{"id":7253,"date":"2026-07-17T14:34:47","date_gmt":"2026-07-17T14:34:47","guid":{"rendered":"https:\/\/europascal.de\/product\/europascal-bh2-5000b\/"},"modified":"2026-10-22T07:18:27","modified_gmt":"2026-10-22T07:18:27","slug":"europascal-bh2-5000b","status":"publish","type":"product","link":"https:\/\/europascal.de\/en\/product\/europascal-bh2-5000b\/","title":{"rendered":"europascal BH2-5000B Precise High Pressure Deadweight Tester"},"content":{"rendered":"<p>The <strong>europascal BH2-5000B High Pressure Deadweight Tester<\/strong> is a high-performance hydraulic pressure standard designed for demanding calibration applications from <strong>40 to 5,000 bar<\/strong>. With a standard accuracy of <strong>0.05 % of reading<\/strong> and enhanced performance <strong>up to 0.02 % on request<\/strong>, the BH2-5000B provides reliable physical pressure generation for professional high-pressure calibration laboratories.<\/p>\n<p>The instrument covers a pressure range from <strong>40 to 5,000 bar<\/strong>, corresponding to <strong>4 to 500 MPa<\/strong>, <strong>4,000 to 500,000 kPa<\/strong> and approximately <strong>600 to 72,000 psi<\/strong> according to the manufacturer.<\/p>\n<p>The BH2-5000B uses a <strong>single precision piston-cylinder system<\/strong>. Both the piston and cylinder are manufactured from <strong>tungsten carbide<\/strong>, providing excellent dimensional stability and wear resistance for pressure generation up to 500 MPa.<\/p>\n<p>A typical piston area of <strong>1.96315 mm\u00b2<\/strong> is specified for the BH2-5000B. The hydraulic pressure medium is <strong>sebacate oil<\/strong> with a specified density of approximately <strong>915 kg\/m\u00b3<\/strong>.<\/p>\n<p>The reference pressure is generated physically by calibrated masses acting on the precision piston-cylinder assembly. The robust BH2 platform can additionally be equipped with optional motorization, piston position visualization and automatic pressure calculation for more efficient calibration workflows.<\/p>\n<p>The <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal calibration service<\/a> provides professional calibration solutions for deadweight testers, pressure balances, pressure gauges, pressure sensors, transmitters and other pressure measuring equipment.<\/p>\n<h2>Your Benefits at a Glance<\/h2>\n<p>The <strong>europascal BH2-5000B High Pressure Deadweight Tester<\/strong> provides:<\/p>\n<ul>\n<li>Hydraulic high-pressure deadweight tester<\/li>\n<li>Measuring range from 40 to 5,000 bar<\/li>\n<li>Measuring range from 4 to 500 MPa<\/li>\n<li>Measuring range from 4,000 to 500,000 kPa<\/li>\n<li>Manufacturer range from 600 to 72,000 psi<\/li>\n<li>Standard accuracy of 0.05 % of reading<\/li>\n<li>Enhanced accuracy up to 0.02 % on request<\/li>\n<li>Single-piston configuration<\/li>\n<li>Typical piston area of 1.96315 mm\u00b2<\/li>\n<li>Tungsten carbide piston<\/li>\n<li>Tungsten carbide cylinder<\/li>\n<li>Sebacate oil as pressure medium<\/li>\n<li>Fluid density approximately 915 kg\/m\u00b3<\/li>\n<li>CH2-7000B generator base<\/li>\n<li>Instrument weight approximately 22 kg without masses<\/li>\n<li>Stainless steel calibration masses<\/li>\n<li>Standard or customer-specific gravity<\/li>\n<li>Optional motorized mass rotation<\/li>\n<li>Optional piston position visualization<\/li>\n<li>Optional automatic pressure calculation<\/li>\n<li>Optional computer data transfer<\/li>\n<\/ul>\n<h2>Measuring Range from 40 to 5,000 bar<\/h2>\n<p>The <strong>europascal BH2-5000B<\/strong> covers a hydraulic pressure range from:<\/p>\n<p><strong>40 to 5,000 bar<\/strong><\/p>\n<p>This corresponds to:<\/p>\n<p><strong>4 to 500 MPa<\/strong><\/p>\n<p>and:<\/p>\n<p><strong>4,000 to 500,000 kPa<\/strong><\/p>\n<p>The manufacturer specifies an imperial range of approximately:<\/p>\n<p><strong>600 to 72,000 psi<\/strong><\/p>\n<p>The maximum pressure is therefore:<\/p>\n<p><strong>5,000 bar \/ 500 MPa<\/strong><\/p>\n<p>This extensive range makes the BH2-5000B particularly suitable for professional laboratories working with high-pressure measuring equipment.<\/p>\n<h2>Accuracy and Metrological Performance<\/h2>\n<p>The current product information specifies a standard accuracy of:<\/p>\n<p><strong>0.05 % of reading<\/strong><\/p>\n<p>Enhanced performance is available:<\/p>\n<p><strong>up to 0.02 % on request<\/strong><\/p>\n<p>The exact metrological performance of an individual system depends on its configuration and calibration.<\/p>\n<p>The complete measurement uncertainty of an actual calibration additionally depends on the calibration certificate, operating conditions and uncertainty contributions of the complete measurement system.<\/p>\n<h2>Physical Piston Gauge Measurement Principle<\/h2>\n<p>The <strong>europascal BH2-5000B High Pressure Deadweight Tester<\/strong> operates according to the fundamental physical principle of a piston gauge.<\/p>\n<p>The basic relationship is:<\/p>\n<p><strong>p = F \/ A<\/strong><\/p>\n<p>where:<\/p>\n<p><strong>p<\/strong> = generated pressure<br \/>\n<strong>F<\/strong> = force acting on the piston<br \/>\n<strong>A<\/strong> = effective piston area<\/p>\n<p>The force generated by the calibration masses is primarily determined by:<\/p>\n<p><strong>F = m \u00d7 g<\/strong><\/p>\n<p>where:<\/p>\n<p><strong>m<\/strong> = applied mass<br \/>\n<strong>g<\/strong> = gravitational acceleration<\/p>\n<p>The simplified relationship is therefore:<\/p>\n<p><strong>p = (m \u00d7 g) \/ A<\/strong><\/p>\n<p>For precision calibration, additional corrections are applied according to the characteristics of the piston-cylinder system and the operating conditions.<\/p>\n<h2>Typical Piston Area of 1.96315 mm\u00b2<\/h2>\n<p>AREMECA specifies a typical piston area for the BH2-5000B of:<\/p>\n<p><strong>1.96315 mm\u00b2<\/strong><\/p>\n<p>The relatively small piston area allows very high pressures to be generated with a manageable mass load.<\/p>\n<p>Because:<\/p>\n<p><strong>p = F \/ A<\/strong><\/p>\n<p>a smaller effective piston area produces a higher pressure for the same applied force.<\/p>\n<p>This physical relationship is particularly important for pressure balances operating at several thousand bar.<\/p>\n<p>The calibrated effective area of the individual piston-cylinder assembly, rather than merely its nominal or typical area, is relevant for precise pressure calculation.<\/p>\n<h2>Tungsten Carbide Piston and Cylinder<\/h2>\n<p>The BH2-5000B uses:<\/p>\n<p><strong>Piston: tungsten carbide<\/strong><\/p>\n<p><strong>Cylinder: tungsten carbide<\/strong><\/p>\n<p>Tungsten carbide provides high hardness, wear resistance and dimensional stability.<\/p>\n<p>These properties are especially valuable for piston-cylinder systems operating at pressures up to:<\/p>\n<p><strong>500 MPa<\/strong><\/p>\n<p>The material selection helps provide the mechanical characteristics required for a stable and reproducible high-pressure reference.<\/p>\n<h2>Single-Piston Configuration<\/h2>\n<p>The <strong>europascal BH2-5000B<\/strong> incorporates:<\/p>\n<p><strong>one piston<\/strong><\/p>\n<p>and therefore:<\/p>\n<p><strong>one precision piston-cylinder system<\/strong><\/p>\n<p>The complete specified pressure range is generated with this single piston system.<\/p>\n<p>This provides straightforward operation without requiring the operator to switch between separate low-pressure and high-pressure piston assemblies.<\/p>\n<h2>Sebacate Oil as Pressure Medium<\/h2>\n<p>The BH2-5000B uses:<\/p>\n<p><strong>sebacate oil<\/strong><\/p>\n<p>as its hydraulic pressure medium.<\/p>\n<p>The manufacturer specifies a fluid density of approximately:<\/p>\n<p><strong>915 kg\/m\u00b3<\/strong><\/p>\n<p>The pressure medium is an important component of a high-pressure calibration system.<\/p>\n<p>Its compatibility with the device under test, fittings, seals and associated components should always be verified.<\/p>\n<p>Correct filling and venting are also essential because trapped gas can adversely affect pressure stability and settling behavior.<\/p>\n<h2>High-Pressure Calibration up to 500 MPa<\/h2>\n<p>A maximum pressure of 5,000 bar corresponds to:<\/p>\n<p><strong>500 MPa<\/strong><\/p>\n<p>At these pressure levels, the complete calibration setup must be designed for high-pressure operation.<\/p>\n<p>This includes:<\/p>\n<ul>\n<li>High-pressure tubing<\/li>\n<li>Pressure-rated fittings<\/li>\n<li>Suitable adapters<\/li>\n<li>Valves<\/li>\n<li>Seals<\/li>\n<li>Pressure generator<\/li>\n<li>Device under test<\/li>\n<li>Pressure relief and depressurization procedures<\/li>\n<\/ul>\n<p>Every pressure-containing component must be suitable for the maximum applied pressure.<\/p>\n<h2>Measurement Uncertainty Contributions<\/h2>\n<p>At pressures up to 5,000 bar, several influence quantities must be considered when evaluating measurement uncertainty.<\/p>\n<p>Important contributions can include:<\/p>\n<ul>\n<li>Calibration uncertainty of the masses<\/li>\n<li>Effective piston area<\/li>\n<li>Pressure coefficient<\/li>\n<li>Elastic deformation of the piston-cylinder system<\/li>\n<li>Local gravitational acceleration<\/li>\n<li>Air buoyancy<\/li>\n<li>Piston-cylinder temperature<\/li>\n<li>Thermal expansion<\/li>\n<li>Hydraulic fluid density<\/li>\n<li>Hydrostatic head difference<\/li>\n<li>Repeatability<\/li>\n<li>Sensitivity<\/li>\n<li>Pressure stability<\/li>\n<li>Resolution of the device under test<\/li>\n<li>Environmental conditions<\/li>\n<\/ul>\n<p>The pressure dependence of the effective piston area becomes especially relevant at very high pressures.<\/p>\n<p>The final uncertainty budget should therefore be based on the actual calibration certificate and operating conditions.<\/p>\n<h2>CH2-7000B Generator Base<\/h2>\n<p>The BH2-5000B uses the:<\/p>\n<p><strong>CH2-7000B generator base<\/strong><\/p>\n<p>The pressure generator allows the hydraulic pressure required to raise the piston and balance the applied calibration masses to be generated manually.<\/p>\n<p>The capstan transfers force to the hydraulic system and allows the operator to approach the desired equilibrium condition.<\/p>\n<p>This robust mechanical principle provides reliable operation without requiring an external electric pressure generator for standard operation.<\/p>\n<h2>Stainless Steel Calibration Masses<\/h2>\n<p>The BH2 platform uses stainless steel calibration masses.<\/p>\n<p>The masses generate the precisely defined gravitational force acting on the piston.<\/p>\n<p>Together with:<\/p>\n<ul>\n<li>Effective piston area<\/li>\n<li>Gravitational acceleration<\/li>\n<li>Environmental corrections<\/li>\n<li>Pressure-related corrections<\/li>\n<\/ul>\n<p>the calibrated mass values determine the reference pressure.<\/p>\n<p>Different mass-set configurations and engineering units can be selected according to the application.<\/p>\n<h2>Standard or Local Gravity<\/h2>\n<p>The force generated by a calibration mass depends directly on gravitational acceleration.<\/p>\n<p>The conventional standard value is:<\/p>\n<p><strong>g = 9.80665 m\/s\u00b2<\/strong><\/p>\n<p>Actual gravitational acceleration varies geographically.<\/p>\n<p>The BH2-5000B can therefore be configured for either standard gravity or a specified local gravity value.<\/p>\n<p>This is important because a relative difference in gravitational acceleration directly produces a corresponding relative difference in the force generated by the calibration masses.<\/p>\n<h2>Operating Temperature<\/h2>\n<p>AREMECA specifies an operating temperature range of:<\/p>\n<p><strong>18 to 28 \u00b0C<\/strong><\/p>\n<p>The manufacturer&#8217;s reference calibration conditions are:<\/p>\n<p><strong>Temperature: 20 \u00b0C<\/strong><\/p>\n<p><strong>Atmospheric pressure: 1013.25 hPa<\/strong><\/p>\n<p><strong>Relative humidity: 50 %<\/strong><\/p>\n<p><strong>Gravitational acceleration: 9.80665 m\/s\u00b2<\/strong><\/p>\n<p>If the pressure balance is operated under different conditions, the generated reference pressure must be calculated using the appropriate parameters and corrections.<\/p>\n<h2>Instrument Weight<\/h2>\n<p>The standard BH2-5000B weighs approximately:<\/p>\n<p><strong>22 kg without calibration masses<\/strong><\/p>\n<p>When equipped with option OP0004 or OP0301, the instrument weighs approximately:<\/p>\n<p><strong>24 kg without calibration masses<\/strong><\/p>\n<p>The complete calibration mass set adds additional weight depending on the selected configuration.<\/p>\n<h2>Optional OP0004 Motorization<\/h2>\n<p>The BH2-5000B can be equipped with:<\/p>\n<p><strong>Option OP0004<\/strong><\/p>\n<p>This provides:<\/p>\n<ul>\n<li>Motorized rotation of the calibration masses<\/li>\n<li>Visualization of piston position using indicator lights<\/li>\n<\/ul>\n<p>Rotation helps reduce friction effects between the piston and cylinder.<\/p>\n<p>Motorized rotation reduces manual intervention during calibration and provides additional convenience for repetitive calibration procedures.<\/p>\n<h2>Optional OP0301 Calculator Module<\/h2>\n<p>For more advanced calibration workflows, the <strong>europascal BH2-5000B<\/strong> can be equipped with:<\/p>\n<p><strong>Option OP0301<\/strong><\/p>\n<p>This adds functions including:<\/p>\n<ul>\n<li>Motorized operation<\/li>\n<li>Dynamic piston position visualization<\/li>\n<li>Automatic pressure calculation<\/li>\n<li>Automatic pressure display<\/li>\n<li>Consideration of temperature<\/li>\n<li>Consideration of atmospheric pressure<\/li>\n<li>Consideration of relative humidity<\/li>\n<li>Computer data transfer<\/li>\n<li>Calibration data traceability<\/li>\n<\/ul>\n<p>This allows the standard BH2 platform to be expanded toward a more automated calibration workflow.<\/p>\n<h2>Technical Highlights<\/h2>\n<p><strong>Model:<\/strong> europascal BH2-5000B<\/p>\n<p><strong>Device type:<\/strong> High Pressure Hydraulic Deadweight Tester<\/p>\n<p><strong>Configuration:<\/strong> Single piston<\/p>\n<p><strong>Number of pistons:<\/strong> 1<\/p>\n<p><strong>Measuring range:<\/strong> 40 to 5,000 bar<\/p>\n<p><strong>Measuring range:<\/strong> 4 to 500 MPa<\/p>\n<p><strong>Measuring range:<\/strong> 4,000 to 500,000 kPa<\/p>\n<p><strong>Manufacturer imperial range:<\/strong> 600 to 72,000 psi<\/p>\n<p><strong>Maximum pressure:<\/strong> 5,000 bar \/ 500 MPa<\/p>\n<p><strong>Standard accuracy:<\/strong> 0.05 % of reading<\/p>\n<p><strong>Enhanced accuracy:<\/strong> Up to 0.02 % on request<\/p>\n<p><strong>Typical piston area:<\/strong> 1.96315 mm\u00b2<\/p>\n<p><strong>Piston material:<\/strong> Tungsten carbide<\/p>\n<p><strong>Cylinder material:<\/strong> Tungsten carbide<\/p>\n<p><strong>Generator base:<\/strong> CH2-7000B<\/p>\n<p><strong>Pressure medium:<\/strong> Sebacate oil<\/p>\n<p><strong>Fluid density:<\/strong> Approx. 915 kg\/m\u00b3<\/p>\n<p><strong>Instrument weight without masses:<\/strong> Approx. 22 kg<\/p>\n<p><strong>Measurement principle:<\/strong> Piston gauge \/ deadweight tester<\/p>\n<p><strong>Operating temperature:<\/strong> 18 to 28 \u00b0C<\/p>\n<p><strong>Standard gravity:<\/strong> 9.80665 m\/s\u00b2<\/p>\n<p><strong>Local gravity:<\/strong> Available<\/p>\n<p><strong>Motorization:<\/strong> Optional OP0004 \/ OP0301<\/p>\n<p><strong>Automatic pressure calculation:<\/strong> Optional OP0301<\/p>\n<p><strong>Computer data transfer:<\/strong> Optional OP0301<\/p>\n<h2>Technical Data<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>europascal BH2-5000B<\/th>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>europascal Aremeca<\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>BH2-5000B<\/td>\n<\/tr>\n<tr>\n<td>Device type<\/td>\n<td>High Pressure Hydraulic Deadweight Tester<\/td>\n<\/tr>\n<tr>\n<td>Configuration<\/td>\n<td>Single piston<\/td>\n<\/tr>\n<tr>\n<td>Number of pistons<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>40\u20135,000 bar<\/td>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>4\u2013500 MPa<\/td>\n<\/tr>\n<tr>\n<td>Measuring range<\/td>\n<td>4,000\u2013500,000 kPa<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer imperial range<\/td>\n<td>600\u201372,000 psi<\/td>\n<\/tr>\n<tr>\n<td>Maximum pressure<\/td>\n<td>5,000 bar \/ 500 MPa<\/td>\n<\/tr>\n<tr>\n<td>Standard accuracy<\/td>\n<td>0.05 % of reading<\/td>\n<\/tr>\n<tr>\n<td>Enhanced accuracy<\/td>\n<td>Up to 0.02 % on request<\/td>\n<\/tr>\n<tr>\n<td>Typical piston area<\/td>\n<td>1.96315 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Piston material<\/td>\n<td>Tungsten carbide<\/td>\n<\/tr>\n<tr>\n<td>Cylinder material<\/td>\n<td>Tungsten carbide<\/td>\n<\/tr>\n<tr>\n<td>Generator base<\/td>\n<td>CH2-7000B<\/td>\n<\/tr>\n<tr>\n<td>Pressure medium<\/td>\n<td>Sebacate oil<\/td>\n<\/tr>\n<tr>\n<td>Fluid density<\/td>\n<td>Approx. 915 kg\/m\u00b3<\/td>\n<\/tr>\n<tr>\n<td>Weight without masses<\/td>\n<td>Approx. 22 kg<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>18\u201328 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Standard gravity<\/td>\n<td>9.80665 m\/s\u00b2<\/td>\n<\/tr>\n<tr>\n<td>Motorization<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Automatic pressure calculation<\/td>\n<td>Optional OP0301<\/td>\n<\/tr>\n<tr>\n<td>Computer data transfer<\/td>\n<td>Optional OP0301<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Position within the BH2 High-Pressure Series<\/h2>\n<p>The BH2 series provides several high-pressure configurations.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<th>Pressure Range<\/th>\n<\/tr>\n<tr>\n<td>BH2-2000B<\/td>\n<td>40\u20132,000 bar<\/td>\n<\/tr>\n<tr>\n<td>BH2-2500B<\/td>\n<td>40\u20132,500 bar<\/td>\n<\/tr>\n<tr>\n<td>BH2-3000B<\/td>\n<td>40\u20133,000 bar<\/td>\n<\/tr>\n<tr>\n<td>BH2-4000B<\/td>\n<td>40\u20134,000 bar<\/td>\n<\/tr>\n<tr>\n<td><strong>BH2-5000B<\/strong><\/td>\n<td><strong>40\u20135,000 bar<\/strong><\/td>\n<\/tr>\n<tr>\n<td>BH2-6000B<\/td>\n<td>200\u20136,000 bar<\/td>\n<\/tr>\n<tr>\n<td>BH2-7000B<\/td>\n<td>200\u20137,000 bar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The BH2-5000B is therefore particularly attractive when a laboratory requires pressure generation up to <strong>500 MPa<\/strong> while retaining a lower measuring limit of approximately <strong>40 bar<\/strong>.<\/p>\n<h2>BH2-5000B vs. BH2-7000B<\/h2>\n<p>The BH2-5000B and BH2-7000B are both designed for very high hydraulic pressures, but they cover different ranges.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Feature<\/th>\n<th>BH2-5000B<\/th>\n<th>BH2-7000B<\/th>\n<\/tr>\n<tr>\n<td>Minimum pressure<\/td>\n<td>40 bar<\/td>\n<td>200 bar<\/td>\n<\/tr>\n<tr>\n<td>Maximum pressure<\/td>\n<td>5,000 bar<\/td>\n<td>7,000 bar<\/td>\n<\/tr>\n<tr>\n<td>Maximum pressure<\/td>\n<td>500 MPa<\/td>\n<td>700 MPa<\/td>\n<\/tr>\n<tr>\n<td>Number of pistons<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Piston material<\/td>\n<td>Tungsten carbide<\/td>\n<td>Tungsten carbide<\/td>\n<\/tr>\n<tr>\n<td>Cylinder material<\/td>\n<td>Tungsten carbide<\/td>\n<td>Tungsten carbide<\/td>\n<\/tr>\n<tr>\n<td>Pressure medium<\/td>\n<td>Oil<\/td>\n<td>Oil<\/td>\n<\/tr>\n<tr>\n<td>Standard operation<\/td>\n<td>Manual<\/td>\n<td>Manual<\/td>\n<\/tr>\n<tr>\n<td>Motorization<\/td>\n<td>Optional<\/td>\n<td>Optional<\/td>\n<\/tr>\n<tr>\n<td>Automatic calculation<\/td>\n<td>Optional<\/td>\n<td>Optional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The BH2-5000B provides the broader useful range toward lower pressures, while the BH2-7000B extends the maximum pressure to 700 MPa.<\/p>\n<h2>Typical Calibration Applications<\/h2>\n<p>The <strong>europascal BH2-5000B High Pressure Deadweight Tester<\/strong> is suitable for testing, adjustment and calibration of:<\/p>\n<ul>\n<li>High-pressure gauges<\/li>\n<li>Digital pressure gauges<\/li>\n<li>High-pressure sensors<\/li>\n<li>Pressure transducers<\/li>\n<li>Pressure transmitters<\/li>\n<li>Pressure switches<\/li>\n<li>Reference pressure instruments<\/li>\n<li>Hydraulic high-pressure systems<\/li>\n<li>Industrial pressure measurement equipment<\/li>\n<\/ul>\n<p>Typical users include:<\/p>\n<ul>\n<li>Professional calibration laboratories<\/li>\n<li>Pressure instrument manufacturers<\/li>\n<li>Industrial quality assurance departments<\/li>\n<li>Research laboratories<\/li>\n<li>High-pressure technology facilities<\/li>\n<li>Calibration service organizations<\/li>\n<\/ul>\n<h2>Calibration and Traceability<\/h2>\n<p>Regular calibration of a high-pressure deadweight tester is essential for maintaining reliable metrological performance.<\/p>\n<p>Important parameters include:<\/p>\n<ul>\n<li>Effective piston area<\/li>\n<li>Pressure coefficient<\/li>\n<li>Piston-cylinder characteristics<\/li>\n<li>Calibration mass values<\/li>\n<li>Local gravitational acceleration<\/li>\n<li>Temperature<\/li>\n<li>Repeatability<\/li>\n<li>Relevant correction quantities<\/li>\n<\/ul>\n<p>AREMECA supplies the instrument with a factory calibration certificate traceable to national standards. An accredited <strong>COFRAC or DKD\/DAkkS calibration certificate<\/strong> is available as an option.<\/p>\n<p>The <a href=\"https:\/\/europascal.de\/en\/calibration-services\/\">europascal calibration service<\/a> provides professional calibration solutions for pressure balances, deadweight testers, high-pressure gauges, pressure sensors and pressure transmitters.<\/p>\n<h2>Why Choose the europascal BH2-5000B?<\/h2>\n<p>The <strong>europascal BH2-5000B Precise High Pressure Deadweight Tester<\/strong> combines a wide hydraulic pressure range from <strong>40 to 5,000 bar<\/strong> with a robust single-piston design.<\/p>\n<p>Its <strong>tungsten carbide piston and cylinder<\/strong>, typical piston area of <strong>1.96315 mm\u00b2<\/strong>, sebacate oil pressure medium and CH2-7000B pressure generator are designed for demanding high-pressure calibration applications up to 500 MPa.<\/p>\n<p>The standard BH2 platform provides robust manual operation, while optional motorization, piston position visualization, automatic pressure calculation and computer data transfer allow the instrument to be adapted to more automated laboratory workflows.<\/p>\n<p>For professional laboratories requiring a physical hydraulic pressure standard with a particularly wide range extending from tens of bar to 5,000 bar, the BH2-5000B provides an excellent combination of pressure capability, metrological performance and configurable operation.<\/p>\n<p><strong>Looking for the europascal BH2-5000B or a hydraulic high-pressure calibration solution up to 5,000 bar? Contact europascal for expert advice, system configuration and professional calibration services tailored to your requirements.<\/strong><\/p>\n<p><a href=\"https:\/\/europascal.de\/marke\/aremeca-europascal\/\">Further products from europascal Aremeca can be found here.<\/a><\/p>\n<p><a href=\"https:\/\/en.aremeca-instrumentation.com\/produit\/bh2-5000b\" target=\"_blank\" rel=\"noopener\">Manufacturer information about the europascal BH2-5000B can be found on the official Aremeca Instrumentation website.<\/a><\/p>\n<p><a class=\"download-datasheet\" href=\"#\" data-pdf=\"https:\/\/europascal.de\/wp-content\/uploads\/2026\/07\/europascal-bh2-5000b-deadweight-tester-hydraulic.pdf\"><span style=\"color: #0000ff;\"><strong><em>Download Datasheet<\/em><\/strong><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong>europascal BH2-5000B High Pressure Deadweight Tester<\/strong> is a precision single-piston hydraulic pressure standard for demanding calibration applications from <strong>40 to 5,000 bar (500 MPa)<\/strong>. It features a tungsten carbide piston and cylinder, a typical piston area of <strong>1.96315 mm\u00b2<\/strong> and sebacate oil as the pressure medium. With a standard accuracy of <strong>0.05 % of reading<\/strong> and enhanced performance <strong>up to 0.02 % on request<\/strong>, the BH2-5000B is designed for professional high-pressure calibration laboratories. Optional motorization, piston position visualization and automatic pressure calculation provide additional flexibility.<\/p>\n","protected":false},"featured_media":3095,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_members_access_role":[],"_members_access_error":""},"product_brand":[94],"product_cat":[667,45],"product_tag":[7109,7110,4527,4528,7111,4225,4202,4203,7112,6753,4514,7113,4255,4313,4314,4516,4517,3922,4519,4533,4535,6871,7014],"class_list":["post-7253","product","type-product","status-publish","has-post-thumbnail","product_brand-aremeca-europascal","product_cat-deadweight-tester","product_cat-pressure","product_tag-72000-psi","product_tag-aremeca-bh2-5000b","product_tag-aremeca-instrumentation","product_tag-automatische-druckberechnung","product_tag-bh2-5000b","product_tag-druckkalibrierung","product_tag-drucksensor-kalibrieren","product_tag-drucktransmitter-kalibrieren","product_tag-druckwaage-500-mpa","product_tag-druckwaage-5000-bar","product_tag-europascal-aremeca","product_tag-europascal-bh2-5000b","product_tag-hochdruckkalibrator","product_tag-hochdruckkalibrierung","product_tag-hochdruckmanometer-kalibrieren","product_tag-hochdruckwaage","product_tag-hydraulische-druckwaage","product_tag-kalibrierlabor","product_tag-kolbenmanometer","product_tag-kolbenpositionsanzeige","product_tag-referenznormal-druck","product_tag-wolframkarbid-kolben","product_tag-wolframkarbid-zylinder","pa_druckbereich-40-bis-5000-bar","pa_genauigkeit-0-05-vom-messwert-bis-0-008-auf-anfrage","pa_koben-zylindereinheit-einzelkolben","pa_medium-oel","pa_motorisierung-manuelle-drehung-der-gewichte","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","product-type-simple"],"_links":{"self":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product\/7253","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media\/3095"}],"wp:attachment":[{"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/media?parent=7253"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_brand?post=7253"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_cat?post=7253"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/europascal.de\/en\/wp-json\/wp\/v2\/product_tag?post=7253"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}