europascal

Transmille 3200B

The Transmille 3200B is an efficient electrical test equipment calibrator for professional calibration of loop, RCD, PAT, insulation and multifunction installation testers. A dedicated mains socket improves operator safety, while integrated continuity, insulation, voltage, loop and PAT calibration functions can reduce typical multifunction tester calibration time to under 15 minutes. With a 4:1 Test Uncertainty Ratio for suitable electricians’ test tools and expandable high-voltage options, the 3200B is ideal for professional electrical calibration laboratories.

Transmille 3200B is an efficient electrical test equipment calibrator designed for fast, safe and accurate calibration of insulation testers, loop testers, RCD testers, multifunction installation testers and PAT testers. By combining the functions normally provided by several individual standards into one benchtop calibration system, the 3200B significantly simplifies the calibration of electricians’ test equipment.

Transmille developed the 3200B specifically for electrical safety and installation test equipment. Traditional calibration methods can require multiple resistance standards, current measurement equipment, voltage sources and direct connections to mains voltage. The 3200B integrates these functions into a dedicated calibration platform designed to reduce setup time and improve operator safety.

According to Transmille, calibration of a typical multifunction electrical tester can be reduced from approximately 45 minutes to under 15 minutes when using the 3200B. The instrument is also designed to achieve a 4:1 Test Uncertainty Ratio (TUR) when calibrating suitable electricians’ test tools.

A dedicated localized mains socket on the front panel allows loop and RCD testers to be connected using their normal mains plug. This eliminates the need to make mains connections using individual 4 mm test leads and crocodile clips, reducing operator exposure to potentially hazardous connections.

The Transmille 3200B supports continuity resistance, continuity current, insulation resistance, AC voltage, loop resistance and numerous PAT tester functions. Optional accessories extend the system to high-voltage insulation testers and HiPot or breakdown testers.

At europascal, we provide professional calibration equipment for electrical measurement and electrical safety testing. The Transmille 3200B provides an efficient solution for calibration laboratories that regularly calibrate electricians’ multifunction testers, insulation testers, RCD testers and PAT testers.

For professional calibration and metrological traceability of electrical test equipment and calibrators, use the europascal Calibration Service.

Your Benefits at a Glance

The Transmille 3200B provides a dedicated calibration platform for electrical safety and installation testers.

Key benefits include:

  • Calibration of loop testers
  • Calibration of RCD testers
  • Calibration of insulation testers
  • Calibration of PAT testers
  • Calibration of multifunction installation testers
  • Calibration time reduced to under 15 minutes
  • Dedicated localized mains socket
  • Improved operator safety
  • 4:1 Test Uncertainty Ratio for suitable electricians’ test tools
  • Continuity resistance from 0.2 Ω to 1 kΩ
  • Continuity current measurement up to 320 mA
  • Insulation resistance up to 2 GΩ as standard
  • AC voltage output from 100 V to 400 V
  • Loop resistance calibration
  • PAT earth bond resistance calibration
  • PAT earth bond current measurement up to 30 A
  • PAT insulation resistance calibration
  • PAT leakage current calibration
  • PAT leakage test voltage measurement
  • Optional high-voltage insulation calibration
  • Optional HiPot and breakdown tester calibration
  • Short warm-up time
  • USB interface
  • Optional 3U rack mounting
  • Benchtop laboratory design

Electrical Test Equipment Calibration

The Transmille 3200B has been specifically designed for calibration of electrical test equipment used by electricians, electrical contractors, maintenance engineers and safety testing organizations.

Typical devices under test include:

  • Multifunction installation testers
  • Insulation resistance testers
  • Continuity testers
  • Loop impedance testers
  • RCD testers
  • PAT testers
  • Electrical safety testers

Instead of using several separate standards and measurement instruments, the 3200B combines the required calibration functions in one dedicated system.

This simplifies the calibration setup and can significantly improve laboratory productivity.

Calibration in Under 15 Minutes

Efficiency is one of the major advantages of the Transmille 3200B.

According to Transmille, traditional calibration methods can require up to approximately 45 minutes to test a typical multifunction electrical tester.

Using the 3200B, calibration time can be reduced to:

under 15 minutes

The reduction in calibration time can significantly increase laboratory throughput, particularly for calibration laboratories processing large numbers of electricians’ test instruments.

Faster calibration also reduces the amount of time technicians spend changing connections and configuring different standards.

Improved Calibration Safety

Electrical installation testers operate with potentially hazardous voltages and currents.

Traditional calibration setups can require technicians to make connections directly to mains voltage using individual test leads and crocodile clips.

The Transmille 3200B provides a dedicated localized mains socket directly on the front panel.

Loop and RCD testers can therefore be connected using their standard mains or line plug.

This reduces the need for exposed mains connections and improves operator safety during calibration.

4:1 Test Uncertainty Ratio

Electrical test equipment is continuously improving in accuracy and functionality.

The Transmille 3200B is designed to provide sufficient accuracy for calibration of modern electricians’ test tools.

Transmille states that the 3200B can achieve a:

4:1 Test Uncertainty Ratio

when calibrating suitable electricians’ test equipment.

This provides a practical accuracy relationship between the calibration standard and the device under test for the intended workload.

Continuity Resistance Calibration

The Transmille 3200B provides continuity resistance standards covering:

0.2 Ω to 1 kΩ

Standard best one-year accuracy is specified at approximately:

1 %

An optional enhanced specification provides accuracy down to:

0.25 %

for applicable continuity resistance functions.

This enables calibration of continuity measurement functions commonly found in installation and multifunction electrical testers.

Continuity Current Measurement

Many electrical installation testers use a defined test current when performing continuity measurements.

The Transmille 3200B can measure continuity test currents from:

0 to 320 mA

with best one-year accuracy of approximately:

1.3 %

This allows both the resistance measurement function and the generated continuity test current of suitable electrical testers to be evaluated.

Insulation Resistance Calibration

Insulation resistance measurement is a core function of many electrical safety testers.

The Transmille 3200B provides insulation resistance calibration up to:

2 GΩ

as standard.

Transmille specifies best one-year accuracy of approximately:

0.3 %

with an enhanced:

0.1 % option

available for applicable configurations.

This provides the resistance standards required to verify common insulation resistance testers and multifunction installation testers.

Insulation Test Voltage Measurement

In addition to resistance calibration, the 3200B can measure the test voltage generated by an insulation tester.

This is important because a complete calibration should evaluate not only the displayed insulation resistance but also the test voltage used to perform the measurement.

The integrated functionality reduces the need for separate high-voltage measurement equipment for common insulation tester workloads.

AC Voltage Output

The Transmille 3200B provides an AC voltage output covering:

100 V to 400 V

with best one-year accuracy of approximately:

0.2 %

This allows voltage measurement functions of compatible electrical installation and safety testers to be calibrated.

The integrated AC voltage source contributes to the broad workload coverage of the system.

Loop Tester Calibration

Loop impedance measurement is an important function of electrical installation testers.

The Transmille 3200B provides dedicated functionality for calibration of loop testers.

The dedicated front-panel mains connection allows a compatible loop tester to be connected in a similar manner to normal field operation.

This simplifies the calibration setup and reduces the need for exposed mains wiring.

The integrated loop calibration functionality makes the 3200B particularly suitable for laboratories calibrating multifunction installation testers.

RCD Tester Calibration

The Transmille 3200B also provides dedicated functions for calibration of RCD testers.

RCD testing is commonly incorporated into multifunction electrical installation testers.

By providing the necessary mains connection and dedicated calibration functions within one system, the 3200B simplifies verification of RCD-related functions.

This is particularly useful for calibration laboratories handling large quantities of electrical installation test equipment.

PAT Tester Calibration

Portable Appliance Testers combine several electrical safety measurements within one instrument.

The Transmille 3200B provides dedicated PAT calibration functionality covering important PAT measurement parameters.

These include:

  • Earth bond resistance
  • Earth bond current
  • Insulation resistance
  • Leakage current
  • Leakage test voltage
  • Load testing
  • Optional flash testing

This allows a broad range of PAT tester functions to be evaluated using one calibration system.

PAT Earth Bond Resistance

The 3200B provides PAT earth bond resistance standards covering approximately:

0.05 Ω to 1 kΩ

with best one-year accuracy of:

0.5 %

This function is used to calibrate the protective earth or earth bond resistance measurement of suitable PAT testers.

PAT Earth Bond Current Measurement

The Transmille 3200B can measure PAT earth bond test current over a range of:

100 mA to 30 A

with best one-year accuracy of approximately:

1.5 %

The high current capability is important because PAT testers can use significant test currents when checking protective earth connections.

Integrating this function into the calibrator avoids the need for a separate high-current measurement system for many PAT calibration workloads.

PAT Insulation Resistance

The PAT insulation resistance function extends to:

2 GΩ

with standard best one-year accuracy of approximately:

0.3 %

An optional enhanced accuracy of:

0.1 %

is available for applicable configurations.

This allows the insulation resistance function of suitable PAT testers to be calibrated directly.

PAT Leakage Current

The Transmille 3200B provides defined PAT leakage current points including:

2 mA

4.7 mA

and:

7.7 mA

with a resolution of:

1 µA

and best one-year accuracy specified at approximately:

1.5 % ± 2 counts

This enables calibration of the leakage current measurement function of suitable PAT testers.

PAT Leakage Test Voltage

The Transmille 3200B can measure PAT leakage test voltages from:

100 V to 300 V RMS

with resolution of:

0.01 V

and best one-year accuracy of approximately:

1.5 % ± 9 counts

This allows another important PAT tester parameter to be verified within the same calibration setup.

Optional Flash Testing

The workload of the Transmille 3200B can be extended using the optional FLASH Adapter.

This accessory enables calibration of Class 1 and Class 2 flash functions on compatible PAT testers.

The adapter supports flash voltages up to:

3 kV

This provides additional calibration capability for laboratories that handle PAT testers with high-voltage flash test functions.

High-Voltage Insulation Tester Calibration

For laboratories requiring higher insulation test voltages and resistance values, Transmille offers the optional:

EXT HV Adapter

This accessory allows insulation testers with test voltages up to:

15 kV

to be used with the 3200 platform.

Depending on the 3200B configuration, resistance simulation can be extended significantly beyond the standard range.

Transmille specifies resistance values up to:

1 TΩ

when the appropriate high-resistance option and EXT HV Adapter are used.

This greatly expands the workload beyond standard low-voltage insulation testers.

HiPot and Breakdown Tester Calibration

The Transmille 3200B can also be expanded using the optional:

Breakdown Adapter

This accessory allows calibration of voltage output and current measurement functions of suitable HiPot and breakdown testers.

The adapter provides AC and DC voltage ranges up to:

12 kV

and incorporates load resistors for current calibration.

This enables the 3200B platform to cover additional electrical safety test equipment beyond conventional installation and PAT testers.

Short Warm-Up Time

The Transmille 3200B is designed for fast preparation and efficient laboratory operation.

Transmille specifies a maximum warm-up time of:

20 minutes

depending on the time since the instrument was last used.

A short warm-up period is particularly useful for laboratories where equipment needs to be started and used efficiently at the beginning of a calibration session.

Benchtop Design

The Transmille 3200B is the benchtop version of the electrical test equipment calibrator platform.

Its dimensions are approximately:

43 cm × 46 cm × 14 cm

with a weight of approximately:

12 kg

This allows the instrument to be installed on a conventional calibration laboratory bench.

An optional:

3U rack-mount kit

is also available for integration into fixed laboratory systems.

USB Interface

The Transmille 3200B provides a standard USB interface for communication.

The interface allows the instrument to be incorporated into computer-supported calibration environments.

This is useful for laboratories aiming to standardize and automate repetitive calibration procedures.

Calibration Laboratory Applications

The Transmille 3200B is particularly suitable for calibration laboratories specializing in electrical safety and installation test equipment.

Instead of assembling separate resistance standards, voltage sources, current measuring systems and mains connection setups, the 3200B provides a purpose-designed calibration platform.

This can reduce:

  • Setup time
  • Calibration time
  • Connection changes
  • Operator exposure to hazardous connections
  • Number of individual standards required
  • Complexity of calibration procedures

The result is a more efficient workflow for repetitive electrical tester calibration.

3200B and 9200B

Transmille offers two versions of its electrical test equipment calibration platform.

The Transmille 3200B is designed primarily as a:

benchtop calibrator

while the 9200B provides a more transport-oriented solution.

Both systems are designed around the same core electrical test equipment calibration workload.

For a fixed calibration laboratory, the 3200B provides a practical benchtop solution.

Technical Highlights

Feature Transmille 3200B
Device type Electrical Test Equipment Calibrator
Design Benchtop
Continuity resistance 0.2 Ω to 1 kΩ
Continuity resistance accuracy 1 %, optional 0.25 %
Continuity current 0 to 320 mA
Continuity current accuracy 1.3 %
Insulation resistance Up to 2 GΩ standard
Insulation resistance accuracy 0.3 %, optional 0.1 %
AC voltage output 100 V to 400 V
AC voltage accuracy 0.2 %
PAT earth bond resistance 0.05 Ω to 1 kΩ
PAT earth bond resistance accuracy 0.5 %
PAT earth bond current 100 mA to 30 A
PAT earth bond current accuracy 1.5 %
PAT insulation resistance Up to 2 GΩ
PAT leakage current 2 mA to 7.7 mA
PAT leakage test voltage 100 V to 300 V
Optional flash testing Up to 3 kV
Optional EXT HV Insulation testers up to 15 kV
Extended resistance option Up to 1 TΩ with appropriate configuration
Breakdown adapter Up to 12 kV AC/DC
Warm-up Maximum 20 minutes
Interface USB
Dimensions Approx. 43 × 46 × 14 cm
Weight Approx. 12 kg
Rack mounting Optional 3U kit

Why Choose the Transmille 3200B?

The Transmille 3200B is designed specifically for one of the more complex electrical calibration workloads: calibration of electricians’ installation and safety test equipment.

Instead of requiring multiple individual standards and complicated mains connections, the 3200B combines the necessary functions in one purpose-built benchtop calibrator.

Calibration of a typical multifunction tester can be reduced from approximately 45 minutes to under 15 minutes, significantly improving laboratory throughput.

The dedicated localized mains socket improves operator safety by allowing compatible loop and RCD testers to be connected using their normal mains plug rather than exposed 4 mm leads and crocodile clips.

Continuity resistance, insulation resistance, AC voltage, loop and RCD functions are combined with comprehensive PAT tester calibration capabilities.

The system can also be expanded with accessories for flash testing, high-voltage insulation testers and HiPot or breakdown testers.

With a 4:1 Test Uncertainty Ratio for suitable electricians’ test tools, short warm-up time and dedicated electrical safety calibration functions, the 3200B provides a practical solution for commercial and industrial calibration laboratories.

At europascal, we provide professional solutions for electrical calibration and electrical safety testing. We can assist with selecting the appropriate Transmille 3200B configuration and accessories for your calibration workload.

For professional calibration and metrological traceability of electrical testers, multifunction installation testers and other electrical measuring equipment, use the europascal Calibration Service.

Discover more calibration equipment from europascal here.

Manufacturer information about the Transmille 3200B is available on the official Transmille 3200B Series product page.

Download Datasheet

Other Products

Scroll to Top

Request a Quote Now!

Download Product Datasheet

Enter your email address below to access the official product datasheet, including technical specifications, measurement ranges, product features, and performance details.