The Fluke Calibration 9100S is a compact handheld dry block calibrator designed for accurate temperature sensor calibration in industrial environments, calibration laboratories and field service applications.
With a temperature range from +35 °C to +375 °C, excellent temperature control and a weight of only 1 kg, the Fluke Calibration 9100S combines reliable calibration performance with exceptional portability.
The instrument is particularly suitable for calibrating resistance temperature detectors (RTDs), thermocouples and small bimetal thermometers directly at the installation site.
Unlike conventional temperature calibration baths, the Fluke Calibration 9100S uses a dry metal block to generate controlled temperatures. This eliminates the need for calibration liquids and simplifies transportation, preparation and maintenance.
Its compact construction makes the Fluke Calibration 9100S ideal for technicians who need a portable temperature source for routine calibration, commissioning and preventive maintenance.
The instrument features simple front-panel controls, a digital temperature display and an RS-232 interface for communication with compatible external equipment.
With a heating time of approximately 9.5 minutes from 35 °C to 375 °C, the Fluke Calibration 9100S significantly reduces waiting times between calibration points.
For professional temperature calibration equipment and metrological traceability, visit the europascal Calibration Service.
Your Benefits at a Glance
- Temperature range from +35 °C to +375 °C
- Extremely compact handheld construction
- Lightweight design weighing only 1 kg
- Temperature accuracy of ±0.25 °C at 50 °C and 100 °C
- Temperature accuracy of ±0.5 °C at 375 °C
- Temperature stability of ±0.07 °C at 50 °C
- Temperature stability of ±0.1 °C at 100 °C
- Temperature stability of ±0.3 °C at 375 °C
- Digital temperature display with 0.1 °C resolution
- Fast heating from 35 °C to 375 °C in approximately 9.5 minutes
- Cooling from 375 °C to 100 °C in approximately 14 minutes
- Typical stabilization time of 5 minutes
- Multiple calibration wells
- Different well configurations available
- Suitable for RTDs and Pt100 sensors
- Suitable for thermocouples
- Suitable for small bimetal thermometers
- Integrated RS-232 interface
- Simple front-panel operation
- No calibration liquid required
- Traceable manufacturer calibration data
- Professional calibration support from europascal
Temperature Range from +35 °C to +375 °C
The Fluke Calibration 9100S provides a temperature calibration range of:
+35 °C to +375 °C
This temperature range covers numerous industrial and laboratory calibration applications.
The instrument is particularly suitable for temperature sensors used in manufacturing, process instrumentation, heating systems and industrial maintenance.
Typical calibration temperatures include:
- 50 °C
- 100 °C
- 150 °C
- 200 °C
- 250 °C
- 300 °C
- 375 °C
The temperature can be adjusted directly using the front-panel controls.
The integrated temperature controller regulates the heating block to the selected setpoint.
For demanding calibration applications, sufficient stabilization time must be allowed before recording measurement results.
High Temperature Accuracy
The Fluke Calibration 9100S provides reliable temperature accuracy across its operating range.
The manufacturer specifies the following accuracy values:
| Temperature | Accuracy |
|---|---|
| 50 °C | ±0.25 °C |
| 100 °C | ±0.25 °C |
| 375 °C | ±0.5 °C |
These values describe the manufacturer’s specified temperature accuracy under defined operating conditions.
They should not be confused with the temperature stability specification or the calibration uncertainty stated on an individual calibration certificate.
For demanding comparison calibrations, an external reference thermometer can be used to measure the actual temperature of the calibration block.
The uncertainty of the complete measurement system must be considered when evaluating calibration results.
Excellent Temperature Stability
The Fluke Calibration 9100S provides stable temperature conditions for sensor calibration.
The manufacturer specifies:
| Temperature | Temperature Stability |
|---|---|
| 50 °C | ±0.07 °C |
| 100 °C | ±0.1 °C |
| 375 °C | ±0.3 °C |
Temperature stability describes the variation of the calibration block temperature over time under specified conditions.
Stable temperature conditions are essential for obtaining reliable calibration results.
When several temperature sensors are calibrated simultaneously, sufficient stabilization is particularly important.
The actual measurement uncertainty depends on the temperature stability, temperature uniformity, reference thermometer and device under test.
Fast Heating Performance
One of the main advantages of the Fluke Calibration 9100S is its fast heating performance.
The manufacturer specifies a typical heating time of:
9.5 minutes from 35 °C to 375 °C
This allows technicians to reach high calibration temperatures quickly.
Short heating times are particularly useful when performing multi-point calibration procedures.
The fast temperature response helps reduce waiting times and improves calibration efficiency.
Actual heating times may depend on ambient conditions, sensor loading and operating conditions.
Efficient Cooling Performance
The Fluke Calibration 9100S also provides efficient cooling performance.
The manufacturer specifies a typical cooling time of:
14 minutes from 375 °C to 100 °C
This allows technicians to perform calibration procedures involving both increasing and decreasing temperature sequences.
Cooling times depend on the initial temperature, ambient conditions and thermal loading.
The instrument should always be allowed to cool sufficiently before transportation or storage.
Short Stabilization Time
The Fluke Calibration 9100S features a typical stabilization time of:
5 minutes
This describes the time required for the calibration block to stabilize under the manufacturer’s specified conditions.
The stabilization time of the device under test must also be considered.
Large sensors or sensors with slow thermal response may require additional time before reliable measurements can be recorded.
For demanding calibration procedures, temperature stabilization should be verified using a suitable reference thermometer.
Compact Handheld Construction
The Fluke Calibration 9100S is one of the most compact dry block calibrators available for industrial temperature calibration.
Its dimensions are:
57 × 125 × 150 mm
The instrument weighs approximately:
1 kg
This makes it particularly suitable for mobile calibration applications.
The compact design allows technicians to transport the instrument easily between different measurement locations.
It also requires very little space on a workbench.
The Fluke Calibration 9100S is therefore an excellent solution for service technicians who need to calibrate temperature sensors directly at the installation site.
Multiple Calibration Wells
The Fluke Calibration 9100S features an integrated metal calibration block with several sensor wells.
Different configurations are available to accommodate temperature sensors with different diameters.
The standard well depth is:
102 mm
The smallest 1.6 mm well has a depth of:
89 mm
The appropriate well configuration should be selected according to the diameter of the temperature sensors being calibrated.
Good thermal contact between the sensor and the calibration well is essential for minimizing measurement errors.
The sensor should be inserted sufficiently deeply to reduce heat conduction effects along the probe stem.
Different Model Configurations
The Fluke Calibration 9100S is available in several configurations.
Fluke Calibration 9100S-A
The 9100S-A is a handheld dry block calibrator with well configuration A.
Fluke Calibration 9100S-B
The 9100S-B provides an alternative calibration well configuration.
Fluke Calibration 9100S-C
The 9100S-C is designed for applications requiring another combination of sensor well diameters.
Fluke Calibration 9100S-D
The 9100S-D provides an additional calibration well configuration.
The appropriate version should be selected according to the dimensions of the temperature sensors being calibrated.
Unlike dry block calibrators with removable inserts, the Fluke Calibration 9100S uses fixed calibration wells.
The well configuration is therefore an important consideration when ordering.
Calibration of RTDs and Pt100 Sensors
The Fluke Calibration 9100S is suitable for calibrating resistance temperature detectors.
Typical applications include:
- Pt100 calibration
- Pt1000 calibration
- Industrial RTD calibration
- Temperature probe verification
- Temperature indicator testing
The RTD sensor is inserted into a suitable calibration well.
The dry block generates a controlled temperature that can be compared with the temperature indicated by the device under test.
For more demanding applications, an external reference thermometer can be used.
The Fluke Calibration 9100S provides the temperature source but does not directly measure the electrical resistance of the RTD.
A suitable thermometer readout or resistance measurement instrument is required.
Calibration of Thermocouples
The Fluke Calibration 9100S can also be used for thermocouple calibration.
Thermocouples are widely used in industrial applications requiring elevated temperatures.
The instrument provides a stable temperature environment for checking thermocouple measurement systems.
The thermocouple is inserted into the calibration block and allowed to stabilize.
Its indicated temperature can then be compared with the reference temperature.
For accurate thermocouple calibration, reference junction compensation and the measurement uncertainty of the readout must be considered.
Calibration of Bimetal Thermometers
The Fluke Calibration 9100S is suitable for checking small bimetal thermometers.
Bimetal thermometers are commonly used in industrial heating systems, machinery and process equipment.
The sensing element is inserted into a suitable calibration well.
The indicated temperature can then be compared with the temperature generated by the calibration block.
The compact design of the Fluke Calibration 9100S makes it particularly useful for routine verification of mechanical temperature indicators.
RS-232 Interface
The Fluke Calibration 9100S includes an RS-232 communication interface.
This interface allows the instrument to communicate with compatible external equipment.
RS-232 communication can be used for remote operation and integration into suitable calibration systems.
This is particularly useful for laboratories and industrial users who want to incorporate the dry block calibrator into automated or computer-assisted calibration procedures.
The available communication commands and interface settings are described in the manufacturer’s operating instructions.
Simple Front-Panel Operation
The Fluke Calibration 9100S is designed for straightforward operation.
The temperature setpoint can be entered using the front-panel buttons.
The digital display provides information about the temperature.
The instrument features a display resolution of:
0.1 °C
This makes it easy to set and monitor calibration temperatures.
The simple operating concept reduces training requirements and allows technicians to begin calibration work quickly.
No Calibration Liquid Required
Unlike liquid calibration baths, the Fluke Calibration 9100S does not require a calibration fluid.
The instrument uses a solid metal block to transfer heat to the temperature sensors.
This provides several practical advantages.
There is no need to fill or drain calibration liquid.
The risk of fluid leakage during transportation is eliminated.
Cleaning and maintenance requirements are reduced.
The instrument can be prepared for use quickly.
These advantages make the Fluke Calibration 9100S particularly suitable for field calibration and mobile maintenance applications.
Traceable Manufacturer Calibration
The Fluke Calibration 9100S is supplied with manufacturer calibration data traceable to national standards.
The manufacturer specifies calibration data at the following temperatures:
| Calibration Point |
|---|
| 50 °C |
| 100 °C |
| 150 °C |
| 200 °C |
| 250 °C |
| 300 °C |
| 375 °C |
These calibration points cover the main operating range of the instrument.
Regular recalibration is recommended to verify the long-term performance of the dry block calibrator.
For applications requiring accredited calibration, the availability and scope of the appropriate calibration service should be confirmed separately.
Technical Highlights
| Specification | Fluke Calibration 9100S |
|---|---|
| Manufacturer | Fluke Calibration |
| Model | 9100S |
| Product type | Handheld Dry Block Calibrator |
| Temperature range | +35 °C to +375 °C |
| Accuracy at 50 °C | ±0.25 °C |
| Accuracy at 100 °C | ±0.25 °C |
| Accuracy at 375 °C | ±0.5 °C |
| Stability at 50 °C | ±0.07 °C |
| Stability at 100 °C | ±0.1 °C |
| Stability at 375 °C | ±0.3 °C |
| Display resolution | 0.1 °C |
| Heating time, 35 °C to 375 °C | 9.5 minutes |
| Cooling time, 375 °C to 100 °C | 14 minutes |
| Typical stabilization time | 5 minutes |
| Well-to-well uniformity | ±0.2 °C under specified conditions |
| Standard well depth | 102 mm |
| Smallest well depth | 89 mm |
| Removable inserts | No |
| Model configurations | 9100S-A, B, C and D |
| Communication interface | RS-232 |
| Power supply | 115 V or 230 V AC version |
| Power consumption | 175 W |
| Dimensions (H × W × D) | 57 × 125 × 150 mm |
| Weight | Approx. 1 kg |
| Calibration | NIST-traceable manufacturer calibration data |
| Typical applications | RTD, thermocouple and bimetal thermometer calibration |
Fluke Calibration 9100S or 9102S?
The Fluke Calibration 9100S and 9102S are both compact handheld dry block calibrators.
However, they are designed for different temperature ranges.
| Specification | Fluke Calibration 9100S | Fluke Calibration 9102S |
|---|---|---|
| Temperature range | +35 °C to +375 °C | −10 °C to +122 °C |
| Accuracy | ±0.25 °C to ±0.5 °C | ±0.25 °C |
| Temperature stability | ±0.07 °C to ±0.3 °C | ±0.05 °C |
| Display resolution | 0.1 °C | 0.1 °C |
| Well depth | 102 mm | 102 mm |
| Weight | 1 kg | 1.8 kg |
| RS-232 interface | Yes | Yes |
| Removable inserts | No | Yes |
The Fluke Calibration 9100S is particularly suitable for applications requiring temperatures up to 375 °C.
The Fluke Calibration 9102S is designed for applications requiring temperatures below ambient temperature.
The correct model should be selected according to the required temperature range, sensor dimensions and calibration uncertainty.
Calibration Service by europascal
Regular calibration is essential for maintaining reliable and traceable temperature measurements.
europascal provides professional calibration services for temperature measuring instruments and calibration equipment.
When the Fluke Calibration 9100S is used for temperature sensor calibration, the measurement uncertainty must be evaluated according to the complete measurement procedure.
Relevant uncertainty contributions may include:
- Calibration block temperature accuracy
- Temperature stability
- Temperature uniformity
- Reference thermometer calibration uncertainty
- Thermometer readout uncertainty
- Sensor immersion effects
- Thermal contact between the sensor and calibration well
- Measurement repeatability
- Temperature drift during measurement
The individual uncertainty contributions must be evaluated carefully to avoid double-counting effects already included in the manufacturer’s specifications.
For professional calibration services and metrological traceability, visit the europascal Calibration Service.
Why Choose the Fluke Calibration 9100S?
The Fluke Calibration 9100S combines reliable temperature calibration performance with an exceptionally compact and lightweight design.
Its temperature range from +35 °C to +375 °C covers numerous industrial and laboratory applications.
Temperature accuracy down to ±0.25 °C and stable temperature control provide reliable conditions for routine sensor calibration.
The instrument weighs only 1 kg, making it particularly suitable for mobile calibration applications.
Fast heating and cooling times help reduce waiting periods between calibration points.
Multiple calibration wells allow different temperature sensors to be calibrated without requiring a liquid bath.
The integrated RS-232 interface provides additional flexibility for computer-assisted calibration procedures.
For calibration technicians, maintenance engineers and industrial users requiring a compact and portable dry block calibrator, the Fluke Calibration 9100S provides an excellent combination of accuracy, efficiency and convenience.
europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.
Typical Applications for the Fluke Calibration 9100S
Typical applications include:
- Temperature sensor calibration
- Pt100 calibration
- Pt1000 calibration
- RTD calibration
- Thermocouple calibration
- Bimetal thermometer verification
- Temperature indicator testing
- Temperature transmitter calibration with external measurement equipment
- Industrial process instrumentation
- Preventive maintenance
- Commissioning
- Field calibration
- Mobile temperature calibration
- Calibration laboratories
- Industrial quality assurance
- Temperature metrology
- Heating system maintenance
The combination of a wide temperature range, fast heating performance, compact construction and convenient operation makes the Fluke Calibration 9100S a professional solution for portable temperature calibration.
Find more Fluke Calibration products here.
Manufacturer information for the Fluke Calibration 9100S can be found on the official Fluke Calibration website.