Fluke Calibration 719 is an electric pressure calibrator designed for fast, accurate and convenient calibration of pressure transmitters, pressure switches, I/P converters and other process instrumentation. Its defining feature is the integrated electric pressure pump, which allows pressure to be generated at the push of a button and enables true one-handed pressure calibration in the field.
The Fluke Calibration 719 combines pressure generation, pressure measurement, mA measurement and sourcing, and a 24 V loop power supply in one compact handheld instrument. Current models are available for 30 psi and 100 psi pressure ranges, while the internal pressure measurement provides an accuracy of 0.025% of range for six months. For applications outside the internal range, compatible Fluke 750P pressure modules considerably expand the measurement capability. Fluke
Unlike a calibrator that requires a manual pressure pump, the motorized pump of the Fluke Calibration 719 generates pressure automatically. Programmable pump limits help prevent accidental overpressure and allow target pressures to be defined. Fine pressure adjustment is supported by a precision vernier and a variable-rate bleed valve, making the instrument particularly practical for accurate transmitter calibration. Fluke
europascal supports professional pressure calibration applications and offers accredited calibration services for pressure measuring instruments. More information is available through the europascal Calibration Service. europascal’s published pressure calibration capabilities cover pneumatic and hydraulic pressure measurements from 1 Pa up to 10,000 bar, depending on the method and pressure type. europascal.de
Your Benefits at a Glance
- Integrated electric pressure pump
- Convenient one-handed pressure calibration
- 30 psi and 100 psi versions available
- Pressure measurement accuracy of 0.025% of range for six months
- 0.035% of range accuracy for a one-year calibration interval
- Measures and sources 0 to 24 mA
- mA accuracy of 0.015% of reading + 2 counts
- 0.001 mA resolution
- Integrated 24 V DC loop power
- Ideal for 4–20 mA pressure transmitters
- Suitable for I/P converter testing
- Integrated pressure switch test
- Programmable pressure pump limit
- Programmable target pressures
- Precision pressure adjustment vernier
- Variable-rate pressure release valve
- Pump cleanout ports
- Extended pressure measurement with Fluke 750P modules
- Pressure measurement with external modules up to 700 bar
- Rugged handheld construction
- Battery-powered operation
- Protective holster
- Suitable for field and laboratory calibration
- Professional calibration and service available from europascal
The principal functions and specifications are confirmed on the current official Fluke Calibration 719 product page. Fluke
Ideal for Demanding Calibration Applications
The Fluke Calibration 719 is particularly useful when pressure calibration has to be carried out efficiently at the installation site.
Typical applications include:
- Calibration of pressure transmitters
- Testing of 4–20 mA transmitters
- Pressure switch testing
- I/P converter testing
- Process valve troubleshooting
- Pneumatic pressure calibration
- Pressure sensor verification
- Maintenance of process instrumentation
- Mobile field calibration
- Laboratory pressure calibration
- Preventive maintenance
- Industrial troubleshooting
- Quality assurance
- Production and service applications
The integrated pump minimizes the amount of separate equipment that technicians need to carry. Fluke specifically positions the 719 for quick pressure calibration and process maintenance using its electrically driven pump. Fluke
Integrated Electric Pressure Pump
The major difference between the Fluke Calibration 719 and conventional handheld pressure calibrators is its built-in electric pump.
Instead of repeatedly operating a manual hand pump, the user can generate the required test pressure electrically.
This provides several practical advantages during field calibration:
- Less manual pumping
- Faster pressure generation
- Easier one-handed operation
- More convenient repeated calibration points
- Reduced effort when calibrating multiple instruments
For the 100 psi version, Fluke specifies a maximum pump pressure generation of 120 psi / approximately 8 bar. Fluke
The electric pump makes the 719 especially attractive for technicians who regularly calibrate pneumatic pressure transmitters at different locations.
Two Internal Pressure Ranges
The Fluke Calibration 719 is available in two principal configurations.
Fluke Calibration 719 30G
The 719 30G is intended for applications around the 30 psi range.
Fluke specifies:
Range: -12 to 30 psi
Metric range: approximately -850 mbar to 2.4 bar
Resolution: 0.001 psi / 0.1 mbar
6-month accuracy: 0.025% of range
1-year accuracy: 0.035% of range. Fluke
Fluke Calibration 719 100G
The 719 100G is designed for higher pneumatic pressure applications.
Fluke specifies:
Range: -12 to 100 psi
Metric range: approximately -850 mbar to 8 bar
Resolution: 0.01 psi / 1 mbar
6-month accuracy: 0.025% of range
1-year accuracy: 0.035% of range. Fluke
This allows users to select an internal measuring range appropriate for the pressure transmitters and switches they most frequently calibrate.
Pressure Accuracy of 0.025%
The Fluke Calibration 719 provides an internal pressure accuracy of:
0.025% of range for six months.
For a one-year calibration interval, the specification is:
0.035% of range. Fluke
A clearly defined pressure accuracy is essential when the 719 is used as the pressure reference during transmitter adjustment or pressure-switch testing.
The correct model should be selected so that the internal measuring range is appropriately matched to the device under test.
Measure and Source mA
The Fluke Calibration 719 does more than measure pressure.
It can both measure and source current, making it particularly useful for process instrumentation.
The electrical range is:
0 to 24 mA
with a resolution of:
0.001 mA.
The specified accuracy is:
0.015% of reading + 2 counts. Fluke
This capability allows the 719 to work with the standard 4–20 mA signals widely used by industrial pressure transmitters, valves and I/P converters.
Pressure Transmitter Calibration
A typical pressure transmitter converts an applied pressure into a 4–20 mA electrical signal.
The Fluke Calibration 719 provides several functions required for such a calibration in one device:
- Generates the pneumatic pressure
- Measures the applied pressure
- Supplies 24 V loop power
- Measures the transmitter output current
This considerably simplifies a typical field calibration setup.
Instead of using a separate pressure generator, reference pressure gauge, loop supply and current meter, the 719 combines the central functions in one portable calibrator.
Integrated 24 V Loop Power
The Fluke Calibration 719 provides an integrated:
24 V DC loop supply.
Fluke specifies the loop supply with an accuracy of ±10%. Fluke
The loop supply allows compatible two-wire transmitters to be powered during testing.
This is especially practical when the transmitter has been isolated from the plant control system or is being tested on a bench.
I/P Converter and Valve Testing
Because the Fluke Calibration 719 can source mA, it can also be used for testing devices that convert an electrical signal into a pneumatic response.
Fluke specifically identifies valves and I/P converters as applications for the mA source function. Fluke
The user can generate a defined current signal and evaluate how the connected process component responds.
This expands the 719 beyond pure pressure-transmitter calibration and makes it a useful process troubleshooting instrument.
Programmable Pump Limits
The electric pump provides programmable pressure limits.
This feature can help:
- Prevent accidental overpressure
- Protect sensitive pressure instruments
- Define suitable operating limits
- Improve repeatability during routine calibration
The operator can also program target pressure values for the pump. Fluke
This provides greater control than simply switching an electric pump on and off.
Precision Pressure Adjustment
Once the pressure is close to the desired calibration point, precise adjustment becomes important.
The Fluke Calibration 719 therefore includes a:
precision pressure adjustment vernier
for fine setting of the pressure. Fluke
This allows the operator to approach the desired calibration point more accurately after the electric pump has generated the basic pressure.
A variable-rate bleed valve additionally supports controlled pressure reduction.
Pressure Switch Testing
The Fluke Calibration 719 incorporates a dedicated pressure-switch test function.
This enables the user to determine the switching behavior of pressure switches without requiring separate measurement equipment.
The instrument is therefore suitable for checking pressure switches during:
- Preventive maintenance
- Commissioning
- Troubleshooting
- Periodic calibration
- Laboratory testing
Fluke explicitly includes pressure-switch testing among the standard functions of the 719. Fluke
Easy-to-Clean Pump System
Contamination is an important consideration for portable pressure calibrators.
Moisture or process fluids can enter a pneumatic calibration system and affect the pump.
The Fluke Calibration 719 therefore incorporates dedicated pump cleanout ports. Fluke states that this design helps reduce pump failures caused by moisture and fluid contamination and allows the pump system to be cleaned more easily. Fluke
This is especially valuable for instruments used regularly in industrial field service.
Extended Pressure Measurement with Fluke 750P Modules
The internal sensor does not limit the Fluke Calibration 719 to only its 30 psi or 100 psi range.
Fluke states that the 719 supports external 750P Series pressure modules, significantly extending its pressure measurement capability. Fluke
The current 750P family includes high-pressure modules such as:
750P29: up to 200 bar
750P30: up to 340 bar
750P31: up to 700 bar / 10,000 psi. Fluke
This modular concept enables the 719 to cover a much wider range of pressure-measurement applications when an appropriate external pressure source is used.
The electric pump inside the 719 does not generate 700 bar. The extended range refers to measurement using an external pressure module and a suitable external pressure source.
Compact Handheld Design
The Fluke Calibration 719 is designed for mobile field use.
Fluke specifies dimensions of approximately:
60 × 87 × 210 mm
and a weight of approximately:
912 g. Fluke
The compact format allows the complete instrument to be carried conveniently between different measurement locations.
A protective yellow holster provides additional protection during industrial service work.
Battery-Powered Operation
The Fluke Calibration 719 operates from:
two 9 V alkaline batteries.
Under the test conditions stated by Fluke, battery life is approximately 12 hours, including transmitter current operation and defined pump cycles. Fluke
Battery operation means that the instrument does not require a mains connection during mobile calibration work.
Environmental Specifications
The specified operating temperature range is:
-10 °C to 55 °C.
The storage temperature range is:
-30 °C to 60 °C.
Fluke also specifies a 1 m drop test, supporting the intended use of the instrument as a rugged portable process calibrator. Fluke
Pump Lifetime
For the integrated electric pump, Fluke specifies:
5,000 pump cycles between rebuilds
and a total pump life of:
20,000 calibration cycles. Fluke
The cleanout-port concept is intended to help reduce failures caused by moisture and contamination and thereby support reliable operation in field applications.
Technical Highlights
Model: Fluke Calibration 719
Device type: Electric Pressure Calibrator
Internal versions: 30G and 100G
Pressure generation: Integrated electric pump
Maximum pump generation: Up to 120 psi / approx. 8 bar on the 100G model
Pressure accuracy: 0.025% of range for 6 months
One-year pressure accuracy: 0.035% of range
Current range: 0 to 24 mA
Current resolution: 0.001 mA
Current accuracy: 0.015% reading + 2 counts
Current function: Measure and source
Loop supply: 24 V DC
External pressure modules: Fluke 750P Series
External measurement range: Up to 700 bar with suitable module
Pressure switch test: Yes
Pump limit: Programmable
Fine adjustment: Precision vernier
Power supply: 2 × 9 V alkaline batteries
Dimensions: 60 × 87 × 210 mm
Weight: Approx. 912 g
Operating temperature: -10 °C to 55 °C
The technical data are based on the current manufacturer specifications published by Fluke. Fluke
Technical Data
| Feature | Fluke Calibration 719 |
|---|---|
| Device type | Electric Pressure Calibrator |
| Models | 719 30G, 719 100G |
| 30G range | -12 to 30 psi |
| 100G range | -12 to 100 psi |
| Pressure accuracy, 6 months | 0.025% of range |
| Pressure accuracy, 1 year | 0.035% of range |
| Integrated pump | Electric |
| Max. pump pressure, 100G | 120 psi / approx. 8 bar |
| mA range | 0 to 24 mA |
| mA resolution | 0.001 mA |
| mA accuracy | 0.015% reading + 2 counts |
| mA function | Measure and source |
| Loop power | 24 V DC |
| Pressure switch test | Yes |
| External modules | Fluke 750P Series |
| External pressure measurement | Up to 700 bar |
| Dimensions | 60 × 87 × 210 mm |
| Weight | Approx. 912 g |
| Battery | 2 × 9 V alkaline |
| Operating temperature | -10 °C to 55 °C |
| Storage temperature | -30 °C to 60 °C |
| Calibrator warranty | 3 years |
| Pump warranty | 1 year |
Why Choose the Fluke Calibration 719?
The Fluke Calibration 719 is particularly suitable for users who want to reduce the amount of equipment required for pneumatic process calibration.
The integrated electric pump eliminates much of the manual pumping normally associated with handheld pressure calibration. Combined with programmable pressure limits, target-pressure control, a precision vernier and a variable bleed valve, it provides a convenient solution for repeatedly approaching calibration points.
At the same time, the instrument measures and sources current with high accuracy and provides 24 V loop power. This makes it possible to perform complete pressure transmitter calibrations using a single handheld instrument.
The two internal pressure versions cover common pneumatic applications, while optional Fluke 750P pressure modules extend pressure measurement capability up to 700 bar when used with an appropriate external pressure source.
For technicians performing regular calibrations of pressure transmitters, switches, valves and I/P converters, the Fluke Calibration 719 combines portability, electrical process functions and motorized pressure generation in a practical field instrument.
europascal is an authorized Fluke Calibration service center for pressure and flow products in the EMEA region and offers professional support for Fluke Calibration equipment. europascal.de
Typical Applications with the Fluke Calibration 719
The Fluke Calibration 719 is particularly suitable for pressure transmitter calibration, pressure switch testing, I/P converter testing, process valve troubleshooting and pneumatic pressure measurements.
europascal can support users with the selection of suitable pressure calibrators, external pressure modules and pressure-generation equipment. For traceable calibration of existing instruments, use the europascal Calibration Service. europascal.de
Further professional pressure calibration equipment is available in the pressure technology section at europascal.
Further products from Fluke Calibration can be found here.
Manufacturer information about the Fluke Calibration 719 can be found on the official Fluke manufacturer website.





