Magnum Pro M-10 Powerful Hydraulic Calibration Hand Pump

The Magnum Pro M-10 is a powerful hydraulic calibration hand pump for professional pressure testing and comparison calibration up to 10,000 psi / 700 bar. Its fully adjustable stroke control enables quick priming and efficient pressure generation, while patented triple filtration, a built-in pressure relief valve and a shatter-resistant reservoir provide reliable operation. Weighing only approximately 1.36 kg, the M-10 is ideal for laboratory and field calibration.

Magnum Pro M-10 is a powerful hydraulic calibration hand pump designed for professional generation of hydraulic pressure up to 10,000 psi / 700 bar. Its compact and rugged construction makes the M-10 an ideal pressure source for calibration, testing and adjustment of pressure gauges, digital pressure indicators, transmitters, sensors and other pressure measuring instruments.

A key feature of the Magnum Pro M-10 is its fully adjustable stroke control. The pump stroke can be adapted to the application, allowing quick priming, convenient pumping and efficient pressure generation. This makes it possible to generate high hydraulic pressures manually without requiring an electric pressure controller or an external hydraulic power unit.

The M-10 is designed for demanding field and laboratory applications. Ergonomically shaped cushioned handles provide comfortable operation, while a patented triple filtration system protects the internal pump mechanism against contamination. Oversized check valves support smooth and controlled pressure generation.

A built-in pressure relief valve protects against accidental overpressurization, while the vent control is protected by a patented cage. The hydraulic reservoir is manufactured from shatter-resistant material and the pressure-carrying components use robust materials including stainless steel.

With a weight of only approximately 3 lb / 1.36 kg, the Magnum Pro M-10 provides an excellent combination of high pressure capability and portability.

The pump is compatible with a wide range of hydraulic fluids, oils and water. For calibration applications, the manufacturer specifically recommends suitable clean media such as distilled water or mineral-based hydraulic oil.

At europascal, the Magnum Pro M-10 can be combined with suitable precision digital pressure references to create a complete manual pressure calibration system. For professional calibration and metrological traceability, visit the europascal Calibration Service.

Your Benefits at a Glance

The Magnum Pro M-10 combines high-pressure capability with rugged construction and convenient manual operation.

Key advantages include:

  • Hydraulic calibration hand pump
  • Pressure generation from 0 to 10,000 psi
  • Maximum pressure 700 bar
  • Fully adjustable stroke control
  • Fast pressure generation
  • Quick priming function
  • Ergonomically designed cushioned handles
  • Patented triple filtration system
  • Built-in pressure relief valve
  • Patented protective cage around the vent control
  • Shatter-resistant hydraulic reservoir
  • Oversized check valves
  • Smooth and controlled pressure generation
  • Stainless steel pressure fittings
  • Compatible with hydraulic fluids, oils and water
  • Suitable for distilled water
  • Suitable for mineral-based hydraulic oil
  • Two pressure ports
  • 1/4″ pressure connections
  • Compact handheld construction
  • Approx. 1.36 kg weight
  • Suitable for field and laboratory applications
  • Made in the USA
  • Suitable for professional comparison calibration

Pressure Generation up to 700 bar

The Magnum Pro M-10 generates hydraulic pressure from:

0 to 10,000 psi

or approximately:

0 to 700 bar.

This pressure range makes the M-10 suitable for a broad range of industrial and calibration applications.

Typical devices under test include:

  • Analog pressure gauges
  • Digital pressure gauges
  • Pressure transmitters
  • Pressure transducers
  • Pressure sensors
  • Pressure switches

The M-10 generates the hydraulic pressure required for testing these instruments.

Hydraulic Calibration Hand Pump

The Magnum Pro M-10 is a:

hydraulic calibration hand pump.

Pressure is generated manually by operating the pump handles.

No electrical power supply is required.

This makes the M-10 particularly suitable for applications where portability and independence from an external power source are important.

Pressure Generator – Not a Pressure Reference

The Magnum Pro M-10 generates pressure but does not independently measure the reference pressure.

For calibration applications, a separate reference pressure instrument is required.

A typical calibration system consists of:

Magnum Pro M-10 + Reference Pressure Gauge + Device Under Test

The M-10 generates the hydraulic pressure.

The reference instrument measures the generated pressure.

The device under test is exposed to the same pressure.

Its indication can then be compared directly with the reference value.

Comparison Calibration

The comparison principle provides a flexible solution for professional pressure calibration.

For example, a precision digital pressure gauge can be connected as the reference.

A conventional mechanical pressure gauge can then be connected as the device under test.

Pressure is generated with the Magnum Pro M-10 and adjusted to the required calibration points.

The DUT indication is compared with the reference instrument at each measurement point.

Fully Adjustable Stroke Control

One of the distinctive features of the Magnum Pro M-10 is its:

fully adjustable stroke control.

The pump stroke can be adjusted according to the required pressure generation characteristics.

This provides several advantages:

  • Quick priming
  • Easier initial pressure generation
  • Efficient high-pressure generation
  • Improved operator control

The adjustable stroke helps optimize operation across the wide pressure range of the pump.

Quick Priming

Before high hydraulic pressure can be generated efficiently, the pressure system must be filled correctly with the selected test medium.

The M-10 incorporates a:

priming feature.

This simplifies preparation of the hydraulic pressure system and helps the operator establish the initial pressure before proceeding to higher calibration pressures.

Ergonomic Handles

Generating pressures up to 700 bar manually requires a pump that is comfortable to operate.

The Magnum Pro M-10 therefore features:

contoured cushioned handles.

The ergonomic handle design improves operator comfort during repeated pumping.

This is particularly useful when multiple pressure instruments must be calibrated during one working day.

Patented Triple Filtration

Contamination is one of the major causes of problems in hydraulic pressure generation equipment.

The Magnum Pro M-10 therefore incorporates a:

patented triple filtration system.

The filtration system is designed to help prevent pump failures caused by dirt and contamination.

This is particularly useful for field applications where the pressure pump may be exposed to less controlled environmental conditions than in a calibration laboratory.

Protection Against Contamination

Clean hydraulic media are important for reliable operation of any high-pressure calibration pump.

Particles can affect:

  • Valves
  • Seals
  • Pressure connections
  • Internal moving components

The integrated filtration concept of the M-10 provides additional protection for the internal hydraulic system.

Clean test media should nevertheless always be used.

Built-In Pressure Relief Valve

The Magnum Pro M-10 incorporates a:

built-in pressure relief valve.

The pressure relief valve is designed to protect the system against accidental overpressurization.

This is particularly important because the pump is capable of generating pressures as high as:

10,000 psi / 700 bar.

The maximum permissible pressure of the pump and every connected component must always be observed.

Protected Vent Control

The M-10 incorporates a patented:

protective cage around the vent knob.

The protective structure helps prevent accidental operation or mechanical damage to the vent control.

This contributes to the rugged design of the pump for field and workshop applications.

Shatter-Resistant Reservoir

The hydraulic medium is stored in an integrated:

shatterproof reservoir.

This provides greater durability than a conventional fragile reservoir design.

The reservoir allows the hydraulic medium to be carried directly with the pump, eliminating the need for a separate external fluid reservoir during normal operation.

Oversized Check Valves

The Magnum Pro M-10 uses:

oversized check valves.

These valves are designed to provide smooth and controlled pump operation.

Reliable check-valve operation is particularly important when pressure must be generated repeatedly over a wide pressure range.

Compatible Pressure Media

The Magnum Pro M-10 is compatible with:

  • Hydraulic fluids
  • Hydraulic oils
  • Water

For typical calibration applications, clean media should be used.

Documented recommendations include:

distilled water

or:

mineral-based hydraulic oil.

The selected medium must always be compatible with the device under test and all components in the pressure system.

Distilled Water

Distilled water can be useful when hydraulic oil contamination must be avoided.

This may be relevant when calibrating pressure instruments intended for water-based systems.

The pressure system should be cleaned appropriately when changing between different pressure media.

Hydraulic Oil

Mineral-based hydraulic oil can be used for conventional hydraulic pressure calibration.

Oil provides suitable lubrication for many high-pressure applications and is commonly used with industrial hydraulic pressure gauges, sensors and transmitters.

The medium requirements of the DUT should always be checked before connection.

Non-Oil-Based Internal Lubricant

An interesting design feature of the M-10 is that a:

non-oil-based lubricant

is used on the pump’s moving components.

This is part of the manufacturer’s design approach for reliable pump operation.

Two Pressure Ports

The Magnum Pro M-10 provides:

two pressure ports.

This makes the pump particularly convenient for comparison calibration.

One port can be used for the reference pressure gauge.

The second port can be used for the device under test or for a high-pressure hose leading to the DUT.

1/4″ Pressure Connections

The documented connection specification is:

2 × 1/4″ NPT/BSP pressure ports.

Depending on the exact configuration and supplied adapters, the pump can therefore be integrated with commonly used industrial pressure fittings.

Suitable adapters can be used for other connection types.

Pressure Gauge Calibration

The Magnum Pro M-10 is particularly suitable for pressure gauge calibration.

A precision reference gauge and the pressure gauge under test are connected to the hydraulic pressure system.

The operator then generates defined calibration pressures.

A typical measurement sequence may include:

0% → 20% → 40% → 60% → 80% → 100%

of the calibration range.

The pressure can subsequently be reduced through the same measurement points.

This allows the indication error of the pressure gauge to be evaluated over the complete calibration range.

Digital Pressure Gauge Calibration

The M-10 can also be combined with a precision digital pressure reference for calibration of another digital pressure gauge.

The M-10 generates the pressure while the reference instrument determines the actual pressure value.

This creates a compact manual calibration system for field or laboratory applications.

Pressure Transmitter Calibration

The Magnum Pro M-10 can be used as the hydraulic pressure source for pressure transmitter calibration.

A complete setup may consist of:

M-10 + Pressure Reference + Electrical Calibrator + Pressure Transmitter

The M-10 generates pressure.

The reference gauge measures pressure.

The electrical calibrator measures the transmitter output.

For a conventional process transmitter, this is often:

4 to 20 mA.

This allows the relationship between applied pressure and electrical output to be evaluated.

Pressure Sensor Calibration

Pressure sensors and transducers can be tested using the same basic arrangement.

The M-10 generates the hydraulic input pressure while a suitable reference instrument measures the actual pressure.

The sensor output can then be recorded at each calibration point.

Pressure Switch Testing

The Magnum Pro M-10 can also provide the hydraulic pressure required for pressure switch testing.

Pressure is increased until the switch changes state.

The switching pressure is determined from the reference pressure instrument.

Pressure can subsequently be reduced until the switch resets.

This allows determination of:

  • Switching pressure
  • Reset pressure
  • Switching hysteresis

Lightweight High-Pressure Pump

One of the strongest advantages of the Magnum Pro M-10 is its low weight.

The pump weighs approximately:

3 lb / 1.36 kg.

This is remarkably compact for a manually operated hydraulic pressure source capable of generating up to 700 bar.

The low weight makes the pump particularly attractive for field calibration.

Portable Field Calibration

The compact construction allows technicians to transport the Magnum Pro M-10 directly to the measurement location.

Instead of removing a pressure instrument and transporting it to a laboratory, suitable devices can be tested at their installation location.

A portable system can consist of:

  • Magnum Pro M-10
  • Precision digital pressure reference
  • High-pressure hose
  • Connection adapters
  • Test fluid
  • Carrying case

This provides a flexible solution for maintenance and service applications.

Laboratory Calibration

The M-10 is equally suitable for laboratory use.

Combined with a suitable precision pressure reference, the pump provides a straightforward manual comparison system for routine hydraulic calibration.

No compressed-air supply, hydraulic power unit or electrical pressure controller is required.

M-10KT Calibration Kit

In addition to the standalone M-10, Magnum Pro offers the:

M-10KT

kit configuration.

The kit expands the basic pressure pump with accessories required for portable calibration work.

Depending on the configuration, the kit includes components such as:

  • Magnum Pro M-10 pump
  • Protective carrying case
  • High-pressure hose
  • Pressure fittings
  • Filters
  • Test point
  • Adapter
  • Fluid bottle

The kit is particularly convenient for field calibration.

Rugged Construction

The Magnum Pro M-10 uses robust materials including:

  • Stainless steel fittings
  • Anodized aluminum housing
  • Polyurethane
  • PTFE
  • Nitrile O-rings
  • Durable plastic and rubber handle components

This combination is designed for repeated professional use.

Technical Highlights

Feature Magnum Pro M-10
Product type Hydraulic Calibration Hand Pump
Pressure range 0 to 10,000 psi
Maximum pressure 700 bar
Pressure generation Manual
Stroke control Fully adjustable
Priming function Yes
Filtration Patented triple filtration
Pressure relief valve Integrated
Reservoir Shatter-resistant
Check valves Oversized
Pressure media Hydraulic fluids, oils and water
Recommended media Distilled water / mineral-based hydraulic oil
Pressure ports 2
Connections 1/4″ NPT/BSP
Weight Approx. 3 lb / 1.36 kg
Field use Yes
Laboratory use Yes
Reference measurement External reference required
Country of manufacture USA

M-10 vs. Pneumatic Calibration Pump

The Magnum Pro M-10 is a hydraulic pressure pump.

Hydraulic pressure generation is particularly suitable when high pressures must be produced in a compact manual system.

Pneumatic hand pumps use air or another compatible gas and are generally preferred for lower pressure ranges and applications where contamination by hydraulic fluid must be avoided.

With a maximum pressure of:

700 bar / 10,000 psi

the M-10 is designed specifically for demanding hydraulic pressure applications.

M-10 vs. Pressure Comparator

The Magnum Pro M-10 performs many of the same pressure-generation functions required for manual comparison calibration.

Its major advantage is portability.

A larger bench pressure comparator may provide additional connection options, larger fluid capacity or more elaborate pressure adjustment mechanisms.

The M-10 instead focuses on:

  • Compact dimensions
  • Low weight
  • Fast manual pressure generation
  • Field portability
  • Rugged construction

This makes it particularly suitable for mobile calibration.

Typical Applications

The Magnum Pro M-10 is suitable for:

  • Pressure gauge calibration
  • Digital pressure gauge calibration
  • Pressure transmitter calibration
  • Pressure sensor testing
  • Pressure transducer testing
  • Pressure switch testing
  • Hydraulic pressure generation
  • High-pressure comparison calibration
  • Field calibration
  • Laboratory calibration
  • Workshop calibration
  • Industrial maintenance
  • Process instrumentation
  • Production testing
  • Quality assurance
  • Hydraulic service
  • Oil and gas applications
  • Energy applications

Why Choose the Magnum Pro M-10?

The Magnum Pro M-10 combines high-pressure generation with exceptionally compact and rugged construction.

Its manually operated hydraulic system generates pressure up to 10,000 psi / 700 bar, providing sufficient capability for a broad range of industrial high-pressure calibration applications.

The fully adjustable stroke control enables quick priming and efficient pressure generation, while ergonomically designed cushioned handles improve operator comfort.

A patented triple filtration system helps protect the internal pump mechanism against contamination. Oversized check valves support smooth operation, while the integrated pressure relief valve provides protection against accidental overpressurization.

The shatter-resistant reservoir and robust materials make the pump suitable for demanding field conditions.

Compatibility with hydraulic fluids, oils and water allows the pressure medium to be selected according to the calibration application and device under test.

With two pressure ports, the M-10 can be easily integrated into a comparison calibration system consisting of the pump, a precision reference pressure gauge and the device under test.

Despite its 700 bar capability, the pump weighs only approximately 1.36 kg, making it particularly suitable for portable pressure calibration.

At europascal, the Magnum Pro M-10 can be combined with suitable reference pressure gauges, hoses and adapters to create a complete calibration solution for laboratory, workshop and field applications.

For professional calibration and metrological traceability, visit the europascal Calibration Service.

Download Datasheet

Medium

Druckbereich

Other Products

Scroll to Top

Request a Quote Now!

Download Product Datasheet

Enter your email address below to access the official product datasheet, including technical specifications, measurement ranges, product features, and performance details.