Fluke Calibration 9102S Portable Dry Block Calibrator

The Fluke Calibration 9102S is a compact and portable dry block calibrator for professional temperature sensor calibration. With a temperature range of −10 °C to +122 °C, accuracy of ±0.25 °C and stability of ±0.05 °C, it provides reliable performance for laboratory and field applications. Featuring two calibration wells, interchangeable inserts, fast heating and cooling, and a lightweight 1.8 kg design, it is ideal for calibrating RTDs, thermocouples, digital thermometers and temperature switches.

The Fluke Calibration 9102S is a compact, portable dry block calibrator designed for accurate temperature sensor calibration in laboratories, industrial facilities and field service applications.

With a temperature range from −10 °C to +122 °C, temperature accuracy of ±0.25 °C and excellent temperature stability of ±0.05 °C, the Fluke Calibration 9102S provides reliable performance for demanding temperature calibration applications.

The instrument is particularly suitable for calibrating resistance temperature detectors (RTDs), thermocouples, digital thermometers, dial thermometers and temperature switches.

Unlike conventional dry block calibrators designed primarily for high temperatures, the Fluke Calibration 9102S can generate temperatures below ambient temperature.

This makes it especially useful for calibrating temperature sensors used in refrigeration, environmental monitoring, pharmaceutical manufacturing, food processing and industrial temperature measurement.

The Fluke Calibration 9102S features two calibration wells, removable inserts, an RS-232 interface and a compact design weighing only 1.8 kg.

Its ability to operate from an AC power supply or a suitable 12 V DC source provides additional flexibility for mobile calibration applications.

For professional temperature calibration equipment and metrological traceability, visit the europascal Calibration Service.

Your Benefits at a Glance

  • Temperature range from −10 °C to +122 °C
  • Temperature accuracy of ±0.25 °C
  • Excellent temperature stability of ±0.05 °C
  • Suitable for calibration below ambient temperature
  • Compact and portable construction
  • Lightweight design weighing only 1.8 kg
  • Two independent calibration wells
  • Removable calibration inserts
  • Calibration well depth of 102 mm
  • Inserts available from 1.6 mm to 11.1 mm
  • Two standard inserts included
  • Fast heating and cooling performance
  • Heating from ambient temperature to 100 °C in approximately 10 minutes
  • Cooling from ambient temperature to 0 °C in approximately 10 minutes
  • Typical stabilization time of 7 minutes
  • Integrated RS-232 communication interface
  • AC power supply or 12 V DC operation
  • Suitable for RTDs and Pt100 sensors
  • Suitable for thermocouples
  • Suitable for temperature switches
  • NIST-traceable manufacturer calibration included
  • Professional calibration support from europascal

Temperature Range from −10 °C to +122 °C

The Fluke Calibration 9102S provides a temperature calibration range of:

−10 °C to +122 °C

This range is specified at an ambient temperature of 23 °C.

The ability to generate temperatures below ambient temperature is one of the most important advantages of the instrument.

Many industrial temperature sensors operate in environments where temperatures are close to or below room temperature.

Examples include refrigeration systems, environmental chambers, temperature-controlled storage facilities and industrial cooling processes.

The Fluke Calibration 9102S allows these sensors to be checked without requiring a large laboratory temperature bath.

Typical calibration temperatures include:

  • −10 °C
  • 0 °C
  • 10 °C
  • 20 °C
  • 25 °C
  • 50 °C
  • 75 °C
  • 100 °C
  • 122 °C

The achievable minimum temperature depends on the ambient conditions.

For accurate calibration results, sufficient stabilization time must be allowed before recording measurements.

High Temperature Accuracy of ±0.25 °C

The Fluke Calibration 9102S provides excellent temperature accuracy for a compact portable dry block calibrator.

The manufacturer specifies:

±0.25 °C

This specification describes the temperature accuracy under the manufacturer’s defined operating conditions.

It must not be confused with temperature stability or the uncertainty stated on an individual calibration certificate.

For demanding comparison calibrations, a suitable external reference thermometer can be used.

The reference thermometer measures the actual temperature within the calibration well.

This allows the device under test to be compared directly with a traceable temperature reference.

The uncertainty of the complete calibration system must be evaluated according to the applicable calibration procedure.

Excellent Temperature Stability of ±0.05 °C

The Fluke Calibration 9102S provides excellent temperature stability.

The manufacturer specifies:

±0.05 °C

Temperature stability describes the variation of the calibration block temperature over time under defined conditions.

Stable temperature conditions are essential for reliable temperature sensor calibration.

The Fluke Calibration 9102S provides a controlled temperature environment suitable for routine calibration and verification procedures.

For demanding applications, the actual temperature stability should be considered when evaluating the measurement uncertainty.

Two Calibration Wells

The Fluke Calibration 9102S features two calibration wells.

Both wells have a nominal diameter of:

12.7 mm (1/2 inch)

The well depth is:

102 mm

The two-well design allows a reference thermometer and a device under test to be inserted simultaneously.

This makes the instrument particularly suitable for comparison calibration.

One well can accommodate the reference thermometer, while the second well accommodates the temperature sensor being calibrated.

The manufacturer specifies well-to-well uniformity of:

±0.2 °C

This specification applies when sensors of similar dimensions are inserted to equal depths.

For accurate calibration, the influence of sensor geometry, immersion depth and thermal contact must be considered.

Removable Calibration Inserts

The Fluke Calibration 9102S uses removable calibration inserts.

These allow the instrument to accommodate temperature sensors with different diameters.

Available insert diameters include:

Insert Diameter Imperial Size
1.6 mm 1/16 inch
3.2 mm 1/8 inch
4.0 mm 5/32 inch
4.8 mm 3/16 inch
6.4 mm 1/4 inch
7.9 mm 5/16 inch
9.5 mm 3/8 inch
11.1 mm 7/16 inch

Blank inserts are also available.

The standard configuration includes inserts with diameters of:

4.8 mm and 6.4 mm

The appropriate insert should be selected according to the diameter of the temperature sensor.

A small clearance between the sensor and the insert improves thermal contact and reduces measurement errors.

Excessive clearance can increase temperature differences between the calibration block and the sensing element.

Fast Heating Performance

The Fluke Calibration 9102S provides efficient heating performance.

The manufacturer specifies a typical heating time of:

10 minutes from ambient temperature to 100 °C

This allows technicians to reach common calibration temperatures quickly.

Short heating times are particularly useful when performing multi-point calibration procedures.

The fast temperature response helps reduce waiting periods and improves calibration efficiency.

Actual heating times depend on ambient conditions, sensor loading and operating conditions.

Fast Cooling Performance

The Fluke Calibration 9102S also provides efficient cooling performance.

The manufacturer specifies a typical cooling time of:

10 minutes from ambient temperature to 0 °C

This is particularly useful for temperature sensor calibration below ambient temperature.

The integrated temperature control system allows the instrument to generate both heating and cooling conditions.

This eliminates the need for separate heating and cooling devices for many routine calibration applications.

Short Stabilization Time

The Fluke Calibration 9102S features a typical stabilization time of:

7 minutes

This describes the time required for the calibration block to stabilize under the manufacturer’s specified conditions.

The stabilization time of the device under test must also be considered.

Large sensors or sensors with slow thermal response may require additional time before reliable measurements can be recorded.

For demanding calibration procedures, temperature stabilization should be verified using a suitable reference thermometer.

Compact Portable Construction

The Fluke Calibration 9102S is designed for mobile temperature calibration.

Its dimensions are:

99 × 140 × 175 mm

The instrument weighs approximately:

1.8 kg

This makes it suitable for transportation between different measurement locations.

The compact design also requires very little space on a laboratory workbench.

The Fluke Calibration 9102S is particularly useful for technicians who need to calibrate temperature sensors directly at the installation site.

AC and 12 V DC Operation

The Fluke Calibration 9102S offers flexible power supply options.

The instrument can operate using:

94–234 V AC, 50/60 Hz

or:

12 V DC

The rated power consumption is approximately:

60 W

The 12 V DC capability provides additional flexibility for mobile applications.

This can be useful when the instrument is operated from a suitable external DC power source.

The power source must meet the manufacturer’s electrical requirements.

Calibration of RTDs and Pt100 Sensors

The Fluke Calibration 9102S is suitable for calibrating resistance temperature detectors.

Typical applications include:

  • Pt100 calibration
  • Pt1000 calibration
  • Industrial RTD calibration
  • Temperature probe verification
  • Temperature indicator testing

The RTD sensor is inserted into a suitable calibration insert.

The dry block generates a controlled temperature that can be compared with the temperature indicated by the device under test.

For more demanding applications, an external reference thermometer can be used.

The Fluke Calibration 9102S provides the temperature source but does not directly measure the electrical resistance of the RTD.

A suitable thermometer readout or resistance measurement instrument is required.

Calibration of Thermocouples

The Fluke Calibration 9102S can also be used for thermocouple calibration.

Thermocouples are widely used in industrial temperature measurement.

The instrument provides a stable temperature environment for checking thermocouple measurement systems.

The thermocouple is inserted into the calibration block and allowed to stabilize.

Its indicated temperature can then be compared with the reference temperature.

For accurate thermocouple calibration, reference junction compensation and the measurement uncertainty of the readout must be considered.

Calibration of Digital Thermometers

The Fluke Calibration 9102S is suitable for checking digital thermometers.

Digital thermometers are commonly used in laboratories, industrial production and quality assurance.

The temperature sensor is inserted into a suitable calibration well.

The thermometer indication is then compared with the reference temperature.

This allows users to verify the measurement performance of the thermometer at several temperature points.

Calibration of Temperature Switches

The Fluke Calibration 9102S is also suitable for checking temperature switches.

Temperature switches are used to monitor and control industrial processes.

They activate or deactivate an electrical contact when a defined temperature is reached.

The Fluke Calibration 9102S provides a controlled temperature environment for checking switching points.

The temperature can be increased or decreased to determine the switching temperature.

An external instrument is required to detect the electrical switching signal.

The instrument can also be used to investigate switching hysteresis.

RS-232 Interface

The Fluke Calibration 9102S includes an RS-232 communication interface.

This interface allows the instrument to communicate with compatible external equipment.

RS-232 communication can be used for remote operation and integration into suitable calibration systems.

This is particularly useful for laboratories and industrial users who want to incorporate the dry block calibrator into automated or computer-assisted calibration procedures.

The available communication commands and interface settings are described in the manufacturer’s operating instructions.

No Calibration Liquid Required

Unlike liquid calibration baths, the Fluke Calibration 9102S does not require a calibration fluid.

The instrument uses a solid metal block to transfer heat to the temperature sensors.

This provides several practical advantages:

  • No calibration liquid required
  • No filling or draining procedures
  • No risk of calibration fluid leakage
  • Reduced cleaning requirements
  • Convenient transportation
  • Fast preparation for calibration work

These advantages make the Fluke Calibration 9102S particularly suitable for field calibration and mobile maintenance applications.

NIST-Traceable Manufacturer Calibration

The Fluke Calibration 9102S is supplied with NIST-traceable manufacturer calibration data.

The manufacturer specifies calibration data at seven temperature points:

Calibration Point
−10 °C
0 °C
25 °C
50 °C
75 °C
100 °C
122 °C

These calibration points cover the operating range of the instrument.

Regular recalibration is recommended to verify the long-term performance of the dry block calibrator.

For applications requiring accredited calibration, the availability and scope of the appropriate calibration service should be confirmed separately.

Technical Highlights

Specification Fluke Calibration 9102S
Manufacturer Fluke Calibration
Model 9102S
Product type Portable Dry Block Calibrator
Temperature range −10 °C to +122 °C
Reference ambient temperature 23 °C
Temperature accuracy ±0.25 °C
Temperature stability ±0.05 °C
Well-to-well uniformity ±0.2 °C
Number of calibration wells 2
Well diameter 12.7 mm
Well depth 102 mm
Removable inserts Yes
Available insert diameters 1.6–11.1 mm
Standard inserts 4.8 mm and 6.4 mm
Heating time, ambient to 100 °C 10 minutes
Cooling time, ambient to 0 °C 10 minutes
Typical stabilization time 7 minutes
Communication interface RS-232
AC power supply 94–234 V AC, 50/60 Hz
DC power supply 12 V DC
Power consumption 60 W
Dimensions (H × W × D) 99 × 140 × 175 mm
Weight Approx. 1.8 kg
Manufacturer calibration NIST-traceable
Calibration points −10, 0, 25, 50, 75, 100 and 122 °C
Typical applications RTD, thermocouple and thermometer calibration

Fluke Calibration 9102S or 9100S?

The Fluke Calibration 9102S and 9100S are both compact handheld dry block calibrators.

However, they are designed for different temperature ranges.

Specification Fluke Calibration 9102S Fluke Calibration 9100S
Temperature range −10 °C to +122 °C +35 °C to +375 °C
Temperature accuracy ±0.25 °C ±0.25 °C to ±0.5 °C
Temperature stability ±0.05 °C ±0.07 °C to ±0.3 °C
Number of wells 2 Multiple fixed wells
Well depth 102 mm 102 mm
Removable inserts Yes No
Weight 1.8 kg 1 kg
RS-232 interface Yes Yes
12 V DC operation Yes No

The Fluke Calibration 9102S is particularly suitable for applications requiring temperatures below ambient temperature.

The Fluke Calibration 9100S is designed for applications requiring temperatures up to 375 °C.

The correct model should be selected according to the required temperature range, sensor dimensions and calibration uncertainty.

Calibration Service by europascal

Regular calibration is essential for maintaining reliable and traceable temperature measurements.

europascal provides professional calibration services for temperature measuring instruments and calibration equipment.

When the Fluke Calibration 9102S is used for temperature sensor calibration, the measurement uncertainty must be evaluated according to the complete measurement procedure.

Relevant uncertainty contributions may include:

  • Calibration block temperature accuracy
  • Temperature stability
  • Temperature uniformity
  • Reference thermometer calibration uncertainty
  • Thermometer readout uncertainty
  • Sensor immersion effects
  • Thermal contact between the sensor and calibration insert
  • Measurement repeatability
  • Temperature drift during measurement

The individual uncertainty contributions must be evaluated carefully to avoid double-counting effects already included in the manufacturer’s specifications.

For professional calibration services and metrological traceability, visit the europascal Calibration Service.

Why Choose the Fluke Calibration 9102S?

The Fluke Calibration 9102S combines accurate temperature calibration performance with compact and portable construction.

Its temperature range from −10 °C to +122 °C covers numerous industrial and laboratory applications.

The ability to generate temperatures below ambient temperature makes it particularly suitable for refrigeration, environmental monitoring and temperature-controlled processes.

Temperature accuracy of ±0.25 °C and stability of ±0.05 °C provide reliable conditions for routine sensor calibration.

The instrument weighs only 1.8 kg, making it suitable for mobile calibration applications.

Two calibration wells allow a reference thermometer and a device under test to be used simultaneously.

Removable inserts provide flexibility when calibrating sensors with different diameters.

Fast heating and cooling times help reduce waiting periods between calibration points.

The integrated RS-232 interface and optional 12 V DC operation provide additional flexibility for field and laboratory applications.

For calibration technicians, maintenance engineers and industrial users requiring a portable low-temperature dry block calibrator, the Fluke Calibration 9102S provides an excellent combination of accuracy, efficiency and convenience.

europascal supports customers with professional temperature calibration equipment, technical advice and calibration services.

Typical Applications for the Fluke Calibration 9102S

Typical applications include:

  • Temperature sensor calibration
  • Pt100 calibration
  • Pt1000 calibration
  • RTD calibration
  • Thermocouple calibration
  • Digital thermometer verification
  • Dial thermometer calibration
  • Temperature switch testing
  • Refrigeration system maintenance
  • Environmental monitoring
  • Temperature-controlled storage
  • Pharmaceutical manufacturing
  • Food processing
  • Industrial process instrumentation
  • Preventive maintenance
  • Commissioning
  • Field calibration
  • Calibration laboratories
  • Industrial quality assurance
  • Temperature metrology

The combination of excellent temperature stability, low-temperature capability, removable inserts and portable construction makes the Fluke Calibration 9102S a professional solution for demanding temperature calibration applications.

Find more Fluke Calibration products here.

Manufacturer information for the Fluke Calibration 9102S can be found on the official Fluke Calibration website.

Download Datasheet

Messbereich

Temperaturbereich

Funktion

Genauigkeit

Stabilität

Schnittstelle

Strom-versorgung

Bauart

Other Products

Scroll to Top

Request a Quote Now!

Download Product Datasheet

Enter your email address below to access the official product datasheet, including technical specifications, measurement ranges, product features, and performance details.