{"id":7174,"date":"2026-07-17T14:34:50","date_gmt":"2026-07-17T14:34:50","guid":{"rendered":"https:\/\/europascal.de\/product\/europascal-bh2-6000b\/"},"modified":"2026-10-21T11:02:22","modified_gmt":"2026-10-21T11:02:22","slug":"europascal-bh2-6000b","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/europascal-bh2-6000b\/","title":{"rendered":"europascal BH2-6000B Precise Hydraulic Deadweight Tester"},"content":{"rendered":"<p>The <strong>europascal BH2-6000B Hydraulic Deadweight Tester<\/strong> is a high-performance hydraulic pressure standard developed for precise calibration at extremely high pressures. With a measuring range from <strong>200 to 6,000 bar<\/strong> and a standard accuracy of <strong>0.05 % of reading<\/strong>, the BH2-6000B is designed for professional calibration laboratories, high-pressure measurement applications, research facilities and industrial quality assurance.<\/p>\n<p>For particularly demanding applications, AREMECA specifies an enhanced accuracy of <strong>up to 0.02 % of reading on request<\/strong>.<\/p>\n<p>The BH2-6000B is a <strong>single-piston deadweight tester<\/strong>. Both the piston and cylinder are manufactured from <strong>tungsten carbide<\/strong>, providing the mechanical properties required for pressure generation up to <strong>6,000 bar \/ 600 MPa<\/strong>.<\/p>\n<p>The instrument operates hydraulically with oil and uses calibrated stainless steel masses to generate a precisely defined force on the piston. The resulting reference pressure is based on the fundamental physical relationship between force and effective piston area.<\/p>\n<p>Unlike the automatic BH4-6000B, the BH2-6000B is configured as a manually operated high-performance pressure balance in its standard configuration. Motorization, piston position visualization and automatic pressure calculation can be added as options.<\/p>\n<p>europascal provides professional support for high-pressure calibration equipment, including system configuration, maintenance and calibration. The <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal calibration service<\/a> provides calibration solutions for deadweight testers, pressure balances, pressure gauges, pressure sensors, pressure transmitters and other pressure measuring equipment.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The <strong>europascal BH2-6000B Hydraulic Deadweight Tester<\/strong> combines extremely high pressure capability with a proven physical reference principle.<\/p>\n<p>Key benefits include:<\/p>\n<ul>\n<li>High-performance hydraulic deadweight tester<\/li>\n<li>Measuring range from 200 to 6,000 bar<\/li>\n<li>Maximum pressure of 6,000 bar \/ 600 MPa<\/li>\n<li>Standard accuracy of 0.05 % of reading<\/li>\n<li>Enhanced accuracy up to 0.02 % of reading on request<\/li>\n<li>Single-piston configuration<\/li>\n<li>One precision piston-cylinder system<\/li>\n<li>Tungsten carbide piston<\/li>\n<li>Tungsten carbide cylinder<\/li>\n<li>Hydraulic operation with oil<\/li>\n<li>Stainless steel calibration masses<\/li>\n<li>Standard or customer-specific local gravity<\/li>\n<li>Manual operation in standard configuration<\/li>\n<li>Optional motorized mass rotation<\/li>\n<li>Optional piston position visualization<\/li>\n<li>Optional automatic pressure calculation<\/li>\n<li>Optional environmental sensors<\/li>\n<li>Optional computer data transfer<\/li>\n<li>Designed for professional high-pressure calibration<\/li>\n<\/ul>\n<h2>Extreme Pressure Range from 200 to 6,000 bar<\/h2>\n<p>The <strong>europascal BH2-6000B<\/strong> covers a hydraulic measuring range from:<\/p>\n<p><strong>200 to 6,000 bar<\/strong><\/p>\n<p>This corresponds to:<\/p>\n<p><strong>20,000 to 600,000 kPa<\/strong><\/p>\n<p>or:<\/p>\n<p><strong>20 to 600 MPa<\/strong><\/p>\n<p>The manufacturer specifies the imperial range as:<\/p>\n<p><strong>2,000 to 80,000 psi<\/strong><\/p>\n<p>The maximum pressure is:<\/p>\n<p><strong>6,000 bar \/ 600 MPa<\/strong><\/p>\n<p>This exceptionally high pressure capability makes the BH2-6000B suitable for calibrating specialized high-pressure instruments that are far beyond the range of conventional hydraulic deadweight testers.<\/p>\n<h2>Accuracy of 0.05 % of Reading<\/h2>\n<p>The standard accuracy of the <strong>europascal BH2-6000B<\/strong> is:<\/p>\n<p><strong>0.05 % of reading<\/strong><\/p>\n<p>For more demanding applications, AREMECA specifies:<\/p>\n<p><strong>up to 0.02 % of reading on request<\/strong><\/p>\n<p>The distinction between standard and optional performance is important when configuring the pressure balance for a specific calibration laboratory.<\/p>\n<p>At pressures extending to 6,000 bar, the complete measurement uncertainty is influenced by several quantities.<\/p>\n<p>Relevant contributions can include:<\/p>\n<ul>\n<li>Calibration of the mass set<\/li>\n<li>Effective piston area<\/li>\n<li>Pressure coefficient<\/li>\n<li>Pressure deformation<\/li>\n<li>Piston-cylinder temperature<\/li>\n<li>Local gravitational acceleration<\/li>\n<li>Air buoyancy<\/li>\n<li>Hydraulic fluid properties<\/li>\n<li>Hydrostatic head<\/li>\n<li>Repeatability<\/li>\n<li>Sensitivity<\/li>\n<li>Resolution and stability of the device under test<\/li>\n<\/ul>\n<p>The exact uncertainty budget depends on the calibration configuration and procedure.<\/p>\n<h2>Physical Piston Gauge Measurement Principle<\/h2>\n<p>The <strong>europascal BH2-6000B<\/strong> operates according to the proven physical principle of a piston gauge.<\/p>\n<p>The fundamental relationship is:<\/p>\n<p><strong>p = F \/ A<\/strong><\/p>\n<p>where:<\/p>\n<p><strong>p<\/strong> = generated pressure<br \/>\n<strong>F<\/strong> = force acting on the piston<br \/>\n<strong>A<\/strong> = effective piston area<\/p>\n<p>The force generated by the calibration masses is primarily determined by:<\/p>\n<p><strong>F = m \u00d7 g<\/strong><\/p>\n<p>where:<\/p>\n<p><strong>m<\/strong> = applied mass<br \/>\n<strong>g<\/strong> = gravitational acceleration<\/p>\n<p>The simplified relationship is therefore:<\/p>\n<p><strong>p = (m \u00d7 g) \/ A<\/strong><\/p>\n<p>For precision calibration, the actual calculation includes the relevant corrections and calibrated characteristics of the piston-cylinder system and mass set.<\/p>\n<p>At pressures up to 6,000 bar, the pressure-dependent behavior of the piston-cylinder system is particularly important.<\/p>\n<h2>Single-Piston Configuration<\/h2>\n<p>The <strong>europascal BH2-6000B<\/strong> is explicitly specified as a:<\/p>\n<p><strong>single-piston deadweight tester<\/strong><\/p>\n<p>The instrument uses:<\/p>\n<p><strong>1 piston<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>1 piston-cylinder system<\/strong><\/p>\n<p>to cover its specified high-pressure measuring range.<\/p>\n<p>This provides a straightforward high-pressure reference system without switching between separate piston assemblies within the specified range.<\/p>\n<h2>Tungsten Carbide Piston and Cylinder<\/h2>\n<p>A particularly important feature of the BH2-6000B is the material used for its piston-cylinder assembly.<\/p>\n<p>AREMECA specifies:<\/p>\n<p><strong>Piston: tungsten carbide<\/strong><\/p>\n<p><strong>Cylinder: tungsten carbide<\/strong><\/p>\n<p>Tungsten carbide provides very high hardness and excellent dimensional stability, properties that are especially important in piston-cylinder systems operating at extremely high hydraulic pressures.<\/p>\n<p>At pressures approaching 6,000 bar, mechanical deformation of the piston-cylinder assembly becomes a significant metrological consideration.<\/p>\n<p>The piston-cylinder design and its calibrated characteristics are therefore central to the performance of the pressure balance.<\/p>\n<h2>Hydraulic Operation with Oil<\/h2>\n<p>The <strong>europascal BH2-6000B<\/strong> operates hydraulically with:<\/p>\n<p><strong>oil<\/strong><\/p>\n<p>The hydraulic medium transmits the pressure generated by the pressure generator to the piston-cylinder system and the connected device under test.<\/p>\n<p>Correct filling, venting and cleanliness of the hydraulic circuit are important for reliable operation.<\/p>\n<p>All connected tubing, fittings, adapters and devices must be specifically rated for the intended high pressure.<\/p>\n<p>At pressures up to 6,000 bar, suitable high-pressure components and appropriate safety procedures are essential.<\/p>\n<h2>Stainless Steel Calibration Masses<\/h2>\n<p>The BH2 series uses calibrated:<\/p>\n<p><strong>stainless steel masses<\/strong><\/p>\n<p>The mass set generates the force acting on the piston.<\/p>\n<p>The manufacturer offers weight sets marked according to the selected pressure unit, such as:<\/p>\n<ul>\n<li>bar<\/li>\n<li>kPa<\/li>\n<li>psi<\/li>\n<li>kg\/cm\u00b2<\/li>\n<\/ul>\n<p>The calibrated mass values, together with the effective piston area and gravitational acceleration, form the physical basis of the generated reference pressure.<\/p>\n<h2>Standard or Local Gravity<\/h2>\n<p>The force generated by the calibration masses depends directly on gravitational acceleration.<\/p>\n<p>The conventional standard value is:<\/p>\n<p><strong>g = 9.80665 m\/s\u00b2<\/strong><\/p>\n<p>AREMECA allows the pressure balance to be configured for standard gravity or a specified local gravity value.<\/p>\n<p>This is important for precision pressure calibration because a relative difference in gravitational acceleration directly affects the force generated by the mass set.<\/p>\n<h2>Manual Operation as Standard<\/h2>\n<p>The <strong>europascal BH2-6000B<\/strong> belongs to the BH2 high-performance deadweight tester series.<\/p>\n<p>In its standard configuration, the mass and piston system is operated manually.<\/p>\n<p>This provides a robust physical pressure standard with a straightforward operating concept.<\/p>\n<p>For laboratories requiring additional operator assistance or automation, the BH2-6000B can be expanded with dedicated options.<\/p>\n<h2>Optional OP0004 Motorization<\/h2>\n<p>The <strong>OP0004<\/strong> option adds:<\/p>\n<ul>\n<li>Motorized rotation of the masses<\/li>\n<li>Piston position visualization<\/li>\n<li>Indicator lights for operator assistance<\/li>\n<\/ul>\n<p>Rotation of the piston and mass system helps reduce friction effects and supports free movement of the piston.<\/p>\n<p>Motorization is particularly useful for repetitive calibration procedures and reduces manual intervention.<\/p>\n<p>With OP0004, the instrument weight without the calibration masses increases from approximately <strong>22 kg to 24 kg<\/strong>.<\/p>\n<h2>Optional OP0301 Calculator Module<\/h2>\n<p>For a higher level of automation, the BH2-6000B can be equipped with:<\/p>\n<p><strong>OP0301<\/strong><\/p>\n<p>This option adds functions such as:<\/p>\n<ul>\n<li>Motorization<\/li>\n<li>Dynamic piston position visualization<\/li>\n<li>Environmental sensors<\/li>\n<li>Calculator module<\/li>\n<li>Automatic pressure calculation<\/li>\n<li>Automatic display of generated pressure<\/li>\n<li>Calibration data traceability<\/li>\n<li>Computer data transfer<\/li>\n<\/ul>\n<p>The calculator can use relevant parameters to determine the pressure generated by the deadweight tester.<\/p>\n<p>This significantly reduces manual calculation work and allows the BH2-6000B to be incorporated into digitally supported calibration workflows.<\/p>\n<h2>Operating Temperature<\/h2>\n<p>AREMECA specifies an operating temperature range of:<\/p>\n<p><strong>18 to 28 \u00b0C<\/strong><\/p>\n<p>Temperature is an important influence quantity for a precision piston gauge because thermal expansion affects the effective dimensions of the piston-cylinder system.<\/p>\n<p>For high-quality calibration, the actual piston-cylinder temperature must therefore be appropriately considered.<\/p>\n<h2>Technical Highlights<\/h2>\n<p><strong>Model:<\/strong> europascal BH2-6000B<\/p>\n<p><strong>Device type:<\/strong> High-Performance Hydraulic Deadweight Tester<\/p>\n<p><strong>Configuration:<\/strong> Single piston<\/p>\n<p><strong>Number of pistons:<\/strong> 1<\/p>\n<p><strong>Measuring range:<\/strong> 200 to 6,000 bar<\/p>\n<p><strong>Measuring range:<\/strong> 20 to 600 MPa<\/p>\n<p><strong>Measuring range:<\/strong> 20,000 to 600,000 kPa<\/p>\n<p><strong>Manufacturer pressure range:<\/strong> 2,000 to 80,000 psi<\/p>\n<p><strong>Maximum pressure:<\/strong> 6,000 bar \/ 600 MPa<\/p>\n<p><strong>Standard accuracy:<\/strong> 0.05 % of reading<\/p>\n<p><strong>Enhanced accuracy:<\/strong> Up to 0.02 % of reading on request<\/p>\n<p><strong>Piston material:<\/strong> Tungsten carbide<\/p>\n<p><strong>Cylinder material:<\/strong> Tungsten carbide<\/p>\n<p><strong>Pressure medium:<\/strong> Oil<\/p>\n<p><strong>Calibration masses:<\/strong> Stainless steel<\/p>\n<p><strong>Operating temperature:<\/strong> 18 to 28 \u00b0C<\/p>\n<p><strong>Standard gravity:<\/strong> 9.80665 m\/s\u00b2<\/p>\n<p><strong>Local gravity:<\/strong> Available<\/p>\n<p><strong>Standard operation:<\/strong> Manual<\/p>\n<p><strong>Motorization:<\/strong> Optional<\/p>\n<p><strong>Automatic pressure calculation:<\/strong> Optional<\/p>\n<p><strong>Computer data transfer:<\/strong> Optional<\/p>\n<h2>Technical Data<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>europascal BH2-6000B<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>europascal Aremeca<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>BH2-6000B<\/td>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>Hydraulic Deadweight Tester<\/td>\n<\/tr>\n<tr>\n<td>Configuration<\/td>\n<td>Single piston<\/td>\n<\/tr>\n<tr>\n<td>Number of pistons<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>200\u20136,000 bar<\/td>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>20\u2013600 MPa<\/td>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>20,000\u2013600,000 kPa<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer psi range<\/td>\n<td>2,000\u201380,000 psi<\/td>\n<\/tr>\n<tr>\n<td>Maximum pressure<\/td>\n<td>6,000 bar \/ 600 MPa<\/td>\n<\/tr>\n<tr>\n<td>Standard accuracy<\/td>\n<td>0.05 % of reading<\/td>\n<\/tr>\n<tr>\n<td>Enhanced accuracy<\/td>\n<td>Up to 0.02 % on request<\/td>\n<\/tr>\n<tr>\n<td>Pressure medium<\/td>\n<td>Oil<\/td>\n<\/tr>\n<tr>\n<td>Piston material<\/td>\n<td>Tungsten carbide<\/td>\n<\/tr>\n<tr>\n<td>Cylinder material<\/td>\n<td>Tungsten carbide<\/td>\n<\/tr>\n<tr>\n<td>Calibration masses<\/td>\n<td>Stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>18\u201328 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Standard gravity<\/td>\n<td>9.80665 m\/s\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Device weight without masses<\/td>\n<td>Approx. 22 kg<\/td>\n<\/tr>\n<tr>\n<td>Weight with OP0004\/OP0301<\/td>\n<td>Approx. 24 kg<\/td>\n<\/tr>\n<tr>\n<td>Standard operation<\/td>\n<td>Manual<\/td>\n<\/tr>\n<tr>\n<td>Motorization<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Automatic pressure calculation<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Data transfer<\/td>\n<td>Optional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>BH2-6000B vs. BH4-6000B<\/h2>\n<p>The europascal Aremeca portfolio includes both the <strong>BH2-6000B<\/strong> and the <strong>BH4-6000B<\/strong> for extremely high hydraulic pressures.<\/p>\n<p>The main difference is the level of integrated automation.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>BH2-6000B<\/th>\n<th>BH4-6000B<\/th>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>200\u20136,000 bar<\/td>\n<td>200\u20136,000 bar<\/td>\n<\/tr>\n<tr>\n<td>Maximum pressure<\/td>\n<td>6,000 bar<\/td>\n<td>6,000 bar<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>0.05 %<\/td>\n<td>0.05 %<\/td>\n<\/tr>\n<tr>\n<td>Piston configuration<\/td>\n<td>Single piston<\/td>\n<td>Single piston<\/td>\n<\/tr>\n<tr>\n<td>Standard operation<\/td>\n<td>Manual<\/td>\n<td>Automatic<\/td>\n<\/tr>\n<tr>\n<td>Motorized operation<\/td>\n<td>Optional<\/td>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<td>Piston position visualization<\/td>\n<td>Optional<\/td>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<td>Automatic pressure calculation<\/td>\n<td>Optional<\/td>\n<td>Integrated<\/td>\n<\/tr>\n<tr>\n<td>Computer data functions<\/td>\n<td>Optional<\/td>\n<td>Integrated<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The <strong>BH2-6000B<\/strong> is particularly suitable when a robust manually operated physical pressure standard is preferred.<\/p>\n<p>With options such as OP0004 or OP0301, additional motorization and calculation functionality can be added.<\/p>\n<p>The <strong>BH4-6000B<\/strong> is the alternative when these automatic functions are required as an integral part of the standard instrument configuration.<\/p>\n<h2>Position within the BH2 High-Pressure Series<\/h2>\n<p>The BH2 series provides several models for extremely high hydraulic pressure calibration.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<th>Measuring Range<\/th>\n<th>Accuracy<\/th>\n<\/tr>\n<tr>\n<td>BH2-2000B<\/td>\n<td>40\u20132,000 bar<\/td>\n<td>0.02 %<\/td>\n<\/tr>\n<tr>\n<td>BH2-2500B<\/td>\n<td>40\u20132,500 bar<\/td>\n<td>0.02 %<\/td>\n<\/tr>\n<tr>\n<td>BH2-3000B<\/td>\n<td>40\u20133,000 bar<\/td>\n<td>0.02 %<\/td>\n<\/tr>\n<tr>\n<td>BH2-4000B<\/td>\n<td>40\u20134,000 bar<\/td>\n<td>0.02 %<\/td>\n<\/tr>\n<tr>\n<td>BH2-5000B<\/td>\n<td>40\u20135,000 bar<\/td>\n<td>0.02 %<\/td>\n<\/tr>\n<tr>\n<td><strong>BH2-6000B<\/strong><\/td>\n<td><strong>200\u20136,000 bar<\/strong><\/td>\n<td><strong>0.05 %<\/strong><\/td>\n<\/tr>\n<tr>\n<td>BH2-7000B<\/td>\n<td>200\u20137,000 bar<\/td>\n<td>0.05 %<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The BH2-6000B therefore marks the transition into the particularly high-pressure section of the product family.<\/p>\n<p>Its lower pressure limit is 200 bar, while its maximum pressure reaches 6,000 bar.<\/p>\n<h2>Typical Calibration Applications<\/h2>\n<p>The <strong>europascal BH2-6000B Hydraulic Deadweight Tester<\/strong> is designed for comparison testing, adjustment and calibration of mechanical and electronic pressure measuring instruments.<\/p>\n<p>Typical devices under test include:<\/p>\n<ul>\n<li>High-pressure gauges<\/li>\n<li>Digital pressure gauges<\/li>\n<li>High-pressure sensors<\/li>\n<li>Pressure transducers<\/li>\n<li>Pressure transmitters<\/li>\n<li>Pressure switches<\/li>\n<li>Reference pressure instruments<\/li>\n<li>Hydraulic high-pressure measurement systems<\/li>\n<li>Specialized high-pressure test equipment<\/li>\n<\/ul>\n<p>Typical users include calibration laboratories, pressure instrument manufacturers, high-pressure component manufacturers, research institutes, industrial quality assurance departments and specialized test facilities.<\/p>\n<h2>Calibration and Traceability<\/h2>\n<p>A high-pressure deadweight tester is a physical reference standard and should be regularly calibrated according to its use and metrological requirements.<\/p>\n<p>Important components and parameters include:<\/p>\n<ul>\n<li>Piston-cylinder assembly<\/li>\n<li>Effective piston area<\/li>\n<li>Pressure deformation characteristics<\/li>\n<li>Calibration mass set<\/li>\n<li>Gravity value<\/li>\n<li>Temperature behavior<\/li>\n<li>Repeatability<\/li>\n<li>Sensitivity<\/li>\n<\/ul>\n<p>The <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal calibration service<\/a> provides professional calibration services for pressure balances, deadweight testers, pressure gauges, sensors, transmitters and other pressure measuring equipment.<\/p>\n<p>europascal can also provide support with maintenance, system configuration and selection of suitable high-pressure calibration equipment.<\/p>\n<h2>Why Choose the europascal BH2-6000B?<\/h2>\n<p>The <strong>europascal BH2-6000B Precise Hydraulic Deadweight Tester<\/strong> provides a physical pressure reference for extremely demanding applications from 200 to 6,000 bar.<\/p>\n<p>Its single-piston design uses a tungsten carbide piston and tungsten carbide cylinder for operation at pressures up to 600 MPa.<\/p>\n<p>With a standard accuracy of 0.05 % of reading and enhanced performance up to 0.02 % on request, the BH2-6000B provides a powerful solution for professional high-pressure metrology.<\/p>\n<p>The standard manually operated configuration provides a robust and straightforward pressure standard. Optional motorization, piston position visualization and automatic pressure calculation allow the system to be expanded according to laboratory requirements.<\/p>\n<p>For laboratories that require reliable physical pressure generation up to 6,000 bar without the fully automatic configuration of the BH4 series, the BH2-6000B provides an excellent combination of pressure capability, flexibility and metrological performance.<\/p>\n<p><strong>Looking for the europascal BH2-6000B or a hydraulic pressure calibration solution up to 6,000 bar? Contact europascal for expert advice, system configuration and professional calibration services tailored to your requirements.<\/strong><\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/aremeca-europascal\/\">Further products from europascal Aremeca can be found here.<\/a><\/p>\n<p><a href=\"https:\/\/en.aremeca-instrumentation.com\/\" target=\"_blank\" rel=\"noopener\">Manufacturer information about the europascal BH2-6000B can be found on the official Aremeca Instrumentation website.<\/a><\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/europascal-bh2-6000b-deadweight-tester-hydraulic.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>europascal BH2-6000B Hydraulic Deadweight Tester<\/strong> is a high-performance single-piston pressure standard for extreme hydraulic pressure calibration from <strong>200 to 6,000 bar (600 MPa)<\/strong>. It provides a standard accuracy of <strong>0.05 % of reading<\/strong>, with enhanced accuracy <strong>up to 0.02 % on request<\/strong>. The tungsten carbide piston and cylinder, hydraulic oil operation and optional motorization, piston position visualization and automatic pressure calculation make the BH2-6000B ideal for professional high-pressure calibration laboratories.<\/p>\n","protected":false},"featured_media":3095,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[94],"product_cat":[667,45],"product_tag":[7009,7010,4527,4528,7011,4225,4202,4203,7012,7006,4514,7013,4255,4313,4314,4516,4517,3922,4519,4535,6871,7014],"class_list":["post-7174","product","type-product","status-publish","has-post-thumbnail","product_brand-aremeca-europascal","product_cat-deadweight-tester","product_cat-pressure","product_tag-80000-psi","product_tag-aremeca-bh2-6000b","product_tag-aremeca-instrumentation","product_tag-automatische-druckberechnung","product_tag-bh2-6000b","product_tag-druckkalibrierung","product_tag-drucksensor-kalibrieren","product_tag-drucktransmitter-kalibrieren","product_tag-druckwaage-600-mpa","product_tag-druckwaage-6000-bar","product_tag-europascal-aremeca","product_tag-europascal-bh2-6000b","product_tag-hochdruckkalibrator","product_tag-hochdruckkalibrierung","product_tag-hochdruckmanometer-kalibrieren","product_tag-hochdruckwaage","product_tag-hydraulische-druckwaage","product_tag-kalibrierlabor","product_tag-kolbenmanometer","product_tag-referenznormal-druck","product_tag-wolframkarbid-kolben","product_tag-wolframkarbid-zylinder","pa_druckbereich-200-bis-6000-bar","pa_genauigkeit-0-05-vom-messwert-bis-0-008-auf-anfrage","pa_koben-zylindereinheit-einzelkolben","pa_medium-oel","pa_motorisierung-manuelle-drehung-der-gewichte","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/7174","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3095"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=7174"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=7174"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=7174"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=7174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}