AMETEK MTC-650 Robust Marine Temperature Calibrator

The AMETEK MTC-650 is a robust marine dry block temperature calibrator with a range from 28 °C to 650 °C. Featuring fast heating in just 18 minutes, temperature stability of ±0.1 °C and DNV type approval, it provides reliable performance for maritime and industrial temperature calibration. Ideal for calibrating RTDs, thermocouples and temperature switches aboard ships, offshore installations and industrial facilities.

The AMETEK MTC-650 is a professional marine temperature calibrator designed for accurate, reliable and efficient temperature sensor calibration in maritime environments, industrial facilities and calibration laboratories.

With a temperature range from 28 °C to 650 °C, temperature stability of ±0.1 °C and a one year accuracy specification of ±0.9 °C, the AMETEK MTC-650 provides dependable performance for demanding temperature calibration applications.

The instrument combines a robust construction with fast heating technology, intuitive operation and advanced temperature control.

With a heating time of approximately 18 minutes from 23 °C to 650 °C, the AMETEK MTC-650 significantly reduces waiting times during calibration procedures.

The calibrator is particularly suitable for calibrating resistance temperature detectors, Pt100 sensors, thermocouples, temperature switches and industrial temperature measuring instruments.

Its compact design, interchangeable calibration inserts, automatic temperature stepping and USB communication interface make it ideal for maintenance technicians and calibration specialists.

The AMETEK MTC-650 was specifically developed for applications aboard ships and offshore installations.

Its DNV type approval makes it particularly suitable for maritime calibration applications.

europascal provides professional temperature calibration equipment, technical advice and calibration services.

For more information, visit the europascal Calibration Service.

Your Benefits at a Glance

The AMETEK MTC-650 combines accurate temperature generation with reliable operation and convenient handling.

Its main advantages include:

  • Temperature range from 28 °C to 650 °C
  • One year temperature accuracy of ±0.9 °C
  • Three year temperature accuracy of ±1.8 °C
  • Excellent temperature stability of ±0.1 °C
  • Radial temperature homogeneity of 0.1 °C
  • Fast heating to 650 °C in approximately 18 minutes
  • Cooling from 650 °C to 100 °C in approximately 39 minutes
  • Typical stabilization time of 8 minutes
  • MVI technology for improved resistance to mains voltage fluctuations
  • Interchangeable calibration inserts
  • Calibration well diameter of 26 mm
  • Immersion depth of 115 mm
  • Automatic temperature stepping
  • Automatic temperature switch testing
  • Intuitive user interface
  • Color display with temperature status indication
  • USB communication interface
  • Compatible with JofraCal calibration software
  • DNV type approval for maritime applications
  • Compact and robust construction
  • Weight of approximately 6.1 kg
  • Suitable for laboratory and field calibration

Ideal for Maritime Temperature Calibration

The AMETEK MTC-650 was specifically developed for temperature calibration aboard ships and offshore installations.

Reliable temperature measurements are essential for the safe and efficient operation of marine engines, propulsion systems and auxiliary equipment.

Temperature sensors are used throughout marine installations to monitor critical operating conditions.

Typical applications include:

  • Marine diesel engines
  • Exhaust gas temperature monitoring
  • Lubricating oil systems
  • Cooling water systems
  • Fuel oil systems
  • Steam systems
  • Hydraulic equipment
  • Bearings
  • Heat exchangers
  • Auxiliary machinery
  • Industrial heating systems

Regular calibration helps maintain reliable temperature measurements and supports preventive maintenance.

The AMETEK MTC-650 allows technicians to perform temperature calibration directly at the installation site.

This reduces the need to transport temperature sensors to an external calibration laboratory.

Temperature Range from 28 °C to 650 °C

The AMETEK MTC-650 provides a temperature calibration range of:

28 °C to 650 °C

The minimum achievable temperature depends on the ambient temperature.

At an ambient temperature of 23 °C, the minimum calibration temperature is approximately 28 °C.

The manufacturer specifies a minimum calibration temperature approximately 5 °C above ambient temperature.

Typical calibration points include:

  • 50 °C
  • 100 °C
  • 150 °C
  • 200 °C
  • 250 °C
  • 300 °C
  • 400 °C
  • 500 °C
  • 600 °C
  • 650 °C

This wide temperature range makes the AMETEK MTC-650 suitable for numerous industrial and maritime temperature measurement applications.

The instrument is particularly useful for calibrating sensors operating at elevated temperatures.

Temperature Accuracy

The AMETEK MTC-650 provides reliable temperature accuracy over its operating range.

The manufacturer specifies:

One year accuracy: ±0.9 °C

Three year accuracy: ±1.8 °C

These specifications describe the performance of the internal temperature reference under the manufacturer’s defined conditions.

The three year accuracy specification supports applications where longer calibration intervals are appropriate.

The calibration interval should always be selected according to the application, required measurement uncertainty, historical calibration results and applicable quality requirements.

The manufacturer’s accuracy specification must not be confused with the expanded measurement uncertainty stated on an individual calibration certificate.

Excellent Temperature Stability

The AMETEK MTC-650 provides temperature stability of:

±0.1 °C

Temperature stability describes the variation of the calibration block temperature over time under defined operating conditions.

The manufacturer evaluates stability after the stability indicator has been active for 10 minutes.

The measurement period is 30 minutes.

Stable temperature conditions are essential for reliable temperature sensor calibration.

The AMETEK MTC-650 provides a controlled temperature environment for routine calibration and verification procedures.

MVI Technology for Stable Temperature Control

The AMETEK MTC-650 features MVI technology.

MVI stands for Mains power Variance Immunity.

This technology helps maintain stable temperature control when the mains supply voltage fluctuates.

Voltage fluctuations can affect the heating performance of conventional temperature calibrators.

MVI technology continuously monitors the power supply and helps maintain consistent energy delivery to the heating elements.

This is particularly useful aboard ships, where electrical supply conditions may vary.

The technology improves the reliability of temperature calibration under demanding operating conditions.

Fast Heating Performance

The AMETEK MTC-650 features an efficient heating system.

The manufacturer specifies a typical heating time of:

18 minutes from 23 °C to 650 °C

This allows the calibrator to reach its maximum temperature quickly.

Fast heating is particularly useful when performing multi-point calibration procedures.

Short heating times reduce waiting periods and improve calibration efficiency.

Actual heating performance depends on ambient conditions, sensor loading and the selected calibration insert.

Efficient Cooling Performance

The AMETEK MTC-650 also provides efficient cooling performance.

Typical cooling times include:

Temperature Change Cooling Time
650 °C to 100 °C 39 minutes
100 °C to 50 °C 18 minutes

These cooling times allow technicians to perform calibration procedures with increasing and decreasing temperature sequences.

This is particularly useful when investigating temperature sensor hysteresis.

The actual cooling time depends on operating conditions and the thermal loading of the calibration block.

Short Stabilization Time

The AMETEK MTC-650 features a typical stabilization time of:

8 minutes

This describes the time required for the calibration block to stabilize under specified conditions.

The stabilization time of the device under test must also be considered.

Large temperature sensors or sensors with slow thermal response may require additional time before reliable measurements can be recorded.

For demanding calibration procedures, sufficient thermal equilibrium should be verified before recording the measurement results.

Excellent Radial Temperature Homogeneity

The AMETEK MTC-650 provides radial temperature homogeneity of:

0.1 °C

This specification describes temperature differences between calibration holes under defined conditions.

Good radial temperature homogeneity is particularly important when calibrating several temperature sensors simultaneously.

It helps minimize temperature differences between the reference thermometer and the devices under test.

The actual calibration uncertainty also depends on sensor geometry, immersion depth and thermal contact.

Interchangeable Calibration Inserts

The AMETEK MTC-650 uses interchangeable calibration inserts.

These allow temperature sensors with different diameters to be accommodated within the calibration block.

The manufacturer specifies:

Specification Value
Calibration well diameter 26 mm
Insert outer diameter 25.7 mm
Insert length 120 mm
Immersion depth 115 mm

Different insert configurations are available.

The appropriate insert should be selected according to the dimensions of the temperature sensor.

Good thermal contact between the sensor and insert helps reduce measurement errors.

Excessive clearance can increase temperature differences between the calibration block and the sensing element.

Automatic Temperature Stepping

The AMETEK MTC-650 supports automatic temperature stepping.

Users can define temperature setpoints and holding times.

The calibrator then performs the programmed temperature sequence automatically.

This function is particularly useful for repetitive calibration procedures.

Automatic stepping reduces manual intervention and improves calibration efficiency.

For maritime applications, technicians can prepare a calibration sequence and allow the instrument to complete the programmed temperature changes.

Automatic Temperature Switch Testing

The AMETEK MTC-650 supports automatic temperature switch testing.

Temperature switches are widely used in marine engines and industrial control systems.

They activate or deactivate electrical contacts when a defined temperature is reached.

The AMETEK MTC-650 can generate controlled temperature changes while monitoring the switch contact.

This allows switching points and hysteresis to be determined.

The function is particularly useful for preventive maintenance and verification of temperature protection systems.

Intuitive User Interface

The AMETEK MTC-650 features an intuitive user interface.

The instrument uses a convenient operating concept with dedicated function keys.

Important calibration functions can be accessed directly.

The display provides information about:

  • Set temperature
  • Actual temperature
  • Temperature stability
  • Heating and cooling status
  • Calibration progress
  • Instrument operating status

The interface is designed for convenient operation in industrial and maritime environments.

USB Communication and Calibration Software

The AMETEK MTC-650 includes a USB 2.0 communication interface.

This interface allows communication with compatible calibration software.

The instrument supports JofraCal calibration software.

The software can assist with calibration procedures and documentation.

Computer-assisted calibration helps improve consistency and reduces repetitive manual operations.

The available functions depend on the software version and the connected equipment.

DNV Type Approval

The AMETEK MTC-650 has DNV type approval for maritime applications.

DNV is an internationally recognized classification society.

The type approval confirms that the instrument has been assessed according to the applicable requirements stated in the approval certificate.

This makes the AMETEK MTC-650 particularly suitable for use aboard ships and offshore installations.

The approval is an important advantage for maritime operators requiring suitable calibration equipment for onboard maintenance.

Extended Calibration Intervals

The AMETEK MTC-650 offers specifications for one year and three year calibration intervals.

The manufacturer specifies:

Calibration Interval Temperature Accuracy
1 year ±0.9 °C
3 years ±1.8 °C

A longer calibration interval can reduce the frequency of equipment transportation and recalibration.

This is particularly useful for ships operating internationally.

However, the appropriate calibration interval must be determined according to the measurement requirements and quality management procedures.

A three year manufacturer specification does not automatically establish a suitable three year interval for every application.

Compact and Portable Construction

The AMETEK MTC-650 is designed for mobile temperature calibration.

The instrument weighs approximately:

6.1 kg

Its dimensions are:

248 × 148 × 305 mm

The compact construction makes it suitable for transportation between different measurement locations.

A protective carrying case is available.

The carrying case provides storage space for the calibrator, calibration inserts, accessories and documentation.

This is particularly useful for maritime maintenance technicians who need to transport calibration equipment between different areas of a ship.

Technical Highlights

Specification AMETEK MTC-650
Manufacturer AMETEK
Model MTC-650
Product type Marine Temperature Calibrator
Temperature range 28 °C to 650 °C
Minimum temperature Ambient temperature +5 °C
One year accuracy ±0.9 °C
Three year accuracy ±1.8 °C
Temperature stability ±0.1 °C
Radial homogeneity 0.1 °C
Display resolution 1 °C or 0.1 °C
Heating time, 23 °C to 650 °C 18 minutes
Cooling time, 650 °C to 100 °C 39 minutes
Cooling time, 100 °C to 50 °C 18 minutes
Typical stabilization time 8 minutes
Calibration well diameter 26 mm
Immersion depth 115 mm
Insert outer diameter 25.7 mm
Insert length 120 mm
Temperature control MVI technology
Automatic temperature stepping Yes
Automatic switch testing Yes
Communication interface USB 2.0
Calibration software JofraCal
DNV type approval Yes
Operating temperature 0 °C to 50 °C
Storage temperature −20 °C to 50 °C
Relative humidity 5% to 90% RH, non-condensing
Power supply 115 V or 230 V AC
Maximum power consumption 1150 VA
Protection rating IP10
Dimensions 248 × 148 × 305 mm
Weight Approx. 6.1 kg

Calibration of Pt100 and RTD Sensors

The AMETEK MTC-650 is suitable for calibrating resistance temperature detectors.

Typical applications include:

  • Pt100 calibration
  • Pt1000 calibration
  • Industrial RTD calibration
  • Temperature probe verification
  • Temperature indicator testing

The sensor is inserted into a suitable calibration insert.

The calibration block generates a controlled temperature.

The temperature indicated by the device under test can then be compared with the reference temperature.

For demanding applications, a suitable external reference thermometer can be used.

The AMETEK MTC-650 provides the temperature source. Electrical resistance measurement requires a suitable external instrument.

Calibration of Thermocouples

The AMETEK MTC-650 can also be used for thermocouple calibration.

Thermocouples are widely used in marine engines and industrial applications requiring elevated temperatures.

Typical applications include exhaust gas temperature monitoring and industrial heating systems.

The thermocouple is inserted into the calibration block and allowed to stabilize.

Its indicated temperature can then be compared with the reference temperature.

For accurate thermocouple calibration, reference junction compensation and the measurement uncertainty of the readout must be considered.

Calibration Service by europascal

Regular calibration is essential for maintaining reliable and traceable temperature measurements.

europascal provides professional calibration services for temperature measuring instruments and calibration equipment.

When the AMETEK MTC-650 is used for temperature sensor calibration, the measurement uncertainty must be evaluated according to the complete calibration procedure.

Relevant uncertainty contributions include:

  • Calibration of the temperature reference
  • Temperature stability
  • Axial temperature distribution
  • Radial temperature distribution
  • Sensor immersion depth
  • Thermal contact between sensor and insert
  • Loading effects
  • Reference thermometer uncertainty
  • Measurement repeatability

The uncertainty evaluation should follow the applicable calibration procedure and relevant metrological guidelines.

For professional calibration services and metrological traceability, visit the europascal Calibration Service.

Why Choose the AMETEK MTC-650?

The AMETEK MTC-650 combines reliable temperature calibration with robust construction and convenient operation.

Its temperature range from 28 °C to 650 °C covers numerous industrial and maritime applications.

Fast heating allows the instrument to reach 650 °C in approximately 18 minutes.

Temperature stability of ±0.1 °C provides reliable conditions for routine calibration procedures.

MVI technology helps maintain stable operation when mains voltage fluctuations occur.

The instrument’s DNV type approval makes it particularly suitable for maritime applications.

Automatic temperature stepping and temperature switch testing simplify routine calibration tasks.

The compact design and weight of approximately 6.1 kg make the calibrator suitable for mobile use.

For marine engineers, maintenance technicians and industrial users requiring a reliable temperature calibrator, the AMETEK MTC-650 provides an excellent combination of performance, portability and convenience.

europascal supports customers with professional calibration equipment, technical advice and calibration services.

Typical Applications for the AMETEK MTC-650

The AMETEK MTC-650 is suitable for numerous professional temperature calibration applications.

Typical applications include:

  • Marine temperature calibration
  • Pt100 calibration
  • Pt1000 calibration
  • RTD calibration
  • Thermocouple calibration
  • Temperature switch testing
  • Marine diesel engines
  • Exhaust gas temperature monitoring
  • Lubricating oil systems
  • Cooling water systems
  • Fuel oil systems
  • Steam systems
  • Hydraulic systems
  • Offshore installations
  • Ship maintenance
  • Industrial process instrumentation
  • Preventive maintenance
  • Calibration laboratories
  • Industrial quality assurance
  • Temperature metrology
  • Field calibration

The combination of fast heating, reliable temperature stability, MVI technology and DNV type approval makes the AMETEK MTC-650 a professional solution for demanding maritime and industrial temperature calibration applications.

Find more temperature calibration equipment at europascal.

Manufacturer information for the AMETEK MTC-650 can be found on the official AMETEK website.

Download Datasheet

Messbereich

Temperaturbereich

Funktion

Genauigkeit

Stabilität

Schnittstelle

Strom-versorgung

Bauart

Other Products

Scroll to Top

Request a Quote Now!

Download Product Datasheet

Enter your email address below to access the official product datasheet, including technical specifications, measurement ranges, product features, and performance details.