europascal

[wpml_language_switcher type="widget" flags="1" native="0" translated="1"]
[wpml_language_switcher type="widget" flags="1" native="0" translated="1"]
Additel ADT 875-1210 Reference Calibration Furnace

The Additel ADT 875-1210 Reference Calibration Furnace provides high precision thermocouple calibration from 100 °C to 1,210 °C. As the reference model of Additel’s high temperature series, it combines patented multi-zone temperature control, display accuracy down to ±1.5 °C at 1,210 °C, interchangeable metal inserts and 0.01 °C resolution. An optional Process Calibrator with up to four measurement channels, HART communication and self calibration functions expands the system for demanding professional calibration applications.

Additel ADT 875-1210 is a high precision reference calibration furnace designed for demanding thermocouple calibration at high temperatures. As the reference version of Additel’s high temperature series, the instrument was specifically developed for applications requiring excellent temperature accuracy, stability and uniformity. With a temperature range from 100 °C to 1,210 °C, the Additel ADT 875-1210 is particularly suitable for professional calibration laboratories, quality assurance, research and industrial temperature metrology.

Innovative multi-zone temperature control creates a stable and uniform temperature zone for reproducible comparison calibrations. Compared with the standard ADT 875 series, the Additel ADT 875-1210 provides higher specified display accuracy. At 1,210 °C, the specified display accuracy is ±1.5 °C, making the instrument particularly attractive for users with demanding metrological requirements.

Interchangeable metal inserts enable adaptation to different devices under test. A 6.5 inch color touchscreen provides clear and intuitive operation, while USB, LAN, WiFi and Bluetooth interfaces simplify integration into modern laboratory environments.

At europascal, you can obtain the Additel ADT 875-1210 together with expert advice on selecting the appropriate configuration, inserts and options for your individual temperature calibration requirements.

Your Benefits at a Glance

  • Reference calibration furnace for demanding temperature calibration
  • Temperature range from 100 °C to 1,210 °C
  • Reference version of the Additel high temperature series
  • Higher display accuracy compared with the ADT 875-1210
  • Display accuracy down to ±1.5 °C at 1,210 °C
  • High temperature stability
  • Patented multi-zone temperature control
  • Optimized axial and radial temperature uniformity
  • Temperature resolution of 0.01 °C
  • Fast achievement of the required calibration temperature
  • Interchangeable metal inserts
  • Optional integrated process calibrator
  • Up to four integrated measurement channels with Process Calibrator option
  • Thermocouple measurement with Process Calibrator option
  • Testing of temperature switches and transmitters
  • HART communication with corresponding option
  • Internal and external sensor control with Process Calibrator option
  • Self calibration function with Process Calibrator option
  • 6.5 inch color touchscreen
  • USB, LAN, WiFi and Bluetooth communication
  • ISO/IEC 17025 accredited calibration with measurement data included from the factory

Ideal for Demanding Calibration Applications

The Additel ADT 875-1210 is particularly suitable for users where the quality of the temperature source has a significant influence on the calibration result. During comparison calibration of thermocouples, not only the set temperature but also the stability and temperature distribution within the calibration zone are critical.

The multi-zone temperature control of the reference calibration furnace is designed to provide a highly stable and uniform temperature zone. This makes the ADT 875-1210 particularly suitable for high quality comparison calibrations.

Typical applications include:

  • DAkkS accredited calibration laboratories
  • Primary and secondary calibration laboratories
  • In house calibration laboratories
  • Quality assurance
  • Research and development
  • Thermocouple manufacturers
  • Energy supply
  • Process industries
  • Metallurgy
  • Mechanical and plant engineering
  • Aerospace
  • Industrial temperature metrology

The wide temperature range up to 1,210 °C enables calibration of different thermocouples and temperature probes. Interchangeable inserts allow the calibration furnace to be adapted to different probe diameters.

For regular calibration of your temperature measuring equipment, europascal also provides a professional Calibration Service for temperature and other measurement quantities.

Flexible Configuration

The Additel ADT 875-1210 can be adapted to different calibration applications using interchangeable inserts and optional configurations. The interchangeable metal inserts accommodate different devices under test and provide excellent flexibility in daily laboratory operation.

The optional Process Calibrator version significantly expands the capabilities of the system. It provides up to four integrated measurement channels and enables direct measurement of thermocouples and additional electrical signals. Temperature generation and electrical measurement can therefore be combined within one system.

With the appropriate option, the ADT 875-1210 also supports communication with HART transmitters. Documentation functions support recurring calibration tasks and standardized calibration workflows.

Internal and external sensor control functions are also available. The Process Calibrator configuration additionally provides a self calibration function. This allows the ADT 875-1210 to be expanded from a powerful reference temperature source into a comprehensive platform for professional temperature calibration.

Technical Highlights

  • Temperature range: 100 °C to 1,210 °C
  • Reference model of the ADT 87X high temperature series
  • Display accuracy: ±1.0 °C at 100 °C
  • Display accuracy: ±1.0 °C at 300 °C
  • Display accuracy: ±1.0 °C at 600 °C
  • Display accuracy: ±1.2 °C at 900 °C
  • Display accuracy: ±1.5 °C at 1,210 °C
  • Temperature resolution: 0.01 °C
  • Multi-zone temperature control
  • Interchangeable metal inserts
  • 6.5 inch TFT color touchscreen
  • Temperature units: °C, °F and K
  • Optional Process Calibrator
  • Up to four measurement channels with Process Calibrator option
  • Optional HART communication
  • USB
  • LAN
  • WiFi
  • Bluetooth
  • Power consumption: 580 W
  • Compact design for laboratory and mobile applications

Technical Specifications

FeatureSpecification
ManufacturerAdditel
ModelADT 875-1210
Device typeReference Calibration Furnace
Temperature range100 °C to 1,210 °C
Display accuracy at 100 °C±1.0 °C
Display accuracy at 300 °C±1.0 °C
Display accuracy at 600 °C±1.0 °C
Display accuracy at 900 °C±1.2 °C
Display accuracy at 1,210 °C±1.5 °C
Temperature resolution0.01 °C
Temperature controlMulti-zone control
Display6.5 inch TFT color touchscreen
Display resolution640 × 480 pixels
Temperature units°C, °F and K
InsertsInterchangeable metal inserts
InterfacesUSB, LAN, WiFi, Bluetooth
Power supply90 to 242 VAC, 45 to 65 Hz
Power consumption580 W
DimensionsApprox. 170 × 345 × 330 mm
Process CalibratorOptional
Measurement channelsUp to 4 with Process Calibrator option
HART communicationOptional

Why Choose the Additel ADT 875-1210?

The Additel ADT 875-1210 Reference Calibration Furnace was designed for users with particularly demanding requirements for their high temperature reference source. Within the high temperature product range, Additel positions the ADT 878 as the reference model, while the ADT 875 provides the standard solution.

A key advantage is the higher specified display accuracy. Depending on the temperature point, the ADT 875-1210 provides specified display accuracy from ±1.0 °C to ±1.5 °C. The standard ADT 875-1210, by comparison, provides specified display accuracy from approximately ±1.2 °C to ±2.0 °C, depending on temperature.

Temperature distribution is equally important for professional calibration applications. The patented multi-zone temperature control supports a stable and uniform heat source, creating suitable conditions for reproducible comparison calibrations.

The 0.01 °C temperature resolution enables precise temperature setting and monitoring. The large color touchscreen also simplifies operation during daily laboratory work.

USB, LAN, WiFi and Bluetooth connectivity allow the reference calibration furnace to be integrated into modern laboratory environments. With the optional Process Calibrator functionality, thermocouples and transmitters can also be measured directly and additional calibration tasks can be documented.

The Additel ADT 875-1210 therefore combines a powerful high temperature source, high metrological performance and flexible expansion capabilities.

Additel ADT 875-1210 or ADT 875-1210?

Additel provides two performance levels for high temperature calibration applications.

The Additel ADT 875-1210 is designed as a standard calibration furnace and is suitable for numerous professional and industrial calibration applications. The Additel ADT 875-1210, in contrast, is the reference version for applications with higher metrological requirements.

Both models cover a temperature range from 100 °C to 1,210 °C and use a flexible concept based on multi-zone temperature control and interchangeable metal inserts.

One of the main differences is the higher specified display accuracy of the ADT 875-1210. At 1,210 °C, Additel specifies a display accuracy of ±1.5 °C for the reference model. For the standard ADT 875-1210, the specified display accuracy at the same temperature is ±2.0 °C.

For professional industrial calibration tasks requiring a powerful high temperature source, the Additel ADT 875-1210 provides an alternative within the standard product line. The Additel ADT 875-1210 is designed for reference applications and calibration laboratories with more demanding metrological requirements.

europascal can assist you in selecting the appropriate version based on your required measurement uncertainty, thermocouple types and planned calibration tasks.

Additional Models in the Additel ADT 878 Series

In addition to the Additel ADT 878-1210, the ADT 878 product family includes several reference dry well calibrators for lower temperature ranges.

For applications below ambient temperature, the Additel ADT 878-160 covers a temperature range from −40 °C to 160 °C. It also supports the optional ADT 878-TPW-KIT for automated realization and maintenance of the triple point of water.

For medium temperature applications, the Additel ADT 878-425 covers temperatures from 33 °C to 425 °C and provides excellent stability and temperature uniformity for demanding comparison calibrations.

For higher temperature PRT calibration, the Additel ADT 878-700 extends the operating range up to 700 °C and additionally provides an integrated automatic annealing function for high quality PRT sensors.

The Additel ADT 875-1210 completes the series for high temperature thermocouple calibration up to 1,210 °C.

Users can therefore select between the ADT 878-160, ADT 878-425, ADT 878-700 and ADT 875-1210 according to the required temperature range, sensor type and metrological requirements.

europascal can assist you in selecting the appropriate reference calibrator based on your required temperature range, sensor types and target measurement uncertainty.

Typical Calibration Applications with the Additel ADT 875-1210

The Additel ADT 875-1210 is particularly suitable for high quality comparison calibration of thermocouples and other temperature probes. Its temperature range from 100 °C to 1,210 °C covers numerous high temperature applications in calibration laboratories, industry and research.

In a typical comparison calibration, the reference probe and device under test are positioned in an appropriate insert. Multi-zone temperature control provides a highly uniform temperature zone. Once stability has been reached, the measurement values from the reference and device under test can be compared and documented.

The optional Process Calibrator version further expands the application range. Thermocouples can be measured directly, while temperature switches and transmitters can be integrated into corresponding test procedures. Optional HART communication additionally supports compatible intelligent temperature transmitters.

For applications with less demanding reference accuracy requirements, the Additel ADT 875-1210 provides the standard version. For other temperature ranges, additional models from the ADT 875 and ADT 878 product families are available.

Additional solutions for professional temperature calibration are available from europascal in the Dry Well Calibrators category.

Discover more Additel products here.

Manufacturer information about the Additel ADT 875-1210 is available on the official Additel website.

Download Datasheet

 

Other Products

Nach oben scrollen

Request a Quote Now!

Download Product Datasheet

Enter your email address below to access the official product datasheet, including technical specifications, measurement ranges, product features, and performance details.

Produktdatenblatt herunterladen

Geben Sie unten Ihre E-Mail-Adresse ein, um auf das offizielle Produktdatenblatt zuzugreifen – einschließlich technischer Spezifikationen, Messbereiche, Produktmerkmale und Leistungsdaten.