Fluke 8808A is a precise 5.5-digit bench digital multimeter designed for professional calibration laboratories, manufacturing, research and development, service departments and automated test systems. It combines high measurement accuracy with straightforward operation, a dual display, dedicated leakage current measurement and the innovative 2×4-wire resistance measurement technique.
With a basic DC voltage accuracy of 0.015 %, DC voltage measurement up to 1000 V, AC voltage up to 750 V, current measurement up to 10 A, resistance measurement up to 100 MΩ and frequency measurement up to 1 MHz, the Fluke 8808A covers the essential electrical quantities required for a broad range of laboratory and production applications.
The 5.5-digit resolution provides detailed measurement results while maintaining fast and intuitive operation. Six dedicated setup keys allow frequently used instrument configurations to be stored and recalled at the touch of a button. This is particularly useful for repetitive calibration, inspection and production testing.
A dedicated DC leakage current measurement function provides improved performance for sensitive low-current measurements. For resistance measurements, Fluke’s 2×4-wire technique allows precision four-wire measurements using only two specially designed test leads.
The integrated Hi/Lo Limit Compare function provides clear Pass/Fail indication, making the 8808A particularly suitable for repetitive production testing and incoming inspection.
At europascal, we provide professional electrical calibration solutions ranging from precision digital multimeters and reference instruments to multiproduct calibrators and complete automated calibration systems.
For professional calibration and metrological traceability of digital multimeters and other electrical measuring equipment, use the europascal Calibration Service.
Your Benefits at a Glance
- Professional 5.5-digit bench digital multimeter
- Basic DC voltage accuracy of 0.015 %
- DC voltage measurement up to 1000 V
- AC voltage measurement up to 750 V
- DC current measurement up to 10 A
- AC current measurement up to 10 A
- Resistance measurement up to 100 MΩ
- Frequency measurement up to 1 MHz
- Maximum DC voltage resolution of 1 µV
- Maximum DC current resolution of 1 nA
- Maximum resistance resolution of 1 mΩ
- Dual measurement display
- Dedicated DC leakage current measurement
- 2×4-wire resistance measurement
- Four-wire resistance measurement
- Six programmable setup buttons
- Hi/Lo Limit Compare function
- Clear Pass/Fail indication
- dB and dBm mathematical functions
- Min/Max functions
- Continuity measurement
- Diode test
- RS-232 interface
- USB connectivity using an adapter
- Fluke 45 remote command emulation
- Suitable for automated test systems
- Compact benchtop design
5.5-Digit Resolution
The Fluke 8808A provides:
5.5-digit resolution
for precision bench measurements.
This resolution makes the instrument suitable for applications where a conventional handheld multimeter does not provide sufficient resolution or measurement performance.
Typical applications include:
- Calibration laboratories
- Electrical laboratories
- Manufacturing
- Production testing
- Research and development
- Quality assurance
- Incoming inspection
- Service departments
- Automated test systems
The 8808A combines this resolution with an easy-to-use front-panel interface.
DC Voltage Measurement up to 1000 V
The Fluke 8808A provides DC voltage measurement ranges from:
200 mV to 1000 V
Maximum resolution is:
1 µV
Fluke specifies a basic DC voltage accuracy of:
±(0.015 % of reading + 0.003 % of range)
for the applicable specification.
This makes DC voltage measurement one of the core strengths of the 8808A.
The wide range allows the instrument to measure signals ranging from low-level electronic circuits to high-voltage electrical equipment.
AC Voltage Measurement up to 750 V
AC voltage measurement ranges extend from:
200 mV to 750 V
with maximum resolution down to:
1 µV
The AC voltage frequency range extends up to:
100 kHz
depending on the selected range and signal level.
Fluke specifies basic AC voltage accuracy of:
±(0.2 % of reading + 0.05 % of range)
for the applicable specification.
This provides useful AC measurement performance for laboratory, service and production applications.
DC Current Measurement up to 10 A
The Fluke 8808A measures DC current over ranges extending from:
200 µA to 10 A
Maximum resolution reaches:
1 nA
Fluke specifies basic DC current accuracy of:
±(0.02 % of reading + 0.005 % of range)
for the applicable range and conditions.
This broad current capability allows both low-current electronic circuits and higher-current loads to be measured using one benchtop instrument.
Dedicated Leakage Current Measurement
An important feature of the Fluke 8808A is its dedicated DC leakage current measurement capability.
The instrument includes low-impedance, low-current ranges specifically intended for sensitive leakage current measurements.
This helps reduce the burden voltage effects that can influence conventional current measurements in sensitive electronic circuits.
The function is particularly useful for applications such as:
- Battery-powered devices
- Standby circuits
- Electronic assemblies
- Power supplies
- Low-current circuitry
- Production testing
AC Current up to 10 A
The 8808A also measures AC current up to:
10 A
The specified AC current measurement frequency extends up to:
2 kHz
depending on the selected range.
This enables the instrument to cover many common AC current measurements in laboratory and industrial applications.
Resistance Measurement up to 100 MΩ
The Fluke 8808A provides resistance measurement ranges from:
200 Ω to 100 MΩ
Maximum resolution reaches:
1 mΩ
Fluke specifies basic resistance accuracy of:
±(0.02 % of reading + 0.003 % of range)
for the applicable conditions.
The broad resistance range enables measurement of low-value resistors as well as high-resistance components.
2×4-Wire Resistance Measurement
One of the most distinctive features of the Fluke 8808A is its patented 2×4-wire resistance measurement technique.
Conventional four-wire resistance measurements normally require four individual test leads.
The 8808A can perform a precision four-wire resistance measurement using only two specially designed 2×4-wire test leads.
Each test lead provides both source and sense connections.
This simplifies four-wire resistance measurements while retaining the main advantage of the Kelvin measurement principle.
Fluke also supports conventional four-lead resistance measurements.
Why Use Four-Wire Resistance Measurement?
When measuring low resistance values, the resistance of the test leads and contacts can become significant compared with the device under test.
A conventional two-wire measurement includes these additional resistances in the measured value.
Four-wire measurement separates the current-carrying leads from the voltage-sensing leads.
This significantly reduces the influence of:
- Test lead resistance
- Contact resistance
- Connection resistance
The method is therefore particularly valuable for precise low-resistance measurements.
Frequency Measurement up to 1 MHz
The Fluke 8808A provides frequency measurement from:
20 Hz to 1 MHz
Maximum frequency resolution is:
0.1 mHz
Fluke specifies frequency accuracy of:
0.01 %
for the applicable operating conditions.
This integrated frequency function eliminates the need for a separate frequency counter in many routine applications.
Dual Display
The Fluke 8808A features a multi-segment VFD with:
dual readings
Two measurement parameters can therefore be displayed simultaneously where supported.
This improves efficiency when evaluating related measurement information.
The bright vacuum fluorescent display provides clear readability in laboratory and production environments.
Six Setup Keys
Six dedicated front-panel setup keys are provided:
S1 to S6
Frequently used measurement configurations can be stored in these locations.
A stored setup can include parameters such as:
- Measurement function
- Measurement range
- Test limits
- Other relevant instrument settings
The operator can then recall the complete configuration with a single setup key.
This is particularly valuable for repetitive production or calibration procedures.
Reduce Operator Errors
The setup memory helps reduce the number of manual steps required for routine measurements.
Instead of following a long work instruction and manually configuring each parameter, the required measurement configuration can be stored beforehand.
Operators can then select the appropriate setup directly.
This improves:
- Repeatability
- Efficiency
- Ease of operation
- Process consistency
and reduces the risk of incorrect instrument configuration.
Hi/Lo Limit Compare
The Fluke 8808A includes a Limit Compare function.
Upper and lower limits can be defined for the measurement.
The instrument then evaluates whether the measured value is inside or outside the specified limits.
Clear:
Pass / Fail
indicators provide immediate feedback to the operator.
This is especially useful for:
- Production testing
- Incoming inspection
- Quality assurance
- Repetitive component testing
- Functional testing
Mathematical Functions
The 8808A includes useful mathematical functions such as:
- dB
- dBm
- Minimum
- Maximum
- Null
These functions provide additional analysis capability directly within the multimeter.
For many routine applications, calculations can therefore be performed without transferring the measured value to separate software.
Continuity and Diode Testing
In addition to its precision measurement functions, the Fluke 8808A includes:
Continuity testing
and:
Diode testing
These functions make the instrument suitable for general electronics troubleshooting and service applications as well as precision laboratory measurements.
Automated Measurement Systems
The 8808A is suitable for integration into automated test and measurement systems.
A standard:
RS-232
interface provides remote control capability.
USB connectivity is available using a suitable USB-to-RS-232 adapter.
The instrument supports:
Simplified ASCII
commands as well as:
Fluke 45 remote command emulation
This helps integrate the 8808A into existing automated systems.
Fluke 45 Command Emulation
Fluke 45 remote command emulation can be particularly useful when replacing an older Fluke 45 multimeter in an automated test system.
Existing software may require fewer changes because the 8808A can emulate the remote command structure of the earlier instrument.
This can simplify modernization of existing test stations.
Calibration Laboratory Applications
The Fluke 8808A is well suited for electrical calibration laboratories.
Typical applications include:
- Measurement during calibration procedures
- Verification of electrical calibrators
- Measurement of voltage sources
- Resistance measurements
- Current measurements
- Frequency measurements
- Device-under-test monitoring
- Automated calibration procedures
Its 5.5-digit resolution provides a useful balance between measurement performance, speed and cost.
Production Testing
Fluke specifically designed the 8808A for applications including manufacturing and production testing.
Six setup memories and Limit Compare functionality simplify repetitive tests.
An operator can select a stored test configuration, connect the device under test and immediately receive a Pass/Fail result.
This helps standardize test procedures across multiple operators.
Research and Development
The Fluke 8808A is also suitable for research and development laboratories.
Its broad electrical measurement capability allows engineers and technicians to measure:
- DC voltage
- AC voltage
- DC current
- AC current
- Resistance
- Frequency
- Diodes
- Continuity
The dual display and high resolution are particularly useful during circuit development and troubleshooting.
Service Applications
For service departments, the 8808A provides the familiar functions of a digital multimeter with the additional advantages of a precision benchtop instrument.
Its stable bench configuration, clear display and dedicated function keys make it suitable for repeated diagnostic and verification measurements.
Calibration with Fluke Multiproduct Calibrators
The 8808A can be calibrated using a suitable high-performance electrical multiproduct calibrator.
Fluke specifically lists the 8808A as an example of a 5.5-digit multimeter workload for its current 5560A and 5550A multiproduct calibrators, with a stated 4:1 TUR for the defined target workload.
This makes the combination suitable for automated electrical calibration laboratories.
Compact Benchtop Design
The Fluke 8808A combines its measurement functions in a compact enclosure.
Dimensions are approximately:
88 × 217 × 297 mm
and weight is approximately:
2.1 kg
The compact format makes it easy to integrate the instrument into:
- Laboratory benches
- Test racks
- Service workstations
- Automated systems
- Production test stations
Safety Ratings
The 8808A is designed for:
CAT I 1000 V
and:
CAT II 600 V
applications according to the specified safety standards.
The appropriate measurement category and maximum input limits must always be observed when connecting the instrument.
Technical Highlights
The Fluke 8808A combines high-resolution electrical measurement with efficient operation:
- 5.5-digit Digital Multimeter
- Dual display
- DC voltage to 1000 V
- AC voltage to 750 V
- DC current to 10 A
- AC current to 10 A
- Resistance to 100 MΩ
- Frequency to 1 MHz
- 1 µV maximum voltage resolution
- 1 nA maximum DC current resolution
- 1 mΩ maximum resistance resolution
- 0.1 mHz maximum frequency resolution
- Basic DC voltage accuracy 0.015 %
- Dedicated DC leakage current measurement
- 2×4-wire resistance measurement
- Conventional four-wire resistance measurement
- Six setup memories
- Hi/Lo Limit Compare
- Pass/Fail indication
- dB and dBm
- Min/Max
- Continuity
- Diode test
- RS-232
- USB via adapter
- Fluke 45 remote command emulation
Technical Specifications
| Feature | Fluke 8808A |
|---|---|
| Manufacturer | Fluke |
| Model | 8808A |
| Device type | Bench Digital Multimeter |
| Resolution | 5.5 digits |
| Display | Dual-reading VFD |
| DC voltage | 200 mV to 1000 V |
| DC voltage resolution | Down to 1 µV |
| Basic DC voltage accuracy | ±(0.015 % reading + 0.003 % range) |
| AC voltage | 200 mV to 750 V |
| AC voltage resolution | Down to 1 µV |
| AC voltage frequency | Up to 100 kHz |
| Resistance | 200 Ω to 100 MΩ |
| Resistance resolution | Down to 1 mΩ |
| Resistance technique | 2-wire, 4-wire and 2×4-wire |
| DC current | 200 µA to 10 A |
| DC current resolution | Down to 1 nA |
| AC current | 20 mA to 10 A |
| AC current frequency | Up to 2 kHz |
| Frequency | 20 Hz to 1 MHz |
| Frequency resolution | Down to 0.1 mHz |
| Frequency accuracy | 0.01 % |
| Leakage current | Dedicated DC leakage measurement |
| Limit testing | Hi/Lo with Pass/Fail |
| Setup memories | 6 |
| Mathematical functions | dB, dBm, Min, Max, Null |
| Interfaces | RS-232, USB via adapter |
| Remote compatibility | Simplified ASCII, Fluke 45 emulation |
| Safety | CAT I 1000 V, CAT II 600 V |
| Dimensions | 88 × 217 × 297 mm |
| Weight | Approx. 2.1 kg |
| Warranty | 3 years |
Why Choose the Fluke 8808A?
The Fluke 8808A combines 5.5-digit resolution with a broad range of electrical measurement functions and straightforward operation.
Its basic DC voltage accuracy of 0.015 % and measurement capability up to 1000 V DC, 750 V AC, 10 A, 100 MΩ and 1 MHz make it suitable for many laboratory, production and service applications.
The dedicated DC leakage current function extends its capability for sensitive low-current measurements.
For resistance measurements, the innovative 2×4-wire technique simplifies precision four-wire measurements by allowing specially designed two-lead connections while retaining the benefits of Kelvin measurement.
Six setup memories make repetitive measurements fast and consistent, while the Hi/Lo Limit Compare function provides clear Pass/Fail results for production testing and quality assurance.
The dual display provides clear measurement information, and mathematical functions such as dB, dBm, Min and Max extend the instrument’s analytical capability.
RS-232 communication, USB connectivity via an adapter and Fluke 45 command emulation simplify integration into automated test and calibration systems.
For calibration laboratories, manufacturing, research and development or professional service applications requiring more performance than a conventional handheld multimeter, the Fluke 8808A provides a practical and proven benchtop measurement solution.
At europascal, we can support the Fluke 8808A with professional calibration services and help integrate the instrument into your electrical calibration and measurement environment.
For professional calibration and metrological traceability of digital multimeters and other electrical measuring equipment, use the europascal Calibration Service.
Discover more Fluke Calibration products here.
Manufacturer information about the Fluke 8808A is available on the official Fluke 8808A product page.