrial measurement systems.<\/p>\n<p>Its portable construction makes it particularly suitable for maintenance work directly at the installation site.<\/p>\n<p>In calibration laboratories, the Fluke 726 can be used as a multifunction electrical reference and signal source for process instrumentation.<\/p>\n<p>The combination of accurate measurement functions, signal simulation, pressure module compatibility and automated test functions makes the Fluke 726 an efficient solution for industrial calibration and maintenance.<\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/fluke-calibration\/\">Find more Fluke Calibration products here.<\/a><\/p>\n<p>Manufacturer information for the Fluke 726 can be found on the <a href=\"https:\/\/www.fluke.com\/en-gb\/product\/calibration-tools\/multifunction-calibrators\/fluke-726\" target=\"_blank\" rel=\"noopener\">official Fluke website<\/a>.<\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/Fluke-726-Precision-Multifunctions-Process-Calibrator.pdf\"> <span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>Fluke 726<\/strong> is a precision multifunction process calibrator with <strong>0.01% basic DC accuracy<\/strong> and two independent channels. It measures and simulates voltage, current, RTDs, thermocouples and frequency signals.<\/p>\n<p>Featuring integrated <strong>24 V loop power<\/strong>, automatic step and ramp functions, and pressure calibration with optional external modules, it is ideal for industrial maintenance, transmitter calibration and field applications.<\/p>\n","protected":false},"featured_media":7050,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[4582],"product_cat":[62,64],"product_tag":[5721,4744,4201,4203,3918,5808,6723,6724,3921,6725,4808,3922,4811,4760,4761,4750,4752,6620,4002,3929],"class_list":["post-7049","product","type-product","status-publish","has-post-thumbnail","product_brand-fluke-2","product_cat-electrical","product_cat-process-multifunction-calibrators","product_tag-24-v-loop-power","product_tag-4-bis-20-ma-kalibrator","product_tag-druckkalibrator","product_tag-drucktransmitter-kalibrieren","product_tag-elektrische-kalibrierung","product_tag-fluke-726","product_tag-fluke-750p-druckmodule","product_tag-fluke-calibration-726","product_tag-frequenzkalibrator","product_tag-i-p-wandler-pruefen","product_tag-instandhaltung","product_tag-kalibrierlabor","product_tag-multifunktions-prozesskalibrator","product_tag-praezisions-prozesskalibrator","product_tag-prozessmesstechnik","product_tag-pt100-kalibrator","product_tag-rtd-kalibrator","product_tag-stromschleifenkalibrator","product_tag-temperaturtransmitter-kalibrieren","product_tag-thermoelement-kalibrator","pa_bauart-handgeraet","pa_hart-kommunikation-nein","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/7049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/7050"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=7049"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=7049"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=7049"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=7049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}